Index: firmware/App/Controllers/PermeateTank.c =================================================================== diff -u -r6a318f2db61c3567fceea2c1963e0b02d90c8aee -r3475e61837973cd54b99c24fce8e6085d340aad2 --- firmware/App/Controllers/PermeateTank.c (.../PermeateTank.c) (revision 6a318f2db61c3567fceea2c1963e0b02d90c8aee) +++ firmware/App/Controllers/PermeateTank.c (.../PermeateTank.c) (revision 3475e61837973cd54b99c24fce8e6085d340aad2) @@ -331,7 +331,7 @@ setValveState( P39_VALV, VALVE_STATE_OPEN ); setValveState( P20_VALV, VALVE_STATE_CLOSED ); setValveState( P43_VALV, VALVE_STATE_CLOSED ); - setROPumpTargetFlowRateMLPM( PERMEATE_TANK_FILL_RO_PUMP_TGT_FLOW_ML, TRUE ); +// setROPumpTargetFlowRateMLPM( PERMEATE_TANK_FILL_RO_PUMP_TGT_FLOW_ML, TRUE ); tankFillDelayTime = getMSTimerCount(); break; @@ -346,7 +346,7 @@ setValveState( P39_VALV, VALVE_STATE_CLOSED ); setValveState( P20_VALV, VALVE_STATE_CLOSED ); setValveState( P43_VALV, VALVE_STATE_CLOSED ); - setROPumpTargetDutyCycle( getCurrentROPumpDutyCyclePCT(), TRUE ); +// setROPumpTargetDutyCycle( getCurrentROPumpDutyCyclePCT(), TRUE ); tankFullDelayTime = getMSTimerCount(); tankFullAlarmTimeout = getMSTimerCount(); break;