Index: leahi_dialin/common/dd_defs.py =================================================================== diff -u -r27cd8e0e7b47617083e8c12f73306f0ba648e687 -r47f0a02ea1c25f2d9b3f9e7a0f3ac722d4f53a7b --- leahi_dialin/common/dd_defs.py (.../dd_defs.py) (revision 27cd8e0e7b47617083e8c12f73306f0ba648e687) +++ leahi_dialin/common/dd_defs.py (.../dd_defs.py) (revision 47f0a02ea1c25f2d9b3f9e7a0f3ac722d4f53a7b) @@ -450,7 +450,18 @@ 'NUM_OF_PISTON_PUMPS': [], } +@unique +class DDSubstitutionPumpNames(DialinEnum): + D92_PUMP = 0 # HDF Substitution pump + NUM_OF_SUB_PUMPS = 1 # Number of substituion pumps +DDSubstitutionPumpNames._str_list = { + # Official Name : Accepted strings + 'D92_PUMP': ['d92', 'sub pump'], + 'NUM_OF_SUB_PUMPS': [], +} + + @unique class DDPressureSensorNames(DialinEnum): D9_PRES = 0 # Hydraulics outlet pressure (PHo/Pn) @@ -491,13 +502,14 @@ D28_AVG_TEMP = 14 # D28 Filtered value D30_AVG_TEMP = 15 # D30 Filtered value D78_AVG_TEMP = 16 # D78 Filtered value - D9_TEMP = 17 # D9 Pressure sensor temperature value - D66_TEMP = 18 # D66 Pressure sensor temperature value - D51_TEMP = 19 # D51 Pressure sensor temperature value - D18_TEMP = 20 # D18 Pressure sensor temperature value - D41_TEMP = 21 # D41 Pressure sensor temperature value - D87_TEMP = 22 # D87 Pressure sensor temperature value - NUM_OF_TEMP_SENSORS = 23 # Number of Temperature Sensors + D1_AVG_TEMP = 17 # D1 Filtered value + D9_TEMP = 18 # D9 Pressure sensor temperature value + D66_TEMP = 19 # D66 Pressure sensor temperature value + D51_TEMP = 20 # D51 Pressure sensor temperature value + D18_TEMP = 21 # D18 Pressure sensor temperature value + D41_TEMP = 22 # D41 Pressure sensor temperature value + D87_TEMP = 23 # D87 Pressure sensor temperature value + NUM_OF_TEMP_SENSORS = 24 # Number of Temperature Sensors # Aliases FIRST_PRESSURE_SENSOR = D9_TEMP @@ -985,3 +997,35 @@ 'CANCELLATION_MODE_WATER': ['water'], 'NUM_OF_CANCELLATION_MODES': [], } + + +@unique +class DDSubstitutionPumpAttributes(DialinEnum): + TARGET_SPEED = 0 # Target RPM Substitution Pump Attribute + CURRENT_SPEED = 1 # Current Speed Substitution Pump Attribute + STATE = 2 # State to command Substitution Pump Attribute + MEASURED_SPEED = 3 # Measured Speed Substitution Pump Attribute + NUM_OF_DIALYSATE_PUMP_ATTRIBUTES = 4 # Number of Substitution Pump Attributes + +DDSubstitutionPumpAttributes._str_list = { + # Official Name : Accepted strings + 'TARGET_SPEED': ['target rp,'], + 'CURRENT_SPEED': ['current speed'], + 'STATE': ['state'], + 'MEASURED_SPEED': ['measured speed'], + 'NUM_OF_DIALYSATE_PUMP_ATTRIBUTES': [], +} + + +@unique +class DDConductivityResistanceAttributes(DialinEnum): + RAW_RESISTANCE = 0 # Raw Conductivity resistance Attribute + RTD_RESISTANCE = 1 # raw RTD resistance Attribute + NUM_OF_RESISTANCE_ATTRIBUTES = 2 # Number of conductivity sensor Attributes + +DDConductivityResistanceAttributes._str_list = { + # Official Name : Accepted strings + 'RAW_RESISTANCE': ['cond resistance,'], + 'RTD_RESISTANCE': ['rtd resistance'], + 'NUM_OF_RESISTANCE_ATTRIBUTES': [], +} \ No newline at end of file