Index: AlarmDefs.h =================================================================== diff -u -rffe968d36207b80678a9fd77a834f48f7d3b5aed -rd76bbd9407890ea3b2b209f7f13adbbd75958263 --- AlarmDefs.h (.../AlarmDefs.h) (revision ffe968d36207b80678a9fd77a834f48f7d3b5aed) +++ AlarmDefs.h (.../AlarmDefs.h) (revision d76bbd9407890ea3b2b209f7f13adbbd75958263) @@ -225,6 +225,7 @@ ALARM_ID_DD_CPU_RAM_ERROR = 193, ///< DD CPU RAM error ALARM_ID_TD_INTEGRITY_POST_TEST_FAILED = 194, ///< TD integrity post test fault ALARM_ID_DD_INTEGRITY_POST_TEST_FAILED = 195, ///< TD integrity post test fault + ALARM_ID_TD_EMPTY_SALINE_BAG = 196, ///< TD empty saline bag alarm NUM_OF_ALARM_IDS ///< Number of alarms }; typedef enum Alarm_List ALARM_ID_T; ///< Type for alarm list enumeration @@ -568,6 +569,7 @@ { ALARM_PRIORITY_HIGH, 10, ALM_SRC_DD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_CPU_RAM_ERROR }, { ALARM_PRIORITY_HIGH, 1, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_INTEGRITY_POST_TEST_FAILED }, { ALARM_PRIORITY_HIGH, 1, ALM_SRC_DD, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_INTEGRITY_POST_TEST_FAILED }, + { ALARM_PRIORITY_HIGH, 202, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_EMPTY_SALINE_BAG }, }; // Priority Rank Source Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr AutoRes ClrOnly TxLog ID /// Table of alarms and their rank. @@ -720,6 +722,7 @@ { 150, ALARM_ID_DD_BLOOD_LEAK_DETECTED }, { 200, ALARM_ID_TD_VENOUS_PRESSURE_LOW }, { 201, ALARM_ID_TD_VENOUS_PRESSURE_HIGH }, + { 202, ALARM_ID_TD_EMPTY_SALINE_BAG }, { 202, ALARM_ID_TD_ARTERIAL_PRESSURE_LOW }, { 203, ALARM_ID_TD_ARTERIAL_PRESSURE_HIGH }, { 204, ALARM_ID_TD_TMP_PRESSURE_LOW }, @@ -994,6 +997,7 @@ { 193 , ALARM_ID_DD_CPU_RAM_ERROR , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD CPU RAM error | DD CPU RAM check failure | If the RAM status indicates any of the following: Double bit error, Address decode failure, Address decode logic element failure, Read address parity failure, Write address parity failure. | "}, { 194 , ALARM_ID_TD_INTEGRITY_POST_TEST_FAILED , "TD | Service Required: Hemodialysis Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Firmware Image Integrity Failure | TD firmware image integrity POST test failed | If the calculated CRC of the TD image does not match the expected CRC. | "}, { 195 , ALARM_ID_DD_INTEGRITY_POST_TEST_FAILED , "DD | Service Required: Hemodialysis Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Firmware Image Integrity Failure | DD firmware image integrity POST test failed | If the calculated CRC of the DD image does not match the expected CRC. | "}, + { 196 , ALARM_ID_TD_EMPTY_SALINE_BAG , "TD | Blood Pump Stopped: Saline Bag Empty | The saline bag appears empty.\n- Check the saline bag and replace if empty. | Blood Stop: Saline Bag Empty | TD Saline bag is empty | If the measured arterial pressure < -300.0 mmHg for more than 250 msec. | "}, }; #endif // manual alarms