Index: AlarmDefs.h =================================================================== diff -u -rd1f00c0d4796ab9660986399705aea06907aa710 -r216279e6c972c98e198c0c3a0069fac0114ee89f --- AlarmDefs.h (.../AlarmDefs.h) (revision d1f00c0d4796ab9660986399705aea06907aa710) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 216279e6c972c98e198c0c3a0069fac0114ee89f) @@ -237,8 +237,8 @@ ALARM_ID_FW_RESERVED_205 = 205, ///< FW reserved for use ALARM_ID_FW_RESERVED_206 = 206, ///< FW reserved for use ALARM_ID_FW_RESERVED_207 = 207, ///< FW reserved for use - ALARM_ID_FW_RESERVED_208 = 208, ///< FW reserved for use - ALARM_ID_FW_RESERVED_209 = 209, ///< FW reserved for use + ALARM_ID_TD_INITIAL_BC_REV_PRIME_LIMIT_REACHED = 208, ///< TD initial rev blood circuit prime limit reached + ALARM_ID_TD_INITIAL_BC_REV_PRIME_TIMEOUT = 209, ///< TD initial blood circuit prime timeout ALARM_ID_FW_RESERVED_210 = 210, ///< FW reserved for use ALARM_ID_FW_RESERVED_211 = 211, ///< FW reserved for use ALARM_ID_FW_RESERVED_212 = 212, ///< FW reserved for use @@ -713,8 +713,8 @@ { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_205 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_206 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_207 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_208 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_209 }, + { ALARM_PRIORITY_HIGH, 293, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_INITIAL_BC_REV_PRIME_LIMIT_REACHED }, + { ALARM_PRIORITY_HIGH, 294, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_INITIAL_BC_REV_PRIME_TIMEOUT }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_210 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_211 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_212 }, @@ -990,6 +990,8 @@ { 290, ALARM_ID_TD_BLOOD_SITTING_WARNING }, { 291, ALARM_ID_TD_BLOOD_PRIME_PAUSE_TIMEOUT }, { 292, ALARM_ID_TD_BLOOD_PRIME_PAUSE_WARNING }, + { 293, ALARM_ID_TD_INITIAL_BC_REV_PRIME_LIMIT_REACHED }, + { 294, ALARM_ID_TD_INITIAL_BC_REV_PRIME_TIMEOUT }, { 300, ALARM_ID_TD_TREATMENT_STOPPED_BY_USER }, { 300, ALARM_ID_TD_TUBE_SET_MISMATCH }, { 401, ALARM_ID_DD_DIALYSATE_TEMP_ABOVE_SAFETY_TEMP }, @@ -1038,8 +1040,6 @@ { 999, ALARM_ID_FW_RESERVED_205 }, { 999, ALARM_ID_FW_RESERVED_206 }, { 999, ALARM_ID_FW_RESERVED_207 }, - { 999, ALARM_ID_FW_RESERVED_208 }, - { 999, ALARM_ID_FW_RESERVED_209 }, { 999, ALARM_ID_FW_RESERVED_210 }, { 999, ALARM_ID_FW_RESERVED_211 }, { 999, ALARM_ID_FW_RESERVED_212 }, @@ -1308,7 +1308,7 @@ { 162 , ALARM_ID_FP_PERMEATE_FLOW_OUT_HIGH_RANGE , "FP | High Permeate flow | Permeate flow is too high. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Fault: Permeate flow High | Permeate flow is too high from set target flow rate | If the permeate flow is above 25% of set target flow rate for a certain period of time. | "}, { 163 , ALARM_ID_FP_PERMEATE_FLOW_OUT_LOW_RANGE , "FP | low Permeate flow | Permeate flow is too low. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Fault: Permeate flow Low | Permeate flow is too low from set target flow rate | If the permeate flow is above 25% of set target flow rate for a certain period of time. | "}, { 164 , ALARM_ID_FP_INLET_PRESSURE_LOW_RANGE , "FP | low inlet pressure | Inlet pressure is too low. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Fault: Inlet pressure Low | Inlet pressure is too low | If P8 is < 1 PSI | "}, - { 165 , ALARM_ID_TD_AIR_TRAP_LOWER_TIMEOUT , "TD | Blood Pump Stopped: Venous Air Detector | A problem was detected with the venous air detector.\n- Confirm arterial access placement and ensure\nconnections are secure.\n- Treatment must be terminated without rinseback. | Blood Stop: Air Trap Lowering | Air trap lowering timeout during treatment | If the air trap lowering timeout during treatment. | "}, + { 165 , ALARM_ID_TD_AIR_TRAP_LOWER_TIMEOUT , "TD | Blood Pump Stopped: Venous Air Detector | A problem was detected with the venous air detector.\n- Confirm arterial access placement and ensure\nconnections are secure.\n- Treatment must be terminated without rinseback. | Blood Stop: Air Trap Lowering | Air trap lowering timeout during treatment | If the air trap lowering timeout during treatment. | "}, { 166 , ALARM_ID_TD_SYRINGE_PUMP_SELF_TEST_FAILURE , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe DAC | TD syringe pump self-test failure alarm | If the calibration data that was received from NVDataMgmt and the DAC voltage with syringe retracted are not within tol. | "}, { 167 , ALARM_ID_TD_SYRINGE_PUMP_RUNNING_WHILE_BP_OFF_ERROR , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe Pump On Err | TD syringe pump is running while the BP is off | If the syringe pump is on while the blood pump is off | "}, { 168 , ALARM_ID_TD_SYRINGE_PUMP_FPGA_ADC_FAULT , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe Pump ADC Com | TD syringe pump ADC error | If the ADC read is not fresh after POST init and the ADC read counter has not changed. | "}, @@ -1353,8 +1353,8 @@ { 205 , ALARM_ID_FW_RESERVED_205 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 206 , ALARM_ID_FW_RESERVED_206 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 207 , ALARM_ID_FW_RESERVED_207 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 208 , ALARM_ID_FW_RESERVED_208 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 209 , ALARM_ID_FW_RESERVED_209 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, + { 208 , ALARM_ID_TD_INITIAL_BC_REV_PRIME_LIMIT_REACHED , "TD | Prime Paused: Check Saline Line | The system has repeatedly paused priming to relieve negative pressure in the venous line.\n- Check that the saline line is not clamped or kinked.\n- Check that the saline bag is not empty.\n- Resume priming once checked, or end treatment. | Prime: BC: Venous Line, Retry Limit | Venous pressure (H14) reached the neg pressure pause limit, possibly indicating a clamped or occluded saline/H14 line. | During Blood Circuit: Venous Line prime state, when the negative pressure pause/equalize cycle has occurred 3 times. | "}, + { 209 , ALARM_ID_TD_INITIAL_BC_REV_PRIME_TIMEOUT , "TD | Prime Timeout: Venous Line | Priming the venous line and air trap did not complete within the expected time.\n- Check the saline line and connections.\n- Resume priming, or end treatment. | Prime: BC: Venous Line, Timeout | Blood Circuit: Venous Line state failed to complete within 40 seconds, excluding time spent paused for pressure equalization. | During Blood Circuit: Venous Line prime state, when the state has been active for more than 40 seconds, excluding paused time. | "}, { 210 , ALARM_ID_FW_RESERVED_210 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 211 , ALARM_ID_FW_RESERVED_211 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 212 , ALARM_ID_FW_RESERVED_212 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "},