Index: configurations/Alarms/Alarms.conf =================================================================== diff -u -rba77d8eac89894bf532d884c2450ff131e228832 -rbcafc1d20046aaf42e7f697f9c33376e0b6b6126 --- configurations/Alarms/Alarms.conf (.../Alarms.conf) (revision ba77d8eac89894bf532d884c2450ff131e228832) +++ configurations/Alarms/Alarms.conf (.../Alarms.conf) (revision bcafc1d20046aaf42e7f697f9c33376e0b6b6126) @@ -111,24 +111,24 @@ ListTitle = TD venous pressure sensor reporting error or not being read successfully [28] -Title = Service Required: Dialysate Device +Title = Low TMP Pressure ListTitle = DD hydraulics outlet pressure sensor reporting error or not being read successfully [29] -Title = Service Required: Dialysate Device +Title = High TMP Pressure ListTitle = DD bibag pressure sensor reporting error or not being read successfully [30] -Title = Service Required: Dialysate Device -ListTitle = DD spent dialysate pressure sensor reporting error or not being read successfully +Title = Self Test: Venous Air Detector +ListTitle = TD venous air bubble detector self-test failure [31] -Title = Service Required: Dialysate Device -ListTitle = DD fresh dialysate pressure sensor reporting error or not being read successfully +Title = MAX Blood Prime Pause Time +ListTitle = Blood Prime pause approaching timeout (> 4 min). [32] -Title = Service Required: Dialysate Device -ListTitle = DD transmembrane sensor reporting error or not being read successfully +Title = MAX Blood Prime Pause Time Reached +ListTitle = Blood Prime pause timeout reached (> 5 min). [33] Title = Service Required: Hemodialysis Device @@ -232,7 +232,7 @@ [58] Title = Service Required: Dialysate Device -ListTitle = DD barometric sensor not being read successfully +ListTitle = DD Balancing chamber fill timeout error [59] Title = Service Required: Dialysate Device @@ -371,8 +371,8 @@ ListTitle = DD Bicarb chamber fill timeout error [93] -Title = -ListTitle = +Title = Service Required: Dialysate Device +ListTitle = DD D79 rinse pump commanded vs measured speed out of tolerance [94] Title = Service Required: Dialysate Device @@ -600,7 +600,7 @@ [150] Title = Service Required: FP Device -ListTitle = FP RO pump flow out of range +ListTitle = FP inlet temperature too high during filters flush [151] Title = FP: Filter Health @@ -654,3 +654,99 @@ Title = low Permeate flow ListTitle = Permeate flow is too low from set target flow rate +[164] +Title = low inlet pressure +ListTitle = Inlet pressure is too low + +[165] +Title = Blood Pump Stopped: Venous Air Detector +ListTitle = Air trap lowering timeout during treatment + +[166] +Title = Service Required: Hemodialysis Device +ListTitle = TD syringe pump self-test failure alarm + +[167] +Title = Service Required: Hemodialysis Device +ListTitle = TD syringe pump is running while the BP is off + +[168] +Title = Service Required: Hemodialysis Device +ListTitle = TD syringe pump ADC error + +[169] +Title = Service Required: Hemodialysis Device +ListTitle = TD syringe pump fault reported by FPGA + +[170] +Title = Service Required: Hemodialysis Device +ListTitle = TD syringe pump DAC write failure + +[171] +Title = Service Required: Hemodialysis Device +ListTitle = TD syringe pump speed check error + +[172] +Title = Service Required: Hemodialysis Device +ListTitle = TD syringe pump volume check error + +[173] +Title = Service Required: Hemodialysis Device +ListTitle = TD syringe pump over travel error + +[174] +Title = Service Required: Hemodialysis Device +ListTitle = TD syringe pump not stopped in off state error + +[175] +Title = Service Required: Hemodialysis Device +ListTitle = TD syringe pump direction (from encoder) error + +[176] +Title = Service Required: Hemodialysis Device +ListTitle = TD syringe pump direction (from controller) error + +[177] +Title = Heparin Syringe Empty +ListTitle = TD syringe empty alarm + +[178] +Title = Blood Stopped: Syringe Not Detected +ListTitle = TD syringe pump syringe removed alarm + +[179] +Title = Service Required: Hemodialysis Device +ListTitle = TD syringe pump stall alarm + +[180] +Title = Service Required: Hemodialysis Device +ListTitle = TD heparin force sensor invalid calibration record + +[181] +Title = Syringe Detected +ListTitle = TD syringe detected alarm + +[182] +Title = Not Enough Heparin +ListTitle = TD syringe pump not enough Heparin alarm + +[183] +Title = Heparin Pump Occlusion +ListTitle = TD syringe pump occlusion alarm + +[184] +Title = Service Required: Hemodialysis Device +ListTitle = TD syringe pump timeout alarm + +[185] +Title = Service Required: FP Device +ListTitle = FP conductivity sensor (P9) located in inlet water path reporting error or not being read successfully + +[186] +Title = Service Required: FP Device +ListTitle = FP conductivity sensor (P18) located in inlet water path reporting error or not being read successfully + +[187] +Title = Air Pump Stall Detected +ListTitle = Air pump stall detected during treatment +