Index: AlarmDefs.h =================================================================== diff -u -rdbf8d7f8686e298e90ee3842319977a4805a71d6 -r7f5d99c5df03b36b80087327b09bf4719ce1534c --- AlarmDefs.h (.../AlarmDefs.h) (revision dbf8d7f8686e298e90ee3842319977a4805a71d6) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 7f5d99c5df03b36b80087327b09bf4719ce1534c) @@ -181,7 +181,7 @@ ALARM_ID_FP_INLET_PRESSURE_REGULATOR_OUT_OF_RANGE = 149, ///< FP inlet pressure regulator out of range ALARM_ID_FP_FILTER_HEALTH_PRESSURE_OUT_OF_RANGE = 150, ///< FP filter health pressure out of range ALARM_ID_FP_PERMEATE_FLUSH_CONDUCTIVITY_TIMEOUT = 151, ///< FP membrane flush timeout - ALARM_ID_FP_CONCENTRATE_FLUSH_VOLUME_OUT_OF_RANGE = 152, ///< FP membrane flush integrated out of range + ALARM_ID_FP_CONCENTRATE_FLUSH_TANK_FULL_TIMEOUT = 152, ///< FP concentrate flush tank full timeout ALARM_ID_FP_GEN_PERMEATE_TANK_FULL_TIMEOUT = 153, ///< FP tank full time out alarm ALARM_ID_DD_DIALYSATE_TEMPERATURE_SENSORS_OUT_OF_RANGE = 154, ///< DD dialysate temperature sensors out of range ALARM_ID_DD_BLOOD_LEAK_DETECTED = 155, ///< DD blood leak detected @@ -485,7 +485,7 @@ { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_FILTER_HEALTH_PRESSURE_OUT_OF_RANGE }, // Priority Rank Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr AutoRes ClrOnly TxLog ID { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_PERMEATE_FLUSH_CONDUCTIVITY_TIMEOUT }, - { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_CONCENTRATE_FLUSH_VOLUME_OUT_OF_RANGE }, + { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_CONCENTRATE_FLUSH_TANK_FULL_TIMEOUT }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_GEN_PERMEATE_TANK_FULL_TIMEOUT }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_DIALYSATE_TEMPERATURE_SENSORS_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 150, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , TRUE , ALARM_ID_DD_BLOOD_LEAK_DETECTED }, @@ -606,7 +606,7 @@ { 110, ALARM_ID_FP_POWER_BUDGET_OUT_OF_RANGE }, { 110, ALARM_ID_FP_FILTER_HEALTH_PRESSURE_OUT_OF_RANGE }, { 110, ALARM_ID_FP_PERMEATE_FLUSH_CONDUCTIVITY_TIMEOUT }, - { 110, ALARM_ID_FP_CONCENTRATE_FLUSH_VOLUME_OUT_OF_RANGE }, + { 110, ALARM_ID_FP_CONCENTRATE_FLUSH_TANK_FULL_TIMEOUT }, { 110, ALARM_ID_FP_GEN_PERMEATE_TANK_FULL_TIMEOUT }, { 110, ALARM_ID_DD_DIALYSATE_TEMPERATURE_SENSORS_OUT_OF_RANGE }, { 110, ALARM_ID_DD_D76_PUMP_SPEED_CONTROL_ERROR }, @@ -840,7 +840,7 @@ // Num Alarm ID Device Display Title Instructions Alarm List Title Description Trigger Condition { 150 , ALARM_ID_FP_FILTER_HEALTH_PRESSURE_OUT_OF_RANGE , "FP | FP: Filter Health | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Filters: Pressure difference too high | FP pressure difference between the filters is too high | If the difference between M3 and P8 is ≥ 10 PSI after 2 minutes | "}, { 151 , ALARM_ID_FP_PERMEATE_FLUSH_CONDUCTIVITY_TIMEOUT , "FP | FP: Filter Health | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Filters: Permeate conductivity high | FP conductivity after flushing the system is too high | If P18 conductivity > 200 uS/cm after 120 seconds ± 150ms of flushing. | "}, - { 152 , ALARM_ID_FP_CONCENTRATE_FLUSH_VOLUME_OUT_OF_RANGE , "FP | FP: Filter Health | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Filters: Volume difference too high | FP volume difference between integrated flow and expected volume | If P7 is <90% of the target integrated volume ( 1L ) after 30 seconds ± 150ms of flushing. | "}, + { 152 , ALARM_ID_FP_CONCENTRATE_FLUSH_TANK_FULL_TIMEOUT , "FP | FP: Filter Health | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Filters: Volume difference too high | FP volume difference between integrated flow and expected volume | If P7 is <90% of the target integrated volume ( 1L ) after 30 seconds ± 150ms of flushing. | "}, { 153 , ALARM_ID_FP_GEN_PERMEATE_TANK_FULL_TIMEOUT , "FP | FP: Permeate Overfill | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Tank: Tank is too full | FP tank level is too high | If the float sensor reads high for at least 60 seconds | "}, { 154 , ALARM_ID_DD_DIALYSATE_TEMPERATURE_SENSORS_OUT_OF_RANGE , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: D28 and D30 Delta | DD dialysate temperature sensors drift timeout. | If D28 and D30 have drifted for more 1 C for a certain period of time. | "}, { 155 , ALARM_ID_DD_BLOOD_LEAK_DETECTED , "DD | Blood Leak | A blood leak has been detected. \n- Visually inspect dialysate return line for blood.\n- Press Resume/OK to proceed to the next step. Dialysate will\n remain in bypass. | Blood Stop: Dialyzer Blood Leak | DD blood leak detected alarm | If the blood leak is detected based on the blood leak status reported by the sensor. | "},