Index: AlarmDefs.h =================================================================== diff -u -r96e33a1982f4c1b7b2100a56775de3ece23e03dd -r634cc5f1560314ad2caf8fc63d4be3c518d89469 --- AlarmDefs.h (.../AlarmDefs.h) (revision 96e33a1982f4c1b7b2100a56775de3ece23e03dd) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 634cc5f1560314ad2caf8fc63d4be3c518d89469) @@ -7,8 +7,8 @@ * * @file AlarmDefs.h * -* @author (last) “rkallala” -* @date (last) 15-Jan-2026 +* @author (last) Varshini Nagabooshanam +* @date (last) 17-Mar-2026 * * @author (original) Sean Nash * @date (original) 01-Aug-2024 @@ -56,11 +56,11 @@ ALARM_ID_DD_VALVE_CONTROL_FAILURE = 25, ///< DD FPGA not accepting commanded valve states ALARM_ID_TD_ARTERIAL_SENSOR_TIMEOUT_FAULT = 26, ///< TD arterial pressure sensor freshness/error timeout fault ALARM_ID_TD_VENOUS_SENSOR_TIMEOUT_FAULT = 27, ///< TD venous pressure sensor freshness/error timeout fault - ALARM_ID_TD_CPU_RAM_ERROR = 28, ///< TD CPU RAM error - ALARM_ID_DD_CPU_RAM_ERROR = 29, ///< DD CPU RAM error - ALARM_ID_TD_INTEGRITY_POST_TEST_FAILED = 30, ///< Available alarms - ALARM_ID_DD_INTEGRITY_POST_TEST_FAILED = 31, ///< Available alarms - ALARM_ID_AVAILABLE_32 = 32, ///< Available alarms + ALARM_ID_TD_TMP_PRESSURE_LOW = 28, ///< TD TMP pressure low + ALARM_ID_TD_TMP_PRESSURE_HIGH = 29, ///< TD TMP pressure high + ALARM_ID_TD_VENOUS_BUBBLE_SELF_TEST_FAILURE = 30, ///< TD venous bubble self-test failure. + ALARM_ID_TD_BLOOD_PRIME_PAUSE_WARNING = 31, ///< TD blood prime pause warning + ALARM_ID_TD_BLOOD_PRIME_PAUSE_TIMEOUT = 32, ///< TD blood prime pause timeout ALARM_ID_TD_VOLTAGE_OUT_OF_RANGE = 33, ///< TD voltage out of range fault ALARM_ID_TD_AC_POWER_LOST = 34, ///< TD AC power lost ALARM_ID_TD_AC_POWER_LOST_IN_TREATMENT = 35, ///< TD AC power lost during treatment @@ -86,7 +86,7 @@ ALARM_ID_DD_CONCENTRATE_PUMP_FAULT = 55, ///< DD concentrate pump fault ALARM_ID_DD_TEMPERATURE_SENSOR_OUT_OF_RANGE = 56, ///< DD temperature sensor out of range ALARM_ID_DD_RTD_SENSORS_FPGA_FAULT = 57, ///< DD temperature sensors freshness timeout fault - ALARM_ID_AVAILABLE_58 = 58, ///< DD Available alarms + ALARM_ID_DD_BC_FILL_TIMEOUT_FAULT = 58, ///< DD balancing chamber fill timeout fault ALARM_ID_DD_BAROMETRIC_SENSOR_COEFFS_BAD_CRC = 59, ///< DD barometric sensor coefficients bad CRC ALARM_ID_DD_D12_PUMP_RPM_OUT_OF_RANGE = 60, ///< DD fresh dialysate pump RPM out of range ALARM_ID_DD_D12_PUMP_OFF_FAULT = 61, ///< DD fresh dialysate pump running when it is not commanded to run @@ -106,7 +106,7 @@ ALARM_ID_DD_SC_STATE1_FILL_START_PRESSURE_OUT_OF_RANGE = 75, ///< DD spent chamber state 1 fill pressure out of range ALARM_ID_DD_SC_STATE2_FILL_START_PRESSURE_OUT_OF_RANGE = 76, ///< DD spent chamber state 2 fill pressure out of range ALARM_ID_DD_SC_FILL_TIMEOUT_FAULT = 77, ///< DD spent chamber fill timeout fault - ALARM_ID_TD_AIR_TRAP_FILL_DURING_TREATMENT = 78, ///< TD air trap fill timeout alarm during treatment + ALARM_ID_TD_AIR_TRAP_FILL_TIMEOUT = 78, ///< TD air trap fill timeout ALARM_ID_TD_AIR_TRAP_ILLEGAL_LEVELS = 79, ///< TD air trap illegal levels ALARM_ID_TD_PINCH_VALVE_FAULT = 80, ///< TD pinch valve fault ALARM_ID_TD_VALVE_HOMING_FAILED = 81, ///< TD pinch valve homing fault @@ -121,7 +121,7 @@ ALARM_ID_DD_BC_STATE2_FILL_END_PRESSURE_OUT_OF_RANGE = 90, ///< DD balance chamber state2 fill end pressure not in range ALARM_ID_DD_GEND_HYD_CHAMBER_PRESS_OUT_OF_RANGE = 91, ///< DD generate dialysate hydraulics chamber ngative pressure out of range ALARM_ID_DD_BICARB_FILL_TIMEOUT_FAULT = 92, ///< DD spent chamber fill timeout fault - ALARM_ID_AVAILABLE_93 = 93, ///< Available alarms + ALARM_ID_DD_D79_RINSE_PUMP_SPEED_OUT_OF_RANGE = 93, ///< DD D79 rinse pump commanded vs measured speed out of tolerance ALARM_ID_DD_BC_STATE1_FILL_PRESSURE_DROP_OUT_OF_RANGE = 94, ///< DD balance chamber state1 fill initiated and pressure drop is not in range ALARM_ID_DD_BC_STATE2_FILL_PRESSURE_DROP_OUT_OF_RANGE = 95, ///< DD balance chamber state2 fill initiated and pressure drop is not in range ALARM_ID_TD_TREATMENT_STOPPED_BY_USER = 96, ///< TD treatment paused by user @@ -194,6 +194,11 @@ ALARM_ID_FP_PERMEATE_FLOW_OUT_HIGH_RANGE = 162, ///< FP permeate flow high fault ALARM_ID_FP_PERMEATE_FLOW_OUT_LOW_RANGE = 163, ///< FP permeate flow low fault ALARM_ID_FP_INLET_PRESSURE_LOW_RANGE = 164, ///< FP inlet pressure low fault + ALARM_ID_TD_AIR_TRAP_LOWER_TIMEOUT = 165, ///< TD air trap lower timeout + ALARM_ID_TD_CPU_RAM_ERROR = 166, ///< TD CPU RAM error + ALARM_ID_DD_CPU_RAM_ERROR = 167, ///< DD CPU RAM error + ALARM_ID_TD_INTEGRITY_POST_TEST_FAILED = 168, ///< Available alarms + ALARM_ID_DD_INTEGRITY_POST_TEST_FAILED = 169, ///< Available alarms NUM_OF_ALARM_IDS ///< Number of alarms }; typedef enum Alarm_List ALARM_ID_T; ///< Type for alarm list enumeration @@ -361,11 +366,11 @@ // Priority Rank Source Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr AutoRes ClrOnly TxLog ID { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_ARTERIAL_SENSOR_TIMEOUT_FAULT }, { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_VENOUS_SENSOR_TIMEOUT_FAULT }, - { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_CPU_RAM_ERROR }, - { ALARM_PRIORITY_HIGH, 10, ALM_SRC_DD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_CPU_RAM_ERROR }, - { ALARM_PRIORITY_HIGH, 1, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_INTEGRITY_POST_TEST_FAILED }, - { ALARM_PRIORITY_HIGH, 1, ALM_SRC_DD, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_INTEGRITY_POST_TEST_FAILED }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_AVAILABLE_32 }, + { ALARM_PRIORITY_HIGH, 204, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , ALARM_ID_TD_TMP_PRESSURE_LOW }, + { ALARM_PRIORITY_HIGH, 205, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , ALARM_ID_TD_TMP_PRESSURE_HIGH }, + { ALARM_PRIORITY_LOW, 711, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_VENOUS_BUBBLE_SELF_TEST_FAILURE }, + { ALARM_PRIORITY_HIGH, 292, ALM_SRC_TD, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_BLOOD_PRIME_PAUSE_WARNING }, + { ALARM_PRIORITY_HIGH, 291, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_BLOOD_PRIME_PAUSE_TIMEOUT }, { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_VENOUS_SENSOR_TIMEOUT_FAULT }, { ALARM_PRIORITY_LOW , 852, ALM_SRC_TD, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_AC_POWER_LOST }, { ALARM_PRIORITY_HIGH, 100, ALM_SRC_TD, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , ALARM_ID_TD_AC_POWER_LOST_IN_TREATMENT }, @@ -392,7 +397,7 @@ { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_CONCENTRATE_PUMP_FAULT }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_TEMPERATURE_SENSOR_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_RTD_SENSORS_FPGA_FAULT }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_AVAILABLE_58 }, + { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_BC_FILL_TIMEOUT_FAULT }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE, TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_BAROMETRIC_SENSOR_COEFFS_BAD_CRC }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_D12_PUMP_RPM_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_D12_PUMP_OFF_FAULT }, @@ -413,7 +418,7 @@ // Priority Rank Source Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr AutoRes ClrOnly TxLog ID { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_SC_STATE2_FILL_START_PRESSURE_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_SC_FILL_TIMEOUT_FAULT }, - { ALARM_PRIORITY_HIGH, 13, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , ALARM_ID_TD_AIR_TRAP_FILL_DURING_TREATMENT }, + { ALARM_PRIORITY_HIGH, 13, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , ALARM_ID_TD_AIR_TRAP_FILL_TIMEOUT }, { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_AIR_TRAP_ILLEGAL_LEVELS }, { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_PINCH_VALVE_FAULT }, { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_VALVE_HOMING_FAILED }, @@ -428,7 +433,7 @@ { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_BC_STATE2_FILL_END_PRESSURE_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_GEND_HYD_CHAMBER_PRESS_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_BICARB_FILL_TIMEOUT_FAULT }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_AVAILABLE_93 }, + { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_D79_RINSE_PUMP_SPEED_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_BC_STATE1_FILL_PRESSURE_DROP_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_BC_STATE2_FILL_PRESSURE_DROP_OUT_OF_RANGE }, { ALARM_PRIORITY_MEDIUM, 300, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_TREATMENT_STOPPED_BY_USER }, @@ -503,6 +508,11 @@ { ALARM_PRIORITY_HIGH, 10, ALM_SRC_FP, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_PERMEATE_FLOW_OUT_HIGH_RANGE }, { ALARM_PRIORITY_HIGH, 10, ALM_SRC_FP, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_PERMEATE_FLOW_OUT_LOW_RANGE }, { ALARM_PRIORITY_HIGH, 10, ALM_SRC_FP, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_INLET_PRESSURE_LOW_RANGE }, + { ALARM_PRIORITY_HIGH, 13, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , ALARM_ID_TD_AIR_TRAP_LOWER_TIMEOUT }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_CPU_RAM_ERROR }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_DD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_CPU_RAM_ERROR }, + { ALARM_PRIORITY_HIGH, 1, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_INTEGRITY_POST_TEST_FAILED }, + { ALARM_PRIORITY_HIGH, 1, ALM_SRC_DD, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_INTEGRITY_POST_TEST_FAILED }, }; // Priority Rank Source Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr AutoRes ClrOnly TxLog ID /// Table of alarms and their rank. @@ -560,7 +570,8 @@ { 10, ALARM_ID_DD_CPU_RAM_ERROR }, { 11, ALARM_ID_TD_BLOOD_SITTING_TOO_LONG }, { 12, ALARM_ID_TD_VENOUS_BUBBLE_DETECTED }, - { 13, ALARM_ID_TD_AIR_TRAP_FILL_DURING_TREATMENT }, + { 13, ALARM_ID_TD_AIR_TRAP_FILL_TIMEOUT }, + { 13, ALARM_ID_TD_AIR_TRAP_LOWER_TIMEOUT }, { 100, ALARM_ID_TD_AC_POWER_LOST_IN_TREATMENT }, { 110, ALARM_ID_DD_CRITICAL_DATA_ERROR }, { 110, ALARM_ID_DD_WATCHDOG_EXPIRED }, @@ -575,6 +586,7 @@ { 110, ALARM_ID_DD_D27_COND_SENSOR_FPGA_FAULT }, { 110, ALARM_ID_DD_D29_COND_SENSOR_FPGA_FAULT }, { 110, ALARM_ID_DD_D43_COND_SENSOR_FPGA_FAULT }, + { 110, ALARM_ID_DD_BC_FILL_TIMEOUT_FAULT }, { 110, ALARM_ID_FP_FPGA_COMM_TIMEOUT }, { 110, ALARM_ID_DD_D11_PUMP_SPEED_CONTROL_ERROR }, { 110, ALARM_ID_DD_D10_PUMP_SPEED_CONTROL_ERROR }, @@ -619,6 +631,7 @@ { 110, ALARM_ID_FP_GEN_PERMEATE_TANK_FULL_TIMEOUT }, { 110, ALARM_ID_DD_DIALYSATE_TEMPERATURE_SENSORS_OUT_OF_RANGE }, { 110, ALARM_ID_DD_D76_PUMP_SPEED_CONTROL_ERROR }, + { 110, ALARM_ID_DD_D79_RINSE_PUMP_SPEED_OUT_OF_RANGE }, { 110, ALARM_ID_DD_SC_STATE1_FILL_START_PRESSURE_OUT_OF_RANGE }, { 110, ALARM_ID_DD_SC_STATE2_FILL_START_PRESSURE_OUT_OF_RANGE }, { 110, ALARM_ID_DD_SC_FILL_TIMEOUT_FAULT }, @@ -636,8 +649,12 @@ { 201, ALARM_ID_TD_VENOUS_PRESSURE_HIGH }, { 202, ALARM_ID_TD_ARTERIAL_PRESSURE_LOW }, { 203, ALARM_ID_TD_ARTERIAL_PRESSURE_HIGH }, + { 204, ALARM_ID_TD_TMP_PRESSURE_LOW }, + { 205, ALARM_ID_TD_TMP_PRESSURE_HIGH }, { 210, ALARM_ID_TD_CARTRIDGE_DOOR_OPENED }, { 290, ALARM_ID_TD_BLOOD_SITTING_WARNING }, + { 291, ALARM_ID_TD_BLOOD_PRIME_PAUSE_TIMEOUT }, + { 292, ALARM_ID_TD_BLOOD_PRIME_PAUSE_WARNING }, { 300, ALARM_ID_TD_TREATMENT_STOPPED_BY_USER }, { 401, ALARM_ID_DD_DIALYSATE_TEMP_ABOVE_SAFETY_TEMP }, { 401, ALARM_ID_DD_DIALYSATE_TEMP_ABOVE_TARGET_TEMP }, @@ -652,11 +669,9 @@ { 700, ALARM_ID_TD_ARTERIAL_PRESSURE_SELF_TEST_FAILURE }, { 700, ALARM_ID_TD_VENOUS_PRESSURE_SELF_TEST_FAILURE }, { 710, ALARM_ID_TD_PRE_TREATMENT_DRY_PRESSURE_TEST_FAILURE }, + { 711, ALARM_ID_TD_VENOUS_BUBBLE_SELF_TEST_FAILURE }, { 850, ALARM_ID_BATTERY_LOW }, { 852, ALARM_ID_TD_AC_POWER_LOST }, - { 999, ALARM_ID_AVAILABLE_32 }, - { 999, ALARM_ID_AVAILABLE_58 }, - { 999, ALARM_ID_AVAILABLE_93 }, { 999, ALARM_ID_UI_RESERVED_116 }, { 999, ALARM_ID_UI_RESERVED_117 }, { 999, ALARM_ID_UI_RESERVED_118 }, @@ -724,11 +739,11 @@ // Num Alarm ID Device Display Title Instructions Alarm List Title Description Trigger Condition { 26 , ALARM_ID_TD_ARTERIAL_SENSOR_TIMEOUT_FAULT , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Arterial Pressure Sensor Error | TD arterial pressure sensor reporting error or not being read successfully | Arterial pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, { 27 , ALARM_ID_TD_VENOUS_SENSOR_TIMEOUT_FAULT , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Venous Pressure Sensor Error | TD venous pressure sensor reporting error or not being read successfully | Venous pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, - { 28 , ALARM_ID_TD_CPU_RAM_ERROR , "TD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD CPU RAM error | TD CPU RAM check failure | If the RAM status indicates any of the following: Double bit error, Address decode failure, Address decode logic element failure, Read address parity failure, Write address parity failure. | "}, - { 29 , ALARM_ID_DD_CPU_RAM_ERROR , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD CPU RAM error | DD CPU RAM check failure | If the RAM status indicates any of the following: Double bit error, Address decode failure, Address decode logic element failure, Read address parity failure, Write address parity failure. | "}, - { 30 , ALARM_ID_TD_INTEGRITY_POST_TEST_FAILED , "TD | Service Required: Hemodialysis Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Firmware Image Integrity Failure | TD firmware image integrity POST test failed | If the calculated CRC of the TD image does not match the expected CRC. | "}, - { 31 , ALARM_ID_DD_INTEGRITY_POST_TEST_FAILED , "DD | Service Required: Hemodialysis Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Firmware Image Integrity Failure | DD firmware image integrity POST test failed | If the calculated CRC of the DD image does not match the expected CRC. | "}, - { 32 , ALARM_ID_AVAILABLE_32 , " | | | | | | "}, + { 28 , ALARM_ID_TD_TMP_PRESSURE_LOW , "TD | Low TMP Pressure | TMP pressure is low | | | | "}, + { 29 , ALARM_ID_TD_TMP_PRESSURE_HIGH , "TD | High TMP Pressure | TMP pressure is high | | | | "}, + { 30 , ALARM_ID_TD_VENOUS_BUBBLE_SELF_TEST_FAILURE , "TD | Self Test: Venous Air Detector | A problem has been detected with the venous air detector.\n- Check cartridge installation.\n- If problem persists, terminate treatment preparation and \n begin again using a new cartridge. | Process: Pre- Tx Wet Self- Test | TD venous air bubble detector self-test failure | If the venous air bubble self test did not detect bubble for more than 500 msec | "}, + { 31 , ALARM_ID_TD_BLOOD_PRIME_PAUSE_WARNING , "TD | MAX Blood Prime Pause Time | The Blood Prime pause time has nearly reached the maximum limit.\n- You must resume Blood Prime before the pause timer expires.\n- If Blood Prime is not resumed before the timer expires,\nBlood Prime will be terminated and treatment will transition to a safe state. | Blood Prime Paused: Warning | Blood Prime pause approaching timeout (> 4 min). | During Blood Prime paused state, when the pause duration exceeds 4 minutes. | "}, + { 32 , ALARM_ID_TD_BLOOD_PRIME_PAUSE_TIMEOUT , "TD | MAX Blood Prime Pause Time Reached | The maximum Blood Prime pause time has been reached.\n- Blood Prime has been paused for more than the allowed duration.\n- Treatment must be restarted or handled according to system safety procedures. | Blood Prime Paused: Alarm | Blood Prime pause timeout reached (> 5 min). | During Blood Prime paused state, when the pause duration exceeds 5 minutes | "}, { 33 , ALARM_ID_TD_VOLTAGE_OUT_OF_RANGE , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Voltage Monitor | TD monitored voltage is out of range | If the TD monitored voltages are out of range for a certain period of time. | "}, { 34 , ALARM_ID_TD_AC_POWER_LOST , "TD | Power Loss | AC Power has been lost.\n- Check all electrical connections.\n- Press Resume/OK to return to welcome screen. | Loss of AC Power | TD AC power lost alarm | The TD Software shall trigger an alarm if an AC power loss is detected while the TD system is in standby, service, or treatment parameters mode. | "}, { 35 , ALARM_ID_TD_AC_POWER_LOST_IN_TREATMENT , "TD | Power Loss | Treatment must be terminated due to a power loss.\n- Follow clinic instructions on when to initiate manual rinseback.\n- Check all electrical connections.\n- If power returns within 5 minutes of outage, \n- rinseback will be allowed. | Blood Stop: Loss of AC Power | TD AC power lost alarm | The TD Software shall trigger an alarm if an AC power loss is detected while the TD system is in pre-treatment, treatment, or post-treatment mode. | "}, @@ -755,7 +770,7 @@ { 55 , ALARM_ID_DD_CONCENTRATE_PUMP_FAULT , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: Pump Fault | DD concentrate pump fault | If the concentrate pumps fault is reported by the FPGA. | "}, { 56 , ALARM_ID_DD_TEMPERATURE_SENSOR_OUT_OF_RANGE , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: Temp Sensor Range | DD temperature sensor out of range | If the measured temperature < 0 C or > 80 C for the non-fluid inline sensors and > 120 C for the fluid sensors. | "}, { 57 , ALARM_ID_DD_RTD_SENSORS_FPGA_FAULT , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: Temperature RTD Comm | DD temperature sensors not being read successfully | If the FPGA does not report fresh data for a certain period of time | "}, - { 58 , ALARM_ID_AVAILABLE_58 , " | | | | | | "}, + { 58 , ALARM_ID_DD_BC_FILL_TIMEOUT_FAULT , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD BC fill timeout Error | DD Balancing chamber fill timeout error | If BC fill time exceeds the allowed timeout based on the balancing chamber switching period. | "}, { 59 , ALARM_ID_DD_BAROMETRIC_SENSOR_COEFFS_BAD_CRC , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: Baro temp Cal CRC | DD barometric pressure sensor bad coefficients CRC | If the following happens: 1. The stored CRC in the sensor does not match the calculated CRC. 2. The CRC and coefficients have not been received from the sensor after 20 seconds from the power up. | "}, { 60 , ALARM_ID_DD_D12_PUMP_RPM_OUT_OF_RANGE , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: Fresh Dial Pump Speed Fault | DD fresh dialysate pump RPM out of range | If the fresh dialysate pump RPM > 300.0 of the target RPM. | "}, { 61 , ALARM_ID_DD_D12_PUMP_OFF_FAULT , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: Fresh Dial Pump Speed Not Off | DD fresh dialysate pump off fault | If the pump is in off state and the RPM is greater than the minimum RPM of 300.0 RPM. | "}, @@ -776,7 +791,7 @@ // Num Alarm ID Device Display Title Instructions Alarm List Title Description Trigger Condition { 76 , ALARM_ID_DD_SC_STATE2_FILL_START_PRESSURE_OUT_OF_RANGE , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: BC Pressure not in range | DD Spent chamber fill state 2 start pressure is not in range | If the fresh dialysate pressure (< 21 psig or > 27 psig) and spent dialysate pressure (< 24 psig or > 28 psig) not in range for spent chamber fill state2 start. | "}, { 77 , ALARM_ID_DD_SC_FILL_TIMEOUT_FAULT , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Spent Chamber fill timeout Error | DD Spent chamber fill timeout error | If the number of spent chamber fill > = 7 counts | "}, - { 78 , ALARM_ID_TD_AIR_TRAP_FILL_DURING_TREATMENT , "TD | Blood Pump Stopped: Venous Air Detector | A problem was detected with the venous air detector.\n- Confirm arterial access placement and ensure\nconnections are secure.\n- Treatment must be terminated without rinseback. | Blood Stop: Air Trap Fill | Air trap fill timeout during treatment | If the air trap fill timeout during treatment. | "}, + { 78 , ALARM_ID_TD_AIR_TRAP_FILL_TIMEOUT , "TD | Blood Pump Stopped: Venous Air Detector | A problem was detected with the venous air detector.\n- Confirm arterial access placement and ensure\nconnections are secure.\n- Treatment must be terminated without rinseback. | Blood Stop: Air Trap Fill | Air trap fill timeout during treatment | If the air trap fill timeout during treatment. | "}, { 79 , ALARM_ID_TD_AIR_TRAP_ILLEGAL_LEVELS , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Air Trap Sensor | Air trap level sensors reporting illegal combination of air/fluid | If the air trap level readings are not valid for more than 2 seconds. | "}, { 80 , ALARM_ID_TD_PINCH_VALVE_FAULT , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Pinch Valve | Pinch valve reporting a fault | If the valve detects a driver, direction or encoder fault condition. | "}, { 81 , ALARM_ID_TD_VALVE_HOMING_FAILED , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Valve Home | TD valve homing failed | If the number of failed homing > = 3 counts. | "}, @@ -791,7 +806,7 @@ { 90 , ALARM_ID_DD_BC_STATE2_FILL_END_PRESSURE_OUT_OF_RANGE , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: BC Pressure not in range | DD balancing chamber state 2 fill end pressure is not in range | If the fresh dialysate pressure (< 21 psig or > 27 psig) and spent dialysate pressure (< 27 psig or > 31 psig) not in range for balancing chamber state2 fill end. | "}, { 91 , ALARM_ID_DD_GEND_HYD_CHAMBER_PRESS_OUT_OF_RANGE , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: Hyd Cham Neg Pres not in range | DD hydraulics chamber degassing pressure is not in range | If the hydraulics chamber pressure is not less than or equal to calculated target degas pressure psig. | "} { 92 , ALARM_ID_DD_BICARB_FILL_TIMEOUT_FAULT , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Bicarb Chamber fill timeout Error | DD Bicarb chamber fill timeout error | If Bicarb chamber fill time > = 1 seconds | "}, - { 93 , ALARM_ID_AVAILABLE_93 , " | | | | | | "}, + { 93 , ALARM_ID_DD_D79_RINSE_PUMP_SPEED_OUT_OF_RANGE , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: Rinse Pump Speed Fault | DD D79 rinse pump commanded vs measured speed out of tolerance | If rinse pump measured RPM deviates beyond 10%% of target RPM when pump is commanded on. Data1=measured RPM, Data2=target RPM. | "}, { 94 , ALARM_ID_DD_BC_STATE1_FILL_PRESSURE_DROP_OUT_OF_RANGE , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: BC Pressure not in range | DD balancing chamber state 1 fill initiated and pressure drop is not in range | If the fresh dialysate pressure (< 9 psig or > 13 psig) and spent dialysate pressure (< 9 psig or > 13 psig) not in range for balancing chamber state1 fill in progress. | "}, { 95 , ALARM_ID_DD_BC_STATE2_FILL_PRESSURE_DROP_OUT_OF_RANGE , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: BC Pressure not in range | DD balancing chamber state 2 fill initiated and pressure drop is not in range | If the fresh dialysate pressure (< 9 psig or > 13 psig) and spent dialysate pressure (< 9 psig or > 13 psig) not in range for balancing chamber state2 fill in progress. | "}, { 96 , ALARM_ID_TD_TREATMENT_STOPPED_BY_USER , "TD | Blood Pump Stopped: Treatment Paused | Treatment has been stopped by user.\n- Press Resume/OK to resume treatment. \n- If treatment is not resumed within five minutes,\ntreatment will be terminated without rinseback. | Blood Stopped: Treatment Pause | TD treatment stopped by user action - pressed stop button | If the user has pressed the stop button. | "}, @@ -866,6 +881,11 @@ { 162 , ALARM_ID_FP_PERMEATE_FLOW_OUT_HIGH_RANGE , "FP | High Permeate flow | Permeate flow is too high. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Fault: Permeate flow High | Permeate flow is too high from set target flow rate | If the permeate flow is above 25% of set target flow rate for a certain period of time. | "}, { 163 , ALARM_ID_FP_PERMEATE_FLOW_OUT_LOW_RANGE , "FP | low Permeate flow | Permeate flow is too low. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Fault: Permeate flow Low | Permeate flow is too low from set target flow rate | If the permeate flow is above 25% of set target flow rate for a certain period of time. | "}, { 164 , ALARM_ID_FP_INLET_PRESSURE_LOW_RANGE , "FP | low inlet pressure | Inlet pressure is too low. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Fault: Inlet pressure Low | Inlet pressure is too low | If P8 is < 1 PSI | "}, + { 165 , ALARM_ID_TD_AIR_TRAP_LOWER_TIMEOUT , "TD | Blood Pump Stopped: Venous Air Detector | A problem was detected with the venous air detector.\n- Confirm arterial access placement and ensure\nconnections are secure.\n- Treatment must be terminated without rinseback. | Blood Stop: Air Trap Lowering | Air trap lowering timeout during treatment | If the air trap lowering timeout during treatment. | "}, + { 166 , ALARM_ID_TD_CPU_RAM_ERROR , "TD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD CPU RAM error | TD CPU RAM check failure | If the RAM status indicates any of the following: Double bit error, Address decode failure, Address decode logic element failure, Read address parity failure, Write address parity failure. | "}, + { 167 , ALARM_ID_DD_CPU_RAM_ERROR , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD CPU RAM error | DD CPU RAM check failure | If the RAM status indicates any of the following: Double bit error, Address decode failure, Address decode logic element failure, Read address parity failure, Write address parity failure. | "}, + { 168 , ALARM_ID_TD_INTEGRITY_POST_TEST_FAILED , "TD | Service Required: Hemodialysis Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Firmware Image Integrity Failure | TD firmware image integrity POST test failed | If the calculated CRC of the TD image does not match the expected CRC. | "}, + { 169 , ALARM_ID_DD_INTEGRITY_POST_TEST_FAILED , "DD | Service Required: Hemodialysis Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Firmware Image Integrity Failure | DD firmware image integrity POST test failed | If the calculated CRC of the DD image does not match the expected CRC. | "}, }; #endif // manual alarms