Index: leahi_dialin/common/test_config_defs.py =================================================================== diff -u -r88cf855ac0d2a8612f610d35a96ac0cd5accf74c -r66ca4d7e28f9a008813bc7bca92dbd98616a840b --- leahi_dialin/common/test_config_defs.py (.../test_config_defs.py) (revision 88cf855ac0d2a8612f610d35a96ac0cd5accf74c) +++ leahi_dialin/common/test_config_defs.py (.../test_config_defs.py) (revision 66ca4d7e28f9a008813bc7bca92dbd98616a840b) @@ -23,16 +23,17 @@ TEST_CONFIG_DD_FP_ENABLE_BETA_1_HW = 0 # (DD & FP) Test configuration using Beta 1 Hardware TEST_CONFIG_DD_DISABLE_BC_PRES_ALARM = 1 # (DD) Test configuration disabling BC pressure alarms TEST_CONFIG_DD_ENABLE_DRY_BICARB = 2 # (DD) Test configuration enable Dry Bicarb usage - TEST_CONFIG_DD_ENABLE_4WIRE_RINSE_PUMP = 3 # (DD) Test configuration enabling 4 wire rinse pump + TEST_CONFIG_DD_ENABLE_D79_PWM_CONTROL = 3 # (DD) Test configuration to switch to PWM control for D79 TEST_CONFIG_FP_SKIP_PRE_GEN_FLUSH = 4 # (FP) Test configuration to skip pre-gen flush TEST_CONFIG_DD_ENABLE_DIENER_1000_PUMP = 5 # (DD) Test configuration to use Diener 1000 pump for D48 - TEST_CONFIG_DD_ENABLE_D79_PWM_CONTROL = 6 # (DD) Test configuration to switch to PWM control for D79 - TEST_CONFIG_DD_ENABLE_SPENT_CHAMBER_H_FILL = 7 # (DD) Test configuration to enable Chamber H Fill - TEST_CONFIG_DD_DISABLE_CONDUCTIVITY_ALARMS = 8 # (DD) Test configuration to disable DD conductivity alarms - TEST_CONFIG_FP_DISABLE_CONDUCTIVITY_ALARMS = 9 # (FP) Test configuration to disable FP conductivity alarms - TEST_CONFIG_DD_ENABLE_DOSING_OPEN_LOOP_CONTROL = 10 # (DD) Test configuration to switch to open loop control for concentrate dosing - TEST_CONFIG_DD_ENABLE_UF_TEMP_COMP = 11 # (DD) Test configuration to enable Ultrafiltration temperature compensation - NUM_OF_TEST_CONFIGS = 12 # Number of Test Configs + TEST_CONFIG_DD_ENABLE_SPENT_CHAMBER_H_FILL = 6 # (DD) Test configuration to enable Chamber H Fill + TEST_CONFIG_DD_DISABLE_CONDUCTIVITY_ALARMS = 7 # (DD) Test configuration to disable DD conductivity alarms + TEST_CONFIG_FP_DISABLE_CONDUCTIVITY_ALARMS = 8 # (FP) Test configuration to disable FP conductivity alarms + TEST_CONFIG_DD_ENABLE_DOSING_OPEN_LOOP_CONTROL = 9 # (DD) Test configuration to switch to open loop control for concentrate dosing + TEST_CONFIG_DD_ENABLE_UF_TEMP_COMP = 10 # (DD) Test configuration to enable Ultrafiltration temperature compensation + TEST_CONFIG_DD_RUN_SOLO = 11 # (DD) Test configuration to run DD alone without the other subsystems + TEST_CONFIG_DD_FP_ENABLE_BETA_2_0_HW = 12 # (DD) Test configuration to run DD alone without the other subsystems + NUM_OF_TEST_CONFIGS = 13 # Number of Test Configs DDFPTestConfigOptions._str_list = {} @unique