Index: MsgDefs.h =================================================================== diff -u -r38fca679ac07fa6a16fc4b756aebb4e3f95e207a -r0add9fc32d9990da9c06208d3a40445bda885ee9 --- MsgDefs.h (.../MsgDefs.h) (revision 38fca679ac07fa6a16fc4b756aebb4e3f95e207a) +++ MsgDefs.h (.../MsgDefs.h) (revision 0add9fc32d9990da9c06208d3a40445bda885ee9) @@ -8,8 +8,8 @@ * * @file MsgDefs.h * -* @author (last) Sameer Kalliadan Poyil -* @date (last) 29-Apr-2026 +* @author (last) Arpita Srivastava +* @date (last) 18-May-2026 * * @author (original) Sean Nash * @date (original) 01-Aug-2024 @@ -195,6 +195,19 @@ MSG_ID_UI_WATER_SAMPLE_RESULT_REQUEST = 0xA3, ///< UI water sample result request MSG_ID_UI_PRESSURE_LIMIT_WIDEN_REQUEST = 0xA4, ///< UI pressure limit widen request. MSG_ID_TD_PRESSURE_LIMIT_WIDEN_RESPONSE = 0xA5, ///< TD pressure limit widen response. + MSG_ID_UI_RECIRCULATE_REQUEST = 0xA6, ///< UI recirculate request + MSG_ID_TD_RECIRCULATE_RESPONSE = 0xA7, ///< TD recirculate response + MSG_ID_TD_RECIRCULATE_DATA = 0xA8, ///< TD recirculate data + MSG_ID_UI_ADJUST_TREATMENT_LOGS_REQUEST = 0xA9, ///< UI adjust treatment logs request. + MSG_ID_TD_ADJUST_TREATMENT_LOGS_RESPONSE = 0xAA, ///< TD adjust treatment logs response + MSG_ID_UI_ADJUST_PATIENT_DISCONNECT_CONFIRM_REQUEST = 0xAB, ///< UI adjust patient disconnect confirm request + MSG_ID_TD_ADJUST_PATIENT_DISCONNECT_CONFIRM_RESPONSE = 0xAC, ///< TD adjust patient disconnect confirm response + MSG_ID_TD_DRY_SELF_TEST_PROGRESS_DATA = 0xAD, ///< TD dry self test progress data + MSG_ID_TD_TUBING_SET_BARCODE_SCAN_REQUEST = 0xAE, ///< TD tube set authentication request + MSG_ID_TD_TUBE_SET_AUTHENTICATION_REQUEST = 0xAF, ///< UI tube set authentication acknowledge request + MSG_ID_TD_TUBE_SET_AUTHENTICATION_ACK_RESPONSE = 0xB0, ///< TD tube set authentication acknowledge response + MSG_ID_TD_SYRINGE_PUMP_DATA = 0xB1, ///< TD broadcast of syringe pump data + MSG_ID_TD_HEPARIN_PAUSE_RESUME_RESPONSE= 0xB2, ///< TD response to pause/resume Heparin delivery request // service/test CAN messages MSG_ID_FIRST_TD_TESTER_MESSAGE = 0x8000, ///< First TD test message ID @@ -270,6 +283,19 @@ MSG_ID_TD_BLOOD_PRIME_VOLUME_OVERRIDE = 0x8045, ///< TD blood prime override. MSG_ID_TD_BLOOD_PRIME_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0x8046, ///< TD blood prime publish interval broadcast override. MSG_ID_TD_ENABLE_VENOUS_BUBBLE_ALARM = 0x8047, ///< TD enable venous bubble alarm. + MSG_ID_TD_SYRINGE_PUMP_OPERATION_REQUEST = 0x8048, ///< TD syringe pump operation request + MSG_ID_HD_SYRINGE_PUMP_PUBLISH_INTERVAL_OVERRIDE = 0x8049, ///< TD syringe pump data publish interval override request + MSG_ID_TD_SYRINGE_PUMP_RATE_OVERRIDE_REQUEST = 0x8050, ///< TD syringe pump measured rate override request + MSG_ID_TD_SYRINGE_PUMP_FORCE_OVERRIDE_REQUEST = 0x8051, ///< TD syringe pump measured force override request + MSG_ID_TD_SYRINGE_PUMP_HOME_OVERRIDE_REQUEST = 0x8052, ///< TD syringe pump measured home override request + MSG_ID_TD_SYRINGE_PUMP_POSITION_OVERRIDE_REQUEST = 0x8053, ///< TD syringe pump measured position override request + MSG_ID_TD_SYRINGE_PUMP_VOLUME_OVERRIDE_REQUEST = 0x8054, ///< TD syringe pump measured volume override request + MSG_ID_TD_SYRINGE_PUMP_STATUS_OVERRIDE_REQUEST = 0x8055, ///< TD syringe pump status override request + MSG_ID_TD_SYRINGE_PUMP_ENCODER_STATUS_OVERRIDE_REQUEST = 0x8056, ///< TD syringe pump Encoder status override request + MSG_ID_TD_SYRINGE_PUMP_ADC_DAC_STATUS_OVERRIDE_REQUEST = 0x8057, ///< TD syringe pump ADC and DAC status override request + MSG_ID_TD_SYRINGE_PUMP_ADC_READ_COUNTER_OVERRIDE_REQUEST = 0x8058, ///< TD syringe pump ADC read counter override request + MSG_ID_TD_HEPARIN_BOLUS_TARGET_RATE_OVERRIDE_REQUEST = 0x8059, ///< TD heparin bolus target rate override request + MSG_ID_TD_SYRINGE_PUMP_FORCE_SENSOR_CALIBRATION_REQUEST = 0x8060, ///< TD set syringe pump force sensor DAC calibration request MSG_ID_FIRST_DD_TESTER_MESSAGE = 0xA000, ///< First DD test message ID MSG_ID_DD_TESTER_LOGIN_REQUEST = MSG_ID_FIRST_DD_TESTER_MESSAGE, ///< DD tester log-in @@ -532,8 +558,9 @@ REQUEST_REJECT_REASON_ACID_CONV_FACTOR_MISMATCH = 54, ///< Acid conversion factor from UI mismatch with FW REQUEST_REJECT_REASON_INVALID_PATIENT_WEIGHTS = 55, ///< Patient pre and estimated target weights are invalid REQUEST_REJECT_REASON_UF_VOL_AND_WEIGHTS_INCONSISTENT = 56, ///< UF volume and the patient weights are not consistent - REQUEST_REJECT_REASON_CONFIRMATION_NOT_EXPECTED = 57, ///< Confirmation received without prior validation - REQUEST_REJECT_REASON_CONFIRMATION_MISMATCH = 58, ///< Confirmed value does not match validated value + REQUEST_REJECT_REASON_TD_AUTHENTICATION_INVALID = 57, ///< TD authentication invalid + REQUEST_REJECT_REASON_CONFIRMATION_NOT_EXPECTED = 58, ///< Confirmation received without prior validation + REQUEST_REJECT_REASON_CONFIRMATION_MISMATCH = 59, ///< Confirmed value does not match validated value NUM_OF_REQUEST_REJECT_REASONS ///< Number of settings change reject codes }; typedef enum Request_Reject_Reasons REQUEST_REJECT_REASON_CODE_T; ///< Type for settings change rejection reason codes enumeration