Index: AlarmDefs.h =================================================================== diff -u -r23c6a623afe7b16729d3ebe15e492b7332381bcd -r7b69a2e66b8ee816577cdcbbde94714844805b24 --- AlarmDefs.h (.../AlarmDefs.h) (revision 23c6a623afe7b16729d3ebe15e492b7332381bcd) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 7b69a2e66b8ee816577cdcbbde94714844805b24) @@ -230,6 +230,7 @@ ALARM_ID_TD_PRIME_COMPLETED_MEDIUM = 198, ///< TD prime completed medium priority alarm ALARM_ID_TD_REPEATED_AIR_TRAP_LOWER_EVENTS = 199, ///< TD repeated air trap lower events ALARM_ID_TD_TUBE_SET_MISMATCH = 200, ///< TD tubeset mismatch alarm + ALARM_ID_TD_PRE_TX_HEPARIN_LOAD_SYRINGE = 201, ///< TD Pre-Treatment Load Heparin Syringe NUM_OF_ALARM_IDS ///< Number of alarms }; typedef enum Alarm_List ALARM_ID_T; ///< Type for alarm list enumeration @@ -322,7 +323,6 @@ /**@}*/ - #if defined (__ALARM_MGMT_C__) || defined(__ALARM_MGMT_DD_C__) || defined(__ALARM_MGMT_TD_C__) || defined(__ALARM_MGMT_FP_C__) /** @@ -380,7 +380,6 @@ }; typedef struct AlarmTableResponsePayload ALARM_PROP_T; - /// Record defining the ranking of each individual alarm. struct AlarmsRankRecord { @@ -605,6 +604,7 @@ { ALARM_PRIORITY_MEDIUM, 590, ALM_SRC_TD, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, ALARM_ID_TD_PRIME_COMPLETED_MEDIUM }, { ALARM_PRIORITY_HIGH, 17, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , ALARM_ID_TD_REPEATED_AIR_TRAP_LOWER_EVENTS }, { ALARM_PRIORITY_MEDIUM, 300, ALM_SRC_TD, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_TUBE_SET_MISMATCH }, + { ALARM_PRIORITY_LOW, 717, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, ALARM_ID_TD_PRE_TX_HEPARIN_LOAD_SYRINGE }, }; // Priority Rank Source Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr AutoRes ClrOnly TxLog ID /// Table of alarms and their rank. @@ -789,6 +789,7 @@ { 711, ALARM_ID_TD_VENOUS_BUBBLE_SELF_TEST_FAILURE }, { 715, ALARM_ID_TD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM }, { 716, ALARM_ID_TD_SYRINGE_PUMP_OCCLUSION }, + { 717, ALARM_ID_TD_PRE_TX_HEPARIN_LOAD_SYRINGE }, { 730, ALARM_ID_TD_SYRINGE_PUMP_SYRINGE_EMPTY }, { 745, ALARM_ID_TD_SYRINGE_DETECTED }, { 850, ALARM_ID_BATTERY_LOW }, @@ -1041,6 +1042,7 @@ { 198 , ALARM_ID_TD_PRIME_COMPLETED_MEDIUM , "TD | Prime Complete - 30 MIN WARNING | The priming process completed 90 minutes ago. \n- Treatment must begin within 30 minutes or the\npre-treatment process will be terminated.\n- Press Resume/OK to continue. | Process: Pre-Tx Prime Complete | TD prime completed medium priority alarm | In Pre-Treatment Recirculation for 90 minutes | "}, { 199 , ALARM_ID_TD_REPEATED_AIR_TRAP_LOWER_EVENTS , "TD | Blood Pump Stopped: Venous Air Detector | The air trap level required repeated lowering events. \n- Confirm blood tubing connections are secure.\n- Inspect the air trap for abnormal fluid levels. \n- Resume treatment if the condition has been corrected. | Blood Stop: Repeated Air Trap Lower | Repeated air trap lower events detected during treatment | If 5 air trap lower events occur within 5 minutes during treatment. | "}, { 200 , ALARM_ID_TD_TUBE_SET_MISMATCH , "TD | Wrong Tube Set Installed | The installed tube set does not match the selected treatment type. \n- Remove the current tube set.\n- Install the correct tube set for the selected treatment:\n HD or HD with Online Fluid requires an HD tube set.\n HDF requires an HDF tube set. | TD Tube Set Mismatch | TD installed tube set type does not match the selected treatment modality | If the scanned tube set type does not match the tube set type required for the selected treatment modality. | "}, + { 201 , ALARM_ID_TD_PRE_TX_HEPARIN_LOAD_SYRINGE , "UI TD | Load Syringe | Fill syringe with 4mL of heparin.\n- Connect heparin filled syringe to infusion port.\n- Insert syringe into the syringe pump.\n- Lock heparin syringe in place.\n- Unclamp heparin pinch clamp. | Process: Pre-Tx Load Syringe | User must load the heparin syringe before continuing heparin setup. | While in Pre-Treatment: Heparin Setup: Await Syringe Load Confirmation state. | "}, }; #endif // manual alarms