Index: leahi_dialin/common/alarm_defs.py =================================================================== diff -u -re9dfb2412b14f3d28824cb3e37c364b8194bb24e -r26cc08213fa34b2b2ec781dfb0768d8df1575abf --- leahi_dialin/common/alarm_defs.py (.../alarm_defs.py) (revision e9dfb2412b14f3d28824cb3e37c364b8194bb24e) +++ leahi_dialin/common/alarm_defs.py (.../alarm_defs.py) (revision 26cc08213fa34b2b2ec781dfb0768d8df1575abf) @@ -8,7 +8,7 @@ # @file alarm_defs.py # # @author (last) Enum Updater Script -# @date (last) 11-Aug-2026 +# @date (last) 19-Aug-2026 # @author (original) Zoltan Miskolci # @date (original) 31-Jul-2026 # @@ -219,30 +219,30 @@ ALARM_ID_DD_CPU_RAM_ERROR = 193 # DD CPU RAM error ALARM_ID_TD_INTEGRITY_POST_TEST_FAILED = 194 # TD integrity post test fault ALARM_ID_DD_INTEGRITY_POST_TEST_FAILED = 195 # TD integrity post test fault - ALARM_ID_TD_EMPTY_SALINE_BAG = 196 # TD empty saline bag alarm + ALARM_ID_TD_SALINE_BAG_VOLUME_LOW_ALARM = 196 # TD saline bag volume low alarm ALARM_ID_DD_D92_PUMP_RPM_OUT_OF_RANGE = 197 # DD D92 pump rpm out of range ALARM_ID_TD_PRIME_COMPLETED_MEDIUM = 198 # TD prime completed medium priority alarm ALARM_ID_TD_REPEATED_AIR_TRAP_LOWER_EVENTS = 199 # TD repeated air trap lower events ALARM_ID_TD_TUBE_SET_MISMATCH = 200 # TD tubeset mismatch alarm - ALARM_ID_RESERVED_201 = 201 # Reserved for ALARM_ID_DD_ACID_CONCENTRATE_CONDUCTIVITY_HIGH - ALARM_ID_RESERVED_202 = 202 # Reserved for ALARM_ID_DD_BICARBONATE_CONDUCTIVITY_LOW - ALARM_ID_RESERVED_203 = 203 # Reserved for ALARM_ID_DD_BICARBONATE_CONDUCTIVITY_HIGH - ALARM_ID_RESERVED_204 = 204 # Reserved for ALARM_ID_TD_SAFETY_SHUTDOWN_POST_TEST_FAILED - ALARM_ID_RESERVED_205 = 205 # Reserved for ALARM_ID_TD_UI_POST_TIMEOUT - ALARM_ID_RESERVED_206 = 206 # Reserved for ALARM_ID_TD_UI_COMPATIBILITY_ERROR - ALARM_ID_RESERVED_207 = 207 # Reserved for ALARM_ID_TD_BATTERY_PACK_ERROR_DETECTED - ALARM_ID_RESERVED_208 = 208 # Reserved for ALARM_ID_TD_BATTERY_COMM_FAULT - ALARM_ID_RESERVED_209 = 209 # Reserved for ALARM_ID_TD_BATTERY_CHARGER_ERROR_DETECTED - ALARM_ID_RESERVED_210 = 210 # Reserved for ALARM_ID_DD_TURN_OFF_INLET_WATER_VALVES - ALARM_ID_RESERVED_211 = 211 # Reserved for ALARM_ID_DD_CHEM_DISINFECT_FLUSH_FLUSH_SAMPLE - ALARM_ID_RESERVED_212 = 212 # Reserved for ALARM_ID_DD_RO_PERMEATE_SAMPLE_REMOVE_DIA_CAP - ALARM_ID_RESERVED_213 = 213 # Reserved for ALARM_ID_TD_BP_SYSTOLIC_LOW - ALARM_ID_RESERVED_214 = 214 # Reserved for ALARM_ID_TD_BP_SYSTOLIC_LOW_TOO_MANY - ALARM_ID_RESERVED_215 = 215 # Reserved for ALARM_ID_TD_BP_SYSTOLIC_HIGH - ALARM_ID_RESERVED_216 = 216 # Reserved for ALARM_ID_TD_BP_HEART_RATE_LOW - ALARM_ID_RESERVED_217 = 217 # Reserved for ALARM_ID_TD_BP_HEART_RATE_HIGH - ALARM_ID_RESERVED_218 = 218 # Reserved for ALARM_ID_TD_BP_MODULE_ERROR - ALARM_ID_RESERVED_219 = 219 # Reserved for ALARM_ID_TD_UI_POST_TEST_FAILED + ALARM_ID_TD_PRE_TX_HEPARIN_LOAD_SYRINGE = 201 # TD Pre-Treatment Load Heparin Syringe + ALARM_ID_FW_RESERVED_202 = 202 # FW reserved for use + ALARM_ID_FW_RESERVED_203 = 203 # FW reserved for use + ALARM_ID_FW_RESERVED_204 = 204 # FW reserved for use + ALARM_ID_TD_UI_POST_TIMEOUT = 205 # TD UI POST failed + ALARM_ID_TD_UI_COMPATIBILITY_ERROR = 206 # TD and UI software builds are not compatible + ALARM_ID_TD_SAFETY_SHUTDOWN_POST_TEST_FAILED = 207 # TD POST Safety Shutdown failure + ALARM_ID_FW_RESERVED_208 = 208 # FW reserved for use + ALARM_ID_FW_RESERVED_209 = 209 # FW reserved for use + ALARM_ID_FW_RESERVED_210 = 210 # FW reserved for use + ALARM_ID_FW_RESERVED_211 = 211 # FW reserved for use + ALARM_ID_FW_RESERVED_212 = 212 # FW reserved for use + ALARM_ID_TD_BP_SYSTOLIC_LOW = 213 # TD blood pressure systolic low + ALARM_ID_TD_BP_SYSTOLIC_LOW_TOO_MANY = 214 # TD blood pressure systolic high + ALARM_ID_TD_BP_SYSTOLIC_HIGH = 215 # TD blood pressure systolic high + ALARM_ID_TD_BP_HEART_RATE_LOW = 216 # TD blood pressure heart rate low + ALARM_ID_TD_BP_HEART_RATE_HIGH = 217 # TD blood pressure heart rate high + ALARM_ID_TD_BP_MODULE_ERROR = 218 # TD blood pressure module error + ALARM_ID_FW_RESERVED_219 = 219 # FW reserved for use ALARM_ID_DD_NVM_INVALID_SYSTEM_RECORD_CRC = 220 # DD invalid NVM System record ALARM_ID_DD_NVM_INVALID_SERVICE_RECORD_CRC = 221 # DD invalid NVM Service record ALARM_ID_DD_NVM_INVALID_CALIBRATION_RECORD_CRC = 222 # DD invalid NVM calibration record @@ -258,12 +258,12 @@ ALARM_ID_DD_NVM_INVALID_CAL_BICARB_CONCENTRATE = 232 # DD invalid bicarbonate concentrate calibration record ALARM_ID_DD_NVM_INVALID_CAL_ACCEL_SENSOR = 233 # DD invalid accelerometer sensor calibration record ALARM_ID_DD_NVM_INVALID_CAL_BLOOD_LEAK_SENSOR = 234 # DD invalid blood leak sensor calibration record - ALARM_ID_DD_NVM_INVALID_CAL_CONDUCTIVITY_SENSOR = 235 # DD invalid conductivity sensor calibration record - ALARM_ID_DD_NVM_INVALID_INSTIT_BASIC_RECORD_CRC = 236 # DD invalid basic institutional record - ALARM_ID_DD_NVM_INVALID_INSTIT_ADVANCED_RECORD_CRC = 237 # DD invalid advanced institutional record - ALARM_ID_DD_NVM_INVALID_INSTIT_ADDITIONAL_RECORD_CRC = 238 # DD invalid additional institutional record - ALARM_ID_FP_NVM_INVALID_SERVICE_RECORD_CRC = 239 # FP invalid serivice record - ALARM_ID_FP_NVM_INVALID_USAGE_RECORD_CRC = 240 # FP invalid usage record + ALARM_ID_TD_RECIRC_TIMEOUT_WARNING = 235 # TD recirculate timeout warning + ALARM_ID_TD_RECIRC_TIMEOUT = 236 # TD recirculate timeout + ALARM_ID_FW_RESERVED_237 = 237 # FW reserved for use + ALARM_ID_FW_RESERVED_238 = 238 # FW reserved for use + ALARM_ID_FW_RESERVED_239 = 239 # FW reserved for use + ALARM_ID_FW_RESERVED_240 = 240 # FW reserved for use ALARM_ID_FW_RESERVED_241 = 241 # FW reserved for use ALARM_ID_FW_RESERVED_242 = 242 # FW reserved for use ALARM_ID_FW_RESERVED_243 = 243 # FW reserved for use