Index: MsgDefs.h =================================================================== diff -u -rc307972e2a605d62e355847007e0db0c9876cf52 -rbf926947342bad2327352d878c681401a6b2d994 --- MsgDefs.h (.../MsgDefs.h) (revision c307972e2a605d62e355847007e0db0c9876cf52) +++ MsgDefs.h (.../MsgDefs.h) (revision bf926947342bad2327352d878c681401a6b2d994) @@ -9,7 +9,7 @@ * @file MsgDefs.h * * @author (last) Raghu Kallala -* @date (last) 22-Apr-2026 +* @date (last) 29-Apr-2026 * * @author (original) Sean Nash * @date (original) 01-Aug-2024 @@ -92,12 +92,12 @@ MSG_ID_TD_TREATMENT_STATE_DATA = 0x3C, ///< TD treatment state data broadcast MSG_ID_TD_SALINE_BOLUS_DATA = 0x3D, ///< TD saline bolus status data broadcast MSG_ID_TD_ULTRAFILTRATION_DATA = 0x3E, ///< TD ultrafiltration status data broadcast - MSG_ID_UI_TREATMENT_PARAMS_TO_VALIDATE = 0x3F, ///< UI treatment parameters (except UF volume) to be validated by TD + MSG_ID_UI_TREATMENT_PARAMS_TO_VALIDATE = 0x3F, ///< UI treatment parameters to be validated by TD MSG_ID_TD_RESP_TREATMENT_PARAMS_TO_VALIDATE = 0x40, ///< TD response to treatment parameter validation request - MSG_ID_UI_ULTRAFILTRATION_VOLUME_TO_VALIDATE = 0x41, ///< UI ultrafiltration volume parameter to be validated by TD - MSG_ID_TD_RESP_ULTRAFILTRATION_VOLUME_TO_VALIDATE = 0x42, ///< TD response to ultrafiltration volume validation request + MSG_ID_AVAILABLE_2 = 0x41, ///< Available message ID 2 + MSG_ID_AVAILABLE_4 = 0x42, ///< Available message ID 3 MSG_ID_TD_TREATMENT_PARAM_RANGES = 0x43, ///< TD treatment parameter ranges for UI - MSG_ID_UI_TREATMENT_PARAMS_CONFIRMED = 0x44, ///< UI treatment parameters confirmed/rejected + MSG_ID_TD_VALIDATED_TREATMENT_PARAMS = 0x44, ///< Treatment parameters validated and confirmed from TD MSG_ID_UI_INITIATE_TREATMENT_WORKFLOW = 0x45, ///< UI initiate/cancel treatment workflow request MSG_ID_TD_RESP_INITIATE_TREATMENT_WORKFLOW = 0x46, ///< TD response to initiate/cancel treatment workflow request MSG_ID_UI_UF_PAUSE_RESUME_REQUEST = 0x47, ///< UI ultrafiltration pause/resume request @@ -380,7 +380,6 @@ MSG_ID_DD_DIALYSATE_DELTA_CONDUCTIVITY_OVERRIDE_REQUEST = 0xA069, ///< DD Dialysate delta target conductivity override MSG_ID_DD_BICART_UPPER_PRESSURE_OVERRIDE_REQUEST = 0xA06A, ///< DD bicarb cartridge upper threshold pressure override MSG_ID_DD_BICART_LOWER_PRESSURE_OVERRIDE_REQUEST = 0xA06B, ///< DD bicarb cartridge lower threshold pressure override - MSG_ID_DD_FLOATER_LEVEL_OVERRIDE_REQUEST = 0xA06C, ///< DD D6 floater level override MSG_ID_FIRST_FP_TESTER_MESSAGE = 0xB000, ///< First FP test message ID MSG_ID_FP_TESTER_LOGIN_REQUEST = MSG_ID_FIRST_FP_TESTER_MESSAGE, ///< FP tester log-in @@ -399,7 +398,7 @@ MSG_ID_FP_PRESSURE_SENSOR_FILTER_TEMPERATURE_OVERRIDE_REQUEST = 0xB00D, ///< FP pressure sensor filter temperature override request MSG_ID_FP_PRESSURE_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB00E, ///< FP pressures data publish interval override request MSG_ID_FP_LEVEL_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB00F, ///< FP level data publish interval override request - MSG_ID_FP_FLOATER_LEVEL_OVERRIDE_REQUEST = 0xB010, ///< FP override request for P25 floater level sensor. + MSG_ID_FP_LEVEL_OVERRIDE_REQUEST = 0xB010, ///< FP override request for level sensor. MSG_ID_FP_FLOWS_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB011, ///< FP flows data publish interval override request MSG_ID_FP_FLOW_RATE_OVERRIDE_REQUEST = 0xB012, ///< FP override request for flow rate (mL/min) MSG_ID_FP_FLOW_TEMP_OVERRIDE_REQUEST = 0xB013, ///< FP override request for flow temperature (deg C) @@ -528,6 +527,10 @@ REQUEST_REJECT_REASON_HEPARIN_PAUSE_INVALID_IN_THIS_STATE = 50, ///< Heparin cannot be paused if not currently deliverying Heparin REQUEST_REJECT_REASON_HEPARIN_NOT_PAUSED = 51, ///< Heparin cannot be resumed if not paused REQUEST_REJECT_REASON_HEPARIN_VOLUME_EXCEEDS_10_ML = 52, ///< Heparin volume needed for treatment exceeds 10 mL maximum. + REQUEST_REJECT_REASON_PARAM_NOT_APPLICABLE = 53, ///< Treatment parameter not applicable for current treatment modality type + REQUEST_REJECT_REASON_ACID_CONV_FACTOR_MISMATCH = 54, ///< Acid conversion factor from UI mismatch with FW + REQUEST_REJECT_REASON_INVALID_PATIENT_WEIGHTS = 55, ///< Patient pre and estimated target weights are invalid + REQUEST_REJECT_REASON_UF_VOL_AND_WEIGHTS_INCONSISTENT = 56, ///< UF volume and the patient weights are not consistent NUM_OF_REQUEST_REJECT_REASONS ///< Number of settings change reject codes }; typedef enum Request_Reject_Reasons REQUEST_REJECT_REASON_CODE_T; ///< Type for settings change rejection reason codes enumeration