Index: AlarmDefs.h =================================================================== diff -u -r8cf94d51bbaedea33f8758fade8330cddbb5d34f -rfc4516f33d73a004be26e41f9eeab53fa3a7000d --- AlarmDefs.h (.../AlarmDefs.h) (revision 8cf94d51bbaedea33f8758fade8330cddbb5d34f) +++ AlarmDefs.h (.../AlarmDefs.h) (revision fc4516f33d73a004be26e41f9eeab53fa3a7000d) @@ -7,8 +7,8 @@ * * @file AlarmDefs.h * -* @author (last) “rkallala” -* @date (last) 15-Jan-2026 +* @author (last) Varshini Nagabooshanam +* @date (last) 26-Jan-2026 * * @author (original) Sean Nash * @date (original) 01-Aug-2024 @@ -56,8 +56,8 @@ ALARM_ID_DD_VALVE_CONTROL_FAILURE = 25, ///< DD FPGA not accepting commanded valve states ALARM_ID_TD_ARTERIAL_SENSOR_TIMEOUT_FAULT = 26, ///< TD arterial pressure sensor freshness/error timeout fault ALARM_ID_TD_VENOUS_SENSOR_TIMEOUT_FAULT = 27, ///< TD venous pressure sensor freshness/error timeout fault - ALARM_ID_AVAILABLE_28 = 28, ///< Available alarms - ALARM_ID_AVAILABLE_29 = 29, ///< Available alarms + ALARM_ID_TD_TMP_PRESSURE_LOW = 28, ///< TD TMP pressure low + ALARM_ID_TD_TMP_PRESSURE_HIGH = 29, ///< TD TMP pressure high ALARM_ID_AVAILABLE_30 = 30, ///< Available alarms ALARM_ID_AVAILABLE_31 = 31, ///< Available alarms ALARM_ID_AVAILABLE_32 = 32, ///< Available alarms @@ -361,8 +361,8 @@ // Priority Rank Source Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr AutoRes ClrOnly TxLog ID { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_ARTERIAL_SENSOR_TIMEOUT_FAULT }, { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_VENOUS_SENSOR_TIMEOUT_FAULT }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_AVAILABLE_28 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_AVAILABLE_29 }, + { ALARM_PRIORITY_HIGH, 204, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, TRUE, ALARM_ID_TD_TMP_PRESSURE_LOW }, + { ALARM_PRIORITY_HIGH, 205, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, TRUE, ALARM_ID_TD_TMP_PRESSURE_HIGH }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_AVAILABLE_30 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_AVAILABLE_31 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_AVAILABLE_32 }, @@ -632,6 +632,8 @@ { 201, ALARM_ID_TD_VENOUS_PRESSURE_HIGH }, { 202, ALARM_ID_TD_ARTERIAL_PRESSURE_LOW }, { 203, ALARM_ID_TD_ARTERIAL_PRESSURE_HIGH }, + { 204, ALARM_ID_TD_TMP_PRESSURE_LOW }, + { 205, ALARM_ID_TD_TMP_PRESSURE_HIGH }, { 210, ALARM_ID_TD_CARTRIDGE_DOOR_OPENED }, { 290, ALARM_ID_TD_BLOOD_SITTING_WARNING }, { 300, ALARM_ID_TD_TREATMENT_STOPPED_BY_USER }, @@ -650,8 +652,6 @@ { 710, ALARM_ID_TD_PRE_TREATMENT_DRY_PRESSURE_TEST_FAILURE }, { 850, ALARM_ID_BATTERY_LOW }, { 852, ALARM_ID_TD_AC_POWER_LOST }, - { 999, ALARM_ID_AVAILABLE_28 }, - { 999, ALARM_ID_AVAILABLE_29 }, { 999, ALARM_ID_AVAILABLE_30 }, { 999, ALARM_ID_AVAILABLE_31 }, { 999, ALARM_ID_AVAILABLE_32 }, @@ -724,8 +724,8 @@ // Num Alarm ID Device Display Title Instructions Alarm List Title Description Trigger Condition { 26 , ALARM_ID_TD_ARTERIAL_SENSOR_TIMEOUT_FAULT , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Arterial Pressure Sensor Error | TD arterial pressure sensor reporting error or not being read successfully | Arterial pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, { 27 , ALARM_ID_TD_VENOUS_SENSOR_TIMEOUT_FAULT , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Venous Pressure Sensor Error | TD venous pressure sensor reporting error or not being read successfully | Venous pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, - { 28 , ALARM_ID_AVAILABLE_28 , " | | | | | | "}, - { 29 , ALARM_ID_AVAILABLE_29 , " | | | | | | "}, + { 28 , ALARM_ID_TD_TMP_PRESSURE_LOW , "TD | Low TMP Pressure | TMP pressure is low | | | | "}, + { 29 , ALARM_ID_TD_TMP_PRESSURE_HIGH , "TD | High TMP Pressure | TMP pressure is high | | | | "}, { 30 , ALARM_ID_AVAILABLE_30 , " | | | | | | "}, { 31 , ALARM_ID_AVAILABLE_31 , " | | | | | | "}, { 32 , ALARM_ID_AVAILABLE_32 , " | | | | | | "},