Index: AlarmDefs.h =================================================================== diff -u -r0a08bfab79f4b4f3438902008a239f10ac4963a9 -rd18cd031dcff2fc807ce158cbb4aadfda10fd3cd --- AlarmDefs.h (.../AlarmDefs.h) (revision 0a08bfab79f4b4f3438902008a239f10ac4963a9) +++ AlarmDefs.h (.../AlarmDefs.h) (revision d18cd031dcff2fc807ce158cbb4aadfda10fd3cd) @@ -216,10 +216,11 @@ ALARM_ID_TD_SYRINGE_PUMP_PRIME_TIMEOUT = 184, ///< TD syringe pump prime timeout ALARM_ID_FP_P9_COND_SENSOR_FPGA_FAULT = 185, ///< FP P9 conductivity sensor fpga fault ALARM_ID_FP_P18_COND_SENSOR_FPGA_FAULT = 186, ///< FP P18 conductivity sensor fpga fault - ALARM_ID_TD_AUTO_LOAD_EJECT_BP_TIMEOUT = 187, ///< TD blood pump timeout during auto-load\eject operation - ALARM_ID_TD_AUTO_EJECT_EJECTOR_TIMEOUT = 188, ///< TD ejector failed to extend or retract during auto-eject operation - ALARM_ID_TD_EJECTOR_POST_TEST_FAILED = 189, ///< TD ejector POST homing failure - ALARM_ID_TD_AUTO_LOAD_EJECT_HIGH_BP_TORQUE = 190, ///< TD high blood pump torque during auto-load\eject operation + ALARM_ID_TD_AIR_PUMP_STALL = 187, ///< TD air pump stall detected + ALARM_ID_TD_AUTO_LOAD_EJECT_BP_TIMEOUT = 188, ///< TD blood pump timeout during auto-load\eject operation + ALARM_ID_TD_AUTO_EJECT_EJECTOR_TIMEOUT = 189, ///< TD ejector failed to extend or retract during auto-eject operation + ALARM_ID_TD_EJECTOR_POST_TEST_FAILED = 190, ///< TD ejector POST homing failure + ALARM_ID_TD_AUTO_LOAD_EJECT_HIGH_BP_TORQUE = 191, ///< TD high blood pump torque during auto-load\eject operation NUM_OF_ALARM_IDS ///< Number of alarms }; typedef enum Alarm_List ALARM_ID_T; ///< Type for alarm list enumeration @@ -554,6 +555,7 @@ { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_SYRINGE_PUMP_PRIME_TIMEOUT }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_P9_COND_SENSOR_FPGA_FAULT }, { ALARM_PRIORITY_HIGH, 110, ALM_SRC_FP, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_FP_P18_COND_SENSOR_FPGA_FAULT }, + { ALARM_PRIORITY_HIGH, 206, ALM_SRC_TD, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , ALARM_ID_TD_AIR_PUMP_STALL }, { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_AUTO_LOAD_EJECT_BP_TIMEOUT }, { ALARM_PRIORITY_HIGH, 10, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_AUTO_EJECT_EJECTOR_TIMEOUT }, { ALARM_PRIORITY_HIGH, 1, ALM_SRC_TD, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_TD_EJECTOR_POST_TEST_FAILED }, @@ -710,6 +712,7 @@ { 203, ALARM_ID_TD_ARTERIAL_PRESSURE_HIGH }, { 204, ALARM_ID_TD_TMP_PRESSURE_LOW }, { 205, ALARM_ID_TD_TMP_PRESSURE_HIGH }, + { 206, ALARM_ID_TD_AIR_PUMP_STALL }, { 207, ALARM_ID_TD_SYRINGE_PUMP_SYRINGE_REMOVED }, { 210, ALARM_ID_TD_CARTRIDGE_DOOR_OPENED }, { 290, ALARM_ID_TD_BLOOD_SITTING_WARNING }, @@ -970,10 +973,11 @@ { 184 , ALARM_ID_TD_SYRINGE_PUMP_PRIME_TIMEOUT , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | TD Fault: Pre- Tx Hep. Pump Timeout. | TD syringe pump timeout alarm | If the syringe pump priming > 5 seconds | "}, { 185 , ALARM_ID_FP_P9_COND_SENSOR_FPGA_FAULT , "FP | Service Required: FP Device | A problem was detected with the FP device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Conductivity Sensor Error | FP conductivity sensor (P9) located in inlet water path reporting error or not being read successfully | Conductvity Sensor (P9) is reporting an error or FPGA is failing to read sensor. | "}, { 186 , ALARM_ID_FP_P18_COND_SENSOR_FPGA_FAULT , "FP | Service Required: FP Device | A problem was detected with the FP device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | FP Conductivity Sensor Error | FP conductivity sensor (P18) located in inlet water path reporting error or not being read successfully | Conductvity Sensor (P18) is reporting an error or FPGA is failing to read sensor. | "}, - { 187 , ALARM_ID_TD_AUTO_LOAD_EJECT_BP_TIMEOUT , "TD | Service Required: Hemodialysis Device | The blood pump did not complete the required operation within the allowed time.\n- The blood pump rotor may be obstructed, or the Hall sensor may be faulty.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call Service to report the issue and schedule a repair. | TD Fault: BP Operation Timeout | Blood pump failed to complete homing or one full revolution during auto-load or auto-eject | If the blood pump fails to reach the home position or complete one full revolution within the allowed time during an auto-loading, or auto-eject homing, or auto-eject ejection operation. | "}, - { 188 , ALARM_ID_TD_AUTO_EJECT_EJECTOR_TIMEOUT , "TD | Service Required: Hemodialysis Device | The ejector did not reach the expected position within the allowed time.\n- The ejector motor may be faulty or optical sensors may be obstructed or faulty.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call Service to report the issue and schedule a repair. | TD Fault: Ejector Timeout | Ejector failed to reach extended or retracted position during auto-eject | If the ejector does not reach the fully extended or fully retracted position within the allowed time during the auto-eject sequence. | "}, - { 189 , ALARM_ID_TD_EJECTOR_POST_TEST_FAILED , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call Service to report the issue and schedule a repair. | TD POST: Ejector Homing | TD ejector did not reach the fully retracted position within the allowed time during power-on self-test | If the ejector does not reach the fully retracted position within allowed time during the power-on self-test. | "}, - { 190 , ALARM_ID_TD_AUTO_LOAD_EJECT_HIGH_BP_TORQUE , "TD | Blood Pump Stopped: Tubing Set Jam | A problem was detected during tube set load/eject.\n- The blood pump is reversing to the home position.\n- Once the pump has returned to home, re-seat the blood tubing set and press Resume to retry loading, or wait for the pump to return to home and retry ejecting.\n- If the problem persists, press End Treatment. | Blood Stop: High BP Torque | Blood pump torque exceeded limit during Auto-Load/Eject one-revolution and tubing set jam suspected | If the measured blood pump torque exceeds TBD mNm during the Auto-Load or Auto-Eject one-revolution forward rotation. | "}, + { 187 , ALARM_ID_TD_AIR_PUMP_STALL , "TD | Air Pump Stall Detected | The air pump is commanded to run but no rotation is detected.\n- Check tubing for blockage or occlusion.\n- Verify pump operation and connections.\n- If issue persists, terminate treatment and inspect system. | Blood Pump: Air Pump Stall | Air pump stall detected during treatment | If the air pump is commanded on and the measured RPM is zero for multiple controller cycles. | "}, + { 188 , ALARM_ID_TD_AUTO_LOAD_EJECT_BP_TIMEOUT , "TD | Service Required: Hemodialysis Device | The blood pump did not complete the required operation within the allowed time.\n- The blood pump rotor may be obstructed, or the Hall sensor may be faulty.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call Service to report the issue and schedule a repair. | TD Fault: BP Operation Timeout | Blood pump failed to complete homing or one full revolution during auto-load or auto-eject | If the blood pump fails to reach the home position or complete one full revolution within the allowed time during an auto-loading, or auto-eject homing, or auto-eject ejection operation. | "}, + { 189 , ALARM_ID_TD_AUTO_EJECT_EJECTOR_TIMEOUT , "TD | Service Required: Hemodialysis Device | The ejector did not reach the expected position within the allowed time.\n- The ejector motor may be faulty or optical sensors may be obstructed or faulty.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call Service to report the issue and schedule a repair. | TD Fault: Ejector Timeout | Ejector failed to reach extended or retracted position during auto-eject | If the ejector does not reach the fully extended or fully retracted position within the allowed time during the auto-eject sequence. | "}, + { 190 , ALARM_ID_TD_EJECTOR_POST_TEST_FAILED , "TD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call Service to report the issue and schedule a repair. | TD POST: Ejector Homing | TD ejector did not reach the fully retracted position within the allowed time during power-on self-test | If the ejector does not reach the fully retracted position within allowed time during the power-on self-test. | "}, + { 191 , ALARM_ID_TD_AUTO_LOAD_EJECT_HIGH_BP_TORQUE , "TD | Blood Pump Stopped: Tubing Set Jam | A problem was detected during tube set load/eject.\n- The blood pump is reversing to the home position.\n- Once the pump has returned to home, re-seat the blood tubing set and press Resume to retry loading, or wait for the pump to return to home and retry ejecting.\n- If the problem persists, press End Treatment. | Blood Stop: High BP Torque | Blood pump torque exceeded limit during Auto-Load/Eject one-revolution and tubing set jam suspected | If the measured blood pump torque exceeds TBD mNm during the Auto-Load or Auto-Eject one-revolution forward rotation. | "}, }; #endif // manual alarms Index: MsgDefs.h =================================================================== diff -u -r0a08bfab79f4b4f3438902008a239f10ac4963a9 -rd18cd031dcff2fc807ce158cbb4aadfda10fd3cd --- MsgDefs.h (.../MsgDefs.h) (revision 0a08bfab79f4b4f3438902008a239f10ac4963a9) +++ MsgDefs.h (.../MsgDefs.h) (revision d18cd031dcff2fc807ce158cbb4aadfda10fd3cd) @@ -406,7 +406,9 @@ MSG_ID_DD_DIALYSATE_DELTA_CONDUCTIVITY_OVERRIDE_REQUEST = 0xA069, ///< DD Dialysate delta target conductivity override MSG_ID_DD_BICART_UPPER_PRESSURE_OVERRIDE_REQUEST = 0xA06A, ///< DD bicarb cartridge upper threshold pressure override MSG_ID_DD_BICART_LOWER_PRESSURE_OVERRIDE_REQUEST = 0xA06B, ///< DD bicarb cartridge lower threshold pressure override - MSG_ID_DD_FLOATER_LEVEL_OVERRIDE_REQUEST = 0xA06C, ///< DD override request for D6 floater level override + MSG_ID_DD_FLOATER_LEVEL_OVERRIDE_REQUEST = 0xA06C, ///< DD floater level override request + MSG_ID_DD_SUBSTITUTION_PUMP_START_STOP_OVERRIDE_REQUEST = 0xA06D, ///< DD substitution pump start stop override request + MSG_ID_DD_SUBSTITUTION_PUMP_BROADCAST_OVERRIDE_REQUEST = 0xA06E, ///< DD substitution pump broadcast override request MSG_ID_FIRST_FP_TESTER_MESSAGE = 0xB000, ///< First FP test message ID MSG_ID_FP_TESTER_LOGIN_REQUEST = MSG_ID_FIRST_FP_TESTER_MESSAGE, ///< FP tester log-in @@ -481,13 +483,12 @@ MSG_ID_FP_DEF_STATUS_RESPONSE = 0xB045, ///< FP response for defatured status to Dialin MSG_ID_FP_SET_OPERATION_SUB_MODE_REQUEST = 0xB046, ///< FP set operation sub mode request MSG_ID_FP_CONDUCTIVITY_SENSOR_RESISTANCE_OVERRIDE_REQUEST = 0xB047, ///< FP conductivity sensor resistance override request - MSG_ID_FP_SET_RECOVERY_VALVES_REQUEST = 0xB048, ///< FP request to set recovery valve setting + MSG_ID_FP_SET_RECOVERY_VALVES_REQUEST = 0xB048, ///< FP request to set recovery valve setting. MSG_ID_FP_BOOST_PUMP_INSTALL_STATUS_REQUEST = 0xB049, ///< FP request for boost pump installation status from Dialin MSG_ID_FP_BOOST_PUMP_INSTALL_STATUS_RESPONSE = 0xB04A, ///< FP response for boost pump installation status to Dialin MSG_ID_FP_CONDUCTIVITY_SENSOR_VERSION_REQUEST = 0xB04B, ///< FP conductivity sensor version request MSG_ID_FP_CONDUCTIVITY_SENSOR_VERSION_RESPONSE = 0xB04C, ///< FP conductivity sensor version response - MSG_ID_TD_DEBUG_EVENT = 0xFFF1, ///< TD debug event text to be logged in event log MSG_ID_DD_DEBUG_EVENT = 0xFFF2, ///< DD debug event text to be logged in event log MSG_ID_FP_DEBUG_EVENT = 0xFFF3, ///< FP debug event text to be logged in event log Index: TDDefs.h =================================================================== diff -u -r0a08bfab79f4b4f3438902008a239f10ac4963a9 -rd18cd031dcff2fc807ce158cbb4aadfda10fd3cd --- TDDefs.h (.../TDDefs.h) (revision 0a08bfab79f4b4f3438902008a239f10ac4963a9) +++ TDDefs.h (.../TDDefs.h) (revision d18cd031dcff2fc807ce158cbb4aadfda10fd3cd) @@ -487,8 +487,8 @@ enum Blood_Prime_States { BLOOD_PRIME_RAMP_STATE = 0, ///< Ramp state of the blood prime sub-mode state machine - BLOOD_PRIME_RUN_STATE, ///< Run state of the blood prime sub-mode state machine - BLOOD_PRIME_PAUSED_STATE, ///< Paused state of the blood prime sub-mode state machine + BLOOD_PRIME_RUN_STATE = 1, ///< Run state of the blood prime sub-mode state machine + BLOOD_PRIME_PAUSED_STATE = 2, ///< Paused state of the blood prime sub-mode state machine NUM_OF_BLOOD_PRIME_STATES ///< Number of blood prime sub-mode states }; /// Type for treatment end states enumeration.