Index: AlarmDefs.h =================================================================== diff -u -r7bdebb83418eb57b2ce574eadeecb8677b7afc0a -r144e631ca5c756cd7a935e681066aab2152de674 --- AlarmDefs.h (.../AlarmDefs.h) (revision 7bdebb83418eb57b2ce574eadeecb8677b7afc0a) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 144e631ca5c756cd7a935e681066aab2152de674) @@ -69,7 +69,9 @@ ALARM_ID_DD_CD3_SENSOR_FPGA_FAULT = 38, ///< DD CD3 conductivity sensor freshness/error timeout fault ALARM_ID_DD_CD4_SENSOR_FPGA_FAULT = 39, ///< DD CD4 conductivity sensor freshness/error timeout fault ALARM_ID_TD_VENOUS_BUBBLE_DETECTED = 40, ///< TD venous bubble detected - NUM_OF_ALARM_IDS ///< Total number of alarms + ALARM_ID_TD_CARTRIDGE_DOOR_OPENED = 41, ///< TD front door open + ALARM_ID_TD_STUCK_BUTTON_TEST_FAILED = 42, ///< TD stuck button self test failure + NUM_OF_ALARM_IDS ///< Number of alarms }; typedef enum Alarm_List ALARM_ID_T; ///< Type for alarm list enumeration @@ -243,6 +245,8 @@ { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DD_CD3_SENSOR_FPGA_FAULT }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DD_CD4_SENSOR_FPGA_FAULT }, { ALARM_PRIORITY_HIGH, 12, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , ALARM_ID_TD_VENOUS_BUBBLE_DETECTED, }, + { ALARM_PRIORITY_HIGH, 210, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_TD_CARTRIDGE_DOOR_OPENED }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_TD_STUCK_BUTTON_TEST_FAILED }, }; // Priority Rank Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr ClrOnly TxLog ID /// Table of alarms and their rank. @@ -252,6 +256,7 @@ { 1, ALARM_ID_TD_WATCHDOG_POST_TEST_FAILED }, { 1, ALARM_ID_TD_UI_COMM_POST_FAILED }, { 1, ALARM_ID_TD_ALARM_AUDIO_SELF_TEST_FAILURE }, + { 1, ALARM_ID_TD_STUCK_BUTTON_TEST_FAILED }, { 10, ALARM_ID_TD_SOFTWARE_FAULT }, { 10, ALARM_ID_TD_UI_COMM_TIMEOUT }, { 10, ALARM_ID_TD_COMM_TOO_MANY_BAD_CRCS }, @@ -287,6 +292,7 @@ { 111, ALARM_ID_TD_CAN_MESSAGE_NOT_ACKED_BY_DD }, { 111, ALARM_ID_DD_CAN_MESSAGE_NOT_ACKED_BY_RO }, { 111, ALARM_ID_DD_CAN_MESSAGE_NOT_ACKED_BY_TD }, + { 210, ALARM_ID_TD_CARTRIDGE_DOOR_OPENED }, { 852, ALARM_ID_TD_AC_POWER_LOST }, { 999, ALARM_ID_NO_ALARM }, }; @@ -345,15 +351,17 @@ { 30 , ALARM_ID_DD_SPENT_DIALYSATE_PRES_TIMEOUT_FAULT , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Spent Dial Pressure Sensor Error | DD spent dialysate pressure sensor reporting error or not being read successfully | Spent dialysate pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, { 31 , ALARM_ID_DD_FRESH_DIALYSATE_PRES_TIMEOUT_FAULT , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fresh Dial Pressure Sensor Error | DD fresh dialysate pressure sensor reporting error or not being read successfully | Fresh dialysate pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, { 32 , ALARM_ID_DD_TRANSMEMB_PRES_TIMEOUT_FAULT , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Transmemb Pressure Sensor Error | DD transmembrane sensor reporting error or not being read successfully | Transmembrane pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, - { 33 , ALARM_ID_TD_VOLTAGE_OUT_OF_RANGE , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | HD Fault: Voltage Monitor | HD monitored voltage is out of range | If the HD monitored voltages are out of range for a certain period of time. | "}, - { 34 , ALARM_ID_TD_AC_POWER_LOST , "TD | Power Loss | AC Power has been lost.\n- Check all electrical connections.\n- Press Resume/OK to return to welcome screen. | Loss of AC Power | HD AC power lost alarm | The HD Software shall trigger an alarm if an AC power loss is detected while the HD system is in standby, service, or treatment parameters mode. | "}, - { 35 , ALARM_ID_TD_AC_POWER_LOST_IN_TREATMENT , "TD | Power Loss | Treatment must be terminated due to a power loss.\n- Follow clinic instructions on when to initiate manual rinseback.\n- Check all electrical connections.\n- If power returns within 5 minutes of outage, \n- rinseback will be allowed. | Blood Stop: Loss of AC Power | HD AC power lost alarm | The HD Software shall trigger an alarm if an AC power loss is detected while the HD system is in pre-treatment, treatment, or post-treatment mode. | "}, + { 33 , ALARM_ID_TD_VOLTAGE_OUT_OF_RANGE , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Voltage Monitor | TD monitored voltage is out of range | If the TD monitored voltages are out of range for a certain period of time. | "}, + { 34 , ALARM_ID_TD_AC_POWER_LOST , "TD | Power Loss | AC Power has been lost.\n- Check all electrical connections.\n- Press Resume/OK to return to welcome screen. | Loss of AC Power | TD AC power lost alarm | The TD Software shall trigger an alarm if an AC power loss is detected while the TD system is in standby, service, or treatment parameters mode. | "}, + { 35 , ALARM_ID_TD_AC_POWER_LOST_IN_TREATMENT , "TD | Power Loss | Treatment must be terminated due to a power loss.\n- Follow clinic instructions on when to initiate manual rinseback.\n- Check all electrical connections.\n- If power returns within 5 minutes of outage, \n- rinseback will be allowed. | Blood Stop: Loss of AC Power | TD AC power lost alarm | The TD Software shall trigger an alarm if an AC power loss is detected while the TD system is in pre-treatment, treatment, or post-treatment mode. | "}, { 36 , ALARM_ID_DD_CD1_SENSOR_FPGA_FAULT , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Conductivity Sensor (CD1) Error | DD conductivity sensor located before balancing chamber reporting error or not being read successfully | Conductvity Sensor (CD1) is reporting an error or FPGA is failing to read sensor. | "}, { 37 , ALARM_ID_DD_CD2_SENSOR_FPGA_FAULT , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Conductivity Sensor (CD2) Error | DD conductivity sensor located after balancing chamber reporting error or not being read successfully | Conductvity Sensor (CD2) is reporting an error or FPGA is failing to read sensor. | "}, { 38 , ALARM_ID_DD_CD3_SENSOR_FPGA_FAULT , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Conductivity Sensor (CD3) Error | DD conductivity sensor located after balancing chamber reporting error or not being read successfully | Conductvity Sensor (CD3) is reporting an error or FPGA is failing to read sensor. | "}, { 39 , ALARM_ID_DD_CD4_SENSOR_FPGA_FAULT , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Conductivity Sensor (CD4) Error | DD conductivity sensor located in spent dialysate path reporting error or not being read successfully | Conductvity Sensor (CD4) is reporting an error or FPGA is failing to read sensor. | "}, - { 40 , ALARM_ID_TD_VENOUS_BUBBLE_DETECTED , "TD | Venous Air Detected | Air detected in the venous air trap.\n- Confirm arterial access placement and confirm\nconnections are secure.\n- Treatment must be terminated without rinseback. | Blood Stop: Venous Air Bubble | HD venous air bubble detected alarm | If bubbles are detected during the treatment. | "}, -}; + { 40 , ALARM_ID_TD_VENOUS_BUBBLE_DETECTED , "TD | Venous Air Detected | Air detected in the venous air trap.\n- Confirm arterial access placement and confirm\nconnections are secure.\n- Treatment must be terminated without rinseback. | Blood Stop: Venous Air Bubble | TD venous air bubble detected alarm | If bubbles are detected during the treatment. | "}, + { 41 , ALARM_ID_TD_CARTRIDGE_DOOR_OPENED , "TD | Blood Pump Stopped: Door Open | The device door is open.\n Close the device door. \n- Press Resume/OK to continue. | Blood Stop: Door Open | TD cartridge door opened alarm | If the cartridge door is opened as reported by the FPGA. | "}, + { 42 , ALARM_ID_TD_STUCK_BUTTON_TEST_FAILED , "TD | Stuck Button | A button was pressed during start up and appears stuck. \n- Press and release the power and stop buttons on the\nfront of the device.\n- Turn device off, then back on.\n- If problem continues, call service to schedule a repair. | TD POST: Stuck Button | TD Stuck button POST failure. Stop or Off button detected to be pressed for at least 1 second during test shortly after power up | Stop or Off button are pressed for more than 1 sec during POST. | "}, + }; #endif // manual alarms