Index: configurations/Instructions/Instructions.conf =================================================================== diff -u -rc91bfcd184973649be9151a9f54cb176742d3c30 -re112b5d1b628e938fbc38fe98f34d555afd24309 --- configurations/Instructions/Instructions.conf (.../Instructions.conf) (revision c91bfcd184973649be9151a9f54cb176742d3c30) +++ configurations/Instructions/Instructions.conf (.../Instructions.conf) (revision e112b5d1b628e938fbc38fe98f34d555afd24309) @@ -16,6 +16,12 @@ # [] # "Title" = # <Instruction step> = <image.png> +# Rich Text is supported: +# ex: +# <b></b> - bold +# <i></i> - italic +# <u> - underlined text +# <$HEX>text</$> - color text // Ex. <$2268FF>TEST</$> - Do not add '0x' to HEX value # ###################################################################################################### [Concentrates] @@ -33,42 +39,41 @@ [Installation^Bloodlines] Title = Install Bloodlines Insert saline line into the first slot. = Installation_Bloodlines_1.png -Insert arterial line into the second slot. = Installation_Bloodlines_2.png -Ensure the venous line is placed in the bubble detector. = Installation_Bloodlines_3.png -Insert the venous line into the third slot. = Installation_Bloodlines_4.png -Connect the arterial and venous bloodlines using the recirculation connector. = Installation_Bloodlines_5.png +Insert <$B53333>arterial</$> line into the second slot. = Installation_Bloodlines_2.png +Ensure the <$2268FF>venous</$> line is placed in the bubble detector. = Installation_Bloodlines_3.png +Insert the <$2268FF>venous</$> line into the third slot. = Installation_Bloodlines_4.png +Connect the <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines using the recirculation connector. = Installation_Bloodlines_5.png [Installation^Pressure Lines and Dialyzer] Title = Install Pressure Lines and Dialyzer -Connect the arterial pressure line to the arterial pressure transducer port. = Installation_CPLD_1.png -Connect the venous pressure line to the venous pressure transducer port. = Installation_CPLD_2.png +Connect the <$B53333>arterial</$> pressure line to the <$B53333>arterial</$> pressure transducer port. = Installation_CPLD_1.png +Connect the <$2268FF>venous</$> pressure line to the <$2268FF>venous</$> pressure transducer port. = Installation_CPLD_2.png Insert dialyzer into the holder and connect the dialysate lines. = Installation_CPLD_3.png Connect the bloodlines to the dialyzer. = Installation_CPLD_4.png -Clamp the venous chamber line. = Installation_CPLD_5.png +Clamp the <$2268FF>venous</$> chamber line. = Installation_CPLD_5.png Clamp the heparin line. = Installation_CPLD_6.png -[@Installation] -Title = Install Concentrates and Blood Tubing Set -Install acid and bicarbonate concentrates. = Install_Advanced_1.png -Install blood tubing set and dialyzer. = Install_Advanced_2.png - -[Saline] +[Installation^Saline] Title = Connect Saline Bag Hang saline bag on the hook. = Saline_1.png Clamp saline line. = Saline_2.png Use the saline line to spike saline bag. = Saline_3.png -Unclamp saline line. = Saline_4.png -[@Saline] -Title = Connect Saline Bag -Spike and connect saline bag. = Saline_Advanced_1.png +[Installation^Substitution] +Title = Connect Substitution Line +Connect substitution line to the appropriate Pre or Post dilution port. = Saline_1.png +[@Installation] +Title = Install Concentrates and Blood Tubing Set +Install acid and bicarbonate concentrates. = Install_Advanced_1.png +Install blood tubing set, dialyzer, and saline bag. = Install_Advanced_2.png + [Connect] Title = Connect Bloodlines to the Patient -Clamp arterial and venous bloodlines (2 clamps). = Connect_1.png +Clamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines (2 clamps). = Connect_1.png Remove recirculation connector from the bloodlines. = Connect_2.png Connect bloodlines to patient access lines. = Connect_3.png -Unclamp arterial and venous bloodlines (2 clamps). = Connect_4.png +Unclamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines (2 clamps). = Connect_4.png [@Connect] Title = Connect Bloodlines to the Patient @@ -80,16 +85,45 @@ [Blood Return Setup] Title = Blood Return Connection -Clamp arterial bloodlines and disconnect. = Connect_1.png -Connect arterial bloodline to the saline y-connector. = Connect_2.png -Unclamp arterial bloodline and saline y-connector. = Connect_3.png +Clamp <$B53333>arterial</$> bloodlines and disconnect. = Return_Blood_1.png +Connect <$B53333>arterial</$> bloodline to the saline y-connector. = Return_Blood_2.png +Unclamp <$B53333>arterial</$> bloodline and saline y-connector. = Return_Blood_3.png [$Blood Return Setup] Title = Blood Return Connection -Clamp arterial bloodlines and disconnect. = Connect_1.png -Connect arterial bloodline to the substitution line using a sterile connector. = Connect_2.png -Unclamp arterial bloodline and substitution line . = Connect_3.png +Clamp <$B53333>arterial</$> bloodlines and disconnect. +Connect <$B53333>arterial</$> bloodline to the substitution line using a sterile connector. +Unclamp <$B53333>arterial</$> bloodline and substitution line. +[Recirculate Set Up] +Title = Connect Recirculation Lines +Clamp <$2268FF>venous</$> bloodline and disconnect. +Clamp <$B53333>arterial</$> bloodlines and disconnect from saline y-connector. +Connect <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines using the recirculation connector. +Unclamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines. + +[$Recirculate Set Up] +Title = Connect Recirculation Lines +Clamp <$2268FF>venous</$> bloodline and disconnect. +Clamp <$B53333>arterial</$> and disconnect from the substitution line. +Connect substitution line to the appropriate dilution port. +Connect <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines using the recirculation connector. +Unclamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines. + +[Reconnect To Patient] +Title = Connect Patient Bloodlines +Clamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines. +Remove <$B53333>arterial</$> and <$2268FF>venous</$> line recirculation connector. +Connect <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines to patient access lines. +Unclamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines. + +[$Reconnect To Patient] +Title = Connect Patient Bloodlines +Clamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines. +Remove <$B53333>arterial</$> and <$2268FF>venous</$> line recirculation connector. +Connect <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines to patient access lines. +Unclamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines. + [Disconnect^Disconnect Patient BloodLines] Title = Disconnect Patient BloodLines Clamp and disconnect patient bloodlines. = Install_Advanced_2.png @@ -101,3 +135,17 @@ Tap <b>Auto Eject</b> button and remove the blood tube set. = Install_Advanced_2.png +[Recirculate Set Up] +Title = Connect Recirculation Lines +Clamp venous bloodlines and disconnect. +Clamp arterial bloodlines and disconnect from saline y-connector. +Connect arterial and venous bloodlines using the recirculation connector. +Unclamp arterial and venous bloodlines. + +[Reconnect To Patient] +Title = Connect Bloodlines To Patient +Clamp arterial and venous bloodlines. +Remove arterial and veous line recirculation connector. +Connect arterial and venous bloodlines to patient access lines. +Unclamp arterial and venous bloodlines. +