Index: leahi_dialin/ro/modules/boost_pump.py =================================================================== diff -u -rcc62efcf5a2ca1bf566234f8b4447f4fbc8e1ab2 -r8c0c7ee456674a5b9c7c407cc03deee0c23993f2 --- leahi_dialin/ro/modules/boost_pump.py (.../boost_pump.py) (revision cc62efcf5a2ca1bf566234f8b4447f4fbc8e1ab2) +++ leahi_dialin/ro/modules/boost_pump.py (.../boost_pump.py) (revision 8c0c7ee456674a5b9c7c407cc03deee0c23993f2) @@ -26,12 +26,12 @@ class ROPumps(AbstractSubSystem): """ - Treatment Device (RO) Dialin API sub-class for blood-flow related commands. + TReverse Osmosis (RO) Dialin API sub-class for blood-flow related commands. """ def __init__(self, can_interface, logger: Logger): """ - ROBloodFlow constructor + ROPumps constructor """ super().__init__() self.can_interface = can_interface Index: leahi_dialin/ro/modules/levels.py =================================================================== diff -u -r249bfa9ec36c4a35604cc6466c33eaf60c3ff6d8 -r8c0c7ee456674a5b9c7c407cc03deee0c23993f2 --- leahi_dialin/ro/modules/levels.py (.../levels.py) (revision 249bfa9ec36c4a35604cc6466c33eaf60c3ff6d8) +++ leahi_dialin/ro/modules/levels.py (.../levels.py) (revision 8c0c7ee456674a5b9c7c407cc03deee0c23993f2) @@ -28,7 +28,7 @@ class ROLevels(AbstractSubSystem): """ - Dialysate Delivery (RO) Dialin API sub-class for levels related commands. + Reverse Osmosis (RO) Dialin API sub-class for levels related commands. """ def __init__(self, can_interface, logger: Logger): @@ -54,9 +54,9 @@ "floater",]) def _handler_levels_sync(self, message, timestamp=0.0): """ - Handles published heaters message + Handles published levels message - @param message: published heaters data message + @param message: published levels data message @returns none """ self.floater = struct.unpack('i', bytearray( @@ -68,8 +68,8 @@ """ Constructs and sends broadcast time interval. Constraints: - Must be logged into DG. - Given interval must be non-zero and a multiple of the DG general task interval (50 ms). + Must be logged into RO. + Given interval must be non-zero and a multiple of the RO general task interval (50 ms). @param ms: (int) Publish time interval in ms @param reset: (int) 1 to reset a previous override, 0 to override @@ -101,10 +101,10 @@ def cmd_level_status_override(self, level_sensor: int, status: int, reset: int = NO_RESET) -> int: """ Constructs and sends heater duty cycle override command - Must be logged into DG - There must be a minimum flow available for the heaters (FMP for primary and FMD for trimmer) + Must be logged into RO - @param level_sensor the level sensor to override its value (primary, trimmer) (0-1.0 order) + + @param level_sensor the level sensor to override its value @param status the status value to override @param reset: (int) 1 to reset a previous override, 0 to override @returns 1 if successful, zero otherwise Index: leahi_dialin/ro/modules/pressure_sensors.py =================================================================== diff -u -r249bfa9ec36c4a35604cc6466c33eaf60c3ff6d8 -r8c0c7ee456674a5b9c7c407cc03deee0c23993f2 --- leahi_dialin/ro/modules/pressure_sensors.py (.../pressure_sensors.py) (revision 249bfa9ec36c4a35604cc6466c33eaf60c3ff6d8) +++ leahi_dialin/ro/modules/pressure_sensors.py (.../pressure_sensors.py) (revision 8c0c7ee456674a5b9c7c407cc03deee0c23993f2) @@ -26,7 +26,7 @@ class ROPressureSensors(AbstractSubSystem): """ - Treatment Delivery (RO) Dialin API sub-class for pressure related commands. + Reverse Osmosis (RO) Dialin API sub-class for pressure related commands. """ def __init__(self, can_interface, logger: Logger): @@ -113,7 +113,7 @@ # Send message received_message = self.can_interface.send(message) - # If there is contentleahi_dialin.. + # If there is content... if received_message is not None: if reset == RESET: str_res = "reset back to normal. "