Index: leahi_dialin/fp/modules/pressure_sensors.py =================================================================== diff -u -r0f08c28544b557b2bbd8c04b10cff284f41e4fb9 -r5b9473d9ca6a66d4d03c509fae6051710895b498 --- leahi_dialin/fp/modules/pressure_sensors.py (.../pressure_sensors.py) (revision 0f08c28544b557b2bbd8c04b10cff284f41e4fb9) +++ leahi_dialin/fp/modules/pressure_sensors.py (.../pressure_sensors.py) (revision 5b9473d9ca6a66d4d03c509fae6051710895b498) @@ -27,12 +27,12 @@ @unique class FPPressureSensorNames(DialinEnum): - M1_PRESSURE_SENSOR_WATER_INLET_PRE_REG = 0 - M3_PRESSURE_SENSOR_WATER_INLET_POST_REG = 1 - P8_PRESSURE_SENSOR_WATER_INLET_PRE_COND = 2 - P13_PRESSURE_SENSOR_PRE_RO_FILTER = 3 - P17_PRESSURE_SENSOR_POST_RO_FILTER = 4 - X1_PRESSURE_SENSOR_PRE_RO_PUMP = 5 + M1_PRES = 0 + M3_PRES = 1 + P8_PRES = 2 + P13_PRES = 3 + P17_PRES = 4 + X1_PRES = 5 class FPPressureSensors(AbstractSubSystem): @@ -56,34 +56,34 @@ self._handler_pressure_sync) self.fp_pressure_timestamp = 0.0 - self.m1_water_inlet_pre_reg_pressure = 0.0 - self.m3_water_inlet_post_reg_pressure = 0.0 - self.p8_water_inlet_pre_cond_pressure = 0.0 - self.p13_pre_ro_filter_pressure = 0.0 - self.p17_post_ro_filter_pressure = 0.0 - self.x1_pre_ro_pump_pressure = 0.0 - self.m1_water_inlet_pre_reg_temp = 0.0 - self.m3_water_inlet_post_reg_temp = 0.0 - self.p8_water_inlet_pre_cond_temp = 0.0 - self.p13_pre_ro_filter_temp = 0.0 - self.p17_post_ro_filter_temp = 0.0 - self.x1_pre_ro_pump_temp = 0.0 + self.m1_pres = 0.0 + self.m3_pres = 0.0 + self.p8_pres = 0.0 + self.p13_pres = 0.0 + self.p17_pres = 0.0 + self.x1_pres = 0.0 + self.m1_pres_temp = 0.0 + self.m3_pres_temp = 0.0 + self.p8_pres_temp = 0.0 + self.p13_pres_temp = 0.0 + self.p17_pres_temp = 0.0 + self.x1_pres_temp = 0.0 @publish([ "fp_pressure_timestamp", - "m1_water_inlet_pre_reg_pressure", - "m3_water_inlet_post_reg_pressure", - "p8_water_inlet_pre_cond_pressure", - "p13_pre_ro_filter_pressure", - "p17_post_ro_filter_pressure", - "x1_pre_ro_pump_pressure", - "m1_water_inlet_pre_reg_temp", - "m3_water_inlet_post_reg_temp", - "p8_water_inlet_pre_cond_temp", - "p13_pre_ro_filter_temp", - "p17_post_ro_filter_temp", - "x1_pre_ro_pump_temp" + "m1_pres", + "m3_pres", + "p8_pres", + "p13_pres", + "p17_pres", + "x1_pres", + "m1_pres_temp", + "m3_pres_temp", + "p8_pres_temp", + "p13_pres_temp", + "p17_pres_temp", + "x1_pres_temp" ]) def _handler_pressure_sync(self, message, timestamp=0.0): """ @@ -120,19 +120,19 @@ pre_pump_temp = struct.unpack('f', bytearray( message['message'][MsgFieldPositions.START_POS_FIELD_12:MsgFieldPositions.END_POS_FIELD_12])) - self.m1_water_inlet_pre_reg_pressure = pre_reg_wi[0] - self.m3_water_inlet_post_reg_pressure = post_reg_wi[0] - self.p8_water_inlet_pre_cond_pressure = pre_cond_wi[0] - self.p13_pre_ro_filter_pressure = pre_ro[0] - self.p17_post_ro_filter_pressure = post_ro[0] - self.x1_pre_ro_pump_pressure = pre_pump[0] + self.m1_pres = pre_reg_wi[0] + self.m3_pres = post_reg_wi[0] + self.p8_pres = pre_cond_wi[0] + self.p13_pres = pre_ro[0] + self.p17_pres = post_ro[0] + self.x1_pres = pre_pump[0] - self.m1_water_inlet_pre_reg_pressure = pre_reg_wi_temp[0] - self.m3_water_inlet_post_reg_pressure = post_reg_wi_temp[0] - self.p8_water_inlet_pre_cond_pressure = pre_cond_wi_temp[0] - self.p13_pre_ro_filter_pressure = pre_ro_temp[0] - self.p17_post_ro_filter_pressure = post_ro_temp[0] - self.x1_pre_ro_pump_temp = pre_pump_temp[0] + self.m1_pres_temp = pre_reg_wi_temp[0] + self.m3_pres_temp = post_reg_wi_temp[0] + self.p8_pres_temp = pre_cond_wi_temp[0] + self.p13_pres_temp = pre_ro_temp[0] + self.p17_pres_temp = post_ro_temp[0] + self.x1_pres_temp = pre_pump_temp[0] self.fp_pressure_timestamp = timestamp