Index: AlarmDefs.h =================================================================== diff -u -r81ff5f19e5b89274008b5b239f2a8f660890703e -rc298a34e4ee7b9e1ef4d5b17eb3b80df3e2db371 --- AlarmDefs.h (.../AlarmDefs.h) (revision 81ff5f19e5b89274008b5b239f2a8f660890703e) +++ AlarmDefs.h (.../AlarmDefs.h) (revision c298a34e4ee7b9e1ef4d5b17eb3b80df3e2db371) @@ -179,7 +179,7 @@ ALARM_ID_FP_RO_INLET_CONDUCTIVITY_HIGH_RANGE = 147, ///< FP pump inlet conductivity high ALARM_ID_FP_REJECTION_RATIO_LOW_RANGE = 148, ///< FP rejection ratio low ALARM_ID_FP_INLET_PRESSURE_REGULATOR_OUT_OF_RANGE = 149, ///< FP inlet pressure regulator out of range - ALARM_ID_AVAILABLE_150 = 150, ///< FP Available alarm + ALARM_ID_FP_PERMEATE_FLOW_RATE_BELOW_TARGET = 150, ///< FP flow rate below 75% of target flow ALARM_ID_FP_PERMEATE_FLUSH_CONDUCTIVITY_TIMEOUT = 151, ///< FP membrane flush timeout ALARM_ID_FP_CONCENTRATE_FLUSH_TANK_FULL_TIMEOUT = 152, ///< FP concentrate flush tank full timeout ALARM_ID_FP_GEN_PERMEATE_TANK_FULL_TIMEOUT = 153, ///< FP tank full time out alarm @@ -475,6 +475,7 @@ { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_FP_PRESSURE_RELIEF_OUT_HIGH_RANGE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_FP_POWER_BUDGET_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_FP_FLOW_RATE_LOW_RANGE }, + { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_FP_PERMEATE_FLOW_RATE_BELOW_TARGET }, { ALARM_PRIORITY_MEDIUM, 432, ALM_SRC_FP, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, TRUE , ALARM_ID_FP_INLET_TEMPERATURE_OUT_LOW_RANGE }, { ALARM_PRIORITY_MEDIUM, 433, ALM_SRC_FP, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, TRUE , ALARM_ID_FP_INLET_TEMPERATURE_OUT_HIGH_RANGE }, { ALARM_PRIORITY_MEDIUM, 434, ALM_SRC_FP, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, TRUE , ALARM_ID_FP_INLET_PRESSURE_OUT_LOW_RANGE }, @@ -486,7 +487,6 @@ { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_FP_RO_INLET_CONDUCTIVITY_HIGH_RANGE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_FP_REJECTION_RATIO_LOW_RANGE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_FP_INLET_PRESSURE_REGULATOR_OUT_OF_RANGE }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_AVAILABLE_150 }, // Priority Rank Source Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr AutoRes ClrOnly TxLog ID { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_PERMEATE_FLUSH_CONDUCTIVITY_TIMEOUT }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_CONCENTRATE_FLUSH_TANK_FULL_TIMEOUT }, @@ -599,6 +599,7 @@ { 110, ALARM_ID_DD_D74_COND_SENSOR_FPGA_FAULT }, { 110, ALARM_ID_FP_RO_INLET_PRESSURE_OUT_HIGH_RANGE }, { 110, ALARM_ID_FP_FLOW_RATE_LOW_RANGE }, + { 110, ALARM_ID_FP_PERMEATE_FLOW_RATE_BELOW_TARGET }, { 110, ALARM_ID_FP_RO_OUTLET_CONDUCTIVITY_HIGH_RANGE }, { 110, ALARM_ID_FP_RO_INLET_CONDUCTIVITY_HIGH_RANGE }, { 110, ALARM_ID_FP_REJECTION_RATIO_LOW_RANGE }, @@ -653,7 +654,6 @@ { 999, ALARM_ID_AVAILABLE_32 }, { 999, ALARM_ID_AVAILABLE_58 }, { 999, ALARM_ID_AVAILABLE_93 }, - { 999, ALARM_ID_AVAILABLE_150 }, { 999, ALARM_ID_UI_RESERVED_116 }, { 999, ALARM_ID_UI_RESERVED_117 }, { 999, ALARM_ID_UI_RESERVED_118 }, @@ -848,7 +848,7 @@ { 148 , ALARM_ID_FP_INLET_PRESSURE_REGULATOR_OUT_OF_RANGE , "FP | Service Required: FP Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Fault: Pressure regulator not in range| FP pressure regulator is out of bounds | If M3 is not within 30 +/- 2 PSI | "}, { 149 , ALARM_ID_FP_POWER_BUDGET_OUT_OF_RANGE , "FP | Service Required: FP Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Fault: Power usage has exceeded budget| FP device is using too much power | If the device current is greater that its allowed percentage | "}, // Num Alarm ID Device Display Title Instructions Alarm List Title Description Trigger Condition - { 150 , ALARM_ID_AVAILABLE_150 , " | | | | | | "}, + { 150 , ALARM_ID_FP_PERMEATE_FLOW_RATE_BELOW_TARGET , "FP | Service Required: FP Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Fault: RO Pump Flow Low | FP RO pump flow out of range | If the RO flow rate < 75% from the target flow rate. | "}, { 151 , ALARM_ID_FP_PERMEATE_FLUSH_CONDUCTIVITY_TIMEOUT , "FP | FP: Filter Health | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Filters: Permeate conductivity high | FP conductivity after flushing the system is too high | If P18 conductivity > 200 uS/cm after 120 seconds ± 150ms of flushing. | "}, { 152 , ALARM_ID_FP_CONCENTRATE_FLUSH_TANK_FULL_TIMEOUT , "FP | FP: Filter Health | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Filters: Permeate Tank Fill Timeout | FP took more than 60 seconds to fill the permeate tank | If the permeate tank is not full after 60 seconds into wait for tank full state during concentrate flush. | "}, { 153 , ALARM_ID_FP_GEN_PERMEATE_TANK_FULL_TIMEOUT , "FP | FP: Permeate Overfill | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Tank: Tank is too full | FP tank level is too high | If the float sensor reads high for at least 60 seconds | "},