Index: MsgDefs.h =================================================================== diff -u -r57be07b7d65de128135bc3ae455d204e1b7c6fa6 -r3306527af4721b12ce9009ddc5346b71ea3464a3 --- MsgDefs.h (.../MsgDefs.h) (revision 57be07b7d65de128135bc3ae455d204e1b7c6fa6) +++ MsgDefs.h (.../MsgDefs.h) (revision 3306527af4721b12ce9009ddc5346b71ea3464a3) @@ -195,8 +195,8 @@ MSG_ID_UI_WATER_SAMPLE_RESULT_REQUEST = 0xA3, ///< UI water sample result request MSG_ID_UI_PRESSURE_LIMIT_WIDEN_REQUEST = 0xA4, ///< UI pressure limit widen request. MSG_ID_TD_PRESSURE_LIMIT_WIDEN_RESPONSE = 0xA5, ///< TD pressure limit widen response. - MSG_ID_TD_SYRINGE_PUMP_DATA = 0xA6, ///< TD broadcast of syringe pump data - MSG_ID_TD_HEPARIN_PAUSE_RESUME_RESPONSE= 0xA7, ///< TD response to pause/resume Heparin delivery request + MSG_ID_TD_SYRINGE_PUMP_DATA = 0xA9, ///< TD broadcast of syringe pump data + MSG_ID_TD_HEPARIN_PAUSE_RESUME_RESPONSE= 0xA10, ///< TD response to pause/resume Heparin delivery request // service/test CAN messages MSG_ID_FIRST_TD_TESTER_MESSAGE = 0x8000, ///< First TD test message ID @@ -272,6 +272,20 @@ MSG_ID_TD_BLOOD_PRIME_VOLUME_OVERRIDE = 0x8045, ///< TD blood prime override. MSG_ID_TD_BLOOD_PRIME_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0x8046, ///< TD blood prime publish interval broadcast override. MSG_ID_TD_ENABLE_VENOUS_BUBBLE_ALARM = 0x8047, ///< TD enable venous bubble alarm. + MSG_ID_TD_SYRINGE_PUMP_OPERATION_REQUEST = 0x8048, ///< TD syringe pump operation request + MSG_ID_HD_SYRINGE_PUMP_PUBLISH_INTERVAL_OVERRIDE = 0x8049, ///< TD syringe pump data publish interval override request + MSG_ID_TD_SYRINGE_PUMP_RATE_OVERRIDE_REQUEST = 0x8050, ///< TD syringe pump measured rate override request + MSG_ID_TD_SYRINGE_PUMP_FORCE_OVERRIDE_REQUEST = 0x8051, ///< TD syringe pump measured force override request + MSG_ID_TD_SYRINGE_PUMP_SYRINGE_DETECT_OVERRIDE_REQUEST = 0x8052, ///< TD syringe pump measured syringe detection switch override request + MSG_ID_TD_SYRINGE_PUMP_HOME_OVERRIDE_REQUEST = 0x8053, ///< TD syringe pump measured home override request + MSG_ID_TD_SYRINGE_PUMP_POSITION_OVERRIDE_REQUEST = 0x8054, ///< TD syringe pump measured position override request + MSG_ID_TD_SYRINGE_PUMP_VOLUME_OVERRIDE_REQUEST = 0x8055, ///< TD syringe pump measured volume override request + MSG_ID_TD_SYRINGE_PUMP_STATUS_OVERRIDE_REQUEST = 0x8056, ///< TD syringe pump status override request + MSG_ID_TD_SYRINGE_PUMP_ENCODER_STATUS_OVERRIDE_REQUEST = 0x8057, ///< TD syringe pump Encoder status override request + MSG_ID_TD_SYRINGE_PUMP_ADC_DAC_STATUS_OVERRIDE_REQUEST = 0x8058, ///< TD syringe pump ADC and DAC status override request + MSG_ID_TD_SYRINGE_PUMP_ADC_READ_COUNTER_OVERRIDE_REQUEST = 0x8059, ///< TD syringe pump ADC read counter override request + MSG_ID_TD_SYRINGE_PUMP_FORCE_SENSOR_DAC_OVERRIDE_REQUEST = 0x8060, ///< TD set syringe pump force sensor DAC calibration override request + MSG_ID_TD_HEPARIN_BOLUS_TARGET_RATE_OVERRIDE_REQUEST = 0x8061, ///< TD heparin bolus target rate override request MSG_ID_FIRST_DD_TESTER_MESSAGE = 0xA000, ///< First DD test message ID MSG_ID_DD_TESTER_LOGIN_REQUEST = MSG_ID_FIRST_DD_TESTER_MESSAGE, ///< DD tester log-in