Index: leahi_dialin/common/test_config_defs.py =================================================================== diff -u -re16372ac648dd4efca346c889348b08c8653ee17 -rf66c019100e98b49cd94fa0a69951a1a7c952da0 --- leahi_dialin/common/test_config_defs.py (.../test_config_defs.py) (revision e16372ac648dd4efca346c889348b08c8653ee17) +++ leahi_dialin/common/test_config_defs.py (.../test_config_defs.py) (revision f66c019100e98b49cd94fa0a69951a1a7c952da0) @@ -7,8 +7,8 @@ # # @file test_config_defs.py # -# @author (last) Dara Navaei -# @date (last) 16-Aug-2023 +# @author (last) Zoltan Miskolci +# @date (last) 21-Jan-2026 # @author (original) Dara Navaei # @date (original) 24-Apr-2023 # @@ -19,18 +19,23 @@ @unique -class DDTestConfigOptions(DialinEnum): - TEST_CONFIG_DISABLE_BC_PRES_ALARM = 0 # Test configuration disabling BC pressure alarms - TEST_CONFIG_ENABLE_DRY_BICART_FILL = 1 # Test configuration for enabling drybicart fill - NUM_OF_TEST_CONFIGS = 2 # Number of Test Configs +class DDFPTestConfigOptions(DialinEnum): + TEST_CONFIG_DD_FP_ENABLE_BETA_1_HW = 0 # (DD & FP) Test configuration using Beta 1 Hardware + TEST_CONFIG_DD_DISABLE_BC_PRES_ALARM = 1 # (DD) Test configuration disabling BC pressure alarms + TEST_CONFIG_DD_ENABLE_DRY_BICARB = 2 # (DD) Test configuration enable Dry Bicarb usage + TEST_CONFIG_DD_ENABLE_4WIRE_RINSE_PUMP = 3 # (DD) Test configuration enabling 4 wire rinse pump + TEST_CONFIG_FP_SKIP_PRE_GEN_FLUSH = 4 # (FP) Test configuration to skip pre-gen flush + TEST_CONFIG_DD_ENABLE_DIENER_1000_PUMP = 5 # (DD) Test configuration to use Diener 1000 pump for D48 + TEST_CONFIG_DD_ENABLE_D79_PWM_CONTROL = 6 # (DD) Test configuration to switch to PWM control for D79 + TEST_CONFIG_DD_ENABLE_SPENT_CHAMBER_H_FILL = 7 # (DD) Test configuration to enable Chamber H Fill + TEST_CONFIG_DD_DISABLE_CONDUCTIVITY_ALARMS = 8 # (DD) Test configuration to disable DD conductivity alarms + TEST_CONFIG_FP_DISABLE_CONDUCTIVITY_ALARMS = 9 # (FP) Test configuration to disable FP conductivity alarms + TEST_CONFIG_DD_ENABLE_DOSING_OPEN_LOOP_CONTROL = 10 # (DD) Test configuration to switch to open loop control for concentrate dosing + TEST_CONFIG_DD_ENABLE_UF_TEMP_COMP = 11 # (DD) Test configuration to enable Ultrafiltration temperature compensation + TEST_CONFIG_DD_ENABLE_DRY_BICART_FILL = 12 # (DD) Test configuration enable Dry Bicart fill + NUM_OF_TEST_CONFIGS = 13 # Number of Test Configs @unique -class FPTestConfigOptions(DialinEnum): - TEST_CONFIG_BETA_HW = 0 # Test configuration using Beta Hardware - NUM_OF_TEST_CONFIGS = 1 # Number of Test Configs - -@unique class TDTestConfigOptions(DialinEnum): - TEST_CONFIG_FIRST = 0 # First test configuration (placeholder) + TEST_CONFIG_ENABLE_BETA_1_HW = 0 # Test configuration using Beta 1 Hardware NUM_OF_TEST_CONFIGS = 1 # Number of Test Configs -