Index: leahi_dialin/common/test_config_defs.py =================================================================== diff -u -r62640bb1dfcb4279d31719ca933c3ce69bfb46be -reb312be9dab95907142103419bc1804713789e8d --- leahi_dialin/common/test_config_defs.py (.../test_config_defs.py) (revision 62640bb1dfcb4279d31719ca933c3ce69bfb46be) +++ leahi_dialin/common/test_config_defs.py (.../test_config_defs.py) (revision eb312be9dab95907142103419bc1804713789e8d) @@ -20,25 +20,25 @@ @unique class DDFPTestConfigOptions(DialinEnum): - TEST_CONFIG_DD_FP_ENABLE_BETA_1_HW = 0 # (DD & FP) Test configuration using Beta 1 Hardware - TEST_CONFIG_DD_DISABLE_BC_PRES_ALARM = 1 # (DD) Test configuration disabling BC pressure alarms - TEST_CONFIG_DD_ENABLE_DRY_BICARB = 2 # (DD) Test configuration enable Dry Bicarb usage - TEST_CONFIG_DD_ENABLE_D79_PWM_CONTROL = 3 # (DD) Test configuration to switch to PWM control for D79 - TEST_CONFIG_FP_SKIP_PRE_GEN_FLUSH = 4 # (FP) Test configuration to skip pre-gen flush - TEST_CONFIG_DD_ENABLE_DIENER_1000_PUMP = 5 # (DD) Test configuration to use Diener 1000 pump for D48 - TEST_CONFIG_DD_ENABLE_SPENT_CHAMBER_H_FILL = 6 # (DD) Test configuration to enable Chamber H Fill - TEST_CONFIG_DD_DISABLE_CONDUCTIVITY_ALARMS = 7 # (DD) Test configuration to disable DD conductivity alarms - TEST_CONFIG_FP_DISABLE_CONDUCTIVITY_ALARMS = 8 # (FP) Test configuration to disable FP conductivity alarms - TEST_CONFIG_DD_ENABLE_DOSING_OPEN_LOOP_CONTROL = 9 # (DD) Test configuration to switch to open loop control for concentrate dosing - TEST_CONFIG_DD_ENABLE_UF_TEMP_COMP = 10 # (DD) Test configuration to enable Ultrafiltration temperature compensation - TEST_CONFIG_DD_RUN_SOLO = 11 # (DD) Test configuration to run DD alone without the other subsystems - TEST_CONFIG_DD_FP_ENABLE_BETA_2_0_HW = 12 # (DD) Test configuration to run DD alone without the other subsystems - TEST_CONFIG_DD_DRY_BICART_TEST = 13 # (DD) Test configuration to test drybicart initial fill from pre-gen - NUM_OF_TEST_CONFIGS = 14 # Number of Test Configs + TEST_CONFIG_DD_FP_ENABLE_BETA_1_HW = 0 # (DD & FP) Test configuration using Beta 1.0 Hardware + TEST_CONFIG_DD_FP_ENABLE_BETA_2_0_HW = 1 # (DD & FP) Test configuration using Beta 2.0 Hardware + TEST_CONFIG_DD_DISABLE_BC_PRES_ALARM = 2 # (DD) Test configuration disabling BC pressure alarms + TEST_CONFIG_DD_ENABLE_DRY_BICARB = 3 # (DD) Test configuration enable Dry Bicarb usage + TEST_CONFIG_FP_SKIP_PRE_GEN_FLUSH = 4 # (FP) Test configuration to skip pre-gen flush + TEST_CONFIG_DD_ENABLE_DIENER_1000_PUMP = 5 # (DD) Test configuration to use Diener 1000 pump for D48 + TEST_CONFIG_DD_ENABLE_SPENT_CHAMBER_H_FILL = 6 # (DD) Test configuration to enable Chamber H Fill + TEST_CONFIG_DD_DISABLE_CONDUCTIVITY_ALARMS = 7 # (DD) Test configuration to disable DD conductivity alarms + TEST_CONFIG_FP_DISABLE_CONDUCTIVITY_ALARMS = 8 # (FP) Test configuration to disable FP conductivity alarms + TEST_CONFIG_DD_ENABLE_DOSING_OPEN_LOOP_CONTROL = 9 # (DD) Test configuration to switch to open loop control for concentrate dosing + TEST_CONFIG_DD_ENABLE_UF_TEMP_COMP = 10 # (DD) Test configuration to enable Ultrafiltration temperature compensation + TEST_CONFIG_DD_RUN_SOLO = 11 # (DD) Test configuration to run DD alone without the other subsystems + TEST_CONFIG_DD_DRY_BICART_TEST = 12 # (DD) Test configuration to test drybicart initial fill from pre-gen + NUM_OF_TEST_CONFIGS = 13 # Number of Test Configs DDFPTestConfigOptions._str_list = {} @unique class TDTestConfigOptions(DialinEnum): - TEST_CONFIG_ENABLE_BETA_1_HW = 0 # Test configuration using Beta 1 Hardware - NUM_OF_TEST_CONFIGS = 1 # Number of Test Configs + TEST_CONFIG_ENABLE_BETA_1_HW = 0 # Test configuration using Beta 1 Hardware + TEST_CONFIG_SKIP_BLOOD_PRIME = 1 # Test configuration to skip blood priming + NUM_OF_TEST_CONFIGS = 2 # Number of Test Configs TDTestConfigOptions._str_list = {}