Index: AlarmDefs.h =================================================================== diff -u -re3a8adf77f70c9915c54c29a60b47c16c4d57d21 -r894b0752f604b2535228ec0efd45e2c45bcff2fc --- AlarmDefs.h (.../AlarmDefs.h) (revision e3a8adf77f70c9915c54c29a60b47c16c4d57d21) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 894b0752f604b2535228ec0efd45e2c45bcff2fc) @@ -216,7 +216,7 @@ ALARM_ID_TD_SYRINGE_PUMP_PRIME_TIMEOUT = 184, ///< TD syringe pump prime timeout ALARM_ID_FP_P9_COND_SENSOR_FPGA_FAULT = 185, ///< FP P9 conductivity sensor fpga fault ALARM_ID_FP_P18_COND_SENSOR_FPGA_FAULT = 186, ///< FP P18 conductivity sensor fpga fault - ALARM_ID_TD_INVALID_TUBING_SET = 187, ///< TD invalid tube set + ALARM_ID_TD_INVALID_TUBE_SET = 187, ///< TD invalid tube set ALARM_ID_TD_INSTALL_NEW_BLOOD_TUBING_SET = 188, ///< TD install new blood tubing set ALARM_ID_TD_TUBE_SET_NOT_DETECTED = 189, ///< TD no tubing set detected ALARM_ID_TD_TUBE_SET_AUTHENTICATION_TIMEOUT = 190, ///< TD tubing set authentication timeout @@ -421,7 +421,7 @@ { ALARM_PRIORITY_HIGH, 201, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , ALARM_ID_TD_VENOUS_PRESSURE_HIGH }, { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_VENOUS_PRESSURE_OUT_OF_RANGE }, { ALARM_PRIORITY_LOW, 700, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_VENOUS_PRESSURE_SELF_TEST_FAILURE }, - { ALARM_PRIORITY_LOW, 717, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_INVALID_TUBING_SET }, + { ALARM_PRIORITY_LOW, 717, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_INVALID_TUBE_SET }, { ALARM_PRIORITY_LOW, 718, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_INSTALL_NEW_BLOOD_TUBING_SET }, { ALARM_PRIORITY_LOW, 719, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_TUBE_SET_NOT_DETECTED }, { ALARM_PRIORITY_LOW, 720, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_TUBE_SET_AUTHENTICATION_TIMEOUT }, @@ -748,7 +748,7 @@ { 711, ALARM_ID_TD_VENOUS_BUBBLE_SELF_TEST_FAILURE }, { 715, ALARM_ID_TD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM }, { 716, ALARM_ID_TD_SYRINGE_PUMP_OCCLUSION }, - { 717, ALARM_ID_TD_INVALID_TUBING_SET }, + { 717, ALARM_ID_TD_INVALID_TUBE_SET }, { 718, ALARM_ID_TD_INSTALL_NEW_BLOOD_TUBING_SET }, { 719, ALARM_ID_TD_TUBE_SET_NOT_DETECTED }, { 720, ALARM_ID_TD_TUBE_SET_AUTHENTICATION_TIMEOUT }, @@ -997,7 +997,7 @@ { 184 , ALARM_ID_TD_SYRINGE_PUMP_PRIME_TIMEOUT , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Pre- Tx Hep. Pump Timeout. | TD syringe pump timeout alarm | If the syringe pump priming > 5 seconds | "}, { 185 , ALARM_ID_FP_P9_COND_SENSOR_FPGA_FAULT , "FP | Service Required: FP Device | A problem was detected with the FP device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Conductivity Sensor Error | FP conductivity sensor (P9) located in inlet water path reporting error or not being read successfully | Conductvity Sensor (P9) is reporting an error or FPGA is failing to read sensor. | "}, { 186 , ALARM_ID_FP_P18_COND_SENSOR_FPGA_FAULT , "FP | Service Required: FP Device | A problem was detected with the FP device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Conductivity Sensor Error | FP conductivity sensor (P18) located in inlet water path reporting error or not being read successfully | Conductvity Sensor (P18) is reporting an error or FPGA is failing to read sensor. | "}, - { 187 , ALARM_ID_TD_INVALID_TUBING_SET , "TD | Invalid Blood Tubing Set | A problem has been detected during self-test.\n- The installed blood tubing set is not valid.\n- Install a valid blood tubing set intended for the selected treatment modality. | Process: Pre-Tx Dry Self-Test | TD detected invalid tubing set during authentication | If authentication response indicates the tubing set is invalid. | "}, + { 187 , ALARM_ID_TD_INVALID_TUBE_SET , "TD | Invalid Blood Tubing Set | A problem has been detected during self-test.\n- The installed blood tubing set is not valid.\n- Install a valid blood tubing set intended for the selected treatment modality. | Process: Pre-Tx Dry Self-Test | TD detected invalid tubing set during authentication | If authentication response indicates the tubing set is invalid. | "}, { 188 , ALARM_ID_TD_INSTALL_NEW_BLOOD_TUBING_SET , "TD | Install New Blood Tubing Set | A problem has been detected during self-test.\n- Fluid detected in the tubing set or no valid tubing set installed.\n- Install a new, unused blood tubing set and ensure proper installation. | Process: Pre-Tx Dry Self-Test | TD detected used, wet, or missing blood tubing set | If bubble is detected, air trap levels indicate fluid, or barcode scan fails. | "}, { 189 , ALARM_ID_TD_TUBE_SET_NOT_DETECTED , "TD | No Blood Tubing Set Detected | A problem has been detected during self-test.\n- No blood tubing set detected in the system.\n- Install a blood tubing set and ensure proper placement. | Process: Pre-Tx Dry Self-Test | TD did not detect tubing set during verification | If no tubing set is detected during tube set loaded check. | "}, { 190 , ALARM_ID_TD_TUBE_SET_AUTHENTICATION_TIMEOUT , "TD | Tubing Set Authentication Timeout | A problem has been detected during self-test.\n- Authentication response not received.\n- Retry or check system communication. | Process: Pre-Tx Dry Self-Test | TD did not receive authentication response from UI | If no authentication response is received within timeout period. | "}, Index: MsgDefs.h =================================================================== diff -u -re1145259ea5ba3c2ca7f1bf80d3b8ad3223f5cb1 -r894b0752f604b2535228ec0efd45e2c45bcff2fc --- MsgDefs.h (.../MsgDefs.h) (revision e1145259ea5ba3c2ca7f1bf80d3b8ad3223f5cb1) +++ MsgDefs.h (.../MsgDefs.h) (revision 894b0752f604b2535228ec0efd45e2c45bcff2fc) @@ -203,8 +203,8 @@ MSG_ID_UI_ADJUST_PATIENT_DISCONNECT_CONFIRM_REQUEST = 0xAB, ///< UI adjust patient disconnect confirm request MSG_ID_TD_ADJUST_PATIENT_DISCONNECT_CONFIRM_RESPONSE = 0xAC, ///< TD adjust patient disconnect confirm response MSG_ID_TD_DRY_SELF_TEST_PROGRESS_DATA = 0xAD, ///< TD dry self test progress data - MSG_ID_TD_TUBING_SET_BARCODE_SCAN_REQUEST = 0xAE, ///< TD tubing set barcode scan request - MSG_ID_UI_TUBE_SET_AUTHENTICATION_ACK_REQUEST = 0xAF, ///< UI tube set authentication acknowledge request + MSG_ID_TD_TUBING_SET_BARCODE_SCAN_REQUEST = 0xAE, ///< TD tube set authentication request + MSG_ID_TD_TUBE_SET_AUTHENTICATION_REQUEST = 0xAF, ///< UI tube set authentication acknowledge request MSG_ID_TD_TUBE_SET_AUTHENTICATION_ACK_RESPONSE = 0xB0, ///< TD tube set authentication acknowledge response // service/test CAN messages