Index: AlarmDefs.h =================================================================== diff -u -r57fc86514c26dc2a9d45f55696a19824385fadea -r8f4c7a14f0ed74c238c7c72a316a026e50dc3cec --- AlarmDefs.h (.../AlarmDefs.h) (revision 57fc86514c26dc2a9d45f55696a19824385fadea) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 8f4c7a14f0ed74c238c7c72a316a026e50dc3cec) @@ -7,8 +7,8 @@ * * @file AlarmDefs.h * -* @author (last) Varshini Nagabooshanam -* @date (last) 17-Mar-2026 +* @author (last) Michael Garthwaite +* @date (last) 08-Apr-2026 * * @author (original) Sean Nash * @date (original) 01-Aug-2024 @@ -195,10 +195,31 @@ ALARM_ID_FP_PERMEATE_FLOW_OUT_LOW_RANGE = 163, ///< FP permeate flow low fault ALARM_ID_FP_INLET_PRESSURE_LOW_RANGE = 164, ///< FP inlet pressure low fault ALARM_ID_TD_AIR_TRAP_LOWER_TIMEOUT = 165, ///< TD air trap lower timeout - ALARM_ID_TD_INVALID_TUBE_SET = 166, ///< TD invalid tube set - ALARM_ID_TD_INSTALL_NEW_BLOOD_TUBING_SET = 167, ///< TD install new blood tubing set - ALARM_ID_TD_INSTALL_NEW_CARTRIDGE = 168, ///< TD insta - ALARM_ID_TD_NO_CARTRIDGE_LOADED = 169, ///< TD no catridge loaded + ALARM_ID_TD_SYRINGE_PUMP_SELF_TEST_FAILURE = 166, ///< TD syringe pump self-test failure alarm + ALARM_ID_TD_SYRINGE_PUMP_RUNNING_WHILE_BP_OFF_ERROR = 167, ///< TD syringe pump is running while the BP is off + ALARM_ID_TD_SYRINGE_PUMP_FPGA_ADC_FAULT = 168, ///< TD syringe pump ADC FPGA fault + ALARM_ID_TD_SYRINGE_PUMP_FAULT = 169, ///< TD syringe pump fault reported by FPGA + ALARM_ID_TD_SYRINGE_PUMP_DAC_WRITE_ERROR = 170, ///< TD syringe pump DAC write failure + ALARM_ID_TD_SYRINGE_PUMP_SPEED_ERROR = 171, ///< TD syringe pump speed check error + ALARM_ID_TD_SYRINGE_PUMP_VOLUME_ERROR = 172, ///< TD syringe pump volume check error + ALARM_ID_TD_SYRINGE_PUMP_OVER_TRAVEL_ERROR = 173, ///< TD syringe pump over travel error + ALARM_ID_TD_SYRINGE_PUMP_NOT_STOPPED_ERROR = 174, ///< TD syringe pump not stopped in off state error + ALARM_ID_TD_SYRINGE_PUMP_ENCODER_DIRECTION_ERROR = 175, ///< TD syringe pump direction (from encoder) error + ALARM_ID_TD_SYRINGE_PUMP_CONTROLLER_DIRECTION_ERROR = 176, ///< TD syringe pump direction (from controller) error + ALARM_ID_TD_SYRINGE_PUMP_SYRINGE_EMPTY = 177, ///< TD syringe empty alarm + ALARM_ID_TD_SYRINGE_PUMP_SYRINGE_REMOVED = 178, ///< TD syringe pump syringe removed alarm + ALARM_ID_TD_SYRINGE_PUMP_STALL = 179, ///< TD syringe pump stall alarm + ALARM_ID_TD_HEPARIN_FORCE_SENSOR_INVALID_CAL_RECORD = 180, ///< TD heparin force sensor invalid calibration record + ALARM_ID_TD_SYRINGE_DETECTED = 181, ///< TD syringe detected alarm + ALARM_ID_TD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM = 182, ///< TD syringe pump not enough Heparin alarm + ALARM_ID_TD_SYRINGE_PUMP_OCCLUSION = 183, ///< TD syringe pump occlusion alarm + ALARM_ID_TD_SYRINGE_PUMP_PRIME_TIMEOUT = 184, ///< TD syringe pump prime timeout + ALARM_ID_FP_P9_COND_SENSOR_FPGA_FAULT = 185, ///< FP P9 conductivity sensor fpga fault + ALARM_ID_FP_P18_COND_SENSOR_FPGA_FAULT = 186, ///< FP P18 conductivity sensor fpga fault + ALARM_ID_TD_INVALID_TUBE_SET = 187, ///< TD invalid tube set + ALARM_ID_TD_INSTALL_NEW_BLOOD_TUBING_SET = 188, ///< TD install new blood tubing set + ALARM_ID_TD_INSTALL_NEW_CARTRIDGE = 189, ///< TD install new catridge + ALARM_ID_TD_NO_CARTRIDGE_LOADED = 190, ///< TD no catridge loaded NUM_OF_ALARM_IDS ///< Number of alarms }; typedef enum Alarm_List ALARM_ID_T; ///< Type for alarm list enumeration @@ -363,6 +384,7 @@ { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_FPGA_COMM_TIMEOUT }, { ALARM_PRIORITY_HIGH, 1, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_ALARM_AUDIO_SELF_TEST_FAILURE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_VALVE_CONTROL_FAILURE }, + // Priority Rank Source Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr AutoRes ClrOnly TxLog ID { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_ARTERIAL_SENSOR_TIMEOUT_FAULT }, { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_VENOUS_SENSOR_TIMEOUT_FAULT }, @@ -371,7 +393,7 @@ { ALARM_PRIORITY_LOW, 711, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_VENOUS_BUBBLE_SELF_TEST_FAILURE }, { ALARM_PRIORITY_HIGH, 292, ALM_SRC_TD, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_BLOOD_PRIME_PAUSE_WARNING }, { ALARM_PRIORITY_HIGH, 291, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_BLOOD_PRIME_PAUSE_TIMEOUT }, - { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_VENOUS_SENSOR_TIMEOUT_FAULT }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_VOLTAGE_OUT_OF_RANGE }, { ALARM_PRIORITY_LOW , 852, ALM_SRC_TD, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_AC_POWER_LOST }, { ALARM_PRIORITY_HIGH, 100, ALM_SRC_TD, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , ALARM_ID_TD_AC_POWER_LOST_IN_TREATMENT }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_D17_COND_SENSOR_FPGA_FAULT }, @@ -391,7 +413,8 @@ { ALARM_PRIORITY_LOW, 700, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_VENOUS_PRESSURE_SELF_TEST_FAILURE }, { ALARM_PRIORITY_LOW, 712, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_INSTALL_NEW_BLOOD_TUBING_SET }, { ALARM_PRIORITY_LOW, 713, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_INSTALL_NEW_CARTRIDGE }, - { ALARM_PRIORITY_LOW, 714, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_NO_CARTRIDGE_LOADED }, + { ALARM_PRIORITY_LOW, 714, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_NO_CARTRIDGE_LOADED }, + { ALARM_PRIORITY_LOW, 718, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_INVALID_TUBE_SET }, // Priority Rank Source Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr AutoRes ClrOnly TxLog ID { ALARM_PRIORITY_LOW, 710, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_PRE_TREATMENT_DRY_PRESSURE_TEST_FAILURE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_D11_PUMP_SPEED_CONTROL_ERROR }, @@ -436,7 +459,7 @@ { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_BC_STATE2_FILL_END_PRESSURE_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_GEND_HYD_CHAMBER_PRESS_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_BICARB_FILL_TIMEOUT_FAULT }, - { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_D79_RINSE_PUMP_SPEED_OUT_OF_RANGE }, + { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_D79_RINSE_PUMP_SPEED_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_BC_STATE1_FILL_PRESSURE_DROP_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_DD, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_DD_BC_STATE2_FILL_PRESSURE_DROP_OUT_OF_RANGE }, { ALARM_PRIORITY_MEDIUM, 300, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_TREATMENT_STOPPED_BY_USER }, @@ -445,31 +468,31 @@ { ALARM_PRIORITY_HIGH, 11, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, ALARM_ID_TD_BLOOD_SITTING_TOO_LONG }, { ALARM_PRIORITY_HIGH, 0, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_COMM_TIMEOUT }, // Priority Rank Source Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr AutoRes ClrOnly TxLog ID - { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_OS_VERSION }, - { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_SHASUM }, - { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_CANBUS }, - { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_DISPLAY }, - { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_TOUCH }, - { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_SDCARD }, - { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_RTC }, - { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_WIFI }, - { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_BLUETOOTH }, - { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_ETHERNET }, - { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_SOUND }, - { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_CLOUDSYNC }, - { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_INVALID_YEAR }, - { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_SETTINGS_BAD }, - { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_EVNT_FAILURE_SDCARD }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_116 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_117 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_118 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_119 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_120 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_121 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_122 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_123 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_124 }, - { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_125 }, + { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_OS_VERSION }, + { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_SHASUM }, + { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_CANBUS }, + { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_DISPLAY }, + { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_TOUCH }, + { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_SDCARD }, + { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_RTC }, + { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_WIFI }, + { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_BLUETOOTH }, + { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_ETHERNET }, + { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_SOUND }, + { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_CLOUDSYNC }, + { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_INVALID_YEAR }, + { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_SETTINGS_BAD }, + { ALARM_PRIORITY_HIGH, 1, ALM_SRC_UI, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_EVNT_FAILURE_SDCARD }, + { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_116 }, + { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_117 }, + { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_118 }, + { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_119 }, + { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_120 }, + { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_121 }, + { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_122 }, + { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_123 }, + { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_124 }, + { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_125 }, // Priority Rank Source Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr AutoRes ClrOnly TxLog ID { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_126 }, { ALARM_PRIORITY_LOW, 999, ALM_SRC_UI, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_UI_RESERVED_127 }, @@ -512,6 +535,28 @@ { ALARM_PRIORITY_HIGH, 10, ALM_SRC_FP, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_PERMEATE_FLOW_OUT_LOW_RANGE }, { ALARM_PRIORITY_HIGH, 10, ALM_SRC_FP, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_INLET_PRESSURE_LOW_RANGE }, { ALARM_PRIORITY_HIGH, 13, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , ALARM_ID_TD_AIR_TRAP_LOWER_TIMEOUT }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_SYRINGE_PUMP_SELF_TEST_FAILURE }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_SYRINGE_PUMP_RUNNING_WHILE_BP_OFF_ERROR }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_SYRINGE_PUMP_FPGA_ADC_FAULT }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_SYRINGE_PUMP_FAULT }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_SYRINGE_PUMP_DAC_WRITE_ERROR }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_SYRINGE_PUMP_SPEED_ERROR }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_SYRINGE_PUMP_VOLUME_ERROR }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_SYRINGE_PUMP_OVER_TRAVEL_ERROR }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_SYRINGE_PUMP_NOT_STOPPED_ERROR }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_SYRINGE_PUMP_ENCODER_DIRECTION_ERROR }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_SYRINGE_PUMP_CONTROLLER_DIRECTION_ERROR }, + { ALARM_PRIORITY_LOW, 730, ALM_SRC_TD, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, ALARM_ID_TD_SYRINGE_PUMP_SYRINGE_EMPTY }, + // Priority Rank Source Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr AutoRes ClrOnly TxLog ID + { ALARM_PRIORITY_HIGH, 207, ALM_SRC_TD, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_SYRINGE_PUMP_SYRINGE_REMOVED }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_SYRINGE_PUMP_STALL }, + { ALARM_PRIORITY_HIGH, 1, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_HEPARIN_FORCE_SENSOR_INVALID_CAL_RECORD }, + { ALARM_PRIORITY_LOW, 745, ALM_SRC_TD, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_SYRINGE_DETECTED }, + { ALARM_PRIORITY_LOW, 715, ALM_SRC_TD, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM }, + { ALARM_PRIORITY_LOW, 716, ALM_SRC_TD, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TD_SYRINGE_PUMP_OCCLUSION }, + { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_SYRINGE_PUMP_PRIME_TIMEOUT }, + { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_P9_COND_SENSOR_FPGA_FAULT }, + { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_P18_COND_SENSOR_FPGA_FAULT }, }; // Priority Rank Source Fault DDFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET NoBRcr NoDRcr AutoRes ClrOnly TxLog ID /// Table of alarms and their rank. @@ -541,6 +586,7 @@ { 1, ALARM_ID_DD_BLOOD_LEAK_INVALID_CAL_RECORD }, { 1, ALARM_ID_DD_BLOOD_LEAK_SENSOR_EMBEDDED_MODE_FAILURE }, { 1, ALARM_ID_DD_BLOOD_LEAK_SENSOR_SET_POINT_SET_FAILURE }, + { 1, ALARM_ID_TD_HEPARIN_FORCE_SENSOR_INVALID_CAL_RECORD }, { 10, ALARM_ID_TD_SOFTWARE_FAULT }, { 10, ALARM_ID_TD_UI_COMM_TIMEOUT }, { 10, ALARM_ID_TD_COMM_TOO_MANY_BAD_CRCS }, @@ -563,6 +609,19 @@ { 10, ALARM_ID_FP_PERMEATE_FLOW_OUT_HIGH_RANGE }, { 10, ALARM_ID_FP_PERMEATE_FLOW_OUT_LOW_RANGE }, { 10, ALARM_ID_FP_INLET_PRESSURE_LOW_RANGE }, + { 10, ALARM_ID_TD_SYRINGE_PUMP_RUNNING_WHILE_BP_OFF_ERROR }, + { 10, ALARM_ID_TD_SYRINGE_PUMP_FPGA_ADC_FAULT }, + { 10, ALARM_ID_TD_SYRINGE_PUMP_FAULT }, + { 10, ALARM_ID_TD_SYRINGE_PUMP_DAC_WRITE_ERROR }, + { 10, ALARM_ID_TD_SYRINGE_PUMP_SPEED_ERROR }, + { 10, ALARM_ID_TD_SYRINGE_PUMP_VOLUME_ERROR }, + { 10, ALARM_ID_TD_SYRINGE_PUMP_OVER_TRAVEL_ERROR }, + { 10, ALARM_ID_TD_SYRINGE_PUMP_NOT_STOPPED_ERROR }, + { 10, ALARM_ID_TD_SYRINGE_PUMP_ENCODER_DIRECTION_ERROR }, + { 10, ALARM_ID_TD_SYRINGE_PUMP_CONTROLLER_DIRECTION_ERROR }, + { 10, ALARM_ID_TD_SYRINGE_PUMP_STALL }, + { 10, ALARM_ID_TD_SYRINGE_PUMP_PRIME_TIMEOUT }, + { 10, ALARM_ID_TD_SYRINGE_PUMP_SELF_TEST_FAILURE }, { 11, ALARM_ID_TD_BLOOD_SITTING_TOO_LONG }, { 12, ALARM_ID_TD_VENOUS_BUBBLE_DETECTED }, { 13, ALARM_ID_TD_AIR_TRAP_FILL_TIMEOUT }, @@ -581,6 +640,8 @@ { 110, ALARM_ID_DD_D27_COND_SENSOR_FPGA_FAULT }, { 110, ALARM_ID_DD_D29_COND_SENSOR_FPGA_FAULT }, { 110, ALARM_ID_DD_D43_COND_SENSOR_FPGA_FAULT }, + { 110, ALARM_ID_FP_P9_COND_SENSOR_FPGA_FAULT }, + { 110, ALARM_ID_FP_P18_COND_SENSOR_FPGA_FAULT }, { 110, ALARM_ID_DD_BC_FILL_TIMEOUT_FAULT }, { 110, ALARM_ID_FP_FPGA_COMM_TIMEOUT }, { 110, ALARM_ID_DD_D11_PUMP_SPEED_CONTROL_ERROR }, @@ -646,6 +707,7 @@ { 203, ALARM_ID_TD_ARTERIAL_PRESSURE_HIGH }, { 204, ALARM_ID_TD_TMP_PRESSURE_LOW }, { 205, ALARM_ID_TD_TMP_PRESSURE_HIGH }, + { 207, ALARM_ID_TD_SYRINGE_PUMP_SYRINGE_REMOVED }, { 210, ALARM_ID_TD_CARTRIDGE_DOOR_OPENED }, { 290, ALARM_ID_TD_BLOOD_SITTING_WARNING }, { 291, ALARM_ID_TD_BLOOD_PRIME_PAUSE_TIMEOUT }, @@ -668,6 +730,11 @@ { 712, ALARM_ID_TD_INSTALL_NEW_BLOOD_TUBING_SET }, { 713, ALARM_ID_TD_INSTALL_NEW_CARTRIDGE }, { 714, ALARM_ID_TD_NO_CARTRIDGE_LOADED }, + { 715, ALARM_ID_TD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM }, + { 716, ALARM_ID_TD_SYRINGE_PUMP_OCCLUSION }, + { 718, ALARM_ID_TD_INVALID_TUBE_SET }, + { 730, ALARM_ID_TD_SYRINGE_PUMP_SYRINGE_EMPTY }, + { 745, ALARM_ID_TD_SYRINGE_DETECTED }, { 850, ALARM_ID_BATTERY_LOW }, { 852, ALARM_ID_TD_AC_POWER_LOST }, { 999, ALARM_ID_UI_RESERVED_116 }, @@ -804,7 +871,7 @@ { 90 , ALARM_ID_DD_BC_STATE2_FILL_END_PRESSURE_OUT_OF_RANGE , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: BC Pressure not in range | DD balancing chamber state 2 fill end pressure is not in range | If the fresh dialysate pressure (< 21 psig or > 27 psig) and spent dialysate pressure (< 27 psig or > 31 psig) not in range for balancing chamber state2 fill end. | "}, { 91 , ALARM_ID_DD_GEND_HYD_CHAMBER_PRESS_OUT_OF_RANGE , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: Hyd Cham Neg Pres not in range | DD hydraulics chamber degassing pressure is not in range | If the hydraulics chamber pressure is not less than or equal to calculated target degas pressure psig. | "} { 92 , ALARM_ID_DD_BICARB_FILL_TIMEOUT_FAULT , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Bicarb Chamber fill timeout Error | DD Bicarb chamber fill timeout error | If Bicarb chamber fill time > = 1 seconds | "}, - { 93 , ALARM_ID_DD_D79_RINSE_PUMP_SPEED_OUT_OF_RANGE , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: Rinse Pump Speed Fault | DD D79 rinse pump commanded vs measured speed out of tolerance | If rinse pump measured RPM deviates beyond 10%% of target RPM when pump is commanded on. Data1=measured RPM, Data2=target RPM. | "}, + { 93 , ALARM_ID_DD_D79_RINSE_PUMP_SPEED_OUT_OF_RANGE , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: Rinse Pump Speed Fault | DD D79 rinse pump commanded vs measured speed out of tolerance | If rinse pump measured RPM deviates beyond 10%% of target RPM when pump is commanded on. Data1=measured RPM, Data2=target RPM. | "}, { 94 , ALARM_ID_DD_BC_STATE1_FILL_PRESSURE_DROP_OUT_OF_RANGE , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: BC Pressure not in range | DD balancing chamber state 1 fill initiated and pressure drop is not in range | If the fresh dialysate pressure (< 9 psig or > 13 psig) and spent dialysate pressure (< 9 psig or > 13 psig) not in range for balancing chamber state1 fill in progress. | "}, { 95 , ALARM_ID_DD_BC_STATE2_FILL_PRESSURE_DROP_OUT_OF_RANGE , "DD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DD Fault: BC Pressure not in range | DD balancing chamber state 2 fill initiated and pressure drop is not in range | If the fresh dialysate pressure (< 9 psig or > 13 psig) and spent dialysate pressure (< 9 psig or > 13 psig) not in range for balancing chamber state2 fill in progress. | "}, { 96 , ALARM_ID_TD_TREATMENT_STOPPED_BY_USER , "TD | Blood Pump Stopped: Treatment Paused | Treatment has been stopped by user.\n- Press Resume/OK to resume treatment. \n- If treatment is not resumed within five minutes,\ntreatment will be terminated without rinseback. | Blood Stopped: Treatment Pause | TD treatment stopped by user action - pressed stop button | If the user has pressed the stop button. | "}, @@ -879,10 +946,33 @@ { 162 , ALARM_ID_FP_PERMEATE_FLOW_OUT_HIGH_RANGE , "FP | High Permeate flow | Permeate flow is too high. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Fault: Permeate flow High | Permeate flow is too high from set target flow rate | If the permeate flow is above 25% of set target flow rate for a certain period of time. | "}, { 163 , ALARM_ID_FP_PERMEATE_FLOW_OUT_LOW_RANGE , "FP | low Permeate flow | Permeate flow is too low. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Fault: Permeate flow Low | Permeate flow is too low from set target flow rate | If the permeate flow is above 25% of set target flow rate for a certain period of time. | "}, { 164 , ALARM_ID_FP_INLET_PRESSURE_LOW_RANGE , "FP | low inlet pressure | Inlet pressure is too low. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Fault: Inlet pressure Low | Inlet pressure is too low | If P8 is < 1 PSI | "}, - { 165 , ALARM_ID_TD_AIR_TRAP_LOWER_TIMEOUT , "TD | Blood Pump Stopped: Venous Air Detector | A problem was detected with the venous air detector.\n- Confirm arterial access placement and ensure\nconnections are secure.\n- Treatment must be terminated without rinseback. | Blood Stop: Air Trap Lowering | Air trap lowering timeout during treatment | If the air trap lowering timeout during treatment. | "}, - { 166 , ALARM_ID_TD_INSTALL_NEW_BLOOD_TUBING_SET , "TD | Install New Blood Tubing Set | A problem has been detected during self-test.\n- Fluid detected in the tubing set.\n- Install a new, unused blood tubing set and ensure proper installation. | Process: Pre-Tx Dry Self-Test | TD detected used or wet blood tubing set during self-test | If bubble is detected or air trap levels indicate fluid presence during cartridge verification. | "}, - { 167 , ALARM_ID_TD_INSTALL_NEW_CARTRIDGE , "TD | Install New Cartridge | A problem has been detected during self-test.\n- Cartridge is invalid or not recognized.\n- Install a new cartridge and ensure proper placement. | Process: Pre-Tx Dry Self-Test | TD detected invalid or unreadable cartridge during barcode verification | If barcode scan fails or cartridge identification is unsuccessful. | "}, - { 168 , ALARM_ID_TD_NO_CARTRIDGE_LOADED , "TD | No Cartridge Loaded | A problem has been detected during self-test.\n- Cartridge is not detected.\n- Confirm cartridge is properly installed. | Process: Pre-Tx Dry Self-Test | TD detected no cartridge present during verification | If cartridge presence check fails or no cartridge is detected by the system | "}, + { 165 , ALARM_ID_TD_AIR_TRAP_LOWER_TIMEOUT , "TD | Blood Pump Stopped: Venous Air Detector | A problem was detected with the venous air detector.\n- Confirm arterial access placement and ensure\nconnections are secure.\n- Treatment must be terminated without rinseback. | Blood Stop: Air Trap Lowering | Air trap lowering timeout during treatment | If the air trap lowering timeout during treatment. | "}, + { 166 , ALARM_ID_TD_SYRINGE_PUMP_SELF_TEST_FAILURE , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe DAC | TD syringe pump self-test failure alarm | If the calibration data that was received from NVDataMgmt and the DAC voltage with syringe retracted are not within tol. | "}, + { 167 , ALARM_ID_TD_SYRINGE_PUMP_RUNNING_WHILE_BP_OFF_ERROR , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe Pump On Err | TD syringe pump is running while the BP is off | If the syringe pump is on while the blood pump is off | "}, + { 168 , ALARM_ID_TD_SYRINGE_PUMP_FPGA_ADC_FAULT , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe Pump ADC Com | TD syringe pump ADC error | If the ADC read is not fresh after POST init and the ADC read counter has not changed. | "}, + { 169 , ALARM_ID_TD_SYRINGE_PUMP_FAULT , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe Pump Driver | TD syringe pump fault reported by FPGA | If the FPGA reported the syringe pump fault | "}, + { 170 , ALARM_ID_TD_SYRINGE_PUMP_DAC_WRITE_ERROR , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe Pump DAC Err | TD syringe pump DAC write failure | If the syringe pump DAC write error is reported by the FPGA | "}, + { 171 , ALARM_ID_TD_SYRINGE_PUMP_SPEED_ERROR , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe Pump Speed | TD syringe pump speed check error | If the syringe measured rate is off by more than 5% or 0.1mL. | "}, + { 172 , ALARM_ID_TD_SYRINGE_PUMP_VOLUME_ERROR , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe Pump Vol | TD syringe pump volume check error | If the volume delivered is off by more than 5% or 0.1mL. | "}, + { 173 , ALARM_ID_TD_SYRINGE_PUMP_OVER_TRAVEL_ERROR , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe Pump OT | TD syringe pump over travel error | If the syringe pump position is deemed to have overtraveled | "}, + { 174 , ALARM_ID_TD_SYRINGE_PUMP_NOT_STOPPED_ERROR , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe Pump Speed | TD syringe pump not stopped in off state error | If the syringe pump position is not equal to its last position. | "}, + { 175 , ALARM_ID_TD_SYRINGE_PUMP_ENCODER_DIRECTION_ERROR , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe Pump Enc Dir | TD syringe pump direction (from encoder) error | If the measured encoder direction of the syringe pump does not agree with the expected direction | "}, + { 176 , ALARM_ID_TD_SYRINGE_PUMP_CONTROLLER_DIRECTION_ERROR , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe Pump Drv Dir | TD syringe pump direction (from controller) error | If the measured direction of the syringe pump motor controller does not agree with the expected direction | "}, + // Num Alarm ID Device Display Title Instructions Alarm List Title Description Trigger Condition + { 177 , ALARM_ID_TD_SYRINGE_PUMP_SYRINGE_EMPTY , "TD | Heparin Syringe Empty | Heparin syringe is empty.\n- Treatment will continue without heparin.\n- Refer to facility policy if additional heparin is needed to\ncomplete treatment. | Heparin Syringe Empty | TD syringe empty alarm | If the syringe pump position is near empty position. | "}, + { 178 , ALARM_ID_TD_SYRINGE_PUMP_SYRINGE_REMOVED , "TD | Blood Stopped: Syringe Not Detected | There is a problem detecting a syringe in the heparin pump.\n- Confirm the heparin syringe is properly installed. \n- Press Resume/OK to resume treatment. | Blood Stop: Syringe Not Detected | TD syringe pump syringe removed alarm | If the syringe detection switch < 2.0 volts. | "}, + { 179 , ALARM_ID_TD_SYRINGE_PUMP_STALL , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Syringe Pump Stall | TD syringe pump stall alarm | If syringe pump measured rate < stall speed threshold (0.05) and the ramp up has been restarted 3 times after stall has been detected. | "}, + { 180 , ALARM_ID_TD_HEPARIN_FORCE_SENSOR_INVALID_CAL_RECORD , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD POST: SP DAC Cal | TD heparin force sensor invalid calibration record | If the heparin force sensor calibration data that was received from NVDataMgmt is NOT legitimate. | "}, + { 181 , ALARM_ID_TD_SYRINGE_DETECTED , "TD | Syringe Detected | Heparin syringe was not removed from device.\n- Remove heparin syringe.\n- Press Resume/OK to continue. | Process: Remove Syringe | TD syringe detected alarm | If the syringe detection switch > 2.0 volts. | "}, + { 182 , ALARM_ID_TD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM , "TD | Not Enough Heparin | There is not enough heparin available for treatment.\n- Ensure the syringe pump is touching the syringe plunger.\n- If the syringe pump is touching the syringe plunger,\nend treatment.\n- If syringe pump is not touching the syringe plunger, \nensure the correct amount of heparin has been drawn and\nreload the syringe. | Process: Pre- Tx Not Enough Hep. | TD syringe pump not enough Heparin alarm | If the estimated syringe volume needed for treatment is not sufficient | "}, + { 183 , ALARM_ID_TD_SYRINGE_PUMP_OCCLUSION , "TD | Heparin Pump Occlusion | A problem has been detected with the heparin pump.\n- Ensure heparin line is not kinked or clamped. | Process: Pre- Tx Hep. Pump Occ. | TD syringe pump occlusion alarm | If the pressure sensor voltage reading > SYRINGE_FORCE_OCCLUSION_THRESHOLD_V. | "}, + { 184 , ALARM_ID_TD_SYRINGE_PUMP_PRIME_TIMEOUT , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Pre- Tx Hep. Pump Timeout. | TD syringe pump timeout alarm | If the syringe pump priming > 5 seconds | "}, + { 185 , ALARM_ID_FP_P9_COND_SENSOR_FPGA_FAULT , "FP | Service Required: FP Device | A problem was detected with the FP device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Conductivity Sensor Error | FP conductivity sensor (P9) located in inlet water path reporting error or not being read successfully | Conductvity Sensor (P9) is reporting an error or FPGA is failing to read sensor. | "}, + { 186 , ALARM_ID_FP_P18_COND_SENSOR_FPGA_FAULT , "FP | Service Required: FP Device | A problem was detected with the FP device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Conductivity Sensor Error | FP conductivity sensor (P18) located in inlet water path reporting error or not being read successfully | Conductvity Sensor (P18) is reporting an error or FPGA is failing to read sensor. | "}, + { 187 , ALARM_ID_TD_INVALID_TUBE_SET , "TD | Invalid Tube Set Detected | A problem has been detected during self-test.\n- The installed tube set is not valid.\n- Install a compatible blood tubing set and try again. | Process: Pre-Tx Dry Self-Test | Tube set authentication failed due to invalid tubing set | If the tube set authentication response indicates the installed tube set is invalid. | "}, + { 188 , ALARM_ID_TD_INSTALL_NEW_BLOOD_TUBING_SET , "TD | Install New Blood Tubing Set | A problem has been detected during self-test.\n- Fluid detected in the tubing set.\n- Install a new, unused blood tubing set and ensure proper installation. | Process: Pre-Tx Dry Self-Test | TD detected used or wet blood tubing set during self-test | If bubble is detected or air trap levels indicate fluid presence during cartridge verification. | "}, + { 189 , ALARM_ID_TD_INSTALL_NEW_CARTRIDGE , "TD | Install New Cartridge | A problem has been detected during self-test.\n- Cartridge is invalid or not recognized.\n- Install a new cartridge and ensure proper placement. | Process: Pre-Tx Dry Self-Test | TD detected invalid or unreadable cartridge during barcode verification | If barcode scan fails or cartridge identification is unsuccessful. | "}, + { 190 , ALARM_ID_TD_NO_CARTRIDGE_LOADED , "TD | No Cartridge Loaded | A problem has been detected during self-test.\n- Cartridge is not detected.\n- Confirm cartridge is properly installed. | Process: Pre-Tx Dry Self-Test | TD detected no cartridge present during verification | If cartridge presence check fails or no cartridge is detected by the system | "}, }; #endif // manual alarms Index: MsgDefs.h =================================================================== diff -u -r57fc86514c26dc2a9d45f55696a19824385fadea -r8f4c7a14f0ed74c238c7c72a316a026e50dc3cec --- MsgDefs.h (.../MsgDefs.h) (revision 57fc86514c26dc2a9d45f55696a19824385fadea) +++ MsgDefs.h (.../MsgDefs.h) (revision 8f4c7a14f0ed74c238c7c72a316a026e50dc3cec) @@ -8,8 +8,8 @@ * * @file MsgDefs.h * -* @author (last) Raghu Kallala -* @date (last) 06-Apr-2026 +* @author (last) Michael Garthwaite +* @date (last) 07-Apr-2026 * * @author (original) Sean Nash * @date (original) 01-Aug-2024 @@ -273,187 +273,187 @@ MSG_ID_TD_BLOOD_PRIME_VOLUME_OVERRIDE = 0x8045, ///< TD blood prime override. MSG_ID_TD_BLOOD_PRIME_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0x8046, ///< TD blood prime publish interval broadcast override. MSG_ID_TD_ENABLE_VENOUS_BUBBLE_ALARM = 0x8047, ///< TD enable venous bubble alarm. - MSG_ID_TD_NO_CART_SELF_TEST_PROGRESS_DATA = 0x8048, ///< TD No cart self test progress data + MSG_ID_TD_DRY_SELF_TEST_PROGRESS_DATA = 0x8048, ///< TD dry self test progress data MSG_ID_TD_TUBE_SET_AUTHENTICATION_RESPONSE = 0x8049, ///< TD Tube set authentication response - MSG_ID_FIRST_DD_TESTER_MESSAGE = 0xA000, ///< First DD test message ID - MSG_ID_DD_TESTER_LOGIN_REQUEST = MSG_ID_FIRST_DD_TESTER_MESSAGE, ///< DD tester log-in - MSG_ID_DD_SOFTWARE_RESET_REQUEST = 0xA001, ///< DD reset request - MSG_ID_DD_SEND_TEST_CONFIGURATION = 0xA002, ///< DD send test configuration to Dialin - MSG_ID_DD_VALVE_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA003, ///< DD valve publish interval override request - MSG_ID_DD_VALVE_STATE_OVERRIDE_REQUEST = 0xA004, ///< DD valve state override request - MSG_ID_DD_VALVE_SENSED_STATE_OVERRIDE_REQUEST = 0xA005, ///< DD valve sensed state override request - MSG_ID_DD_PRESSURE_SENSOR_READINGS_OVERRIDE_REQUEST = 0xA006, ///< DD pressure sensor override request - MSG_ID_DD_PRESSURE_SENSOR_TEMPERATURE_OVERRIDE_REQUEST = 0xA007, ///< DD pressure sensor temperature override request - MSG_ID_DD_TREATMENT_PARAMS_OVERRIDE_REQUEST = 0xA008, ///< DD Treatment parameters override request - MSG_ID_AVAILABLE_3 = 0xA009, ///< DD Msg ID not used - available for use. - MSG_ID_DD_PRESSURE_SENSOR_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA00A, ///< DD pressure sensor publish interval override request - MSG_ID_DD_PRESSURE_SENSOR_FILTER_READINGS_OVERRIDE_REQUEST = 0xA00B, ///< DD pressure sensor filter readings override request - MSG_ID_DD_PRESSURE_SENSOR_FILTER_TEMPERATURE_OVERRIDE_REQUEST = 0xA00C, ///< DD pressure sensor filter temperature override request - MSG_ID_DD_CONDUCTIVITY_SENSOR_READINGS_OVERRIDE_REQUEST = 0xA00D, ///< DD conductivity sensor reading override request - MSG_ID_DD_CONDUCTIVITY_SENSOR_TEMPERATURE_OVERRIDE_REQUEST = 0xA00E, ///< DD conductivity sensor temperature override request - MSG_ID_DD_CONDUCTIVITY_SENSOR_READ_COUNTER_OVERRIDE_REQUEST = 0xA00F, ///< DD conductivity sensor read counter request - MSG_ID_DD_CONDUCTIVITY_SENSOR_ERROR_COUNTER_OVERRIDE_REQUEST = 0xA010, ///< DD conductivity sensor error counter request - MSG_ID_DD_CONDUCTIVITY_SENSOR_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA011, ///< DD conductivity sensor publish interval override request - MSG_ID_DD_CONCENTRATE_PUMP_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA012, ///< DD concentrate pump publish interval override request - MSG_ID_DD_CONCENTRATE_PUMP_TARGET_SPEED_OVERRIDE_REQUEST = 0xA013, ///< DD concentrate pump target speed override request - MSG_ID_DD_CONCENTRATE_PUMP_MEASURED_SPEED_OVERRIDE_REQUEST = 0xA014, ///< DD concentrate pump measured speed override request - MSG_ID_DD_CONCENTRATE_PUMP_PARKED_OVERRIDE_REQUEST = 0xA015, ///< DD concentrate pump parked override request - MSG_ID_DD_CONCENTRATE_PUMP_PARK_FAULT_OVERRIDE_REQUEST = 0xA016, ///< DD concentrate pump park fault override request - MSG_ID_DD_CONCENTRATE_PUMP_PARK_REQUEST_OVERRIDE_REQUEST = 0xA017, ///< DD concentrate pump park request override request - MSG_ID_DD_TEMPERATURE_SENSOR_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA018, ///< DD temperature sensor publish interval override request - MSG_ID_DD_TEMPERATURE_SENSOR_MEASURED_TEMPERATURE_OVERRIDE_REQUEST = 0xA019, ///< DD temperature sensor measured temperature override request - MSG_ID_DD_TEMPERATURE_SENSOR_READ_COUNTER_OVERRIDE_REQUEST = 0xA01A, ///< DD temperature sensor read counter override request - MSG_ID_DD_TEMPERATURE_SENSOR_FILTERED_TEMP_OVERRIDE_REQUEST = 0xA01B, ///< DD temperature sensor filtered temperature override request. - MSG_ID_DD_AVAILABLE_3 = 0xA01C, ///< DD Msg ID not used - available for use. - MSG_ID_DD_DIALYSATE_PUMPS_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA01D, ///< DD dialysate pumps data publish interval override request - MSG_ID_DD_DIALYSATE_PUMPS_TARGET_SPEED_OVERRIDE_REQUEST = 0xA01E, ///< DD dialysate pumps target speed override request - MSG_ID_DD_DIALYSATE_PUMPS_MEASURED_SPEED_OVERRIDE_REQUEST = 0xA01F, ///< DD dialysate pumps measured speed override request - MSG_ID_DD_DIALYSATE_PUMPS_TARGET_PRESSURE_OVERRIDE_REQUEST = 0xA020, ///< DD dialysate pumps target pressure override request - MSG_ID_DD_DIALYSATE_PUMPS_MEASURED_CURRENT_OVERRIDE_REQUEST = 0xA021, ///< DD dialysate pumps measured current override request - MSG_ID_DD_DIALYSATE_PUMPS_MEASURED_DIRECTION_OVERRIDE_REQUEST = 0xA022, ///< DD dialysate pumps measured direction override request - MSG_ID_DD_HEATERS_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA023, ///< DD heaters data publish interval override request - MSG_ID_DD_HEATERS_DUTY_CYCLE_OVERRIDE_REQUEST = 0xA024, ///< DD heaters dutycycle override request - MSG_ID_DD_LEVELS_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA025, ///< DD levels data publish interval override request - MSG_ID_DD_LEVELS_STATUS_OVERRIDE_REQUEST = 0xA026, ///< DD levels status override request - MSD_ID_DD_TD_COMMUNICATION_STATUS_OVERRIDE_REQUEST = 0xA027, ///< DD TD CAN Communication status override request - MSG_ID_DD_OP_MODE_STATUS_OVERRIDE_REQUEST = 0xA028, ///< DD operation mode status override request - MSG_ID_DD_SET_OPERATION_MODE_OVERRIDE_REQUEST = 0xA029, ///< DD set new operation mode override request - MSG_ID_DD_UF_DATA_PUBLISH_OVERRIDE_REQUEST = 0xA03E, ///< DD ultrafiltration data publish interval override request - MSG_ID_DD_DIALYSATE_PUMPS_START_STOP_OVERRIDE_REQUEST = 0xA02B, ///< DD dialysate pumps start/stop override request - MSG_ID_DD_GEND_MODE_DATA_PUBLISH_OVERRIDE_REQUEST = 0xA02C, ///< DD generate dialysate mode data publish interval override request - MSG_ID_DD_CONCENTRATE_PUMPS_START_STOP_OVERRIDE_REQUEST = 0xA02D, ///< DD Concentrate pumps start/stop override request - MSG_ID_DD_HEATERS_START_STOP_OVERRIDE_REQUEST = 0xA02E, ///< DD Heaters start override request - MSG_ID_DD_VALVES_OPEN_CLOSE_STATE_OVERRIDE_REQUEST = 0xA02F, ///< DD Valves open/close state override request - MSD_ID_DD_FP_COMMUNICATION_STATUS_OVERRIDE_REQUEST = 0xA030, ///< DD FP CAN Communication status override request - MSG_ID_DD_BAL_CHAMBER_DATA_PUBLISH_OVERRIDE_REQUEST = 0xA031, ///< DD balance chamber data publish interval override request - MSG_ID_DD_BAL_CHAMBER_SWITCH_FREQ_OVERRIDE_REQUEST = 0xA032, ///< DD balance chamber switching frequency override request - MSG_ID_DD_DIAL_DELIVERY_IN_PROGRESS_OVERRIDE_REQUEST = 0xA033, ///< DD dialysate delivery in progress override request - MSG_ID_DD_DIAL_DELIVERY_GOOD_TO_DELIVER_OVERRIDE_REQUEST = 0xA034, ///< DD dialysate delivery good to deliver override request - MSG_ID_DD_HEATERS_TARGET_TEMPERATURE_OVERRIDE_REQUEST = 0xA035, ///< DD heaters target temperature override request - MSG_ID_DD_BC_VALVE_STATES_OVERRIDE_REQUEST = 0xA036, ///< DD balancing chamber valve states override request - MSG_ID_DD_BC_SWITCH_ONLY_START_STOP_OVERRIDE_REQUEST = 0xA037, ///< DD balancing chamber switch only start/stop override request - MSG_ID_DD_HYD_CHAMBER_TARGET_TEMP_OVERRIDE_REQUEST = 0xA038, ///< DD Hydraulic chamber target temperature override request - MSG_ID_DD_ACID_DOSING_VOLUME_OVERRIDE_REQUEST = 0xA039, ///< DD acid dosing volume override request - MSG_ID_DD_BICARB_DOSING_VOLUME_OVERRIDE_REQUEST = 0xA03A, ///< DD bicarb dosing volume override request - MSG_ID_DD_GEND_EXEC_STATE_OVERRIDE_REQUEST = 0xA03B, ///< DD GenD execution state override request - MSG_ID_DD_HEATERS_PWM_PERIOD_OVERIDE_REQUEST = 0xA03C, ///< DD heaters PWM period override request - MSG_ID_DD_PRE_GEND_MODE_DATA_PUBLISH_OVERRIDE_REQUEST = 0xA03D, ///< DD Pre generate dialysate mode data publish interval override request - MSG_ID_DD_POST_GEND_MODE_DATA_PUBLISH_OVERRIDE_REQUEST = 0xA03E, ///< DD Post generate dialysate mode data publish interval override request - MSG_ID_DD_SEND_BLOOD_LEAK_EMB_MODE_RESPONSE = 0xA03F, ///< DD send blood embedded mode response - MSG_ID_DD_SPENT_CHAMB_FILL_DATA_PUBLISH_OVERRIDE_REQUEST = 0xA040, ///< DD stop pre-gen dialysate mode override request - MSG_ID_DD_AVAILABLE_TO_USE_4 = 0xA041, ///< DD stop gen dialysate mode override request - MSG_ID_DD_SAFETY_SHUTDOWN_OVERRIDE_REQUEST = 0xA042, ///< DD set/reset safety shutdown override request - MSG_ID_DD_SET_TEST_CONFIGURATION = 0xA043, ///< DD set test configuration - MSG_ID_DD_GET_TEST_CONFIGURATION = 0xA044, ///< DD get test configuration - MSG_ID_DD_RESET_ALL_TEST_CONFIGURATIONS = 0xA045, ///< DD reset all the configurations - MSG_ID_AVAILABLE_1 = 0xA046, ///< Msg ID not used - available for use. - MSG_ID_DD_BLOOD_LEAK_DATA_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA047, ///< DD blood leak data publish interval override request - MSG_ID_DD_BLOOD_LEAK_STATUS_OVERRIDE_REQUEST = 0xA048, ///< DD blood leak status override request - MSG_ID_DD_BLOOD_LEAK_SET_TO_EMBEDDED_MODE_REQUEST = 0xA049, ///< DD blood leak set to embedded mode request - MSG_ID_DD_BLOOD_LEAK_SET_EMBEDDED_MODE_CMD_REQUEST = 0xA04A, ///< DD blood leak set embedded more command request - MSG_ID_DD_BLOOD_LEAK_EMBEDDED_MODE_INFO_OVERRIDE_REQUEST = 0xA04B, ///< DD blood leak embedded mode information override request - MSG_ID_DD_BLOOD_LEAK_INTENSITY_MOVING_AVERAGE_OVERRIDE_REQUEST = 0xA04C, ///< DD blood leak intensity moving average override request - MSG_ID_DD_BLOOD_LEAK_ZEROING_INTERVAL_IN_MS_OVERRIDE_REQUEST = 0xA04D, ///< DD blood leak zeroing interval in milliseconds override request - MSG_ID_DD_BLOOD_LEAK_ZERO_REQUEST = 0xA04E, ///< DD blood leak zero request - MSG_ID_DD_FILTERED_COND_SENSOR_READINGS_OVERRIDE_REQUEST = 0xA04F, ///< DD filtered conductivity sensor reading override request - MSG_ID_DD_FILTERED_COND_SENSOR_TEMPERATURE_OVERRIDE_REQUEST = 0xA050, ///< DD filtered conductivity sensor temperature override request - MSG_ID_DD_VOLTAGE_DATA_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA051, ///< DD monitored voltage data publish interval override request - MSG_ID_DD_MONITORED_VOLTAGE_OVERRIDE_REQUEST = 0xA052, ///< DD monitored voltage override request - MSG_ID_DD_RINSE_PUMP_DATA_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA053, ///< DD rinse pump broadcast data override request - MSG_ID_DD_RINSE_PUMP_PWM_PERCENT_OVERRIDE_REQUEST = 0xA054, ///< DD rinse pump PWM percent override request - MSG_ID_DD_RINSE_PUMP_TURN_ON_OFF_REQUEST = 0xA055, ///< DD rinse pump turn on/off request - MSG_ID_DD_DRY_BICART_DATA_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA056, ///< DD dry bicart broadcast data overrride request - MSG_ID_DD_DRY_BICART_FILL_CYCLE_MAX_OVERRIDE_REQUEST = 0xA057, ///< DD dry bicart fill cycle max count overrride request - MSG_ID_DD_DRY_BICART_FILL_REQUEST_OVERRIDE_REQUEST = 0xA058, ///< DD dry bicart fill request overrride request - MSG_ID_DD_BICARB_CHAMBER_FILL_REQUEST_OVERRIDE_REQUEST = 0xA059, ///< DD bicarb chamber fill request overrride request - MSG_ID_DD_BICART_DRAIN_REQUEST_OVERRIDE_REQUEST = 0xA05A, ///< DD bicarb drain request overrride request - MSG_ID_DD_BICART_CARTRIDGE_SELECT_OVERRIDE_REQUEST = 0xA05B, ///< DD bicarb cartridge select(small-0, large-1) overrride request + MSG_ID_FIRST_DD_TESTER_MESSAGE = 0xA000, ///< First DD test message ID + MSG_ID_DD_TESTER_LOGIN_REQUEST = MSG_ID_FIRST_DD_TESTER_MESSAGE, ///< DD tester log-in + MSG_ID_DD_SOFTWARE_RESET_REQUEST = 0xA001, ///< DD reset request + MSG_ID_DD_SEND_TEST_CONFIGURATION = 0xA002, ///< DD send test configuration to Dialin + MSG_ID_DD_VALVE_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA003, ///< DD valve publish interval override request + MSG_ID_DD_VALVE_STATE_OVERRIDE_REQUEST = 0xA004, ///< DD valve state override request + MSG_ID_DD_VALVE_SENSED_STATE_OVERRIDE_REQUEST = 0xA005, ///< DD valve sensed state override request + MSG_ID_DD_PRESSURE_SENSOR_READINGS_OVERRIDE_REQUEST = 0xA006, ///< DD pressure sensor override request + MSG_ID_DD_PRESSURE_SENSOR_TEMPERATURE_OVERRIDE_REQUEST = 0xA007, ///< DD pressure sensor temperature override request + MSG_ID_DD_TREATMENT_PARAMS_OVERRIDE_REQUEST = 0xA008, ///< DD Treatment parameters override request + MSG_ID_AVAILABLE_3 = 0xA009, ///< DD Msg ID not used - available for use. + MSG_ID_DD_PRESSURE_SENSOR_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA00A, ///< DD pressure sensor publish interval override request + MSG_ID_DD_PRESSURE_SENSOR_FILTER_READINGS_OVERRIDE_REQUEST = 0xA00B, ///< DD pressure sensor filter readings override request + MSG_ID_DD_PRESSURE_SENSOR_FILTER_TEMPERATURE_OVERRIDE_REQUEST = 0xA00C, ///< DD pressure sensor filter temperature override request + MSG_ID_DD_CONDUCTIVITY_SENSOR_READINGS_OVERRIDE_REQUEST = 0xA00D, ///< DD conductivity sensor reading override request + MSG_ID_DD_CONDUCTIVITY_SENSOR_TEMPERATURE_OVERRIDE_REQUEST = 0xA00E, ///< DD conductivity sensor temperature override request + MSG_ID_DD_CONDUCTIVITY_SENSOR_CONDUCTIVITY_READ_COUNTER_OVERRIDE_REQUEST = 0xA00F, ///< DD conductivity sensor read counter request + MSG_ID_DD_CONDUCTIVITY_SENSOR_CONDUCTIVITY_ERROR_COUNTER_OVERRIDE_REQUEST = 0xA010, ///< DD conductivity sensor error counter request + MSG_ID_DD_CONDUCTIVITY_SENSOR_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA011, ///< DD conductivity sensor publish interval override request + MSG_ID_DD_CONCENTRATE_PUMP_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA012, ///< DD concentrate pump publish interval override request + MSG_ID_DD_CONCENTRATE_PUMP_TARGET_SPEED_OVERRIDE_REQUEST = 0xA013, ///< DD concentrate pump target speed override request + MSG_ID_DD_CONCENTRATE_PUMP_MEASURED_SPEED_OVERRIDE_REQUEST = 0xA014, ///< DD concentrate pump measured speed override request + MSG_ID_DD_CONCENTRATE_PUMP_PARKED_OVERRIDE_REQUEST = 0xA015, ///< DD concentrate pump parked override request + MSG_ID_DD_CONCENTRATE_PUMP_PARK_FAULT_OVERRIDE_REQUEST = 0xA016, ///< DD concentrate pump park fault override request + MSG_ID_DD_CONCENTRATE_PUMP_PARK_REQUEST_OVERRIDE_REQUEST = 0xA017, ///< DD concentrate pump park request override request + MSG_ID_DD_TEMPERATURE_SENSOR_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA018, ///< DD temperature sensor publish interval override request + MSG_ID_DD_TEMPERATURE_SENSOR_MEASURED_TEMPERATURE_OVERRIDE_REQUEST = 0xA019, ///< DD temperature sensor measured temperature override request + MSG_ID_DD_TEMPERATURE_SENSOR_READ_COUNTER_OVERRIDE_REQUEST = 0xA01A, ///< DD temperature sensor read counter override request + MSG_ID_DD_TEMPERATURE_SENSOR_FILTERED_TEMP_OVERRIDE_REQUEST = 0xA01B, ///< DD temperature sensor filtered temperature override request. + MSG_ID_DD_AVAILABLE_3 = 0xA01C, ///< DD Msg ID not used - available for use. + MSG_ID_DD_DIALYSATE_PUMPS_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA01D, ///< DD dialysate pumps data publish interval override request + MSG_ID_DD_DIALYSATE_PUMPS_TARGET_SPEED_OVERRIDE_REQUEST = 0xA01E, ///< DD dialysate pumps target speed override request + MSG_ID_DD_DIALYSATE_PUMPS_MEASURED_SPEED_OVERRIDE_REQUEST = 0xA01F, ///< DD dialysate pumps measured speed override request + MSG_ID_DD_DIALYSATE_PUMPS_TARGET_PRESSURE_OVERRIDE_REQUEST = 0xA020, ///< DD dialysate pumps target pressure override request + MSG_ID_DD_DIALYSATE_PUMPS_MEASURED_CURRENT_OVERRIDE_REQUEST = 0xA021, ///< DD dialysate pumps measured current override request + MSG_ID_DD_DIALYSATE_PUMPS_MEASURED_DIRECTION_OVERRIDE_REQUEST = 0xA022, ///< DD dialysate pumps measured direction override request + MSG_ID_DD_HEATERS_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA023, ///< DD heaters data publish interval override request + MSG_ID_DD_HEATERS_DUTY_CYCLE_OVERRIDE_REQUEST = 0xA024, ///< DD heaters dutycycle override request + MSG_ID_DD_LEVELS_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA025, ///< DD levels data publish interval override request + MSG_ID_DD_LEVELS_STATUS_OVERRIDE_REQUEST = 0xA026, ///< DD levels status override request + MSD_ID_DD_TD_COMMUNICATION_STATUS_OVERRIDE_REQUEST = 0xA027, ///< DD TD CAN Communication status override request + MSG_ID_DD_OP_MODE_STATUS_OVERRIDE_REQUEST = 0xA028, ///< DD operation mode status override request + MSG_ID_DD_SET_OPERATION_MODE_OVERRIDE_REQUEST = 0xA029, ///< DD set new operation mode override request + MSG_ID_DD_UF_DATA_PUBLISH_OVERRIDE_REQUEST = 0xA03E, ///< DD ultrafiltration data publish interval override request + MSG_ID_DD_DIALYSATE_PUMPS_START_STOP_OVERRIDE_REQUEST = 0xA02B, ///< DD dialysate pumps start/stop override request + MSG_ID_DD_GEND_MODE_DATA_PUBLISH_OVERRIDE_REQUEST = 0xA02C, ///< DD generate dialysate mode data publish interval override request + MSG_ID_DD_CONCENTRATE_PUMPS_START_STOP_OVERRIDE_REQUEST = 0xA02D, ///< DD Concentrate pumps start/stop override request + MSG_ID_DD_HEATERS_START_STOP_OVERRIDE_REQUEST = 0xA02E, ///< DD Heaters start override request + MSG_ID_DD_VALVES_OPEN_CLOSE_STATE_OVERRIDE_REQUEST = 0xA02F, ///< DD Valves open/close state override request + MSD_ID_DD_FP_COMMUNICATION_STATUS_OVERRIDE_REQUEST = 0xA030, ///< DD FP CAN Communication status override request + MSG_ID_DD_BAL_CHAMBER_DATA_PUBLISH_OVERRIDE_REQUEST = 0xA031, ///< DD balance chamber data publish interval override request + MSG_ID_DD_BAL_CHAMBER_SWITCH_FREQ_OVERRIDE_REQUEST = 0xA032, ///< DD balance chamber switching frequency override request + MSG_ID_DD_DIAL_DELIVERY_IN_PROGRESS_OVERRIDE_REQUEST = 0xA033, ///< DD dialysate delivery in progress override request + MSG_ID_DD_DIAL_DELIVERY_GOOD_TO_DELIVER_OVERRIDE_REQUEST = 0xA034, ///< DD dialysate delivery good to deliver override request + MSG_ID_DD_HEATERS_TARGET_TEMPERATURE_OVERRIDE_REQUEST = 0xA035, ///< DD heaters target temperature override request + MSG_ID_DD_BC_VALVE_STATES_OVERRIDE_REQUEST = 0xA036, ///< DD balancing chamber valve states override request + MSG_ID_DD_BC_SWITCH_ONLY_START_STOP_OVERRIDE_REQUEST = 0xA037, ///< DD balancing chamber switch only start/stop override request + MSG_ID_DD_HYD_CHAMBER_TARGET_TEMP_OVERRIDE_REQUEST = 0xA038, ///< DD Hydraulic chamber target temperature override request + MSG_ID_DD_ACID_DOSING_VOLUME_OVERRIDE_REQUEST = 0xA039, ///< DD acid dosing volume override request + MSG_ID_DD_BICARB_DOSING_VOLUME_OVERRIDE_REQUEST = 0xA03A, ///< DD bicarb dosing volume override request + MSG_ID_DD_GEND_EXEC_STATE_OVERRIDE_REQUEST = 0xA03B, ///< DD GenD execution state override request + MSG_ID_DD_HEATERS_PWM_PERIOD_OVERIDE_REQUEST = 0xA03C, ///< DD heaters PWM period override request + MSG_ID_DD_PRE_GEND_MODE_DATA_PUBLISH_OVERRIDE_REQUEST = 0xA03D, ///< DD Pre generate dialysate mode data publish interval override request + MSG_ID_DD_POST_GEND_MODE_DATA_PUBLISH_OVERRIDE_REQUEST = 0xA03E, ///< DD Post generate dialysate mode data publish interval override request + MSG_ID_DD_SEND_BLOOD_LEAK_EMB_MODE_RESPONSE = 0xA03F, ///< DD send blood embedded mode response + MSG_ID_DD_SPENT_CHAMB_FILL_DATA_PUBLISH_OVERRIDE_REQUEST = 0xA040, ///< DD stop pre-gen dialysate mode override request + MSG_ID_DD_AVAILABLE_TO_USE_4 = 0xA041, ///< DD stop gen dialysate mode override request + MSG_ID_DD_SAFETY_SHUTDOWN_OVERRIDE_REQUEST = 0xA042, ///< DD set/reset safety shutdown override request + MSG_ID_DD_SET_TEST_CONFIGURATION = 0xA043, ///< DD set test configuration + MSG_ID_DD_GET_TEST_CONFIGURATION = 0xA044, ///< DD get test configuration + MSG_ID_DD_RESET_ALL_TEST_CONFIGURATIONS = 0xA045, ///< DD reset all the configurations + MSG_ID_AVAILABLE_1 = 0xA046, ///< Msg ID not used - available for use. + MSG_ID_DD_BLOOD_LEAK_DATA_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA047, ///< DD blood leak data publish interval override request + MSG_ID_DD_BLOOD_LEAK_STATUS_OVERRIDE_REQUEST = 0xA048, ///< DD blood leak status override request + MSG_ID_DD_BLOOD_LEAK_SET_TO_EMBEDDED_MODE_REQUEST = 0xA049, ///< DD blood leak set to embedded mode request + MSG_ID_DD_BLOOD_LEAK_SET_EMBEDDED_MODE_CMD_REQUEST = 0xA04A, ///< DD blood leak set embedded more command request + MSG_ID_DD_BLOOD_LEAK_EMBEDDED_MODE_INFO_OVERRIDE_REQUEST = 0xA04B, ///< DD blood leak embedded mode information override request + MSG_ID_DD_BLOOD_LEAK_INTENSITY_MOVING_AVERAGE_OVERRIDE_REQUEST = 0xA04C, ///< DD blood leak intensity moving average override request + MSG_ID_DD_BLOOD_LEAK_ZEROING_INTERVAL_IN_MS_OVERRIDE_REQUEST = 0xA04D, ///< DD blood leak zeroing interval in milliseconds override request + MSG_ID_DD_BLOOD_LEAK_ZERO_REQUEST = 0xA04E, ///< DD blood leak zero request + MSG_ID_DD_FILTERED_COND_SENSOR_READINGS_OVERRIDE_REQUEST = 0xA04F, ///< DD filtered conductivity sensor reading override request + MSG_ID_DD_FILTERED_COND_SENSOR_TEMPERATURE_OVERRIDE_REQUEST = 0xA050, ///< DD filtered conductivity sensor temperature override request + MSG_ID_DD_VOLTAGE_DATA_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA051, ///< DD monitored voltage data publish interval override request + MSG_ID_DD_MONITORED_VOLTAGE_OVERRIDE_REQUEST = 0xA052, ///< DD monitored voltage override request + MSG_ID_DD_RINSE_PUMP_DATA_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA053, ///< DD rinse pump broadcast data override request + MSG_ID_DD_RINSE_PUMP_PWM_PERCENT_OVERRIDE_REQUEST = 0xA054, ///< DD rinse pump PWM percent override request + MSG_ID_DD_RINSE_PUMP_TURN_ON_OFF_REQUEST = 0xA055, ///< DD rinse pump turn on/off request + MSG_ID_DD_DRY_BICART_DATA_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xA056, ///< DD dry bicart broadcast data overrride request + MSG_ID_DD_DRY_BICART_FILL_CYCLE_MAX_OVERRIDE_REQUEST = 0xA057, ///< DD dry bicart fill cycle max count overrride request + MSG_ID_DD_DRY_BICART_FILL_REQUEST_OVERRIDE_REQUEST = 0xA058, ///< DD dry bicart fill request overrride request + MSG_ID_DD_BICARB_CHAMBER_FILL_REQUEST_OVERRIDE_REQUEST = 0xA059, ///< DD bicarb chamber fill request overrride request + MSG_ID_DD_BICART_DRAIN_REQUEST_OVERRIDE_REQUEST = 0xA05A, ///< DD bicarb drain request overrride request + MSG_ID_DD_BICART_CARTRIDGE_SELECT_OVERRIDE_REQUEST = 0xA05B, ///< DD bicarb cartridge select(small-0, large-1) overrride request + MSG_ID_DD_SET_CONDUCTIVITY_MODEL_REQUEST = 0xA05C, ///< DD set conductivity model to conductivity sensors ( also applies to FP conductivity sensors ) + MSG_ID_DD_CONDUCTIVITY_SENSOR_RESISTANCE_OVERRIDE_REQUEST = 0xA05D, ///< DD conductivity sensor resistance override request + MSG_ID_DD_CONDUCTIVITY_SENSOR_VERSION_REQUEST = 0xB05E, ///< DD conductivity sensor version request + MSG_ID_DD_CONDUCTIVITY_SENSOR_VERSION_RESPONSE = 0xB05F, ///< DD conductivity sensor version response -#ifdef __TEENSY_CONDUCTIVITY_DRIVER__ - MSG_ID_DD_SET_CONDUCTIVITY_MODEL_REQUEST = 0xA100, ///< DD set conductivity model to conductivity sensors ( also applies to FP conductivity sensors ) - MSG_ID_DD_CONDUCTIVITY_SENSOR_RESISTANCE_OVERRIDE_REQUEST = 0xA101, ///< DD conductivity sensor resistance override request -#endif + MSG_ID_FIRST_FP_TESTER_MESSAGE = 0xB000, ///< First FP test message ID + MSG_ID_FP_TESTER_LOGIN_REQUEST = MSG_ID_FIRST_FP_TESTER_MESSAGE, ///< FP tester log-in + MSG_ID_FP_SOFTWARE_RESET_REQUEST = 0xB001, ///< FP reset request + MSG_ID_FP_SEND_TEST_CONFIGURATION = 0xB002, ///< FP send test configuration to Dialin + MSG_ID_FP_VALVE_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB003, ///< FP valve data publish interval override request + MSG_ID_FP_VALVE_CMD_STATE_OVERRIDE_REQUEST = 0xB004, ///< FP valve commanded state override request + MSG_ID_FP_VALVE_SENSED_STATE_OVERRIDE_REQUEST = 0xB005, ///< FP valve sensed state override request + MSG_ID_FP_FLUID_PUMP_SET_PWM_REQUEST = 0xB006, ///< FP set boost pump PWM request + MSG_ID_FP_FLUID_PUMP_READ_PWM_OVERRIDE_REQUEST = 0xB007, ///< FP override request for boost pump read PWM + MSG_ID_FP_FLUID_PUMP_SPEED_OVERRIDE_REQUEST = 0xB008, ///< FP override request for boost pump speed (RPM) + MSG_ID_FP_RO_PUMP_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB009, ///< FP boost pumps data publish interval override request + MSG_ID_FP_PRESSURE_OVERRIDE_REQUEST = 0xB00A, ///< FP override request for pressure (mmHg) + MSG_ID_FP_PRESSURE_TEMP_OVERRIDE_REQUEST = 0xB00B, ///< FP override request for pressure sensor temperature (deg C) + MSG_ID_FP_PRESSURE_SENSOR_FILTER_READINGS_OVERRIDE_REQUEST = 0xB00C, ///< FP pressure sensor filter readings override request + MSG_ID_FP_PRESSURE_SENSOR_FILTER_TEMPERATURE_OVERRIDE_REQUEST = 0xB00D, ///< FP pressure sensor filter temperature override request + MSG_ID_FP_PRESSURE_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB00E, ///< FP pressures data publish interval override request + MSG_ID_FP_LEVEL_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB00F, ///< FP level data publish interval override request + MSG_ID_FP_LEVEL_OVERRIDE_REQUEST = 0xB010, ///< FP override request for level sensor. + MSG_ID_FP_FLOWS_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB011, ///< FP flows data publish interval override request + MSG_ID_FP_FLOW_RATE_OVERRIDE_REQUEST = 0xB012, ///< FP override request for flow rate (mL/min) + MSG_ID_FP_FLOW_TEMP_OVERRIDE_REQUEST = 0xB013, ///< FP override request for flow temperature (deg C) + MSG_ID_FP_CONDUCTIVITY_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB014, ///< FP conductivity data publish interval override request + MSG_ID_FP_CONDUCTIVITY_SENSOR_READINGS_OVERRIDE_REQUEST = 0xB015, ///< FP conductivity override request + MSG_ID_FP_CONDUCTIVITY_SENSOR_TEMPERATURE_OVERRIDE_REQUEST = 0xB016, ///< FP conductivity sensor temperature override request + MSG_ID_FP_CONDUCTIVITY_SENSOR_CONDUCTIVITY_READ_COUNT_OVERRIDE_REQUEST = 0xB017, ///< FP conductivity sensor read count override request + MSG_ID_FP_CONDUCTIVITY_SENSOR_CONDUCTIVITY_ERROR_COUNT_OVERRIDE_REQUEST = 0xB018, ///< FP conductivity sensor error count override request + MSG_ID_FP_TEMPERATURE_OVERRIDE_REQUEST = 0xB019, ///< FP temperature override request + MSG_ID_FP_FILTERED_FLOW_RATE_OVERRIDE_REQUEST = 0xB01A, ///< FP override request for filtered flow rate (mL/min) + MSG_ID_FP_FILTERED_FLOW_TEMP_OVERRIDE_REQUEST = 0xB01B, ///< FP override request for filtered flow temperature (deg C) + MSG_ID_FP_PRE_GEN_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB01C, ///< FP pre generation data publish interval override request + MSG_ID_FP_SET_OPERATION_MODE_REQUEST = 0xB01D, ///< FP set operation mode request + MSG_ID_FP_OPERATION_MODE_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB01E, ///< FP operation mode publish interval override + MSG_ID_FP_TEMPERATURE_SENSOR_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB01F, ///< FP temperature sensor publish interval override + MSG_ID_FP_RO_PUMP_TARGET_PRESSURE_OVERRIDE_REQUEST = 0xB020, ///< FP RO Pump Target Pressure override request + MSG_ID_FP_RO_PUMP_TARGET_FLOW_OVERRIDE_REQUEST = 0xB021, ///< FP RO Pump Target Flow override request + MSG_ID_FP_RO_PUMP_TARGET_PWM_OVERRIDE_REQUEST = 0xB022, ///< FP RO Pump Target PWM override request + MSG_ID_FP_BOOST_PUMP_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB023, ///< FP Boost Pump Target data publish interval override request + MSG_ID_FP_BOOST_PUMP_TARGET_PRESSURE_OVERRIDE_REQUEST = 0xB024, ///< FP Boost Pump Target Pressure override request + MSG_ID_FP_BOOST_PUMP_TARGET_FLOW_OVERRIDE_REQUEST = 0xB025, ///< FP Boost Pump Target Flow override request + MSG_ID_FP_BOOST_PUMP_TARGET_PWM_OVERRIDE_REQUEST = 0xB026, ///< FP RO Pump Target PWM override request + MSG_ID_FP_BOOST_PUMP_STOP_REQUEST = 0xB027, ///< FP Boost Pump Stop request + MSG_ID_FP_RO_PUMP_STOP_REQUEST = 0xB028, ///< FP RO Pump Stop request + MSG_ID_FP_SAFETY_SHUTDOWN_OVERRIDE_REQUEST = 0xB029, ///< FP Safety Shutdown override request + MSG_ID_FP_PERMEATE_TANK_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB02A, ///< FP Permeate Tank data publish interval override request + MSG_ID_FP_ALARM_STATE_OVERRIDE_REQUEST = 0xB02B, ///< FP Alarm State override request + MSG_ID_FP_ALARM_CLEAR_ALL_ALARMS_REQUEST = 0xB02C, ///< FP alarm clear request + MSG_ID_FP_SET_TEST_CONFIGURATION = 0xB02D, ///< FP set test configuration + MSG_ID_FP_GET_TEST_CONFIGURATION = 0xB02E, ///< FP get test configuration + MSG_ID_FP_RESET_ALL_TEST_CONFIGURATIONS = 0xB02F, ///< FP reset all the configurations + MSG_ID_FP_INLET_PRES_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB030, ///< FP inlet pressure check data publish interval override request + MSG_ID_FP_INLET_PRES_CHECK_TIME_OVERRIDE_REQUEST = 0xB031, ///< FP inlet pressure check time override request + MSG_ID_FP_FILTERED_COND_SENSOR_READINGS_OVERRIDE_REQUEST = 0xB032, ///< FP filtered conductivity sensor reading override request + MSG_ID_FP_FILTERED_COND_SENSOR_TEMPERATURE_OVERRIDE_REQUEST = 0xB033, ///< FP filtered conductivity sensor temperature override request + MSG_ID_FP_SET_START_STOP_OVERRIDE_REQUEST = 0xB034, ///< FP set start stop signal for generate permeate + MSG_ID_FP_RO_REJECTION_RATIO_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB035, ///< FP RO rejection ratio data publish interval override request + MSG_ID_FP_RO_FILTERED_REJECTION_RATIO_OVERRIDE_REQUEST = 0xB036, ///< FP override request for filtered all time RO rejection value + MSG_ID_FP_RO_GET_CALCULATED_DUTY_CYCLE_REQUEST = 0xB037, ///< FP Request for calculated RO duty cycle + MSG_ID_FP_RO_CALCULATED_DUTY_CYCLE_RESPONSE = 0xB038, ///< DD send calculated duty cycle to Dialin + MSG_ID_FP_FLUSH_FILTER_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB039, ///< FP filter flush data publish interval override request + MSG_ID_FP_FLUSH_FILTER_TIMER_OVERRIDE_REQUEST = 0xB03A, ///< FP filter flush time override request + MSG_ID_FP_FLUSH_PERMEATE_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB03B, ///< FP permeate flush data publish interval override request + MSG_ID_FP_FLUSH_PERMEATE_TIMER_OVERRIDE_REQUEST = 0xB03C, ///< FP permeate flush timer override request + MSG_ID_FP_FLUSH_PERMEATE_ALARM_TIMER_OVERRIDE_REQUEST = 0xB03D, ///< FP permeate alarm timer override request + MSG_ID_FP_FLUSH_CONCENTRATE_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB03E, ///< FP flush concentrate data publish interval override request + MSG_ID_FP_FLUSH_CONCENTRATE_TIMER_OVERRIDE_REQUEST = 0xB03F, ///< FP flush concentrate timer override request + MSG_ID_FP_DEF_FLUSH_FILTER_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB040, ///< FP defeatured filter flush data publish interval override request + MSG_ID_FP_DEF_FLUSH_FILTER_TIMER_OVERRIDE_REQUEST = 0xB041, ///< FP defeatured filter flush time override request + MSG_ID_FP_DEF_PRE_GEN_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB042, ///< FP defeatured pre generation data publish interval override request + MSG_ID_FP_DEF_GEN_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB043, ///< FP defeatured generation data publish interval override request + MSG_ID_FP_DEF_STATUS_REQUEST = 0xB044, ///< FP request for defatured status from Dialin + MSG_ID_FP_DEF_STATUS_RESPONSE = 0xB045, ///< FP response for defatured status to Dialin + MSG_ID_FP_SET_OPERATION_SUB_MODE_REQUEST = 0xB046, ///< FP set operation sub mode request + MSG_ID_FP_CONDUCTIVITY_SENSOR_RESISTANCE_OVERRIDE_REQUEST = 0xB047, ///< FP conductivity sensor resistance override request + MSG_ID_FP_SET_RECOVERY_VALVES_REQUEST = 0xB048, ///< FP request to set recovery valve setting + MSG_ID_FP_BOOST_PUMP_INSTALL_STATUS_REQUEST = 0xB049, ///< FP request for boost pump installation status from Dialin + MSG_ID_FP_BOOST_PUMP_INSTALL_STATUS_RESPONSE = 0xB04A, ///< FP response for boost pump installation status to Dialin + MSG_ID_FP_CONDUCTIVITY_SENSOR_VERSION_REQUEST = 0xB04B, ///< FP conductivity sensor version request + MSG_ID_FP_CONDUCTIVITY_SENSOR_VERSION_RESPONSE = 0xB04C, ///< FP conductivity sensor version response - MSG_ID_FIRST_FP_TESTER_MESSAGE = 0xB000, ///< First FP test message ID - MSG_ID_FP_TESTER_LOGIN_REQUEST = MSG_ID_FIRST_FP_TESTER_MESSAGE, ///< FP tester log-in - MSG_ID_FP_SOFTWARE_RESET_REQUEST = 0xB001, ///< FP reset request - MSG_ID_FP_SEND_TEST_CONFIGURATION = 0xB002, ///< FP send test configuration to Dialin - MSG_ID_FP_VALVE_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB003, ///< FP valve data publish interval override request - MSG_ID_FP_VALVE_CMD_STATE_OVERRIDE_REQUEST = 0xB004, ///< FP valve commanded state override request - MSG_ID_FP_VALVE_SENSED_STATE_OVERRIDE_REQUEST = 0xB005, ///< FP valve sensed state override request - MSG_ID_FP_FLUID_PUMP_SET_PWM_REQUEST = 0xB006, ///< FP set boost pump PWM request - MSG_ID_FP_FLUID_PUMP_READ_PWM_OVERRIDE_REQUEST = 0xB007, ///< FP override request for boost pump read PWM - MSG_ID_FP_FLUID_PUMP_SPEED_OVERRIDE_REQUEST = 0xB008, ///< FP override request for boost pump speed (RPM) - MSG_ID_FP_RO_PUMP_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB009, ///< FP boost pumps data publish interval override request - MSG_ID_FP_PRESSURE_OVERRIDE_REQUEST = 0xB00A, ///< FP override request for pressure (mmHg) - MSG_ID_FP_PRESSURE_TEMP_OVERRIDE_REQUEST = 0xB00B, ///< FP override request for pressure sensor temperature (deg C) - MSG_ID_FP_PRESSURE_SENSOR_FILTER_READINGS_OVERRIDE_REQUEST = 0xB00C, ///< FP pressure sensor filter readings override request - MSG_ID_FP_PRESSURE_SENSOR_FILTER_TEMPERATURE_OVERRIDE_REQUEST = 0xB00D, ///< FP pressure sensor filter temperature override request - MSG_ID_FP_PRESSURE_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB00E, ///< FP pressures data publish interval override request - MSG_ID_FP_LEVEL_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB00F, ///< FP level data publish interval override request - MSG_ID_FP_LEVEL_OVERRIDE_REQUEST = 0xB010, ///< FP override request for level sensor. - MSG_ID_FP_FLOWS_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB011, ///< FP flows data publish interval override request - MSG_ID_FP_FLOW_RATE_OVERRIDE_REQUEST = 0xB012, ///< FP override request for flow rate (mL/min) - MSG_ID_FP_FLOW_TEMP_OVERRIDE_REQUEST = 0xB013, ///< FP override request for flow temperature (deg C) - MSG_ID_FP_CONDUCTIVITY_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB014, ///< FP conductivity data publish interval override request - MSG_ID_FP_CONDUCTIVITY_OVERRIDE_REQUEST = 0xB015, ///< FP conductivity override request - MSG_ID_FP_CONDUCTIVITY_TEMP_OVERRIDE_REQUEST = 0xB016, ///< FP conductivity sensor temperature override request - MSG_ID_FP_CONDUCTIVITY_READ_COUNT_OVERRIDE_REQUEST = 0xB017, ///< FP conductivity sensor read count override request - MSG_ID_FP_CONDUCTIVITY_ERROR_COUNT_OVERRIDE_REQUEST = 0xB018, ///< FP conductivity sensor error count override request - MSG_ID_FP_TEMPERATURE_OVERRIDE_REQUEST = 0xB019, ///< FP temperature override request - MSG_ID_FP_FILTERED_FLOW_RATE_OVERRIDE_REQUEST = 0xB01A, ///< FP override request for filtered flow rate (mL/min) - MSG_ID_FP_FILTERED_FLOW_TEMP_OVERRIDE_REQUEST = 0xB01B, ///< FP override request for filtered flow temperature (deg C) - MSG_ID_FP_PRE_GEN_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB01C, ///< FP pre generation data publish interval override request - MSG_ID_FP_SET_OPERATION_MODE_REQUEST = 0xB01D, ///< FP set operation mode request - MSG_ID_FP_OPERATION_MODE_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB01E, ///< FP operation mode publish interval override - MSG_ID_FP_TEMPERATURE_SENSOR_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB01F, ///< FP temperature sensor publish interval override - MSG_ID_FP_RO_PUMP_TARGET_PRESSURE_OVERRIDE_REQUEST = 0xB020, ///< FP RO Pump Target Pressure override request - MSG_ID_FP_RO_PUMP_TARGET_FLOW_OVERRIDE_REQUEST = 0xB021, ///< FP RO Pump Target Flow override request - MSG_ID_FP_RO_PUMP_TARGET_PWM_OVERRIDE_REQUEST = 0xB022, ///< FP RO Pump Target PWM override request - MSG_ID_FP_BOOST_PUMP_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB023, ///< FP Boost Pump Target data publish interval override request - MSG_ID_FP_BOOST_PUMP_TARGET_PRESSURE_OVERRIDE_REQUEST = 0xB024, ///< FP Boost Pump Target Pressure override request - MSG_ID_FP_BOOST_PUMP_TARGET_FLOW_OVERRIDE_REQUEST = 0xB025, ///< FP Boost Pump Target Flow override request - MSG_ID_FP_BOOST_PUMP_TARGET_PWM_OVERRIDE_REQUEST = 0xB026, ///< FP RO Pump Target PWM override request - MSG_ID_FP_BOOST_PUMP_STOP_REQUEST = 0xB027, ///< FP Boost Pump Stop request - MSG_ID_FP_RO_PUMP_STOP_REQUEST = 0xB028, ///< FP RO Pump Stop request - MSG_ID_FP_SAFETY_SHUTDOWN_OVERRIDE_REQUEST = 0xB029, ///< FP Safety Shutdown override request - MSG_ID_FP_PERMEATE_TANK_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB02A, ///< FP Permeate Tank data publish interval override request - MSG_ID_FP_ALARM_STATE_OVERRIDE_REQUEST = 0xB02B, ///< FP Alarm State override request - MSG_ID_FP_ALARM_CLEAR_ALL_ALARMS_REQUEST = 0xB02C, ///< FP alarm clear request - MSG_ID_FP_SET_TEST_CONFIGURATION = 0xB02D, ///< FP set test configuration - MSG_ID_FP_GET_TEST_CONFIGURATION = 0xB02E, ///< FP get test configuration - MSG_ID_FP_RESET_ALL_TEST_CONFIGURATIONS = 0xB02F, ///< FP reset all the configurations - MSG_ID_FP_INLET_PRES_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB030, ///< FP inlet pressure check data publish interval override request - MSG_ID_FP_INLET_PRES_CHECK_TIME_OVERRIDE_REQUEST = 0xB031, ///< FP inlet pressure check time override request - MSG_ID_FP_FILTERED_COND_SENSOR_READINGS_OVERRIDE_REQUEST = 0xB032, ///< FP filtered conductivity sensor reading override request - MSG_ID_FP_FILTERED_COND_SENSOR_TEMPERATURE_OVERRIDE_REQUEST = 0xB033, ///< FP filtered conductivity sensor temperature override request - MSG_ID_FP_SET_START_STOP_OVERRIDE_REQUEST = 0xB034, ///< FP set start stop signal for generate permeate - MSG_ID_FP_RO_REJECTION_RATIO_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB035, ///< FP RO rejection ratio data publish interval override request - MSG_ID_FP_RO_FILTERED_REJECTION_RATIO_OVERRIDE_REQUEST = 0xB036, ///< FP override request for filtered all time RO rejection value - MSG_ID_FP_RO_GET_CALCULATED_DUTY_CYCLE_REQUEST = 0xB037, ///< FP Request for calculated RO duty cycle - MSG_ID_FP_RO_CALCULATED_DUTY_CYCLE_RESPONSE = 0xB038, ///< DD send calculated duty cycle to Dialin - MSG_ID_FP_FLUSH_FILTER_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB039, ///< FP filter flush data publish interval override request - MSG_ID_FP_FLUSH_FILTER_TIMER_OVERRIDE_REQUEST = 0xB03A, ///< FP filter flush time override request - MSG_ID_FP_FLUSH_PERMEATE_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB03B, ///< FP permeate flush data publish interval override request - MSG_ID_FP_FLUSH_PERMEATE_TIMER_OVERRIDE_REQUEST = 0xB03C, ///< FP permeate flush timer override request - MSG_ID_FP_FLUSH_PERMEATE_ALARM_TIMER_OVERRIDE_REQUEST = 0xB03D, ///< FP permeate alarm timer override request - MSG_ID_FP_FLUSH_CONCENTRATE_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB03E, ///< FP flush concentrate data publish interval override request - MSG_ID_FP_FLUSH_CONCENTRATE_TIMER_OVERRIDE_REQUEST = 0xB03F, ///< FP flush concentrate timer override request - MSG_ID_FP_DEF_FLUSH_FILTER_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB040, ///< FP defeatured filter flush data publish interval override request - MSG_ID_FP_DEF_FLUSH_FILTER_TIMER_OVERRIDE_REQUEST = 0xB041, ///< FP defeatured filter flush time override request - MSG_ID_FP_DEF_PRE_GEN_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB042, ///< FP defeatured pre generation data publish interval override request - MSG_ID_FP_DEF_GEN_PUBLISH_INTERVAL_OVERRIDE_REQUEST = 0xB043, ///< FP defeatured generation data publish interval override request - MSG_ID_FP_DEF_STATUS_REQUEST = 0xB044, ///< FP request for defatured status from Dialin - MSG_ID_FP_DEF_STATUS_RESPONSE = 0xB045, ///< FP response for defatured status to Dialin - MSG_ID_FP_SET_OPERATION_SUB_MODE_REQUEST = 0xB046, ///< FP set operation sub mode request - MSG_ID_FP_BOOST_PUMP_INSTALL_STATUS_REQUEST = 0xB049, ///< FP request for boost pump installation status from Dialin - MSG_ID_FP_BOOST_PUMP_INSTALL_STATUS_RESPONSE = 0xB04A, ///< FP response for boost pump installation status to Dialin -#ifdef __TEENSY_CONDUCTIVITY_DRIVER__ - MSG_ID_FP_CONDUCTIVITY_SENSOR_RESISTANCE_OVERRIDE_REQUEST = 0xB100, ///< FP conductivity sensor resistance override request -#endif - MSG_ID_TD_DEBUG_EVENT = 0xFFF1, ///< TD debug event text to be logged in event log MSG_ID_DD_DEBUG_EVENT = 0xFFF2, ///< DD debug event text to be logged in event log MSG_ID_FP_DEBUG_EVENT = 0xFFF3, ///< FP debug event text to be logged in event log Index: TDDefs.h =================================================================== diff -u -r413aa187b32921babc077451fb7c98578707497b -r8f4c7a14f0ed74c238c7c72a316a026e50dc3cec --- TDDefs.h (.../TDDefs.h) (revision 413aa187b32921babc077451fb7c98578707497b) +++ TDDefs.h (.../TDDefs.h) (revision 8f4c7a14f0ed74c238c7c72a316a026e50dc3cec) @@ -206,24 +206,26 @@ /// Enumeration of dry self-tests sub-mode states. enum TD_Pre_Treatment_Dry_Self_Tests_States { - DRY_SELF_TESTS_START_STATE = 0, ///< Dry self-tests starting state - DRY_SELF_TESTS_WAIT_FOR_DOOR_CLOSE_STATE, ///< Wait for door to close before executing self-tests - DRY_SELF_TESTS_USED_CARTRIDGE_CHECK_STATE, ///< Used cartridge check dry self-test state - DRY_SELF_TESTS_CARTRIDGE_LOADED_CHECK_STATE, ///< Cartridge loaded check dry self-test state - DRY_SELF_TESTS_SYRINGE_PUMP_SEEK_STATE, ///< Seek syringe pumps state - DRY_SELF_TESTS_PRESSURE_SENSORS_NORMAL_SETUP_STATE, ///< Pressure sensor setup state - DRY_SELF_TESTS_PRESSURE_SENSORS_VENOUS_SETUP_STATE, ///< Venous pressure sensor dry self-test setup valves and pump state - DRY_SELF_TESTS_PRESSURE_SENSORS_VENOUS, ///< Venous pressure sensor dry self-test - DRY_SELF_TESTS_PRESSURE_SENSORS_ARTERIAL_SETUP_STATE, ///< Arterial pressure sensor dry self-test setup valves and pump state - DRY_SELF_TESTS_PRESSURE_SENSORS_ARTERIAL, ///< Arterial pressure sensor dry self-test - DRY_SELF_TESTS_PRESSURE_SENSORS_DECAY_STATE, ///< Pressure sensors verify pressure loss state - DRY_SELF_TESTS_PRESSURE_SENSORS_STABILITY_STATE, ///< Pressure sensors verify pressure stability state - DRY_SELF_TESTS_PRESSURE_SENSORS_NORMAL_STATE, ///< Pressure sensors verify normal pressure readings state - DRY_SELF_TESTS_SYRINGE_PUMP_PRIME_STATE, ///< Prime syringe pump state - DRY_SELF_TESTS_SYRINGE_PUMP_OCCLUSION_DETECTION_STATE, ///< Occlusion detection state - DRY_SELF_TESTS_STOPPED_STATE, ///< Dry self-test stopped state - DRY_SELF_TESTS_COMPLETE_STATE, ///< Dry self-test complete state - NUM_OF_DRY_SELF_TESTS_STATES ///< Number of dry self-tests states + DRY_SELF_TESTS_START_STATE = 0, ///< Dry self-tests start state + DRY_SELF_TESTS_WAIT_FOR_DOOR_CLOSE_STATE, ///< Wait for door close state + DRY_SELF_TESTS_USED_CARTRIDGE_CHECK_STATE, ///< Used cartridge check state + DRY_SELF_TESTS_CARTRIDGE_LOADED_CHECK_STATE, ///< Cartridge loaded check state + DRY_SELF_TESTS_TUBE_SET_AUTHENTICATION_STATE, ///< Tube set authentication state + DRY_SELF_TESTS_SYRINGE_PUMP_SEEK_STATE, ///< Syringe pump seek state + DRY_SELF_TESTS_PRESSURE_SENSOR_NORMAL_SETUP_STATE, ///< Pressure sensor normal setup state + DRY_SELF_TESTS_PRESSURE_VENOUS_SETUP_STATE, ///< Pressure venous setup state + DRY_SELF_TESTS_VENOUS_PRESSURE_STABILIZATION_STATE, ///< Venous pressure stabilization state + DRY_SELF_TESTS_VENOUS_PRESSURE_LEAK_CHECK_STATE, ///< Venous pressure leak check state + DRY_SELF_TESTS_VENOUS_PRESSURE_RELIEF_STATE, ///< Venous pressure relief state + DRY_SELF_TESTS_PRESSURE_ARTERIAL_SETUP_STATE, ///< Pressure arterial setup state + DRY_SELF_TESTS_ARTERIAL_PRESSURE_STABILIZATION_STATE, ///< Arterial pressure stabilization state + DRY_SELF_TESTS_ARTERIAL_PRESSURE_LEAK_CHECK_STATE, ///< Arterial pressure leak check state + DRY_SELF_TESTS_ARTERIAL_PRESSURE_RELIEF_STATE, ///< Arterial pressure relief state + DRY_SELF_TESTS_SYRINGE_PUMP_PRIME_STATE, ///< Syringe prime state + DRY_SELF_TESTS_SYRINGE_PUMP_OCCLUSION_CHECK_STATE, ///< Syringe pump occlusion check state + DRY_SELF_TESTS_COMPLETE_STATE, ///< Complete state + DRY_SELF_TESTS_STOPPED_STATE, ///< Stopped state + NUM_OF_DRY_SELF_TESTS_STATES ///< Number of dry self-tests states }; /// Type for dry self-tests enumeration. typedef enum TD_Pre_Treatment_Dry_Self_Tests_States DRY_SELF_TESTS_STATE_T; @@ -719,6 +721,8 @@ TD_EVENT_OP_MODE_CHANGE, ///< TD Op mode change event TD_EVENT_SUB_MODE_CHANGE, ///< TD Op sub-mode change event TD_EVENT_DRY_SELF_TEST_CARTRIDGE_RESULT, ///< TD dry self test cartridge result + TD_EVENT_TUBING_SET_BARCODE_SCAN_REQUEST, ///< TD tubing set barcode scan request + TD_EVENT_TUBING_SET_BARCODE_SCAN_AUTHENTICATED, ///< TD tubing set barcode scan authenticated TD_EVENT_DRY_SELF_TEST_PRESSURE_RESULT, ///< TD dry self test pressure result TD_EVENT_WET_SELF_TEST_DISPLACEMENT_RESULT, ///< TD wet self test displacement result TD_EVENT_CPU_RAM_ERROR_STATUS, ///< TD CPU RAM error status @@ -735,7 +739,6 @@ TD_EVENT_AIR_TRAP_FILL, ///< TD started/stopped an air trap fill operation. TD_EVENT_AIR_TRAP_LOWER, ///< TD started/stopped an air trap lower level operation. TD_EVENT_AIR_PUMP_ON_OFF, ///< TD turned air pump on/off. - TD_EVENT_DRY_SELF_TEST_PRESSURE_DECAY_WAIT_PERIOD, ///< TD dry self test pressure decay waiting period. TD_EVENT_INSTIT_RECORD_UPDATE, ///< TD new institutional record has been updated. TD_EVENT_VALVE_POS_CHANGE, ///< TD pinch valve position change TD_EVENT_VALVE_HOMED_POS_SETTING, ///< TD pinch valve homed encoder positions for A/B/C.