Index: leahi_dialin/common/test_config_defs.py =================================================================== diff -u -rc3f388b1697f7c4d18b2bdc7b3adca988dc293a6 -r5efa17f1320ab27b9942f50375208c75f1756600 --- leahi_dialin/common/test_config_defs.py (.../test_config_defs.py) (revision c3f388b1697f7c4d18b2bdc7b3adca988dc293a6) +++ leahi_dialin/common/test_config_defs.py (.../test_config_defs.py) (revision 5efa17f1320ab27b9942f50375208c75f1756600) @@ -7,8 +7,8 @@ # # @file test_config_defs.py # -# @author (last) Dara Navaei -# @date (last) 16-Aug-2023 +# @author (last) Zoltan Miskolci +# @date (last) 21-Jan-2026 # @author (original) Dara Navaei # @date (original) 24-Apr-2023 # @@ -20,14 +20,20 @@ @unique class DDFPTestConfigOptions(DialinEnum): - TEST_CONFIG_DISABLE_BC_PRES_ALARM = 0 # (DD) Test configuration disabling BC pressure alarms - TEST_CONFIG_ENABLE_BETA_1_9_HW = 1 # (DD & FP) Test configuration using Beta Hardware - TEST_CONFIG_ENABLE_DRY_BICART_FILL = 2 # Test configuration disabling Dry Bicart fill check - TEST_CONFIG_ENABLE_4WIRE_RINSE_PUMP = 3 # Test configuration Enabling 4 wire rinse pump - TEST_CONFIG_SKIP_FILTERS_FLUSH = 4 # (FP) Test configuration to skip filter flush - NUM_OF_TEST_CONFIGS = 5 # Number of Test Configs + TEST_CONFIG_DD_FP_ENABLE_BETA_1_HW = 0 # (DD & FP) Test configuration using Beta 1 Hardware + TEST_CONFIG_DD_DISABLE_BC_PRES_ALARM = 1 # (DD) Test configuration disabling BC pressure alarms + TEST_CONFIG_DD_ENABLE_DRY_BICARB = 2 # (DD) Test configuration enable Dry Bicarb usage + TEST_CONFIG_DD_ENABLE_D79_PWM_CONTROL = 3 # (DD) Test configuration enabling 4 wire rinse pump + TEST_CONFIG_FP_SKIP_PRE_GEN_FLUSH = 4 # (FP) Test configuration to skip pre-gen flush + TEST_CONFIG_DD_ENABLE_DIENER_1000_PUMP = 5 # (DD) Test configuration to use Diener 1000 pump for D48 TEST_CONFIG_DD_ENABLE_SPENT_CHAMBER_H_FILL = 6 # (DD) Test configuration to enable Chamber H Fill + TEST_CONFIG_DD_DISABLE_CONDUCTIVITY_ALARMS = 7 # (DD) Test configuration to disable DD conductivity alarms + TEST_CONFIG_FP_DISABLE_CONDUCTIVITY_ALARMS = 8 # (FP) Test configuration to disable FP conductivity alarms + TEST_CONFIG_DD_ENABLE_DOSING_OPEN_LOOP_CONTROL = 9 # (DD) Test configuration to switch to open loop control for concentrate dosing + TEST_CONFIG_DD_ENABLE_UF_TEMP_COMP = 10 # (DD) Test configuration to enable Ultrafiltration temperature compensation + TEST_CONFIG_DD_RUN_SOLO = 11 # (DD) Test configuration to run DD alone without the other subsystems + NUM_OF_TEST_CONFIGS = 12 # Number of Test Configs @unique class TDTestConfigOptions(DialinEnum): - TEST_CONFIG_ENABLE_BETA_1_9_HW = 0 # Test configuration to switch to HW in development + TEST_CONFIG_ENABLE_BETA_1_HW = 0 # Test configuration using Beta 1 Hardware NUM_OF_TEST_CONFIGS = 1 # Number of Test Configs