Index: build/AlarmMapping.py =================================================================== diff -u -r32dd58a452d0363f8ae757d156c175bc8ddf0aaa -rd6b6841488e8bc33ba727ffcdba2c37bea8fb983 --- build/AlarmMapping.py (.../AlarmMapping.py) (revision 32dd58a452d0363f8ae757d156c175bc8ddf0aaa) +++ build/AlarmMapping.py (.../AlarmMapping.py) (revision d6b6841488e8bc33ba727ffcdba2c37bea8fb983) @@ -10,15 +10,15 @@ 8 : "HD accelerometer failed POST." 9 : "DG accelerometer failed POST." 10 : "HD blood leak sensor setting embedded mode failure." - 11 : "HD dialysate temperature below target temperature." + 11 : "HD dialysate temperature below target temperature or below safety temp." 12 : "HD firmware image integrity POST test failed." 13 : "DG firmware image integrity POST test failed." 14 : "DG invalid usage record CRC." - 15 : "alarm ID available." + 15 : "HD dialysate temperature above high safety." 16 : "HD alarm audio failed POST." 17 : "HD UI POST failed." 18 : "HD didn't get ACK on message to DG that required acknowledgment." - 19 : "HD dialysate temperature above target temperature." + 19 : "HD dialysate temperature above target temperature or above safety temp." 20 : "DG conductivity sensors invalid calibration record." 21 : "DG drain line volume invalid calibration record." 22 : "DG reservoirs invalid calibration record." @@ -91,7 +91,7 @@ 89 : "DG outlet UV reactor on with no flow." 90 : "DG load cells A1/B1 FPGA fault." 91 : "HD No dialysate flow data receive in the last 3 seconds." - 92 : "Alarm ID available for use." + 92 : "Available for use." 93 : "DG outlet primary conductivity out of range." 94 : "DG pressure out of range." 95 : "DG watchdog expired." @@ -192,7 +192,7 @@ 190 : "DG drain pump off fault." 191 : "DG flow rate out of upper range." 192 : "DG flow rate out of lower range." - 193 : "HD dialysate temperature above low safety range." + 193 : "Available for use." 194 : "DG RO pump duty cycle out of range." 195 : "DG RO pump pressure out of range." 196 : "DG CPi/CPo sensors FPGA fault." @@ -257,7 +257,7 @@ 255 : "HD and UI software builds are not compatible." 256 : "HD processor is in Disinfect Chemical Flush mode." 257 : "Alarm ID available for use." - 258 : "***Available for use***." + 258 : "Alarm Id available." 259 : "HD temperatures out of range." 260 : "UI POST Application Integrity (Sha256Sum) failure." 261 : "UI POST CANBus failure." @@ -321,7 +321,7 @@ 319 : "DG chemical disinfect flush flush sample." 320 : "DG chemical disinfect flush sample timeout." 321 : "DG outlet UV reactor not healthy." - 322 : "RM_ID_HD_DIALYSATE_TEMP_BELOW_LOW_SAFETY_RANGE = 322,." + 322 : "RM_ID_AVAILABLE_15 = 322,." 323 : "Total number of alarms." }