Index: AlarmDefs.h =================================================================== diff -u -r87823db6cffe4da9517c6dd76373cfa1b9265a5b -rd3024d32585538d5aafe43f01bc3faeb06951c9c --- AlarmDefs.h (.../AlarmDefs.h) (revision 87823db6cffe4da9517c6dd76373cfa1b9265a5b) +++ AlarmDefs.h (.../AlarmDefs.h) (revision d3024d32585538d5aafe43f01bc3faeb06951c9c) @@ -182,6 +182,8 @@ ALARM_ID_FP_FILTER_HEALTH_PRESSURE_OUT_OF_RANGE = 150, ///< RO filter health pressure out of range ALARM_ID_FP_MEMBRANE_FLUSH_CONDUCTIVITY_TIMEOUT = 151, ///< RO membrane flush timeout ALARM_ID_FP_MEMBRANE_FLUSH_VOLUME_OUT_OF_RANGE = 152, ///< RO membrane flush integrated out of range + ALARM_ID_FP_GEN_PERMEATE_TANK_FULL_TIMEOUT = 153, ///< RO tank full time out alarm + ALARM_ID_DD_DIALYSATE_TEMPERATURE_SENSORS_OUT_OF_RANGE = 154, ///< DD dialysate temperature sensors out of range NUM_OF_ALARM_IDS ///< Number of alarms }; typedef enum Alarm_List ALARM_ID_T; ///< Type for alarm list enumeration @@ -474,8 +476,11 @@ { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_REJECTION_RATIO_LOW_RANGE }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_FP_INLET_PRESSURE_REGULATOR_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_FP_FILTER_HEALTH_PRESSURE_OUT_OF_RANGE }, + // Priority Rank Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr ClrOnly TxLog ID { ALARM_PRIORITY_HIGH, 110, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_FP_MEMBRANE_FLUSH_CONDUCTIVITY_TIMEOUT }, { ALARM_PRIORITY_HIGH, 110, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_FP_MEMBRANE_FLUSH_VOLUME_OUT_OF_RANGE }, + { ALARM_PRIORITY_HIGH, 110, TRUE, FALSE, TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_FP_GEN_PERMEATE_TANK_FULL_TIMEOUT }, + { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DD_DIALYSATE_TEMPERATURE_SENSORS_OUT_OF_RANGE }, }; // Priority Rank Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr ClrOnly TxLog ID /// Table of alarms and their rank. @@ -585,6 +590,8 @@ { 110, ALARM_ID_FP_FILTER_HEALTH_PRESSURE_OUT_OF_RANGE }, { 110, ALARM_ID_FP_MEMBRANE_FLUSH_CONDUCTIVITY_TIMEOUT }, { 110, ALARM_ID_FP_MEMBRANE_FLUSH_VOLUME_OUT_OF_RANGE }, + { 110, ALARM_ID_FP_GEN_PERMEATE_TANK_FULL_TIMEOUT }, + { 110, ALARM_ID_DD_DIALYSATE_TEMPERATURE_SENSORS_OUT_OF_RANGE }, { 111, ALARM_ID_TD_DD_COMM_TIMEOUT }, { 111, ALARM_ID_TD_CAN_MESSAGE_NOT_ACKED_BY_DD }, { 111, ALARM_ID_DD_CAN_MESSAGE_NOT_ACKED_BY_RO }, @@ -815,6 +822,8 @@ { 150 , ALARM_ID_FP_FILTER_HEALTH_PRESSURE_OUT_OF_RANGE , "FP | FP: Filter Health | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Filters: Pressure difference too high | FP pressure difference between the filters is too high | If the difference between M3 and P8 is ≥ 10 PSI after 2 minutes | "}, { 151 , ALARM_ID_FP_MEMBRANE_FLUSH_CONDUCTIVITY_TIMEOUT , "FP | FP: Filter Health | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Filters: Permeate conductivity high | FP conductivity after flushing the system is too high | If P18 conductivity > 200 uS/cm after 120 seconds ± 150ms of flushing. | "}, { 152 , ALARM_ID_FP_MEMBRANE_FLUSH_VOLUME_OUT_OF_RANGE , "FP | FP: Filter Health | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Filters: Volume difference too high | FP volume difference between integrated flow and expected volume | If P7 is <90% of the target integrated volume ( 1L ) after 30 seconds ± 150ms of flushing. | "}, + { 153 , ALARM_ID_FP_GEN_PERMEATE_TANK_FULL_TIMEOUT , "FP | FP: Permeate Overfill | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Tank: Tank is too full | FP tank level is too high | If the float sensor reads high for at least 60 seconds | "}, + { 154 , ALARM_ID_DD_DIALYSATE_TEMPERATURE_SENSORS_OUT_OF_RANGE , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: D28 and D30 Delta | DD dialysate temperature sensors drift timeout. | If D28 and D30 have drifted for more 1 C for a certain period of time. | "}, }; #endif // manual alarms