Index: AlarmDefs.h =================================================================== diff -u -rf23a62567aa86da41eb79ee8fdd97d8e58c92beb -rc3be414784df4406b4eacbb565e2d8d5d097eca8 --- AlarmDefs.h (.../AlarmDefs.h) (revision f23a62567aa86da41eb79ee8fdd97d8e58c92beb) +++ AlarmDefs.h (.../AlarmDefs.h) (revision c3be414784df4406b4eacbb565e2d8d5d097eca8) @@ -237,9 +237,9 @@ ALARM_ID_TD_UI_POST_TIMEOUT = 205, ///< TD UI POST failed ALARM_ID_TD_UI_COMPATIBILITY_ERROR = 206, ///< TD and UI software builds are not compatible ALARM_ID_TD_SAFETY_SHUTDOWN_POST_TEST_FAILED = 207, ///< TD POST Safety Shutdown failure - ALARM_ID_FW_RESERVED_208 = 208, ///< FW reserved for use - ALARM_ID_FW_RESERVED_209 = 209, ///< FW reserved for use - ALARM_ID_FW_RESERVED_210 = 210, ///< FW reserved for use + ALARM_ID_TD_INITIAL_BC_REV_PRIME_LIMIT_REACHED = 208, ///< TD initial rev blood circuit prime limit reached + ALARM_ID_TD_INITIAL_BC_REV_PRIME_TIMEOUT = 209, ///< TD initial blood circuit prime timeout + ALARM_ID_TD_PRIME_COMPLETE = 210, ///< TD prime complete ALARM_ID_FW_RESERVED_211 = 211, ///< FW reserved for use ALARM_ID_FW_RESERVED_212 = 212, ///< FW reserved for use ALARM_ID_TD_BP_SYSTOLIC_LOW = 213, ///< TD blood pressure systolic low @@ -285,19 +285,19 @@ ALARM_ID_FW_RESERVED_253 = 253, ///< FW reserved for use ALARM_ID_FW_RESERVED_254 = 254, ///< FW reserved for use ALARM_ID_FW_RESERVED_255 = 255, ///< FW reserved for use - ALARM_ID_FW_RESERVED_256 = 256, ///< FW reserved for use - ALARM_ID_FW_RESERVED_257 = 257, ///< FW reserved for use - ALARM_ID_FW_RESERVED_258 = 258, ///< FW reserved for use - ALARM_ID_FW_RESERVED_259 = 259, ///< FW reserved for use - ALARM_ID_FW_RESERVED_260 = 260, ///< FW reserved for use - ALARM_ID_FW_RESERVED_261 = 261, ///< FW reserved for use - ALARM_ID_FW_RESERVED_262 = 262, ///< FW reserved for use - ALARM_ID_FW_RESERVED_263 = 263, ///< FW reserved for use - ALARM_ID_FW_RESERVED_264 = 264, ///< FW reserved for use - ALARM_ID_FW_RESERVED_265 = 265, ///< FW reserved for use - ALARM_ID_FW_RESERVED_266 = 266, ///< FW reserved for use - ALARM_ID_FW_RESERVED_267 = 267, ///< FW reserved for use - ALARM_ID_FW_RESERVED_268 = 268, ///< FW reserved for use + ALARM_ID_TD_INVALID_TUBING_SET = 256, ///< TD invalid tubing set + ALARM_ID_TD_INSTALL_NEW_BLOOD_TUBING_SET = 257, ///< TD install new blood tubing set + ALARM_ID_TD_TUBING_SET_NOT_DETECTED = 258, ///< TD no tubing set detected + ALARM_ID_TD_TUBING_SET_AUTHENTICATION_TIMEOUT = 259, ///< TD tubing set authentication timeout + ALARM_ID_TD_PRESSURE_TOO_HIGH_TO_ZERO = 260, ///< TD pressure too high to zero + ALARM_ID_TD_VENOUS_PRESSURIZATION_TIMEOUT = 261, ///< TD venous pressurization timeout + ALARM_ID_TD_VENOUS_PRESSURE_DECAY = 262, ///< TD venous pressure decay failure + ALARM_ID_TD_VENOUS_PRESSURE_LEAK = 263, ///< TD venous pressure leak + ALARM_ID_TD_VENOUS_PRESSURE_RELIEF = 264, ///< TD venous pressure relief failure + ALARM_ID_TD_ARTERIAL_PRESSURIZATION_TIMEOUT = 265, ///< TD arterial pressurization timeout + ALARM_ID_TD_ARTERIAL_PRESSURE_DECAY = 266, ///< TD arterial pressure decay failure + ALARM_ID_TD_ARTERIAL_PRESSURE_LEAK = 267, ///< TD arterial pressure leak + ALARM_ID_TD_ARTERIAL_PRESSURE_RELIEF = 268, ///< TD arterial pressure relief failure ALARM_ID_FW_RESERVED_269 = 269, ///< FW reserved for use ALARM_ID_DD_PRE_GEN_CHAMBER_C_FILL_TIMEOUT = 270, ///< DD Pre Gen Chamber C fill timer ALARM_ID_DD_PRE_GEN_D9_PRESSURE = 271, ///< DD Pre Gen D9 pressure out of range @@ -520,7 +520,6 @@ { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_FPGA_COMM_TIMEOUT }, { ALARM_PRIORITY_HIGH, 1, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_ALARM_AUDIO_SELF_TEST_FAILURE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_VALVE_CONTROL_FAILURE }, - // Priority Rank Source Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr AutoRes ClrOnly TxLog ID { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_ARTERIAL_SENSOR_TIMEOUT_FAULT }, { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_VENOUS_SENSOR_TIMEOUT_FAULT }, @@ -645,10 +644,10 @@ { ALARM_PRIORITY_MEDIUM, 435, ALM_SRC_FP, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, TRUE , ALARM_ID_FP_INLET_PRESSURE_OUT_HIGH_RANGE }, { ALARM_PRIORITY_MEDIUM, 436, ALM_SRC_FP, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, TRUE , ALARM_ID_FP_INLET_CONDUCTIVITY_OUT_HIGH_RANGE }, { ALARM_PRIORITY_MEDIUM, 437, ALM_SRC_FP, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, TRUE , ALARM_ID_FP_INLET_CONDUCTIVITY_OUT_LOW_RANGE }, - { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_FP_RO_INLET_PRESSURE_OUT_HIGH_RANGE }, - { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_FP_RO_OUTLET_CONDUCTIVITY_HIGH_RANGE }, - { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_FP_RO_INLET_CONDUCTIVITY_HIGH_RANGE }, - { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_FP_REJECTION_RATIO_LOW_RANGE }, + { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, FALSE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_FP_RO_INLET_PRESSURE_OUT_HIGH_RANGE }, + { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, FALSE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_FP_RO_OUTLET_CONDUCTIVITY_HIGH_RANGE }, + { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, FALSE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_FP_RO_INLET_CONDUCTIVITY_HIGH_RANGE }, + { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, FALSE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_FP_REJECTION_RATIO_LOW_RANGE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_FP_INLET_PRESSURE_REGULATOR_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_FP_INLET_TEMPERATURE_OUT_CRITICAL_RANGE }, // Priority Rank Source Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr AutoRes ClrOnly TxLog ID @@ -661,11 +660,11 @@ { ALARM_PRIORITY_HIGH, 2, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DD_BLOOD_LEAK_SENSOR_EMBEDDED_MODE_FAILURE }, { ALARM_PRIORITY_HIGH, 2, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DD_BLOOD_LEAK_SENSOR_SET_POINT_SET_FAILURE }, { ALARM_PRIORITY_MEDIUM, 698, ALM_SRC_DD, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DD_BLOOD_LEAK_RECOVERING_PLEASE_WAIT, }, - { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_GEN_PERMEATE_TANK_FILL_TIMEOUT }, - { ALARM_PRIORITY_HIGH, 10, ALM_SRC_FP, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_INLET_PRESSURE_CRITICAL_OUT_RANGE }, - { ALARM_PRIORITY_HIGH, 10, ALM_SRC_FP, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_PERMEATE_FLOW_OUT_HIGH_RANGE }, - { ALARM_PRIORITY_HIGH, 10, ALM_SRC_FP, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_PERMEATE_FLOW_OUT_LOW_RANGE }, - { ALARM_PRIORITY_HIGH, 10, ALM_SRC_FP, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_INLET_PRESSURE_LOW_RANGE }, + { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, FALSE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_GEN_PERMEATE_TANK_FILL_TIMEOUT }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_FP, FALSE ,FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_INLET_PRESSURE_CRITICAL_OUT_RANGE }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_FP, FALSE ,FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_PERMEATE_FLOW_OUT_HIGH_RANGE }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_FP, FALSE ,FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_PERMEATE_FLOW_OUT_LOW_RANGE }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_FP, FALSE ,FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_INLET_PRESSURE_LOW_RANGE }, { ALARM_PRIORITY_HIGH, 13, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , ALARM_ID_TD_AIR_TRAP_LOWER_TIMEOUT }, { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_SYRINGE_PUMP_SELF_TEST_FAILURE }, { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_SYRINGE_PUMP_RUNNING_WHILE_BP_OFF_ERROR }, @@ -695,7 +694,7 @@ { ALARM_PRIORITY_HIGH, 110, ALM_SRC_TD, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_AUTO_LOAD_EJECT_HIGH_BP_TORQUE }, { ALARM_PRIORITY_HIGH, 206, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , ALARM_ID_TD_AIR_PUMP_STALL }, { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_CPU_RAM_ERROR }, - { ALARM_PRIORITY_HIGH, 10, ALM_SRC_DD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_CPU_RAM_ERROR }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_DD, FALSE ,TRUE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_CPU_RAM_ERROR }, { ALARM_PRIORITY_HIGH, 1, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_INTEGRITY_POST_TEST_FAILED }, { ALARM_PRIORITY_HIGH, 1, ALM_SRC_DD, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_INTEGRITY_POST_TEST_FAILED }, { ALARM_PRIORITY_HIGH, 202, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_SALINE_BAG_VOLUME_LOW_ALARM }, @@ -711,9 +710,9 @@ { ALARM_PRIORITY_HIGH, 1, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_UI_POST_TIMEOUT }, { ALARM_PRIORITY_HIGH, 1, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_UI_COMPATIBILITY_ERROR }, { ALARM_PRIORITY_HIGH, 1, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_SAFETY_SHUTDOWN_POST_TEST_FAILED }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_208 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_209 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_210 }, + { ALARM_PRIORITY_HIGH, 293, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_INITIAL_BC_REV_PRIME_LIMIT_REACHED }, + { ALARM_PRIORITY_HIGH, 294, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_INITIAL_BC_REV_PRIME_TIMEOUT }, + { ALARM_PRIORITY_LOW, 853, ALM_SRC_TD, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_PRIME_COMPLETE }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_211 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_212 }, { ALARM_PRIORITY_MEDIUM, 691, ALM_SRC_TD, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_BP_SYSTOLIC_LOW }, @@ -761,19 +760,19 @@ { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_253 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_254 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_255 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_256 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_257 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_258 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_259 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_260 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_261 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_262 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_263 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_264 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_265 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_266 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_267 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_268 }, + { ALARM_PRIORITY_LOW, 731, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_INVALID_TUBING_SET }, + { ALARM_PRIORITY_LOW, 718, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_INSTALL_NEW_BLOOD_TUBING_SET }, + { ALARM_PRIORITY_LOW, 719, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_TUBING_SET_NOT_DETECTED }, + { ALARM_PRIORITY_LOW, 720, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_TUBING_SET_AUTHENTICATION_TIMEOUT }, + { ALARM_PRIORITY_LOW, 721, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_PRESSURE_TOO_HIGH_TO_ZERO }, + { ALARM_PRIORITY_LOW, 722, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_VENOUS_PRESSURIZATION_TIMEOUT }, + { ALARM_PRIORITY_LOW, 723, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_VENOUS_PRESSURE_DECAY }, + { ALARM_PRIORITY_LOW, 724, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_VENOUS_PRESSURE_LEAK }, + { ALARM_PRIORITY_LOW, 725, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_VENOUS_PRESSURE_RELIEF }, + { ALARM_PRIORITY_LOW, 726, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_ARTERIAL_PRESSURIZATION_TIMEOUT }, + { ALARM_PRIORITY_LOW, 727, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_ARTERIAL_PRESSURE_DECAY }, + { ALARM_PRIORITY_LOW, 728, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_ARTERIAL_PRESSURE_LEAK }, + { ALARM_PRIORITY_LOW, 729, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_ARTERIAL_PRESSURE_RELIEF }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FW_RESERVED_269 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_DD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_PRE_GEN_CHAMBER_C_FILL_TIMEOUT }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_DD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_PRE_GEN_D9_PRESSURE }, @@ -840,8 +839,8 @@ { 1, ALARM_ID_TD_INTEGRITY_POST_TEST_FAILED }, { 1, ALARM_ID_DD_INTEGRITY_POST_TEST_FAILED }, { 1, ALARM_ID_TD_EJECTOR_POST_TEST_FAILED }, - { 1, ALARM_ID_TD_UI_POST_TIMEOUT }, - { 1, ALARM_ID_TD_UI_COMPATIBILITY_ERROR }, + { 1, ALARM_ID_TD_UI_POST_TIMEOUT }, + { 1, ALARM_ID_TD_UI_COMPATIBILITY_ERROR }, { 1, ALARM_ID_TD_SAFETY_SHUTDOWN_POST_TEST_FAILED }, { 2, ALARM_ID_DD_NVM_INVALID_SYSTEM_RECORD_CRC }, { 2, ALARM_ID_DD_NVM_INVALID_SERVICE_RECORD_CRC }, @@ -858,6 +857,12 @@ { 2, ALARM_ID_DD_NVM_INVALID_CAL_BICARB_CONCENTRATE }, { 2, ALARM_ID_DD_NVM_INVALID_CAL_ACCEL_SENSOR }, { 2, ALARM_ID_DD_NVM_INVALID_CAL_BLOOD_LEAK_SENSOR }, + { 2, ALARM_ID_DD_NVM_INVALID_CAL_CONDUCTIVITY_SENSOR }, + { 2, ALARM_ID_DD_NVM_INVALID_INSTIT_BASIC_RECORD_CRC }, + { 2, ALARM_ID_DD_NVM_INVALID_INSTIT_ADVANCED_RECORD_CRC }, + { 2, ALARM_ID_DD_NVM_INVALID_INSTIT_ADDITIONAL_RECORD_CRC }, + { 2, ALARM_ID_FP_NVM_INVALID_SERVICE_RECORD_CRC }, + { 2, ALARM_ID_FP_NVM_INVALID_USAGE_RECORD_CRC }, { 10, ALARM_ID_TD_SOFTWARE_FAULT }, { 10, ALARM_ID_TD_UI_COMM_TIMEOUT }, { 10, ALARM_ID_TD_COMM_TOO_MANY_BAD_CRCS }, @@ -991,6 +996,8 @@ { 290, ALARM_ID_TD_BLOOD_SITTING_WARNING }, { 291, ALARM_ID_TD_BLOOD_PRIME_PAUSE_TIMEOUT }, { 292, ALARM_ID_TD_BLOOD_PRIME_PAUSE_WARNING }, + { 293, ALARM_ID_TD_INITIAL_BC_REV_PRIME_LIMIT_REACHED }, + { 294, ALARM_ID_TD_INITIAL_BC_REV_PRIME_TIMEOUT }, { 300, ALARM_ID_TD_TREATMENT_STOPPED_BY_USER }, { 300, ALARM_ID_TD_TUBE_SET_MISMATCH }, { 401, ALARM_ID_DD_DIALYSATE_TEMP_ABOVE_SAFETY_TEMP }, @@ -1017,11 +1024,25 @@ { 715, ALARM_ID_TD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM }, { 716, ALARM_ID_TD_SYRINGE_PUMP_OCCLUSION }, { 717, ALARM_ID_TD_PRE_TX_HEPARIN_LOAD_SYRINGE }, + { 718, ALARM_ID_TD_INSTALL_NEW_BLOOD_TUBING_SET }, + { 719, ALARM_ID_TD_TUBING_SET_NOT_DETECTED }, + { 720, ALARM_ID_TD_TUBING_SET_AUTHENTICATION_TIMEOUT }, + { 721, ALARM_ID_TD_PRESSURE_TOO_HIGH_TO_ZERO }, + { 722, ALARM_ID_TD_VENOUS_PRESSURIZATION_TIMEOUT }, + { 723, ALARM_ID_TD_VENOUS_PRESSURE_DECAY }, + { 724, ALARM_ID_TD_VENOUS_PRESSURE_LEAK }, + { 725, ALARM_ID_TD_VENOUS_PRESSURE_RELIEF }, + { 726, ALARM_ID_TD_ARTERIAL_PRESSURIZATION_TIMEOUT }, + { 727, ALARM_ID_TD_ARTERIAL_PRESSURE_DECAY }, + { 728, ALARM_ID_TD_ARTERIAL_PRESSURE_LEAK }, + { 729, ALARM_ID_TD_ARTERIAL_PRESSURE_RELIEF }, { 730, ALARM_ID_TD_SYRINGE_PUMP_SYRINGE_EMPTY }, + { 731, ALARM_ID_TD_INVALID_TUBING_SET }, { 745, ALARM_ID_TD_SYRINGE_DETECTED }, { 746, ALARM_ID_TD_RECIRC_TIMEOUT_WARNING }, { 850, ALARM_ID_BATTERY_LOW }, { 852, ALARM_ID_TD_AC_POWER_LOST }, + { 853, ALARM_ID_TD_PRIME_COMPLETE }, { 999, ALARM_ID_DD_AVAILABLE_1 }, { 999, ALARM_ID_DD_AVAILABLE_2 }, { 999, ALARM_ID_UI_RESERVED_116 }, @@ -1042,9 +1063,6 @@ { 999, ALARM_ID_FW_RESERVED_202 }, { 999, ALARM_ID_FW_RESERVED_203 }, { 999, ALARM_ID_FW_RESERVED_204 }, - { 999, ALARM_ID_FW_RESERVED_208 }, - { 999, ALARM_ID_FW_RESERVED_209 }, - { 999, ALARM_ID_FW_RESERVED_210 }, { 999, ALARM_ID_FW_RESERVED_211 }, { 999, ALARM_ID_FW_RESERVED_212 }, { 999, ALARM_ID_FW_RESERVED_219 }, @@ -1067,19 +1085,6 @@ { 999, ALARM_ID_FW_RESERVED_253 }, { 999, ALARM_ID_FW_RESERVED_254 }, { 999, ALARM_ID_FW_RESERVED_255 }, - { 999, ALARM_ID_FW_RESERVED_256 }, - { 999, ALARM_ID_FW_RESERVED_257 }, - { 999, ALARM_ID_FW_RESERVED_258 }, - { 999, ALARM_ID_FW_RESERVED_259 }, - { 999, ALARM_ID_FW_RESERVED_260 }, - { 999, ALARM_ID_FW_RESERVED_261 }, - { 999, ALARM_ID_FW_RESERVED_262 }, - { 999, ALARM_ID_FW_RESERVED_263 }, - { 999, ALARM_ID_FW_RESERVED_264 }, - { 999, ALARM_ID_FW_RESERVED_265 }, - { 999, ALARM_ID_FW_RESERVED_266 }, - { 999, ALARM_ID_FW_RESERVED_267 }, - { 999, ALARM_ID_FW_RESERVED_268 }, { 999, ALARM_ID_FW_RESERVED_269 }, { 999, ALARM_ID_DD_PRE_GEN_CHAMBER_C_FILL_TIMEOUT }, { 999, ALARM_ID_DD_PRE_GEN_D9_PRESSURE }, @@ -1306,7 +1311,7 @@ { 162 , ALARM_ID_FP_PERMEATE_FLOW_OUT_HIGH_RANGE , "FP | High Permeate flow | Permeate flow is too high. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Fault: Permeate flow High | Permeate flow is too high from set target flow rate | If the permeate flow is above 25% of set target flow rate for a certain period of time. | "}, { 163 , ALARM_ID_FP_PERMEATE_FLOW_OUT_LOW_RANGE , "FP | low Permeate flow | Permeate flow is too low. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Fault: Permeate flow Low | Permeate flow is too low from set target flow rate | If the permeate flow is above 25% of set target flow rate for a certain period of time. | "}, { 164 , ALARM_ID_FP_INLET_PRESSURE_LOW_RANGE , "FP | low inlet pressure | Inlet pressure is too low. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Fault: Inlet pressure Low | Inlet pressure is too low | If P8 is < 1 PSI | "}, - { 165 , ALARM_ID_TD_AIR_TRAP_LOWER_TIMEOUT , "TD | Blood Pump Stopped: Venous Air Detector | A problem was detected with the venous air detector.\n- Confirm arterial access placement and ensure\nconnections are secure.\n- Treatment must be terminated without rinseback. | Blood Stop: Air Trap Lowering | Air trap lowering timeout during treatment | If the air trap lowering timeout during treatment. | "}, + { 165 , ALARM_ID_TD_AIR_TRAP_LOWER_TIMEOUT , "TD | Blood Pump Stopped: Venous Air Detector | A problem was detected with the venous air detector.\n- Confirm arterial access placement and ensure\nconnections are secure.\n- Treatment must be terminated without rinseback. | Blood Stop: Air Trap Lowering | Air trap lowering timeout during treatment | If the air trap lowering timeout during treatment. | "}, { 166 , ALARM_ID_TD_SYRINGE_PUMP_SELF_TEST_FAILURE , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe DAC | TD syringe pump self-test failure alarm | If the calibration data that was received from NVDataMgmt and the DAC voltage with syringe retracted are not within tol. | "}, { 167 , ALARM_ID_TD_SYRINGE_PUMP_RUNNING_WHILE_BP_OFF_ERROR , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe Pump On Err | TD syringe pump is running while the BP is off | If the syringe pump is on while the blood pump is off | "}, { 168 , ALARM_ID_TD_SYRINGE_PUMP_FPGA_ADC_FAULT , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe Pump ADC Com | TD syringe pump ADC error | If the ADC read is not fresh after POST init and the ADC read counter has not changed. | "}, @@ -1351,9 +1356,9 @@ { 205 , ALARM_ID_TD_UI_POST_TIMEOUT , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD POST: UI POST Timeout | TD UI POST timeout failure | If the UI POST process does not complete within the expected time. | "}, { 206 , ALARM_ID_TD_UI_COMPATIBILITY_ERROR , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD POST: UI Compatibility Error | TD and UI software builds are not compatible | If the UI software version is not compatible with the TD software version. | "}, { 207 , ALARM_ID_TD_SAFETY_SHUTDOWN_POST_TEST_FAILED , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Safety Shutdown Failure | TD safety shutdown POST test failed | If the 24V actuator supply does not turn off during safety shutdown, or if the 24V actuator supply does not recover after safety shutdown is cleared. | "}, - { 208 , ALARM_ID_FW_RESERVED_208 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 209 , ALARM_ID_FW_RESERVED_209 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 210 , ALARM_ID_FW_RESERVED_210 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, + { 208 , ALARM_ID_TD_INITIAL_BC_REV_PRIME_LIMIT_REACHED , "TD | Prime Paused: Check Saline Line | The system has repeatedly paused priming to relieve negative pressure in the venous line.\n- Check that the saline line is not clamped or kinked.\n- Check that the saline bag is not empty.\n- Resume priming once checked, or end treatment. | Prime: BC: Venous Line, Retry Limit | Venous pressure (H14) reached the neg pressure pause limit, possibly indicating a clamped or occluded saline/H14 line. | During Blood Circuit: Venous Line prime state, when the negative pressure pause/equalize cycle has occurred 3 times. | "}, + { 209 , ALARM_ID_TD_INITIAL_BC_REV_PRIME_TIMEOUT , "TD | Prime Timeout: Venous Line | Priming the venous line and air trap did not complete within the expected time.\n- Check the saline line and connections.\n- Resume priming, or end treatment. | Prime: BC: Venous Line, Timeout | Blood Circuit: Venous Line state failed to complete within 40 seconds, excluding time spent paused for pressure equalization. | During Blood Circuit: Venous Line prime state, when the state has been active for more than 40 seconds, excluding paused time. | "}, + { 210 , ALARM_ID_TD_PRIME_COMPLETE , "TD | Prime Complete | Priming completed, click ok to enter rx. | TD prime complete | | Prime completed | "}, { 211 , ALARM_ID_FW_RESERVED_211 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 212 , ALARM_ID_FW_RESERVED_212 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 213 , ALARM_ID_TD_BP_SYSTOLIC_LOW , "TD | Blood Stopped: Systolic BP Low | The patient's systolic blood pressure is below the configured low limit.\n- Verify patient condition.\n- Check blood pressure cuff placement.\n- Repeat blood pressure measurement if necessary. | Process: Blood Pressure Monitoring | Patient systolic blood pressure below configured low threshold | Triggered when systolic blood pressure is below the configured low limit. | "}, @@ -1401,19 +1406,19 @@ { 253 , ALARM_ID_FW_RESERVED_253 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 254 , ALARM_ID_FW_RESERVED_254 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 255 , ALARM_ID_FW_RESERVED_255 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 256 , ALARM_ID_FW_RESERVED_256 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 257 , ALARM_ID_FW_RESERVED_257 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 258 , ALARM_ID_FW_RESERVED_258 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 259 , ALARM_ID_FW_RESERVED_259 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 260 , ALARM_ID_FW_RESERVED_260 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 261 , ALARM_ID_FW_RESERVED_261 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 262 , ALARM_ID_FW_RESERVED_262 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 263 , ALARM_ID_FW_RESERVED_263 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 264 , ALARM_ID_FW_RESERVED_264 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 265 , ALARM_ID_FW_RESERVED_265 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 266 , ALARM_ID_FW_RESERVED_266 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 267 , ALARM_ID_FW_RESERVED_267 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, - { 268 , ALARM_ID_FW_RESERVED_268 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, + { 256 , ALARM_ID_TD_INVALID_TUBING_SET , "TD | Invalid Blood Tubing Set | A problem has been detected during self-test.\n- The installed blood tubing set is not valid.\n- Install a valid blood tubing set intended for the selected treatment modality. | Process: Pre-Tx Dry Self-Test | TD detected invalid tubing set during authentication | If authentication response indicates the tubing set is invalid. | "}, + { 257 , ALARM_ID_TD_INSTALL_NEW_BLOOD_TUBING_SET , "TD | Install New Blood Tubing Set | A problem has been detected during self-test.\n- Fluid detected in the tubing set or no valid tubing set installed.\n- Install a new, unused blood tubing set and ensure proper installation. | Process: Pre-Tx Dry Self-Test | TD detected used, wet, or missing blood tubing set | If bubble is detected, air trap levels indicate fluid, or barcode scan fails. | "}, + { 258 , ALARM_ID_TD_TUBING_SET_NOT_DETECTED , "TD | No Blood Tubing Set Detected | A problem has been detected during self-test.\n- No blood tubing set detected in the system.\n- Install a blood tubing set and ensure proper placement. | Process: Pre-Tx Dry Self-Test | TD did not detect tubing set during verification | If no tubing set is detected during tube set loaded check. | "}, + { 259 , ALARM_ID_TD_TUBING_SET_AUTHENTICATION_TIMEOUT , "TD | Tubing Set Authentication Timeout | A problem has been detected during self-test.\n- Authentication response not received.\n- Retry or check system communication. | Process: Pre-Tx Dry Self-Test | TD did not receive authentication response from UI | If no authentication response is received within timeout period. | "}, + { 260 , ALARM_ID_TD_PRESSURE_TOO_HIGH_TO_ZERO , "TD | Pressure Too High to Zero | A problem has been detected during self-test.\n- Pressure levels are too high to perform sensor zeroing.\n- Ensure system is open to atmosphere and retry. | Process: Pre-Tx Dry Self-Test | TD detected high pressure during zeroing | If arterial or venous pressure ≥ 15 mmHg during pressure sensor normal setup. | "}, + { 261 , ALARM_ID_TD_VENOUS_PRESSURIZATION_TIMEOUT , "TD | Venous Pressurization Timeout | A problem has been detected during self-test.\n- Venous pressure did not reach required level.\n- Check tubing connections and system integrity. | Process: Pre-Tx Dry Self-Test | TD failed to reach venous pressure target | If venous pressure does not reach threshold within allowed time. | "}, + { 262 , ALARM_ID_TD_VENOUS_PRESSURE_DECAY , "TD | Venous Pressure Decay | A problem has been detected during self-test.\n- Venous pressure dropped more than expected.\n- Check for leaks or loose connections. | Process: Pre-Tx Dry Self-Test | TD detected excessive venous pressure decay | If venous pressure reduction exceeds allowed tolerance during stabilization. | "}, + { 263 , ALARM_ID_TD_VENOUS_PRESSURE_LEAK , "TD | Venous Pressure Leak | A problem has been detected during self-test.\n- Possible leak in venous line.\n- Inspect tubing and connections. | Process: Pre-Tx Dry Self-Test | TD detected venous pressure leak | If venous pressure difference exceeds tolerance during leak check. | "}, + { 264 , ALARM_ID_TD_VENOUS_PRESSURE_RELIEF , "TD | Venous Pressure Relief Failure | A problem has been detected during self-test.\n- Pressure did not return to baseline.\n- Ensure valves and tubing are functioning properly. | Process: Pre-Tx Dry Self-Test | TD failed venous pressure relief check | If venous pressure does not return within ±5 mmHg after relief. | "}, + { 265 , ALARM_ID_TD_ARTERIAL_PRESSURIZATION_TIMEOUT , "TD | Arterial Pressurization Timeout | A problem has been detected during self-test.\n- Arterial pressure did not reach required level.\n- Check tubing and pump operation. | Process: Pre-Tx Dry Self-Test | TD failed to reach arterial pressure target | If arterial pressure does not reach threshold within allowed time. | "}, + { 266 , ALARM_ID_TD_ARTERIAL_PRESSURE_DECAY , "TD | Arterial Pressure Decay | A problem has been detected during self-test.\n- Arterial pressure dropped more than expected.\n- Check for leaks or loose connections. | Process: Pre-Tx Dry Self-Test | TD detected excessive arterial pressure decay | If arterial pressure reduction exceeds allowed tolerance during stabilization. | "}, + { 267 , ALARM_ID_TD_ARTERIAL_PRESSURE_LEAK , "TD | Arterial Pressure Leak | A problem has been detected during self-test.\n- Possible leak in arterial line.\n- Inspect tubing and connections. | Process: Pre-Tx Dry Self-Test | TD detected arterial pressure leak | If arterial pressure difference exceeds tolerance during leak check. | "}, + { 268 , ALARM_ID_TD_ARTERIAL_PRESSURE_RELIEF , "TD | Arterial Pressure Relief Failure | A problem has been detected during self-test.\n- Pressure did not return to baseline.\n- Ensure valves and tubing are functioning properly. | Process: Pre-Tx Dry Self-Test | TD failed arterial pressure relief check | If arterial pressure does not return within ±5 mmHg after relief. | "}, { 269 , ALARM_ID_FW_RESERVED_269 , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 270 , ALARM_ID_DD_PRE_GEN_CHAMBER_C_FILL_TIMEOUT , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "}, { 271 , ALARM_ID_DD_PRE_GEN_D9_PRESSURE , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: RESERVED | RESERVED | RESERVED | "},