Index: configurations/Instructions/Instructions.conf =================================================================== diff -u -r3de6637d2d7d4b3610c4e1bd550552c53f829764 -ra05b0d3fe542e3281014a64c04501d6b45ca92a7 --- configurations/Instructions/Instructions.conf (.../Instructions.conf) (revision 3de6637d2d7d4b3610c4e1bd550552c53f829764) +++ configurations/Instructions/Instructions.conf (.../Instructions.conf) (revision a05b0d3fe542e3281014a64c04501d6b45ca92a7) @@ -16,6 +16,12 @@ # [] # "Title" = # <Instruction step> = <image.png> +# Rich Text is supported: +# ex: +# <b></b> - bold +# <i></i> - italic +# <u> - underlined text +# <$HEX>text</$> - color text // Ex. <$2268FF>TEST</$> - Do not add '0x' to HEX value # ###################################################################################################### [Concentrates] @@ -33,18 +39,18 @@ [Installation^Bloodlines] Title = Install Bloodlines Insert saline line into the first slot. = Installation_Bloodlines_1.png -Insert arterial line into the second slot. = Installation_Bloodlines_2.png -Ensure the venous line is placed in the bubble detector. = Installation_Bloodlines_3.png -Insert the venous line into the third slot. = Installation_Bloodlines_4.png -Connect the arterial and venous bloodlines using the recirculation connector. = Installation_Bloodlines_5.png +Insert <$B53333>arterial</$> line into the second slot. = Installation_Bloodlines_2.png +Ensure the <$2268FF>venous</$> line is placed in the bubble detector. = Installation_Bloodlines_3.png +Insert the <$2268FF>venous</$> line into the third slot. = Installation_Bloodlines_4.png +Connect the <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines using the recirculation connector. = Installation_Bloodlines_5.png [Installation^Pressure Lines and Dialyzer] Title = Install Pressure Lines and Dialyzer -Connect the arterial pressure line to the arterial pressure transducer port. = Installation_CPLD_1.png -Connect the venous pressure line to the venous pressure transducer port. = Installation_CPLD_2.png +Connect the <$B53333>arterial</$> pressure line to the <$B53333>arterial</$> pressure transducer port. = Installation_CPLD_1.png +Connect the <$2268FF>venous</$> pressure line to the <$2268FF>venous</$> pressure transducer port. = Installation_CPLD_2.png Insert dialyzer into the holder and connect the dialysate lines. = Installation_CPLD_3.png Connect the bloodlines to the dialyzer. = Installation_CPLD_4.png -Clamp the venous chamber line. = Installation_CPLD_5.png +Clamp the <$2268FF>venous</$> chamber line. = Installation_CPLD_5.png Clamp the heparin line. = Installation_CPLD_6.png [Installation^Saline] @@ -64,10 +70,10 @@ [Connect] Title = Connect Bloodlines to the Patient -Clamp arterial and venous bloodlines (2 clamps). = Connect_1.png +Clamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines (2 clamps). = Connect_1.png Remove recirculation connector from the bloodlines. = Connect_2.png Connect bloodlines to patient access lines. = Connect_3.png -Unclamp arterial and venous bloodlines (2 clamps). = Connect_4.png +Unclamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines (2 clamps). = Connect_4.png [@Connect] Title = Connect Bloodlines to the Patient @@ -84,18 +90,48 @@ [Blood Return Setup] Title = Blood Return Connection -Clamp arterial bloodlines and disconnect. = Connect_1.png -Connect arterial bloodline to the saline y-connector. = Connect_2.png -Unclamp arterial bloodline and saline y-connector. = Connect_3.png +Clamp <$B53333>arterial</$> bloodlines and disconnect. = Return_Blood_1.png +Connect <$B53333>arterial</$> bloodline to the saline y-connector. = Return_Blood_2.png +Unclamp <$B53333>arterial</$> bloodline and saline y-connector. = Return_Blood_3.png [$Blood Return Setup] Title = Blood Return Connection -Clamp arterial bloodlines and disconnect. = Connect_1.png -Connect arterial bloodline to the substitution line using a sterile connector. = Connect_2.png -Unclamp arterial bloodline and substitution line . = Connect_3.png +Clamp <$B53333>arterial</$> bloodlines and disconnect. +Connect <$B53333>arterial</$> bloodline to the substitution line using a sterile connector. +Unclamp <$B53333>arterial</$> bloodline and substitution line. [Recirculate Set Up] Title = Connect Recirculation Lines +Clamp <$2268FF>venous</$> bloodline and disconnect. +Clamp <$B53333>arterial</$> bloodlines and disconnect from saline y-connector. +Connect <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines using the recirculation connector. +Unclamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines. + +[$Recirculate Set Up] +Title = Connect Recirculation Lines +Clamp <$2268FF>venous</$> bloodline and disconnect. +Clamp <$B53333>arterial</$> and disconnect from the substitution line. +Connect substitution line to the appropriate dilution port. +Connect <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines using the recirculation connector. +Unclamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines. + +[Reconnect To Patient] +Title = Connect Patient Bloodlines +Clamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines. +Remove <$B53333>arterial</$> and <$2268FF>venous</$> line recirculation connector. +Connect <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines to patient access lines. +Unclamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines. + +[$Reconnect To Patient] +Title = Connect Patient Bloodlines +Clamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines. +Remove <$B53333>arterial</$> and <$2268FF>venous</$> line recirculation connector. +Connect <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines to patient access lines. +Unclamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines. + + +[Recirculate Set Up] +Title = Connect Recirculation Lines Clamp venous bloodlines and disconnect. Clamp arterial bloodlines and disconnect from saline y-connector. Connect arterial and venous bloodlines using the recirculation connector.