Index: MsgDefs.h =================================================================== diff -u -r8f341c5fe87f7f4dbf8a0aeddf785414406b1882 -r190faf446fb81b91377fd7d7404ca6a0bf6f1242 --- MsgDefs.h (.../MsgDefs.h) (revision 8f341c5fe87f7f4dbf8a0aeddf785414406b1882) +++ MsgDefs.h (.../MsgDefs.h) (revision 190faf446fb81b91377fd7d7404ca6a0bf6f1242) @@ -9,7 +9,7 @@ * @file MsgDefs.h * * @author (last) Vijay Pamula -* @date (last) 28-May-2026 +* @date (last) 12-Jun-2026 * * @author (original) Sean Nash * @date (original) 01-Aug-2024 @@ -90,7 +90,7 @@ MSG_ID_FP_HEATER_DATA = 0x3A, ///< FP heater data broadcast MSG_ID_TD_TREATMENT_TIME_DATA = 0x3B, ///< TD treatment time data broadcast MSG_ID_TD_TREATMENT_STATE_DATA = 0x3C, ///< TD treatment state data broadcast - MSG_ID_TD_SALINE_BOLUS_DATA = 0x3D, ///< TD saline bolus status data broadcast + MSG_ID_TD_FLUID_BOLUS_DATA = 0x3D, ///< TD fluid bolus status data broadcast MSG_ID_TD_ULTRAFILTRATION_DATA = 0x3E, ///< TD ultrafiltration status data broadcast MSG_ID_UI_TREATMENT_PARAMS_TO_VALIDATE = 0x3F, ///< UI treatment parameters to be validated by TD MSG_ID_TD_RESP_TREATMENT_PARAMS_TO_VALIDATE = 0x40, ///< TD response to treatment parameter validation request @@ -124,8 +124,8 @@ MSG_ID_DD_UF_DATA = 0x5C, ///< DD ultrafiltration data MSG_ID_FP_PERMEATE_TANK_DATA = 0x5D, ///< FP Permeate tank broadcast data MSG_ID_DD_SPENT_CHAMBER_FILL_DATA = 0x5E, ///< DD spent chamber fill broadcast data - MSG_ID_UI_SOLUTION_INFUSION_REQUEST = 0x5F, ///< UI solution infusion request - MSG_ID_TD_SOLUTION_INFUSION_RESPONSE = 0x60, ///< TD solution infusion response + MSG_ID_UI_FLUID_BOLUS_REQUEST = 0x5F, ///< UI Fluid Bolus request + MSG_ID_TD_FLUID_BOLUS_RESPONSE = 0x60, ///< TD Fluid Bolus response MSG_ID_DD_BLOOD_LEAK_DATA = 0x61, ///< DD blood leak data MSG_ID_FP_INLET_PRESSURE_CHECK_DATA = 0x62, ///< FP Inlet Pressure Check broadcast data MSG_ID_UI_BLOOD_PRESSURE_REQUEST = 0x63, ///< UI request to initiate a blood pressure reading @@ -210,6 +210,10 @@ MSG_ID_TD_HEPARIN_PAUSE_RESUME_RESPONSE= 0xB2, ///< TD response to pause/resume Heparin delivery request MSG_ID_FFU_SIGNAL_TD_UPDATE_AVAILABLE = 0xB3, ///< FFU signal TD update is available. MSG_ID_FFU_SIGNAL_DD_UPDATE_AVAILABLE = 0xB4, ///< FFU signal DD update is available. + MSG_ID_DD_SUBSTITUTION_PUMP_DATA = 0xB5, ///< DD substitution pump broadcast data. + MSG_ID_DD_CONDUCTIVITY_SENSOR_RESISTANCE_DATA = 0xB6, ///< DD conductivity resistance data broadcast. + MSG_ID_UI_VITALS_ADJUSTMENT_REQUEST = 0xB8, ///< UI vitals adjustment request + MSG_ID_TD_VITALS_ADJUSTMENT_RESPONSE = 0xB9, ///< TD vitals adjustment response // service/test CAN messages MSG_ID_FIRST_TD_TESTER_MESSAGE = 0x8000, ///< First TD test message ID @@ -409,6 +413,11 @@ MSG_ID_DD_BICART_UPPER_PRESSURE_OVERRIDE_REQUEST = 0xA06A, ///< DD bicarb cartridge upper threshold pressure override MSG_ID_DD_BICART_LOWER_PRESSURE_OVERRIDE_REQUEST = 0xA06B, ///< DD bicarb cartridge lower threshold pressure override MSG_ID_DD_FLOATER_LEVEL_OVERRIDE_REQUEST = 0xA06C, ///< DD override request for D6 floater level override + MSG_ID_DD_SUBSTITUTION_PUMP_START_STOP_OVERRIDE_REQUEST = 0xA06D, ///< DD substitution pump start stop override request + MSG_ID_DD_SUBSTITUTION_PUMP_BROADCAST_INTERVAL_OVERRIDE_REQUEST = 0xA06E, ///< DD substitution pump broadcast override request + MSG_ID_DD_SUBSTITUTION_PUMP_TARGET_RATE_OVERRIDE_REQUEST = 0xA06F, ///< DD substitution pump target speed override request. + MSG_ID_DD_CONDUCTIVITY_SENSOR_CAL_REQUEST = 0xA070, ///< DD conductivity sensor cal request + MSG_ID_DD_CONDUCTIVITY_SENSOR_CAL_RESPONSE = 0xA071, ///< DD conductivity sensor cal response MSG_ID_FIRST_FP_TESTER_MESSAGE = 0xB000, ///< First FP test message ID MSG_ID_FP_TESTER_LOGIN_REQUEST = MSG_ID_FIRST_FP_TESTER_MESSAGE, ///< FP tester log-in @@ -488,6 +497,8 @@ MSG_ID_FP_BOOST_PUMP_INSTALL_STATUS_RESPONSE = 0xB04A, ///< FP response for boost pump installation status to Dialin MSG_ID_FP_CONDUCTIVITY_SENSOR_VERSION_REQUEST = 0xB04B, ///< FP conductivity sensor version request MSG_ID_FP_CONDUCTIVITY_SENSOR_VERSION_RESPONSE = 0xB04C, ///< FP conductivity sensor version response + MSG_ID_FP_CONDUCTIVITY_SENSOR_CAL_REQUEST = 0xB04D, ///< FP conductivity sensor cal request + MSG_ID_FP_CONDUCTIVITY_SENSOR_CAL_RESPONSE = 0xB04E, ///< FP conductivity sensor cal response MSG_ID_TD_DEBUG_EVENT = 0xFFF1, ///< TD debug event text to be logged in event log @@ -519,11 +530,11 @@ REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_MINIMUM = 13, ///< Treatment time change is less than minimum treatment time REQUEST_REJECT_REASON_UF_NOT_IN_PROGESS = 14, ///< Ultrafiltration is not currently in progress REQUEST_REJECT_REASON_UF_NOT_PAUSED = 15, ///< Ultrafiltration is not currently paused - REQUEST_REJECT_REASON_SALINE_BOLUS_IN_PROGRESS = 16, ///< A saline bolus is in progress + REQUEST_REJECT_REASON_FLUID_BOLUS_IN_PROGRESS = 16, ///< A fluid bolus is in progress REQUEST_REJECT_REASON_PARAM_OUT_OF_RANGE = 17, ///< A treatment parameter is out of range REQUEST_REJECT_REASON_FILTER_FLUSH_HAS_BEEN_EXPIRED = 18, ///< Filter flush time has been expired REQUEST_REJECT_REASON_SALINE_MAX_VOLUME_REACHED = 19, ///< Saline bolus volume maximum has been reached - no more saline allowed - REQUEST_REJECT_REASON_SALINE_BOLUS_NOT_IN_PROGRESS = 20, ///< A saline bolus is not in progress + REQUEST_REJECT_REASON_FLUID_BOLUS_NOT_IN_PROGRESS = 20, ///< A fluid bolus is not in progress REQUEST_REJECT_REASON_ACTION_DISABLED_IN_CURRENT_STATE = 21, ///< Requested user action is disabled in current state REQUEST_REJECT_REASON_ALARM_IS_ACTIVE = 22, ///< Requested user action not allowed while alarm is active REQUEST_REJECT_REASON_INVALID_COMMAND = 23, ///< Requested user action invalid @@ -546,7 +557,7 @@ REQUEST_REJECT_REASON_TD_SERVICE_IS_DUE = 40, ///< TD service is due REQUEST_REJECT_REASON_RO_FILTER_TEMPERATURE_OUT_OF_RANGE = 41, ///< RO filter temperature out of range REQUEST_REJECT_REASON_DD_INCOMPATIBLE = 42, ///< DD firmware version is not compatible with TD firmware - REQUEST_REJECT_REASON_DIALYZER_REPRIME_IN_PROGRESS = 43, ///< Saline bolus is not allowed during dialyzer reprime + REQUEST_REJECT_REASON_DIALYZER_REPRIME_IN_PROGRESS = 43, ///< Fluid bolus is not allowed during dialyzer reprime REQUEST_REJECT_REASON_RO_ONLY_MODE_DD_BUSY = 44, ///< RO only mode DD is busy REQUEST_REJECT_REASON_RO_ONLY_MODE_INVALID_PARAMETER = 45, ///< RO only mode invalid parameter REQUEST_REJECT_REASON_RO_ONLY_MODE_INVALID_PAYLOAD_LENGTH = 46, ///< RO only mode invalid payload length @@ -563,6 +574,7 @@ REQUEST_REJECT_REASON_TD_AUTHENTICATION_INVALID = 57, ///< TD authentication invalid REQUEST_REJECT_REASON_CONFIRMATION_NOT_EXPECTED = 58, ///< Confirmation received without prior validation REQUEST_REJECT_REASON_CONFIRMATION_MISMATCH = 59, ///< Confirmed value does not match validated value + REQUEST_REJECT_REASON_INVALID_TREATMENT_SUB_STATE = 60, ///< Request is not allowed in current treatment sub-state NUM_OF_REQUEST_REJECT_REASONS ///< Number of settings change reject codes }; typedef enum Request_Reject_Reasons REQUEST_REJECT_REASON_CODE_T; ///< Type for settings change rejection reason codes enumeration