Index: leahi_dialin/common/dd_defs.py =================================================================== diff -u -r02eb470cf6682c89062c8a62eaf0a08a2728b18a -rc5bfcf84ed942ca5841bf9de155aa0f495b4d28d --- leahi_dialin/common/dd_defs.py (.../dd_defs.py) (revision 02eb470cf6682c89062c8a62eaf0a08a2728b18a) +++ leahi_dialin/common/dd_defs.py (.../dd_defs.py) (revision c5bfcf84ed942ca5841bf9de155aa0f495b4d28d) @@ -7,380 +7,666 @@ # # @file dd_defs.py # -# @author (last) Dara Navaei -# @date (last) 08-Feb-2024 +# @author (last) Zoltan Miskolci +# @date (last) 13-Jan-2026 # @author (original) Peter Lucia # @date (original) 22-Jun-2021 # ############################################################################ + from enum import unique +from aenum import extend_enum +from typing import TYPE_CHECKING + +from .global_vars import GlobalVariables, test_config_change from ..utils.base import DialinEnum -@unique -class DDOpModes(DialinEnum): - MODE_FAUL = 0 # Fault Mode - MODE_SERV = 1 # Service Mode - MODE_INIT = 2 # Initialization & POST Mode - MODE_STAN = 3 # Standby Mode - MODE_PREG = 4 # Pre-generate Dialysate Mode - MODE_GEND = 5 # Generate Dialysate Mode - MODE_POSG = 6 # Post-generate Dialysate Mode - MODE_HEAT = 7 # Heat Mode - MODE_HCOL = 8 # Cooling Mode - MODE_ROPS = 9 # RO Permeate Sample Mode - MODE_NLEG = 10 # Non-legal Mode - an illegitimate mode transition has occurred - NUM_OF_DD_MODES = 11 # Number of Modes for the DD +class DD_Defs: -@unique -class DDInitStates(DialinEnum): - DD_POST_STATE_START = 0 # Post Generate Dialysate Start State - DD_POST_STATE_FW_COMPATIBILITY = 1 # Firmware Compatibility State - DD_POST_STATE_FW_INTEGRITY = 2 # Firmware Integrity State - DD_POST_STATE_FPGA = 3 # FPGA State - DD_POST_STATE_NVDATAMGMT = 4 # Non-volatile Data Management State - DD_POST_STATE_TEMPERATURE_SENSORS = 5 # Temperature Sensors State - DD_POST_STATE_PRESSURES = 6 # Pressure Sensors State - DD_POST_STATE_DIALYSATE_PUMPS = 7 # Dialysate Pumps State - DD_POST_STATE_CONCENTRATE_PUMPS = 8 # Concentrate Pumps State - DD_POST_STATE_CONDUCTIVITY_SENSORS = 9 # Conductivity Sensors State - DD_POST_STATE_WATCHDOG = 10 # Watchdog State - DD_POST_STATE_SAFETY_SHUTDOWN = 11 # Safety Shutdown State - DD_POST_STATE_COMPLETED = 12 # Post Generate Dialysate Completed State - DD_POST_STATE_FAILED = 13 # Post Generate Dialysate Fail State - NUM_OF_DD_POST_STATES = 14 # Number of Post Generate Dialysate States + # IDE autocomplete support + if TYPE_CHECKING: + DDOpModes: DialinEnum + DDFaultStates: DialinEnum + DDFaultNVDataStates: DialinEnum + DDServiceStates: DialinEnum + DDInitStates: DialinEnum + DDStandbyStates: DialinEnum + DDPreGenDialysateStates: DialinEnum + DDGenDialysateModeStates: DialinEnum + DDPostGenDialysateStates: DialinEnum + DDHeatDisinfectStates: DialinEnum + DDHeaterCoolingStates: DialinEnum + DDROPermeateStates: DialinEnum + DDNotLegalStates: DialinEnum + DDEventList: DialinEnum + DDEventDataTypes: DialinEnum -@unique -class DDFaultStates(DialinEnum): - DD_FAULT_STATE_START = 0 # DD fault start state - DD_FAULT_DEENERGIZED_STATE = 1 # DD fault de-energized state - DD_FAULT_ENERGIZED_STATE_ = 2 # DD fault energized state - NUM_OF_DD_FAULT_STATES = 3 # Number of fault mode states + DDConcentratePumpNames:DialinEnum + DDConductivitySensorNames:DialinEnum + DDDialysatePumpNames:DialinEnum + DDHeaterNames:DialinEnum + DDLevelSensorNames:DialinEnum + DDPistonPumpNames:DialinEnum + DDPressureSensorNames:DialinEnum + DDTemperatureSensorNames: DialinEnum + DDValveNames: DialinEnum + DDMonitoredVoltages: DialinEnum -@unique -class DDFaultNVDataStates(DialinEnum): - DD_FAULT_STATE_START = 0 # DD fault start state - DD_FAULT_STATE_RUN_NV_POSTS = 1 # DD fault run RTC and NV data management post - DD_FAULT_STATE_COMPLETE = 2 # DD fault complete - NUM_OF_DD_FAULT_NVDATA_STATES = 3 # Number of fault mode NV Data management states + DDBalancingChamberStates:DialinEnum + DDBalancingChamberSwitchStates:DialinEnum + DDBloodLeakStates:DialinEnum + DDConcentratePumpAttributes:DialinEnum + DDConcentratePumpStates:DialinEnum + DDDialysatePumpAttributes:DialinEnum + DDDialysatePumpsStates:DialinEnum + DDHeaterStartStop:DialinEnum + DDHeaterAttributes:DialinEnum + DDHeaterExecState:DialinEnum + DDPistonPumpAttributes:DialinEnum + DDValveStates: DialinEnum -@unique -class DDStandByModeStates(DialinEnum): - DD_STANDBY_MODE_STATE_IDLE = 0 # Idle standby mode state - DD_STANDBY_MODE_STATE_PAUSE = 1 # Pause state - NUM_OF_DD_STANDBY_MODE_STATES = 2 # Number of standby mode states + _properties = { + # Operation / State enums + 'DDOpModes': '_create_dd_operation_modes', + 'DDFaultStates': '_create_dd_fault_states', + 'DDFaultNVDataStates': '_create_dd_fault_nvdata_states', + 'DDServiceStates': '_create_dd_service_states', + 'DDInitStates': '_create_dd_init_states', + 'DDStandbyStates': '_create_dd_standby_states', + 'DDPreGenDialysateStates': '_create_dd_pregen_states', + 'DDGenDialysateModeStates': '_create_dd_gen_states', + 'DDPostGenDialysateStates': '_create_dd_postgen_states', + 'DDHeatDisinfectStates': '_create_dd_heat_disinfect_states', + 'DDHeaterCoolingStates': '_create_dd_heater_cooling_states', + 'DDROPermeateStates': '_create_dd_ro_permeate_states', + 'DDNotLegalStates': '_create_dd_not_legal_states', -@unique -class DDPreGenDialysateStates(DialinEnum): - DD_PRE_GEN_DIALYSATE_HYD_CHAMBER_FILL_CHECK = 0, # DD Pre-Gen Dialysate hyrochamber fill check - DD_PRE_GEN_WET_SELF_TEST = 1 # DD Pre-Gen Wet Self Test - DD_PRE_GEN_DIALYSATE_WAIT_FOR_GEND = 2 # DD Pre-Gen Dialysate Wait for Gen Dialysate state transition - NUM_OF_DD_PRE_GEN_DIALYSATE_STATES = 3 # Number of Pre-Gen Dialysate mode states + # Event enums + 'DDEventList': '_create_dd_event_list', + 'DDEventDataTypes': '_create_dd_event_data_types', -@unique -class DDGenDialysateModeStates(DialinEnum): - DD_GEND_STATE_START = 0 # Gen dialysate start state - DD_GEND_DIALYSATE_BYPASS_STATE = 1 # Gen dialysate - Bypass dialysate state - DD_GEND_DIALYSATE_DELIVERY_STATE = 2 # Gen dialysate - deliver dialysate state - DD_GEND_ISOLATED_UF_STATE = 3 # Gen dialysate - Isolated ultrafiltration state - DD_GEND_SPENT_CHAMBER_FILL_STATE = 4 # Gen dialysate - spent chamber fill state - DD_GEND_BICARB_CHAMBER_FILL_STATE = 5 # Gen dialysate - bicarb chamber fill state - DD_GEND_DIALYSATE_DELIVERY_PAUSE = 6 # Gen dialysate - dialysate delivery pause state - NUM_OF_DD_GEND_MODE_STATES = 7 # Number of gen dialysate states + # Module Names enums + 'DDConcentratePumpNames': '_create_dd_concentrate_pump_names', + 'DDConductivitySensorNames': '_create_dd_conductivity_sensor_names', + 'DDDialysatePumpNames': '_create_dd_dialysate_pump_names', + 'DDHeaterNames': '_create_dd_heater_names', + 'DDLevelSensorNames': '_create_dd_level_sensor_names', + 'DDPistonPumpNames': '_create_dd_piston_pump_names', + 'DDPressureSensorNames': '_create_dd_pressure_sensor_names', + 'DDTemperatureSensorNames': '_create_dd_temperature_sensor_names', + 'DDValveNames': '_create_dd_valve_names', + 'DDMonitoredVoltages': '_create_dd_monitored_voltages', -@unique -class DDPostGenDialysateState(DialinEnum): - DD_POST_GEN_DIALYSATE_STATE_START = 0 # DD Post-Gen Dialysate state start - DD_POST_GEN_DIALYSATE_STATE_COMPLETE = 1 # DD Post-Gen Dialysate complete state - NUM_OF_DD_POST_GEN_DIALYSATE_STATES = 2 # Number of Post-Gen Dialysate mode states + # Support enums + 'DDBalancingChamberStates': '_create_dd_balancing_chamber_states', + 'DDBalancingChamberSwitchStates': '_create_dd_balancing_chamber_switch_states', + 'DDBloodLeakStates': '_create_dd_blood_leak_states', + 'DDConcentratePumpAttributes': '_create_dd_concentrate_pump_attributes', + 'DDConcentratePumpStates': '_create_dd_concentrate_pump_states', + 'DDDialysatePumpAttributes': '_create_dd_dialysate_pump_attributes', + 'DDDialysatePumpsStates': '_create_dd_dialysate_pump_states', + 'DDHeaterStartStop': '_create_dd_heater_start_stop', + 'DDHeaterAttributes': '_create_dd_heater_attributes', + 'DDHeaterExecState': '_create_dd_heater_exec_states', + 'DDPistonPumpAttributes': '_create_dd_piston_pump_attributes', + 'DDValveStates': '_create_dd_valve_states', + } -@unique -class DDEventList(DialinEnum): - DD_EVENT_STARTUP = 0 # DD startup event - DD_EVENT_OP_MODE_CHANGE = 1 # DD Op mode change event - DD_EVENT_SUB_MODE_CHANGE = 2 # DD Op sub-mode change event - DD_EVENT_OPERATION_STATUS = 3 # DD operation status event - DD_EVENT_D6_LEVL_CHANGE = 4 # DD floater level change event - DD_EVENT_D63_LEVL_CHANGE = 5 # DD bicarb level change event - DD_EVENT_D46_LEVL_CHANGE = 6 # DD spent dialysate air seperation level change event - DD_EVENT_TD_COMMUNICATION_LOSS = 7 # DD TD communication loss - DD_EVENT_TEMPERATURE_DRIFT = 8 # DD dialysate temperature drift - DD_EVENT_BLOOD_LEAK_ZEROING_REQUEST = 9 # DD blood leak zeroing request - DD_EVENT_BLOOD_LEAK_ZEROING_REQUIRED = 10 # DD blood leak zeroing required - DD_EVENT_BLOOD_LEAK_NUM_OF_SET_POINT_CHECK_FAILURES = 11 # DD blood leak number of setpoint check failures - DD_EVENT_BLOOD_LEAK_SELF_TEST_RESULT = 12 # DD blood leak self test result - NUM_OF_DD_EVENT_IDS = 13 # Total number of DD events + def __init__(self): + self.update_enums() -@unique -class DDEventDataType(DialinEnum): - EVENT_DATA_TYPE_NONE = 0 # No Event Data Type - EVENT_DATA_TYPE_U32 = 1 # Unsigned 32bit Event Data Type - EVENT_DATA_TYPE_S32 = 2 # Signed 32bit Event Data Type - EVENT_DATA_TYPE_F32 = 3 # Float 32bit Event Data Type - EVENT_DATA_TYPE_BOOL = 4 # Boolean Event Data Type - NUM_OF_EVENT_DATA_TYPES = 5 # Number of Event Data Types -@unique -class DDServiceModesStates(DialinEnum): - DD_SERVICE_STATE_START = 0 # Start service mode state - NUM_OF_DD_SERVICE_STATES = 1 # Number of service mode states + def __getattr__(self, name) -> DialinEnum: + if name in self._properties: + enum = getattr(self, self._properties[name])() + setattr(self, name, enum) + return enum + raise AttributeError(name) -@unique -class DDBalancingChamberStates(DialinEnum): - BAL_CHAMBER_STATE_START = 0, # Initial state of balancing chamber - BAL_CHAMBER_STATE1_FILL_START = 1 # Balancing chamber state 1 fill start state - BAL_CHAMBER_STATE1_BICARB_ACID_DOSING_CNTRL = 2 # Balancing Chamber state 1 Bicarb and acid dosing control state - BAL_CHAMBER_STATE1_FILL_END = 3 # Balancing Chamber state 1 fill end state - BAL_CHAMBER_STATE2_FILL_START = 4 # Balancing chamber state 2 fill start state - BAL_CHAMBER_STATE2_BICARB_ACID_DOSING_CNTRL = 5 # Balancing Chamber state 2 Bicarb and acid dosing control state - BAL_CHAMBER_STATE2_FILL_END = 6 # Balancing Chamber state 2 fill end state - NUM_OF_BAL_CHAMBER_EXEC_STATES = 7 # Number of balancing chamber states -@unique -class DDBalancingChamberSwitchStates(DialinEnum): - BAL_CHAMBER_SW_STATE1 = 0 # Balancing chamber switching state 1 (V2,V5 and V3, V8 open, rest closed) - BAL_CHAMBER_SW_STATE2 = 1 # Balancing chamber switching state 2 ( V1,V6 and V4, V7 open, rest closed) - NUM_OF_BAL_CHAMBER_SW = 2 # Number of balancing chamber states + def update_enums(self) -> None: + for prop_name in self._properties: + # Cleans the cached value + self.__dict__.pop(prop_name, None) + + # Reinitializing the enum as it's not in the cache + self.__getattr__(prop_name) -@unique -class DDBloodLeakStates(DialinEnum): - """ - DD blood leak embedded mode state machine states - """ - BLOOD_LEAK_WAIT_FOR_POST_STATE = 0 - BLOOD_LEAK_CHECK_SET_POINT_STATE = 1 - BLOOD_LEAK_INIT_STATE = 2 - BLOOD_LEAK_CHECK_ZERO_AND_SELF_TEST_STATE = 3 - BLOOD_LEAK_VERIFY_INTENSITY_AFTER_ZEROING_STATE = 4 - BLOOD_LEAK_NORMAL_STATE = 5 - BLOOD_LEAK_RECOVER_BLOOD_DETECT_STATE = 6 - NUM_OF_BLOOD_LEAK_STATES = 7 -@unique -class DDConcentratePumpsEnum(DialinEnum): - D11_CP1_ACID = 0 # Acid Concentrate Pump - D10_CP2_BICARB = 1 # Bicarbonate Concentrate Pump - D76_UF = 2 # Ultrafiltration Concentrate Pump - NUM_OF_CONCENTRATE_PUMPS = 3 # Number of Concentrate Pumps -@unique -class DDConcentratePumpsStates(DialinEnum): - CONCENTRATE_PUMP_OFF_STATE = 0 # Concentrate Pump Off State - CONCENTRATE_PUMP_RAMP_TO_TARGET_SPEED_STATE = 1 # Ramp to Target Speed Concentrate Pump State - CONCENTRATE_PUMP_CONTROL_TARGET_SPEED_STATE = 2 # Control Target Speed Concentrate Pump State - NUM_OF_CONCENTRATE_PUMP_STATES = 3 # Number of Concentrate Pump States + # ================================================== Enum Creators: Operations ================================================== + def _create_dd_operation_modes(self): + members = { + 'MODE_FAUL': 0, # Fault Mode + 'MODE_SERV': 1, # Service Mode + 'MODE_INIT': 2, # Initialization & POST Mode + 'MODE_STAN': 3, # Standby Mode + 'MODE_PREG': 4, # Pre-generate Dialysate Mode + 'MODE_GEND': 5, # Generate Dialysate Mode + 'MODE_POSG': 6, # Post-generate Dialysate Mode + 'MODE_HEAT': 7, # Heat Disinfect Mode + 'MODE_HCOL': 8, # Cooling Mode + 'MODE_ROPS': 9, # RO Permeate Sample Mode + 'MODE_NLEG': 10, # Non-legal Mode - an illegitimate mode transition has occurred + 'NUM_OF_DD_MODES': 11, # Number of Modes for the DD + } + return unique(DialinEnum('DDOpModes', members)) -@unique -class DDConcentratePumpAttributesEnum(DialinEnum): - CURRENT_STATE = 0 # Current State Concentrate Pump Attribute - CURRENT_SET_SPEED = 1 # Current Set Speed Concentrate Pump Attribute - MEASURED_SPEED = 2 # Measured Speed Concentrate Pump Attribute - TARGET_SPEED = 3 # Target Speed Concentrate Pump Attribute - PULSE_US = 4 # Hall Sensor Pulse Width (in micro seconds) Concentrate Pump Attribute - TARGET_REV_COUNT = 5 # Target Revolutions Concentrate Pump Attribute - MEASURED_REV_COUNT = 6 # Measured Revolutions Concentrate Pump Attribute - PARKED = 7 # Parked Concentrate Pump Attribute - PARK_FAULT = 8 # Park Fault Concentrate Pump Attribute - NUM_OF_D10_D11_CONCENTRATE_PUMP_ATTRIBUTES = 9 # Number of Acid (D11) and Bicarbonate (D10) Concentrate Pump Attributes -@unique -class DDConductivitySensorsEnum(DialinEnum): - D17_COND = 0 # Closed Loop Control of Dosing for D74 Conductivity Sensor - D27_COND = 1 # Closed Loop Control of Dosing for D29 Conductivity Sensor - D29_COND = 2 # Water, Bicarbonate, and Acid Collective Conductivity Sensor - D43_COND = 3 # Self Test Conductivity Sensor (not used for dialysate conductivity) - D74_COND = 4 # Water and Bicarbonate Collective Conductivity Sensor - NUM_OF_CONDUCTIVITY_SENSORS = 5 # Number of Conductivity Sensors + def _create_dd_fault_states(self): + members = { + 'DD_FAULT_STATE_START': 0, # DD fault start state + 'DD_FAULT_DEENERGIZED_STATE': 1, # DD fault de-energized state + 'DD_FAULT_ENERGIZED_STATE': 2, # DD fault energized state + 'NUM_OF_DD_FAULT_STATES': 3, # Number of fault mode states + } + return unique(DialinEnum('DDFaultStates', members)) -@unique -class DDDialysatePumpsEnum(DialinEnum): - D12_PUMP = 0 # Fresh Dialysate Pump - D48_PUMP = 1 # Spent Dialysate Pump - NUM_OF_DIALYSATE_PUMPS = 2 # Number of Dialysate Pumps -@unique -class DDDialysatePumpAttributesEnum(DialinEnum): - TARGET_RPM = 0 # Target RPM Dialysate Pump Attribute - MEASURED_SPEED = 1 # Measured Speed Dialysate Pump Attribute - CURRENT_SPEED = 2 # Current Speed Dialysate Pump Attribute - STATE = 3 # State to command Dialysate Pump Attribute - TARGET_PRESSURE = 4 # Target Pressure Dialysate Pump Attribute - MEASURED_PRESSURE = 5 # Measured Pressure Dialysate Pump Attribute - MEASURED_CURRENT = 6 # Measured Current Dialysate Pump Attribute - CONTROL = 7 # Pump Run/Stop Control Pump Attribute - DIRECTION_ERROR_COUNT = 8 # Direction Error Count Dialysate Pump Attribute - MEASURED_DIRECTION = 9 # Measured Direction Dialysate Pump Attribute - NUM_OF_DIALYSATE_PUMP_ATTRIBUTES = 10 # Number of Dialysate Pump Attributes + def _create_dd_fault_nvdata_states(self): + members = { + 'DD_FAULT_STATE_START': 0, # DD fault start state + 'DD_FAULT_STATE_RUN_NV_POSTS': 1, # DD fault run RTC and NV data management post + 'DD_FAULT_STATE_COMPLETE': 2, # DD fault complete + 'NUM_OF_DD_FAULT_NVDATA_STATES': 3, # Number of fault mode NV Data management states + } + return unique(DialinEnum('DDFaultNVDataStates', members)) -@unique -class DDDialysatePumpsStates(DialinEnum): - DIALYSATE_PUMP_OFF_STATE = 0 # Dialysate Pump Off State - DIALYSATE_PUMP_RAMP_UP_STATE = 1 # Dialysate Pump Ramp Up State - DIALYSATE_PUMP_CONTROL_TO_TARGET_STATE = 2 # Dialysate Pump Control to Target State - NUM_OF_DIALYSATE_PUMP_STATES = 3 # Number of Dialysate Pump States -@unique -class DDHeatersStartStop(DialinEnum): - STOP = 0 - START = 1 + def _create_dd_service_states(self): + members = { + 'DD_SERVICE_STATE_START': 0, # Start service mode state + 'NUM_OF_DD_SERVICE_STATES': 1, # Number of service mode states + } + return unique(DialinEnum('DDServiceStates', members)) -@unique -class DDHeatersState(DialinEnum): - DD_HEAT_DISINFECT_STATE_START = 0 # Heat disinfect, start mode state - DD_HEAT_DISINFECT_STATE_COMPLETE = 1 # Heat disinfect, complete state - NUM_OF_DD_HEAT_DISINFECT_STATES = 2 # Number of heat disinfect mode states -@unique -class DDHeatersExecState(DialinEnum): - HEATER_EXEC_STATE_OFF = 0 # Heater Execution Off State - HEATER_EXEC_STATE_RAMP_TO_TARGET = 1 # Heater Execution Ramp to Target State - HEATER_EXEC_STATE_CONTROL_TO_TARGET = 2 # Heater Execution Control to Target State - HEATER_EXEC_STATE_CONTROL_TO_DISINFECT_TARGET = 3 # Heater Execution Control to Disinfection State - NUM_OF_HEATERS_EXEC_STATE = 4 + def _create_dd_init_states(self): + members = { + 'DD_POST_STATE_START': 0, # Post Generate Dialysate Start State + 'DD_POST_STATE_FW_COMPATIBILITY': 1, # Firmware Compatibility State + 'DD_POST_STATE_FW_INTEGRITY': 2, # Firmware Integrity State + 'DD_POST_STATE_FPGA': 3, # FPGA State + 'DD_POST_STATE_NVDATAMGMT': 4, # Non-volatile Data Management State + 'DD_POST_STATE_TEMPERATURE_SENSORS': 5, # Temperature Sensors State + 'DD_POST_STATE_PRESSURES': 6, # Pressure Sensors State + 'DD_POST_STATE_DIALYSATE_PUMPS': 7, # Dialysate Pumps State + 'DD_POST_STATE_CONCENTRATE_PUMPS': 8, # Concentrate Pumps State + 'DD_POST_STATE_CONDUCTIVITY_SENSORS': 9, # Conductivity Sensors State + 'DD_POST_STATE_WATCHDOG': 10, # Watchdog State + 'DD_POST_STATE_SAFETY_SHUTDOWN': 11, # Safety Shutdown State + 'DD_POST_STATE_COMPLETED': 12, # Post Generate Dialysate Completed State + 'DD_POST_STATE_FAILED': 13, # Post Generate Dialysate Fail State + 'NUM_OF_DD_POST_STATES': 14, # Number of Post Generate Dialysate States + } + return unique(DialinEnum('DDInitStates', members)) -@unique -class DDHeatersNames(DialinEnum): - D5_HEAT = 0 # Primary heater - D45_HEAT = 1 # Trimmer heater - NUM_OF_DD_HEATERS = 2 # Number of Heaters -@unique -class DDHeatersAttributesEnum(DialinEnum): - HEAT_DUTY_CYCLE = 0 # Heat Duty Cycle Attribute for Heaters - HEAT_TARGET_TEMP = 1 # Target Temperature Attribute for Heaters - HEAT_STATE = 2 # State to command Attribute for Heaters - DUTY_CYCLE_COUNT = 3 # Duty Cycle Count Attribute for Heaters - PWM_PERIOD = 4 # Pulse Width Modulation Attribute for Heaters - ADJUSTED_TARGET_TEMP = 5 # Adjusted Target Temperature Attribute for Heaters - TARGET_TEMP_TD = 6 # Target Temperature Attribute for Heaters - NUM_OF_DD_HEATER_ATTRIBUTES = 7 # Number of Heater Attributes + def _create_dd_standby_states(self): + members = { + 'DD_STANDBY_MODE_STATE_IDLE': 0, # Idle standby mode state + 'DD_STANDBY_MODE_STATE_PAUSE': 1, # Pause state + 'NUM_OF_DD_STANDBY_MODE_STATES': 2, # Number of standby mode states + } + return unique(DialinEnum('DDStandbyStates', members)) -@unique -class DDHeatersCoolingStates(DialinEnum): - NUM_OF_DD_HEAT_COOL_STATES = 0 # TODO: populate with heater cooling states -@unique -class DDLevelSensorEnum(DialinEnum): - D6_LEVEL = 0 # floater switch low, medium and high status - D63_LEVEL = 1 # bicarb level low or high status - D46_LEVEL = 2 # Spent dialysate air separation chamber level low or high status - NUM_OF_LEVELS = 3 # Number of Level Sensors + def _create_dd_pregen_states(self): + members = { + 'DD_PRE_GEN_DIALYSATE_HYD_CHAMBER_FILL_CHECK': 0, # DD Pre-Gen Dialysate hyrochamber fill check + 'DD_PRE_GEN_WET_SELF_TEST': 1, # DD Pre-Gen Wet Self Test + 'DD_PRE_GEN_DIALYSATE_WAIT_FOR_GEND': 2, # DD Pre-Gen Dialysate Wait for Gen Dialysate state transition + 'NUM_OF_DD_PRE_GEN_DIALYSATE_STATES': 3, # Number of Pre-Gen Dialysate mode states + } -@unique -class DDPistonPumpsEnum(DialinEnum): - ACID = 0 # Acid piston pump - BICARB = 1 # Bicarbonate piston pump - UF = 2 # Ultrafiltration piston pump - NUM_OF_PISTON_PUMPS = 3 # Number of piston pumps + return unique(DialinEnum('DDPreGenDialysateStates', members)) -@unique -class DDPistonPumpAttributesEnum(DialinEnum): - CONTROL_STATE = 0 # Control State for the Piston Pumps - SW_COUNTER = 1 # Software counter attribute for the Piston Pumps - CYCLE_COUNTER = 2 # Cycle Counter for the Piston Pumps - NUM_OF_PISTON_PUMP_ATTRIBUTES = 3 # Number of Piston Pump Attributes -@unique -class DDPressureNames(DialinEnum): - # Pressure Sensor IDs - D9_PRES = 0 # Hydraulics outlet pressure (PHo/Pn) - D66_PRES = 1 # Dry Bicarb pressure (PDB/PCb) - D51_PRES = 2 # Spent Dialysate pressure (PDs) - D18_PRES = 3 # Fresh Dialysate pressure (PDf) - D41_PRES = 4 # Transmembrane pressure (Ptm) - NUM_OF_PRESSURE_SENSORS = 5 # Number of pressure sensors + def _create_dd_gen_states(self): + members = { + 'DD_GEND_STATE_START': 0, # Gen dialysate start state + 'DD_GEND_DIALYSATE_BYPASS_STATE': 1, # Gen dialysate - Bypass dialysate state + 'DD_GEND_DIALYSATE_DELIVERY_STATE': 2, # Gen dialysate - deliver dialysate state + 'DD_GEND_ISOLATED_UF_STATE': 3, # Gen dialysate - Isolated ultrafiltration state + 'DD_GEND_SPENT_CHAMBER_FILL_STATE': 4, # Gen dialysate - spent chamber fill state + 'DD_GEND_BICARB_CHAMBER_FILL_STATE': 5, # Gen dialysate - bicarb chamber fill state + 'DD_GEND_DIALYSATE_DELIVERY_PAUSE': 6, # Gen dialysate - dialysate delivery pause state + 'NUM_OF_DD_GEND_MODE_STATES': 7, # Number of gen dialysate states + } -COND_SENSOR_INDEX_OFFSET = 6 # Conductivity Sensor Index Offset for the Temperature Readings -PRES_SENSOR_INDEX_OFFSET = 15 # Pressure Sensors Offset for Temperature Readings + return unique(DialinEnum('DDGenDialysateModeStates', members)) -@unique -class DDROPermeateStates(DialinEnum): - NUM_OF_RO_PERMEATE_STATES = 0 # TODO: populate with RO Permeate states -@unique -class DDTemperaturesNames(DialinEnum): - D1_TEMP = 0 # Heat exchanger Inlet temperature sensor - D78_TEMP = 1 # Heat exchanger Outlet temperature sensor - D4_TEMP = 2 # Hydraulics primary heater temperature sensor - D50_TEMP = 3 # Trimmer heater temperature sensor - BRD_TEMP = 4 # Barometric temperature sensor - D16_TEMP = 5 # D16 Conductivity sensor temperature value - D28_TEMP = 6 # D28 Conductivity sensor temperature value - D30_TEMP = 7 # D30 Conductivity sensor temperature value - D44_TEMP = 8 # D44 Conductivity sensor temperature value - D75_TEMP = 9 # D75 Conductivity sensor temperature value - D4_AVG_TEMP = 10 # D4 Filtered value - D50_AVG_TEMP = 11 # D50 Filtered value - D28_AVG_TEMP = 12 # D28 Filtered value - D30_AVG_TEMP = 13 # D30 Filtered value - D9_TEMP = 14 # D9 Pressure sensor temperature value - D66_TEMP = 15 # D66 Pressure sensor temperature value - D51_TEMP = 16 # D51 Pressure sensor temperature value - D18_TEMP = 17 # D18 Pressure sensor temperature value - D41_TEMP = 18 # D41 Pressure sensor temperature value - NUM_OF_TEMP_SENSORS = 19 # Number of Temperature Sensors + def _create_dd_postgen_states(self): + members = { + 'DD_POST_GEN_DIALYSATE_STATE_START': 0, # DD Post-Gen Dialysate state start + 'DD_POST_GEN_DIALYSATE_STATE_COMPLETE': 1, # DD Post-Gen Dialysate complete state + 'NUM_OF_DD_POST_GEN_DIALYSATE_STATES': 2, # Number of Post-Gen Dialysate mode states + } -@unique -class DDValveStates(DialinEnum): - VALVE_STATE_CLOSED = 0 # Valve Closed State - VALVE_STATE_OPEN = 1 # Valve Open State + return unique(DialinEnum('DDPostGenDialysateStates', members)) -@unique -class DDValveNames(DialinEnum): - D14_VALV = 0 # Valve Hydraulics Outlet (D14) - D52_VALV = 1 # Valve Thermal Disinfect (D52) - D8_VALV = 2 # Valve Hydraulics Bypass (D8) - D54_VALV = 3 # Valve Rinse Port (D54) - D53_VALV = 4 # Valve Drain (D53) - D34_VALV = 5 # Valve Dialyzer Bypass (D34) - D64_VALV = 6 # Valve Purge 1 (D64) - D31_VALV = 7 # Valve Pressure Test (D31) - D65_VALV = 8 # Valve DryBcarb Inlet (D65) - D35_VALV = 9 # Valve Dialyzer Inlet (D35) - D40_VALV = 10 # Valve Dialyzer Outlet (D40) - D47_VALV = 11 # Valve Dialysate Out Purge 2 (D47) - D3_VALV = 12 # Valve Hydraulics Inlet (D3) - D80_VALV = 13 # Valve Dry Bicarb (D80) - D81_VALV = 14 # Valve De-scaler (D81) - RSRVD_SPACE1 = 15 # This space has been reserved - D23_VALV = 16 # Balancing chamber Valve 1 (D23) - D19_VALV = 17 # Balancing chamber Valve 2 (D19) - D25_VALV = 18 # Balancing chamber Valve 3 (D25) - D21_VALV = 19 # Balancing chamber Valve 4 (D21) - D24_VALV = 20 # Balancing chamber Valve 5 (D24) - D20_VALV = 21 # Balancing chamber Valve 6 (D20) - D26_VALV = 22 # Balancing chamber Valve 7 (D26) - D22_VALV = 23 # Balancing chamber Valve 8 (D22) - D79_PMP_VALV = 24 # D79 pump mapped to spare valve 0 - SPARE1_VALV = 25 # Spare Valve 1 - SPARE2_VALV = 26 # Spare Valve 2 - SPARE3_VALV = 27 # Spare Valve 3 - SPARE4_VALV = 28 # Spare Valve 4 - SPARE5_VALV = 29 # Spare Valve 5 - SPARE6_VALV = 30 # Spare Valve 6 - SPARE7_VALV = 31 # Spare Valve 7 - M4_VALV = 32 # First IO valve (M4) - M12_VALV = 33 # Last IO valve IO valve (M12) - P11_VALV = 34 # First FP Valve (P11) - P33_VALV = 35 # FP Valve (P33) - P34_VALV = 36 # FP Valve (P34) - P37_VALV = 37 # FP Valve (P37) - P39_VALV = 38 # FP Valve (P39) - P6_VALV = 39 # Last FP Valve (P6) - NUM_OF_DD_VALVES = 40 # Number of Valves for the DD -@unique -class DDNotLegalStates(DialinEnum): - NUM_OF_NOT_LEGAL_STATES = 0 # TODO: populate with Not Legal states + def _create_dd_heat_disinfect_states(self): + members = { + 'DD_HEAT_DISINFECT_STATE_START': 0, # Heat disinfect, start mode state + 'DD_HEAT_DISINFECT_STATE_COMPLETE': 1, # Heat disinfect, complete state + 'NUM_OF_DD_HEAT_DISINFECT_STATES': 2 # Number of heat disinfect mode states + } + return unique(DialinEnum('DDHeatDisinfectStates', members)) -@unique -class DDMonitoredVoltages(DialinEnum): - MONITORED_LINE_1_2V = 0 # Processor voltage (1.2V) - MONITORED_LINE_3_3V = 1 # Logic voltage (3.3V) - MONITORED_LINE_5V_LOGIC = 2 # Logic voltage (5V) - MONITORED_LINE_24V_1 = 3 # Actuators voltage (24V) - MONITORED_LINE_24V_2 = 4 # Actuators regen voltage (24V) - MONITORED_LINE_FPGA_VCC_V = 5 # FPGA Vcc (3V) - MONITORED_LINE_FPGA_AUX_V = 6 # FPGA Vaux (3V) - MONITORED_LINE_FPGA_PVN_V = 7 # FPGA Vpvn (1V) - NUM_OF_MONITORED_VOLTAGE_LINES = 8 # Number of TD operation modes \ No newline at end of file + + def _create_dd_heater_cooling_states(self): + members = { + 'NUM_OF_DD_HEAT_COOL_STATES': 0, # Number of Heater Cooling states + } + return unique(DialinEnum('DDHeaterCoolingStates', members)) + + + def _create_dd_ro_permeate_states(self): + members = { + 'NUM_OF_RO_PERMEATE_STATES': 0, # Number of RO Permeate states + } + return unique(DialinEnum('DDROPermeateStates', members)) + + + def _create_dd_not_legal_states(self): + members = { + 'NUM_OF_NOT_LEGAL_STATES': 0, # Number of Not Legal states + } + return unique(DialinEnum('DDNotLegalStates', members)) + + + def _create_dd_event_list(self): + members = { + 'DD_EVENT_STARTUP': 0, # DD startup event + 'DD_EVENT_OP_MODE_CHANGE': 1, # DD Op mode change event + 'DD_EVENT_SUB_MODE_CHANGE': 2, # DD Op sub-mode change event + 'DD_EVENT_OPERATION_STATUS': 3, # DD operation status event + 'DD_EVENT_D6_LEVL_CHANGE': 4, # DD floater level change event + 'DD_EVENT_D63_LEVL_CHANGE': 5, # DD bicarb level change event + 'DD_EVENT_D46_LEVL_CHANGE': 6, # DD spent dialysate air seperation level change event + 'DD_EVENT_TD_COMMUNICATION_LOSS': 7, # DD TD communication loss + 'DD_EVENT_TEMPERATURE_DRIFT': 8, # DD dialysate temperature drift + 'DD_EVENT_BLOOD_LEAK_ZEROING_REQUEST': 9, # DD blood leak zeroing request + 'DD_EVENT_BLOOD_LEAK_ZEROING_REQUIRED': 10, # DD blood leak zeroing required + 'DD_EVENT_BLOOD_LEAK_NUM_OF_SET_POINT_CHECK_FAILURES': 11, # DD blood leak number of setpoint check failures + 'DD_EVENT_BLOOD_LEAK_SELF_TEST_RESULT': 12, # DD blood leak self test result + 'NUM_OF_DD_EVENT_IDS': 13, # Total number of DD events + } + return unique(DialinEnum('DDEventList', members)) + + + def _create_dd_event_data_types(self): + members = { + 'EVENT_DATA_TYPE_NONE': 0, # No Event Data Type + 'EVENT_DATA_TYPE_U32': 1, # Unsigned 32bit Event Data Type + 'EVENT_DATA_TYPE_S32': 2, # Signed 32bit Event Data Type + 'EVENT_DATA_TYPE_F32': 3, # Float 32bit Event Data Type + 'EVENT_DATA_TYPE_BOOL': 4, # Boolean Event Data Type + 'NUM_OF_EVENT_DATA_TYPES': 5, # Number of Event Data Types + } + return unique(DialinEnum('DDEventDataTypes', members)) + + + + # ================================================== Enum Creators: Names ================================================== + def _create_dd_concentrate_pump_names(self): + members = { + 'D11_CP1_ACID': 0, # Acid Concentrate Pump + 'D10_CP2_BICARB': 1, # Bicarbonate Concentrate Pump + 'D76_UF': 2, # Ultrafiltration Concentrate Pump + 'NUM_OF_CONCENTRATE_PUMPS': 3, # Number of Concentrate Pumps + } + return unique(DialinEnum('DDConcentratePumpNames', members)) + + + def _create_dd_conductivity_sensor_names(self): + members = { + 'D17_COND': 0, # Closed Loop Control of Dosing for D74 Conductivity Sensor + 'D27_COND': 1, # Closed Loop Control of Dosing for D29 Conductivity Sensor + 'D29_COND': 2, # Water, Bicarbonate, and Acid Collective Conductivity Sensor + 'D43_COND': 3, # Self Test Conductivity Sensor (not used for dialysate conductivity) + 'D74_COND': 4, # Water and Bicarbonate Collective Conductivity Sensor + 'NUM_OF_CONDUCTIVITY_SENSORS': 5 # Number of Conductivity Sensors + } + return unique(DialinEnum('DDConductivitySensorNames', members)) + + + def _create_dd_dialysate_pump_names(self): + members = { + 'D12_PUMP': 0, # Fresh Dialysate Pump + 'D48_PUMP': 1, # Spent Dialysate Pump + 'NUM_OF_DIALYSATE_PUMPS': 2, # Number of Dialysate Pumps + } + return unique(DialinEnum('DDDialysatePumpNames', members)) + + + def _create_dd_heater_names(self): + members = { + 'D5_HEAT': 0, # Primary heater + 'D45_HEAT': 1, # Trimmer heater + 'NUM_OF_DD_HEATERS': 2, # Number of Heaters + } + return unique(DialinEnum('DDHeaterNames', members)) + + + def _create_dd_level_sensor_names(self): + if GlobalVariables().HW_BETA_1_9 == True: + members = { + 'D6_LEVEL': 0, # floater switch low, medium and high status + 'D63_LEVEL': 1, # bicarb level low or high status + 'D46_LEVEL': 2, # Spent dialysate air separation chamber level low or high status + 'D98_LEVEL': 3, # D98 Conductivity Level Sensor + 'NUM_OF_LEVELS': 4, # Number of Level Sensors + } + else: + members = { + 'D6_LEVEL': 0, # floater switch low, medium and high status + 'D63_LEVEL': 1, # bicarb level low or high status + 'D46_LEVEL': 2, # Spent dialysate air separation chamber level low or high status + 'NUM_OF_LEVELS': 3, # Number of Level Sensors + } + return unique(DialinEnum('DDLevelSensorNames', members)) + + + def _create_dd_piston_pump_names(self): + members = { + 'ACID': 0, # Acid piston pump + 'BICARB': 1, # Bicarbonate piston pump + 'UF': 2, # Ultrafiltration piston pump + 'NUM_OF_PISTON_PUMPS': 3, # Number of piston pumps + } + return unique(DialinEnum('DDPistonPumpNames', members)) + + + def _create_dd_pressure_sensor_names(self): + if GlobalVariables().HW_BETA_1_9 == True: + members = { + 'D9_PRES': 0, # Hydraulics outlet pressure (PHo/Pn) + 'D66_PRES': 1, # Dry Bicarb pressure (PDB/PCb) + 'D51_PRES': 2, # Spent Dialysate pressure (PDs) + 'D18_PRES': 3, # Fresh Dialysate pressure (PDf) + 'D41_PRES': 4, # Transmembrane pressure (Ptm) + 'D87_PRES': 5, # D87 Pressure Sensor + 'NUM_OF_PRESSURE_SENSORS': 6, # Number of pressure sensors + } + else: + members = { + 'D9_PRES': 0, # Hydraulics outlet pressure (PHo/Pn) + 'D66_PRES': 1, # Dry Bicarb pressure (PDB/PCb) + 'D51_PRES': 2, # Spent Dialysate pressure (PDs) + 'D18_PRES': 3, # Fresh Dialysate pressure (PDf) + 'D41_PRES': 4, # Transmembrane pressure (Ptm) + 'NUM_OF_PRESSURE_SENSORS': 5, # Number of pressure sensors + } + return unique(DialinEnum('DDPressureSensorNames', members)) + + + def _create_dd_temperature_sensor_names(self): + if GlobalVariables().HW_BETA_1_9 == True: + members = { + 'D1_TEMP': 0, # Heat exchanger Inlet temperature sensor + 'D78_TEMP': 1, # Heat exchanger Outlet temperature sensor + 'D4_TEMP': 2, # Hydraulics primary heater temperature sensor + 'D50_TEMP': 3, # Trimmer heater temperature sensor + 'BRD_TEMP': 4, # Barometric temperature sensor + 'D16_TEMP': 5, # D16(D17) Conductivity sensor temperature value + 'D28_TEMP': 6, # D28(D27) Conductivity sensor temperature value + 'D30_TEMP': 7, # D30(D29) Conductivity sensor temperature value + 'D44_TEMP': 8, # D44(D43) Conductivity sensor temperature value + 'D75_TEMP': 9, # D75(D74) Conductivity sensor temperature value + 'D99_TEMP': 10, # D98(D99) Conductivity sensor temperature value + 'D4_AVG_TEMP': 11, # D4 Filtered value + 'D50_AVG_TEMP': 12, # D50 Filtered value + 'D28_AVG_TEMP': 13, # D28 Filtered value + 'D30_AVG_TEMP': 14, # D30 Filtered value + 'D99_AVG_TEMP': 15, # D99 Filtered value + 'D9_TEMP': 16, # D9 Pressure sensor temperature value + 'D66_TEMP': 17, # D66 Pressure sensor temperature value + 'D51_TEMP': 18, # D51 Pressure sensor temperature value + 'D18_TEMP': 19, # D18 Pressure sensor temperature value + 'D41_TEMP': 20, # D41 Pressure sensor temperature value + 'D87_TEMP': 21, # D87 Pressure sensor temperature value + 'NUM_OF_TEMP_SENSORS': 22, # Number of Temperature Sensors + } + else: + members = { + 'D1_TEMP': 0, # Heat exchanger Inlet temperature sensor + 'D78_TEMP': 1, # Heat exchanger Outlet temperature sensor + 'D4_TEMP': 2, # Hydraulics primary heater temperature sensor + 'D50_TEMP': 3, # Trimmer heater temperature sensor + 'BRD_TEMP': 4, # Barometric temperature sensor + 'D16_TEMP': 5, # D16(D17) Conductivity sensor temperature value + 'D28_TEMP': 6, # D28(D27) Conductivity sensor temperature value + 'D30_TEMP': 7, # D30(D29) Conductivity sensor temperature value + 'D44_TEMP': 8, # D44(D43) Conductivity sensor temperature value + 'D75_TEMP': 9, # D75(D74) Conductivity sensor temperature value + 'D4_AVG_TEMP': 10, # D4 Filtered value + 'D50_AVG_TEMP': 11, # D50 Filtered value + 'D28_AVG_TEMP': 12, # D28 Filtered value + 'D30_AVG_TEMP': 13, # D30 Filtered value + 'D9_TEMP': 14, # D9 Pressure sensor temperature value + 'D66_TEMP': 15, # D66 Pressure sensor temperature value + 'D51_TEMP': 16, # D51 Pressure sensor temperature value + 'D18_TEMP': 17, # D18 Pressure sensor temperature value + 'D41_TEMP': 18, # D41 Pressure sensor temperature value + 'NUM_OF_TEMP_SENSORS': 19, # Number of Temperature Sensors + } + created_enum = DialinEnum('DDTemperatureSensorNames', members) + + # Add aliases + extend_enum(created_enum, 'FIRST_PRESSURE_SENSOR', created_enum.D9_TEMP.value) + extend_enum(created_enum, 'LAST_PRESSURE_SENSOR', created_enum.D87_TEMP.value if GlobalVariables().HW_BETA_1_9 == True else created_enum.D41_TEMP.value) + extend_enum(created_enum, 'FIRST_CONDUCTIVITY_SENSOR', created_enum.D16_TEMP.value) + extend_enum(created_enum, 'LAST_CONDUCTIVITY_SENSOR', created_enum.D99_TEMP.value if GlobalVariables().HW_BETA_1_9 == True else created_enum.D75_TEMP.value) + + # Add aliases to be searchable (listed when pressed TAB) + created_enum._member_names_.append('FIRST_PRESSURE_SENSOR') + created_enum._member_names_.append('LAST_PRESSURE_SENSOR') + created_enum._member_names_.append('FIRST_CONDUCTIVITY_SENSOR') + created_enum._member_names_.append('LAST_CONDUCTIVITY_SENSOR') + + return created_enum + + + def _create_dd_valve_names(self): + members = { + 'D14_VALV': 0, # Valve Hydraulics Outlet (D14) + 'D52_VALV': 1, # Valve Thermal Disinfect (D52) + 'D8_VALV': 2, # Valve Hydraulics Bypass (D8) + 'D54_VALV': 3, # Valve Rinse Port (D54) + 'D53_VALV': 4, # Valve Drain (D53) + 'D34_VALV': 5, # Valve Dialyzer Bypass (D34) + 'D64_VALV': 6, # Valve Purge 1 (D64) + 'D31_VALV': 7, # Valve Pressure Test (D31) + 'D65_VALV': 8, # Valve DryBcarb Inlet (D65) + 'D35_VALV': 9, # Valve Dialyzer Inlet (D35) + 'D40_VALV': 10, # Valve Dialyzer Outlet (D40) + 'D47_VALV': 11, # Valve Dialysate Out Purge 2 (D47) + 'D3_VALV': 12, # Valve Hydraulics Inlet (D3) + 'D80_VALV': 13, # Valve Dry Bicarb (D80) + 'D81_VALV': 14, # Valve De-scaler (D81) + 'RSRVD_SPACE1': 15, # This space has been reserved + 'D23_VALV': 16, # Balancing chamber Valve 1 (D23) + 'D19_VALV': 17, # Balancing chamber Valve 2 (D19) + 'D25_VALV': 18, # Balancing chamber Valve 3 (D25) + 'D21_VALV': 19, # Balancing chamber Valve 4 (D21) + 'D24_VALV': 20, # Balancing chamber Valve 5 (D24) + 'D20_VALV': 21, # Balancing chamber Valve 6 (D20) + 'D26_VALV': 22, # Balancing chamber Valve 7 (D26) + 'D22_VALV': 23, # Balancing chamber Valve 8 (D22) + 'D79_PMP_VALV': 24, # D79 pump mapped to Spare Valve 0 + 'D83_VALV': 25, # D83 De-scaler Valve mapped to Spare Valve 1 + 'D91_VALV': 26, # D91 De-scaler Valve mapped to Spare Valve 2 + 'SPARE3_VALV': 27, # Spare Valve 3 + 'SPARE4_VALV': 28, # Spare Valve 4 + 'SPARE5_VALV': 29, # Spare Valve 5 + 'D100_VALV': 30, # D100 De-scaler Valve mapped to Spare Valve 6 + 'SPARE7_VALV': 31, # Spare Valve 7 + 'NUM_OF_DD_VALVES': 32, # Number of Valves for the DD + } + return unique(DialinEnum('DDValveNames', members)) + + + def _create_dd_monitored_voltages(self): + members = { + 'MONITORED_LINE_1_2V': 0, # Processor voltage (1.2V) + 'MONITORED_LINE_3_3V': 1, # Logic voltage (3.3V) + 'MONITORED_LINE_5V_LOGIC': 2, # Logic voltage (5V) + 'MONITORED_LINE_24V_1': 3, # Actuators voltage (24V) + 'MONITORED_LINE_24V_2': 4, # Actuators regen voltage (24V) + 'MONITORED_LINE_FPGA_VCC_V': 5, # FPGA Vcc (3V) + 'MONITORED_LINE_FPGA_AUX_V': 6, # FPGA Vaux (3V) + 'MONITORED_LINE_FPGA_PVN_V': 7, # FPGA Vpvn (1V) + 'NUM_OF_MONITORED_VOLTAGE_LINES': 8, # Number of TD operation modes + } + return unique(DialinEnum('DDMonitoredVoltages', members)) + + + + # ================================================== Enum Creators: Support ================================================== + def _create_dd_balancing_chamber_states(self): + members = { + 'BAL_CHAMBER_STATE_START': 0, # Initial state of balancing chamber + 'BAL_CHAMBER_STATE1_FILL_START': 1, # Balancing chamber state 1 fill start state + 'BAL_CHAMBER_STATE1_BICARB_ACID_DOSING_CNTRL': 2, # Balancing Chamber state 1 Bicarb and acid dosing control state + 'BAL_CHAMBER_STATE1_FILL_END': 3, # Balancing Chamber state 1 fill end state + 'BAL_CHAMBER_STATE2_FILL_START': 4, # Balancing chamber state 2 fill start state + 'BAL_CHAMBER_STATE2_BICARB_ACID_DOSING_CNTRL': 5, # Balancing Chamber state 2 Bicarb and acid dosing control state + 'BAL_CHAMBER_STATE2_FILL_END': 6, # Balancing Chamber state 2 fill end state + 'NUM_OF_BAL_CHAMBER_EXEC_STATES': 7, # Number of balancing chamber states + } + return unique(DialinEnum('DDBalancingChamberStates', members)) + + + def _create_dd_balancing_chamber_switch_states(self): + members = { + 'BAL_CHAMBER_SW_STATE1': 0, # Balancing chamber switching state 1 (V2,V5 and V3, V8 open, rest closed) + 'BAL_CHAMBER_SW_STATE2': 1, # Balancing chamber switching state 2 ( V1,V6 and V4, V7 open, rest closed) + 'NUM_OF_BAL_CHAMBER_SW': 2, # Number of balancing chamber states + } + return unique(DialinEnum('DDBalancingChamberSwitchStates', members)) + + + def _create_dd_blood_leak_states(self): + members = { + 'BLOOD_LEAK_WAIT_FOR_POST_STATE': 0, # + 'BLOOD_LEAK_CHECK_SET_POINT_STATE': 1, # + 'BLOOD_LEAK_INIT_STATE': 2, # + 'BLOOD_LEAK_CHECK_ZERO_AND_SELF_TEST_STATE': 3, # + 'BLOOD_LEAK_VERIFY_INTENSITY_AFTER_ZEROING_STATE': 4, # + 'BLOOD_LEAK_NORMAL_STATE': 5, # + 'BLOOD_LEAK_RECOVER_BLOOD_DETECT_STATE': 6, # + 'NUM_OF_BLOOD_LEAK_STATES': 7, # Number of blood leak states + } + return unique(DialinEnum('DDBloodLeakStates', members)) + + + def _create_dd_concentrate_pump_attributes(self): + members = { + 'CURRENT_STATE': 0, # Current State Concentrate Pump Attribute + 'CURRENT_SET_SPEED': 1, # Current Set Speed Concentrate Pump Attribute + 'MEASURED_SPEED': 2, # Measured Speed Concentrate Pump Attribute + 'TARGET_SPEED': 3, # Target Speed Concentrate Pump Attribute + 'PULSE_US': 4, # Hall Sensor Pulse Width (in micro seconds) Concentrate Pump Attribute + 'TARGET_REV_COUNT': 5, # Target Revolutions Concentrate Pump Attribute + 'MEASURED_REV_COUNT': 6, # Measured Revolutions Concentrate Pump Attribute + 'PARKED': 7, # Parked Concentrate Pump Attribute + 'PARK_FAULT': 8, # Park Fault Concentrate Pump Attribute + 'NUM_OF_D10_D11_CONCENTRATE_PUMP_ATTRIBUTES': 9, # Number of Acid (D11) and Bicarbonate (D10) Concentrate Pump Attributes + } + return unique(DialinEnum('DDConcentratePumpAttributes', members)) + + + def _create_dd_concentrate_pump_states(self): + members = { + 'CONCENTRATE_PUMP_OFF_STATE': 0, # Concentrate Pump Off State + 'CONCENTRATE_PUMP_RAMP_TO_TARGET_SPEED_STATE': 1, # Ramp to Target Speed Concentrate Pump State + 'CONCENTRATE_PUMP_CONTROL_TARGET_SPEED_STATE': 2, # Control Target Speed Concentrate Pump State + 'NUM_OF_CONCENTRATE_PUMP_STATES': 3, # Number of Concentrate Pump States + } + return unique(DialinEnum('DDConcentratePumpStates', members)) + + + def _create_dd_dialysate_pump_attributes(self): + members = { + 'TARGET_RPM': 0, # Target RPM Dialysate Pump Attribute + 'MEASURED_SPEED': 1, # Measured Speed Dialysate Pump Attribute + 'CURRENT_SPEED': 2, # Current Speed Dialysate Pump Attribute + 'STATE': 3, # State to command Dialysate Pump Attribute + 'TARGET_PRESSURE': 4, # Target Pressure Dialysate Pump Attribute + 'MEASURED_PRESSURE': 5, # Measured Pressure Dialysate Pump Attribute + 'MEASURED_CURRENT': 6, # Measured Current Dialysate Pump Attribute + 'CONTROL': 7, # Pump Run/Stop Control Pump Attribute + 'DIRECTION_ERROR_COUNT': 8, # Direction Error Count Dialysate Pump Attribute + 'MEASURED_DIRECTION': 9, # Measured Direction Dialysate Pump Attribute + 'NUM_OF_DIALYSATE_PUMP_ATTRIBUTES': 10, # Number of Dialysate Pump Attributes + } + return unique(DialinEnum('DDDialysatePumpAttributes', members)) + + + def _create_dd_dialysate_pump_states(self): + members = { + 'DIALYSATE_PUMP_OFF_STATE': 0, # Dialysate Pump Off State + 'DIALYSATE_PUMP_RAMP_UP_STATE': 1, # Dialysate Pump Ramp Up State + 'DIALYSATE_PUMP_CONTROL_TO_TARGET_STATE': 2, # Dialysate Pump Control to Target State + 'NUM_OF_DIALYSATE_PUMP_STATES': 3, # Number of Dialysate Pump States + } + return unique(DialinEnum('DDDialysatePumpsStates', members)) + + + def _create_dd_heater_start_stop(self): + return unique(DialinEnum('DDHeaterStartStop', {'STOP': 0, 'START': 1})) + + + def _create_dd_heater_attributes(self): + members = { + 'HEAT_DUTY_CYCLE': 0, # Heat Duty Cycle Attribute for Heaters + 'HEAT_TARGET_TEMP': 1, # Target Temperature Attribute for Heaters + 'HEAT_STATE': 2, # State to command Attribute for Heaters + 'DUTY_CYCLE_COUNT': 3, # Duty Cycle Count Attribute for Heaters + 'PWM_PERIOD': 4, # Pulse Width Modulation Attribute for Heaters + 'ADJUSTED_TARGET_TEMP': 5, # Adjusted Target Temperature Attribute for Heaters + 'TARGET_TEMP_TD': 6, # Target Temperature Attribute for Heaters + 'NUM_OF_DD_HEATER_ATTRIBUTES': 7, # Number of Heater Attributes + } + return unique(DialinEnum('DDHeaterAttributes', members)) + + + def _create_dd_heater_exec_states(self): + members = { + 'HEATER_EXEC_STATE_OFF': 0, # Heater Execution Off State + 'HEATER_EXEC_STATE_RAMP_TO_TARGET': 1, # Heater Execution Ramp to Target State + 'HEATER_EXEC_STATE_CONTROL_TO_TARGET': 2, # Heater Execution Control to Target State + 'HEATER_EXEC_STATE_CONTROL_TO_DISINFECT_TARGET': 3, # Heater Execution Control to Disinfection State + 'NUM_OF_HEATERS_EXEC_STATE': 4, # Number of Heater Execution States + } + return unique(DialinEnum('DDHeaterExecState', members)) + + + def _create_dd_piston_pump_attributes(self): + members = { + 'CONTROL_STATE': 0, # Control State for the Piston Pumps + 'SW_COUNTER': 1, # Software counter attribute for the Piston Pumps + 'CYCLE_COUNTER': 2, # Cycle Counter for the Piston Pumps + 'NUM_OF_PISTON_PUMP_ATTRIBUTES': 3, # Number of Piston Pump Attributes + } + return unique(DialinEnum('DDPistonPumpAttributes', members)) + + + def _create_dd_valve_states(self): + members = { + 'VALVE_STATE_CLOSED': 0, # Valve Closed State + 'VALVE_STATE_OPEN': 1, # Valve Open State + } + return unique(DialinEnum('DDValveStates', members)) + + + +# ================================================== Creates a singleton ================================================== +dd_enum_repository = DD_Defs() + +# Attach listener to update function +test_config_change.add_listener(dd_enum_repository.update_enums)