Index: leahi_dialin/common/test_config_defs.py =================================================================== diff -u -r5c7add17cecb0528db91b9c805c95f9372dc341b -r66ca4d7e28f9a008813bc7bca92dbd98616a840b --- leahi_dialin/common/test_config_defs.py (.../test_config_defs.py) (revision 5c7add17cecb0528db91b9c805c95f9372dc341b) +++ leahi_dialin/common/test_config_defs.py (.../test_config_defs.py) (revision 66ca4d7e28f9a008813bc7bca92dbd98616a840b) @@ -7,8 +7,8 @@ # # @file test_config_defs.py # -# @author (last) Dara Navaei -# @date (last) 16-Aug-2023 +# @author (last) Zoltan Miskolci +# @date (last) 21-Jan-2026 # @author (original) Dara Navaei # @date (original) 24-Apr-2023 # @@ -20,15 +20,24 @@ @unique class DDFPTestConfigOptions(DialinEnum): - TEST_CONFIG_DISABLE_BC_PRES_ALARM = 0 # Test configuration disabling BC pressure alarms - # TEST_CONFIG_BETA_HW = 1 # Test configuration using Beta Hardware - TEST_CONFIG_ENABLE_DRY_BICART_FILL = 1 # Test configuration disabling Dry Bicart fill check - TEST_CONFIG_ENABLE_4WIRE_RINSE_PUMP = 2 # Test configuration Enabling 4 wire rinse pump - TEST_CONFIG_SKIP_FILTERS_FLUSH = 3 # Test configuration to skip filter flush - NUM_OF_TEST_CONFIGS = 4 # Number of Test Configs + TEST_CONFIG_DD_FP_ENABLE_BETA_1_HW = 0 # (DD & FP) Test configuration using Beta 1 Hardware + TEST_CONFIG_DD_DISABLE_BC_PRES_ALARM = 1 # (DD) Test configuration disabling BC pressure alarms + TEST_CONFIG_DD_ENABLE_DRY_BICARB = 2 # (DD) Test configuration enable Dry Bicarb usage + TEST_CONFIG_DD_ENABLE_D79_PWM_CONTROL = 3 # (DD) Test configuration to switch to PWM control for D79 + TEST_CONFIG_FP_SKIP_PRE_GEN_FLUSH = 4 # (FP) Test configuration to skip pre-gen flush + TEST_CONFIG_DD_ENABLE_DIENER_1000_PUMP = 5 # (DD) Test configuration to use Diener 1000 pump for D48 + TEST_CONFIG_DD_ENABLE_SPENT_CHAMBER_H_FILL = 6 # (DD) Test configuration to enable Chamber H Fill + TEST_CONFIG_DD_DISABLE_CONDUCTIVITY_ALARMS = 7 # (DD) Test configuration to disable DD conductivity alarms + TEST_CONFIG_FP_DISABLE_CONDUCTIVITY_ALARMS = 8 # (FP) Test configuration to disable FP conductivity alarms + TEST_CONFIG_DD_ENABLE_DOSING_OPEN_LOOP_CONTROL = 9 # (DD) Test configuration to switch to open loop control for concentrate dosing + TEST_CONFIG_DD_ENABLE_UF_TEMP_COMP = 10 # (DD) Test configuration to enable Ultrafiltration temperature compensation + TEST_CONFIG_DD_RUN_SOLO = 11 # (DD) Test configuration to run DD alone without the other subsystems + TEST_CONFIG_DD_FP_ENABLE_BETA_2_0_HW = 12 # (DD) Test configuration to run DD alone without the other subsystems + NUM_OF_TEST_CONFIGS = 13 # Number of Test Configs +DDFPTestConfigOptions._str_list = {} @unique class TDTestConfigOptions(DialinEnum): - TEST_CONFIG_FIRST = 0 # First test configuration (placeholder) + TEST_CONFIG_ENABLE_BETA_1_HW = 0 # Test configuration using Beta 1 Hardware NUM_OF_TEST_CONFIGS = 1 # Number of Test Configs - +TDTestConfigOptions._str_list = {}