Index: AlarmDefs.h =================================================================== diff -u -ra01144534759117e70ca8300e49954cd149b4b6a -r0044478a3aaef1d9436b1f82ae73f4064a298b78 --- AlarmDefs.h (.../AlarmDefs.h) (revision a01144534759117e70ca8300e49954cd149b4b6a) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 0044478a3aaef1d9436b1f82ae73f4064a298b78) @@ -100,6 +100,12 @@ ALARM_ID_DD_SPENT_DIALYSATE_PUMP_DIRECTION_FPGA_FAULT = 69, ///< DD spent dialysate pump direction error count FPGA fault ALARM_ID_DD_FLUID_TOO_LOW_WHILE_PRIMARY_HEATER_IS_ON = 70, ///< DD primary heater is On when no fluid is present ALARM_ID_DD_FLUID_TOO_LOW_WHILE_TRIMMER_HEATER_IS_ON = 71, ///< DD trimmer heater is On when no fluid is present + ALARM_ID_DD_WATER_INLET_INPUT_PRES_TIMEOUT_FAULT = 72, ///< DD water inlet input pressure sensor freshness/error timeout fault + ALARM_ID_DD_WATER_INLET_OUTPUT_PRES_TIMEOUT_FAULT = 73, ///< DD water inlet output pressure sensor freshness/error timeout fault + ALARM_ID_DD_INLET_WATER_PRESSURE_IN_LOW_RANGE = 74, ///< DD inlet water pressure input low range + ALARM_ID_DD_INLET_WATER_PRESSURE_IN_HIGH_RANGE = 75, ///< DD inlet water pressure input high range + ALARM_ID_DD_INLET_WATER_PRESSURE_OUT_LOW_RANGE = 76, ///< DD inlet water pressure output low range + ALARM_ID_DD_INLET_WATER_PRESSURE_OUT_HIGH_RANGE = 77, ///< DD inlet water pressure output high range NUM_OF_ALARM_IDS ///< Number of alarms }; @@ -307,7 +313,13 @@ { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DD_SPENT_DIALYSATE_PUMP_DIRECTION_FPGA_FAULT }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DD_FLUID_TOO_LOW_WHILE_PRIMARY_HEATER_IS_ON }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DD_FLUID_TOO_LOW_WHILE_TRIMMER_HEATER_IS_ON }, - + { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DD_WATER_INLET_INPUT_PRES_TIMEOUT_FAULT }, + { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DD_WATER_INLET_OUTPUT_PRES_TIMEOUT_FAULT }, + { ALARM_PRIORITY_MEDIUM, 431, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , ALARM_ID_DD_INLET_WATER_PRESSURE_IN_LOW_RANGE }, + { ALARM_PRIORITY_MEDIUM, 430, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , ALARM_ID_DD_INLET_WATER_PRESSURE_IN_HIGH_RANGE }, + // Priority Rank Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr ClrOnly TxLog ID + { ALARM_PRIORITY_MEDIUM, 431, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , ALARM_ID_DD_INLET_WATER_PRESSURE_OUT_LOW_RANGE }, + { ALARM_PRIORITY_MEDIUM, 430, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , ALARM_ID_DD_INLET_WATER_PRESSURE_OUT_HIGH_RANGE }, }; // Priority Rank Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr ClrOnly TxLog ID /// Table of alarms and their rank. @@ -371,6 +383,8 @@ { 110, ALARM_ID_DD_SPENT_DIALYSATE_PUMP_DIRECTION_FPGA_FAULT }, { 110, ALARM_ID_DD_FLUID_TOO_LOW_WHILE_PRIMARY_HEATER_IS_ON }, { 110, ALARM_ID_DD_FLUID_TOO_LOW_WHILE_TRIMMER_HEATER_IS_ON }, + { 110, ALARM_ID_DD_WATER_INLET_INPUT_PRES_TIMEOUT_FAULT }, + { 110, ALARM_ID_DD_WATER_INLET_OUTPUT_PRES_TIMEOUT_FAULT }, { 111, ALARM_ID_TD_DD_COMM_TIMEOUT }, { 111, ALARM_ID_TD_CAN_MESSAGE_NOT_ACKED_BY_DD }, { 111, ALARM_ID_DD_CAN_MESSAGE_NOT_ACKED_BY_RO }, @@ -380,6 +394,10 @@ { 202, ALARM_ID_TD_ARTERIAL_PRESSURE_LOW }, { 203, ALARM_ID_TD_ARTERIAL_PRESSURE_HIGH }, { 210, ALARM_ID_TD_CARTRIDGE_DOOR_OPENED }, + { 430, ALARM_ID_DD_INLET_WATER_PRESSURE_IN_HIGH_RANGE }, + { 431, ALARM_ID_DD_INLET_WATER_PRESSURE_IN_LOW_RANGE }, + { 430, ALARM_ID_DD_INLET_WATER_PRESSURE_OUT_HIGH_RANGE }, + { 431, ALARM_ID_DD_INLET_WATER_PRESSURE_OUT_LOW_RANGE }, { 700, ALARM_ID_TD_ARTERIAL_PRESSURE_SELF_TEST_FAILURE }, { 700, ALARM_ID_TD_VENOUS_PRESSURE_SELF_TEST_FAILURE }, { 710, ALARM_ID_TD_PRE_TREATMENT_DRY_PRESSURE_TEST_FAILURE }, @@ -436,18 +454,18 @@ // Num Alarm ID Device Display Title Instructions Alarm List Title Description Trigger Condition { 26 , ALARM_ID_TD_ARTERIAL_SENSOR_TIMEOUT_FAULT , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Arterial Pressure Sensor Error | TD arterial pressure sensor reporting error or not being read successfully | Arterial pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, { 27 , ALARM_ID_TD_VENOUS_SENSOR_TIMEOUT_FAULT , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Venous Pressure Sensor Error | TD venous pressure sensor reporting error or not being read successfully | Venous pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, - { 28 , ALARM_ID_DD_HYD_OUTLET_PRES_TIMEOUT_FAULT , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Hyd outlet Pressure Sensor Error | DD hydraulics outlet pressure sensor reporting error or not being read successfully | Hydraulics outlet pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, - { 29 , ALARM_ID_DD_BIBAG_PRES_TIMEOUT_FAULT , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Bibag Pressure Sensor Error | DD bibag pressure sensor reporting error or not being read successfully | Bibag pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, - { 30 , ALARM_ID_DD_SPENT_DIALYSATE_PRES_TIMEOUT_FAULT , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Spent Dial Pressure Sensor Error | DD spent dialysate pressure sensor reporting error or not being read successfully | Spent dialysate pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, - { 31 , ALARM_ID_DD_FRESH_DIALYSATE_PRES_TIMEOUT_FAULT , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fresh Dial Pressure Sensor Error | DD fresh dialysate pressure sensor reporting error or not being read successfully | Fresh dialysate pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, - { 32 , ALARM_ID_DD_TRANSMEMB_PRES_TIMEOUT_FAULT , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Transmemb Pressure Sensor Error | DD transmembrane sensor reporting error or not being read successfully | Transmembrane pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, + { 28 , ALARM_ID_DD_HYD_OUTLET_PRES_TIMEOUT_FAULT , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Hyd outlet Pressure Sensor Error | DD hydraulics outlet pressure sensor reporting error or not being read successfully | Hydraulics outlet pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, + { 29 , ALARM_ID_DD_BIBAG_PRES_TIMEOUT_FAULT , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Bibag Pressure Sensor Error | DD bibag pressure sensor reporting error or not being read successfully | Bibag pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, + { 30 , ALARM_ID_DD_SPENT_DIALYSATE_PRES_TIMEOUT_FAULT , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Spent Dial Pressure Sensor Error | DD spent dialysate pressure sensor reporting error or not being read successfully | Spent dialysate pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, + { 31 , ALARM_ID_DD_FRESH_DIALYSATE_PRES_TIMEOUT_FAULT , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fresh Dial Pressure Sensor Error | DD fresh dialysate pressure sensor reporting error or not being read successfully | Fresh dialysate pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, + { 32 , ALARM_ID_DD_TRANSMEMB_PRES_TIMEOUT_FAULT , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Transmemb Pressure Sensor Error | DD transmembrane sensor reporting error or not being read successfully | Transmembrane pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, { 33 , ALARM_ID_TD_VOLTAGE_OUT_OF_RANGE , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Voltage Monitor | TD monitored voltage is out of range | If the TD monitored voltages are out of range for a certain period of time. | "}, { 34 , ALARM_ID_TD_AC_POWER_LOST , "TD | Power Loss | AC Power has been lost.\n- Check all electrical connections.\n- Press Resume/OK to return to welcome screen. | Loss of AC Power | TD AC power lost alarm | The TD Software shall trigger an alarm if an AC power loss is detected while the TD system is in standby, service, or treatment parameters mode. | "}, { 35 , ALARM_ID_TD_AC_POWER_LOST_IN_TREATMENT , "TD | Power Loss | Treatment must be terminated due to a power loss.\n- Follow clinic instructions on when to initiate manual rinseback.\n- Check all electrical connections.\n- If power returns within 5 minutes of outage, \n- rinseback will be allowed. | Blood Stop: Loss of AC Power | TD AC power lost alarm | The TD Software shall trigger an alarm if an AC power loss is detected while the TD system is in pre-treatment, treatment, or post-treatment mode. | "}, - { 36 , ALARM_ID_DD_CD1_SENSOR_FPGA_FAULT , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Conductivity Sensor (CD1) Error | DD conductivity sensor located before balancing chamber reporting error or not being read successfully | Conductvity Sensor (CD1) is reporting an error or FPGA is failing to read sensor. | "}, - { 37 , ALARM_ID_DD_CD2_SENSOR_FPGA_FAULT , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Conductivity Sensor (CD2) Error | DD conductivity sensor located after balancing chamber reporting error or not being read successfully | Conductvity Sensor (CD2) is reporting an error or FPGA is failing to read sensor. | "}, - { 38 , ALARM_ID_DD_CD3_SENSOR_FPGA_FAULT , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Conductivity Sensor (CD3) Error | DD conductivity sensor located after balancing chamber reporting error or not being read successfully | Conductvity Sensor (CD3) is reporting an error or FPGA is failing to read sensor. | "}, - { 39 , ALARM_ID_DD_CD4_SENSOR_FPGA_FAULT , "DD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Conductivity Sensor (CD4) Error | DD conductivity sensor located in spent dialysate path reporting error or not being read successfully | Conductvity Sensor (CD4) is reporting an error or FPGA is failing to read sensor. | "}, + { 36 , ALARM_ID_DD_CD1_SENSOR_FPGA_FAULT , "DD | Service Required: Dialysate Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Conductivity Sensor (CD1) Error | DD conductivity sensor located before balancing chamber reporting error or not being read successfully | Conductvity Sensor (CD1) is reporting an error or FPGA is failing to read sensor. | "}, + { 37 , ALARM_ID_DD_CD2_SENSOR_FPGA_FAULT , "DD | Service Required: Dialysate Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Conductivity Sensor (CD2) Error | DD conductivity sensor located after balancing chamber reporting error or not being read successfully | Conductvity Sensor (CD2) is reporting an error or FPGA is failing to read sensor. | "}, + { 38 , ALARM_ID_DD_CD3_SENSOR_FPGA_FAULT , "DD | Service Required: Dialysate Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Conductivity Sensor (CD3) Error | DD conductivity sensor located after balancing chamber reporting error or not being read successfully | Conductvity Sensor (CD3) is reporting an error or FPGA is failing to read sensor. | "}, + { 39 , ALARM_ID_DD_CD4_SENSOR_FPGA_FAULT , "DD | Service Required: Dialysate Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Conductivity Sensor (CD4) Error | DD conductivity sensor located in spent dialysate path reporting error or not being read successfully | Conductvity Sensor (CD4) is reporting an error or FPGA is failing to read sensor. | "}, { 40 , ALARM_ID_TD_VENOUS_BUBBLE_DETECTED , "TD | Venous Air Detected | Air detected in the venous air trap.\n- Confirm arterial access placement and confirm\nconnections are secure.\n- Treatment must be terminated without rinseback. | Blood Stop: Venous Air Bubble | TD venous air bubble detected alarm | If bubbles are detected during the treatment. | "}, { 41 , ALARM_ID_TD_CARTRIDGE_DOOR_OPENED , "TD | Blood Pump Stopped: Door Open | The device door is open.\n Close the device door. \n- Press Resume/OK to continue. | Blood Stop: Door Open | TD cartridge door opened alarm | If the cartridge door is opened as reported by the FPGA. | "}, { 42 , ALARM_ID_TD_STUCK_BUTTON_TEST_FAILED , "TD | Stuck Button | A button was pressed during start up and appears stuck. \n- Press and release the power and stop buttons on the\nfront of the device.\n- Turn device off, then back on.\n- If problem continues, call service to schedule a repair. | TD POST: Stuck Button | TD Stuck button POST failure. Stop or Off button detected to be pressed for at least 1 second during test shortly after power up | Stop or Off button are pressed for more than 1 sec during POST. | "}, @@ -481,6 +499,13 @@ { 69 , ALARM_ID_DD_SPENT_DIALYSATE_PUMP_DIRECTION_FPGA_FAULT , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: Spent Dial pump Dir Err Cnt | DD spent dialysate pump direction FPGA fault | If the FPGA indicates an direction error for a certain period of time. | "}, { 70 , ALARM_ID_DD_FLUID_TOO_LOW_WHILE_PRIMARY_HEATER_IS_ON , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: HP1 On With No Fluid | DD primary heater is On with low fluid level | If the Hydraulics floater sensing low level fluid for a certain period of time. | "}, { 71 , ALARM_ID_DD_FLUID_TOO_LOW_WHILE_TRIMMER_HEATER_IS_ON , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: HEQ On With No Fluid | DD trimmer heater is On with low fluid level | If the Balance air separation chamber fluid level is low for a certain period of time. | "}, + { 72 , ALARM_ID_DD_WATER_INLET_INPUT_PRES_TIMEOUT_FAULT , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Water Inlet Input Press Sensor Error | DD water inlet input pressure sensor reporting error or not being read successfully | Water Inlet Input pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, + { 73 , ALARM_ID_DD_WATER_INLET_OUTPUT_PRES_TIMEOUT_FAULT , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Water Inlet Output Press Sensor Error | DD water inlet output pressure sensor reporting error or not being read successfully | Water Inlet Output pressure sensor is reporting an error or FPGA is failing to read sensor. | "}, + { 74 , ALARM_ID_DD_INLET_WATER_PRESSURE_IN_LOW_RANGE , "DD | Incoming Water Pressure Input Low | Water pressure of incoming water is low.\n- Treatment is currently paused.\n- Check the incoming water supply.\n- When the pressure is within target range\nResume/OK button will be available.\n- Press Resume/OK to continue treatment. | DD: Inlet Water Pres Input Low | DD Inlet water pressure input too low | Inlet water pressure input < 25 PSI. | "}, + { 75 , ALARM_ID_DD_INLET_WATER_PRESSURE_IN_HIGH_RANGE , "DD | Incoming Water Pressure Input High | Incoming water pressure is high.\n- Treatment is currently paused.\n- Check the incoming water supply.\n- When the pressure is within target range\nResume/OK button will be available.\n- Press Resume/OK to continue treatment. | DD: Inlet Water Pres Input High | DD inlet water pressure input is too high | If the inlet water pressure input is > 80 psig. | "}, + // Num Alarm ID Device Display Title Instructions Alarm List Title Description Trigger Condition + { 76 , ALARM_ID_DD_INLET_WATER_PRESSURE_OUT_LOW_RANGE , "DD | Incoming Water Pressure Output Low | Water inlet pressure after regulator is low.\n- Treatment is currently paused.\n- Check the incoming water supply.\n- When the pressure is within target range\nResume/OK button will be available.\n- Press Resume/OK to continue treatment. | DD: Inlet Water Pres Output Low | DD Inlet water pressure output too low | Inlet water pressure output < 11 PSI. | "}, + { 77 , ALARM_ID_DD_INLET_WATER_PRESSURE_OUT_HIGH_RANGE , "DD | Incoming Water Pressure Output High | Water inlet pressure after regulator is high.\n- Treatment is currently paused.\n- Check the incoming water supply.\n- When the pressure is within target range\nResume/OK button will be available.\n- Press Resume/OK to continue treatment. | DD: Inlet Water Pres Output High | DD inlet water pressure output is too high | If the inlet water pressure output is > 20 psig. | "}, }; #endif // manual alarms