Index: firmware/App/Tasks/TaskGeneral.c =================================================================== diff -u -r4022a06181f6f6d58ccfd465159d95f0df1b0393 -r285b5d82539c96524c93703d52a66fff76fb64fc --- firmware/App/Tasks/TaskGeneral.c (.../TaskGeneral.c) (revision 4022a06181f6f6d58ccfd465159d95f0df1b0393) +++ firmware/App/Tasks/TaskGeneral.c (.../TaskGeneral.c) (revision 285b5d82539c96524c93703d52a66fff76fb64fc) @@ -130,22 +130,22 @@ if ( tmpCtr == ( 5 * 20 ) ) { setAirPumpMotorPower( 255 ); - set3WayValveState( H13_VALV, STATE_OPEN ); + set3WayValveState( H13_VALV, VALVE_3WAY_COMMON_TO_OPEN_STATE ); } else if ( tmpCtr == ( 10 * 20 ) ) { setAirPumpMotorPower( 0 ); - set3WayValveState( H13_VALV, STATE_CLOSED ); + set3WayValveState( H13_VALV, VALVE_3WAY_COMMON_TO_CLOSED_STATE ); } else if ( tmpCtr == ( 15 * 20 ) ) { setAirPumpMotorPower( 255 ); - set3WayValveState( H20_VALV, STATE_OPEN ); + set3WayValveState( H20_VALV, VALVE_3WAY_COMMON_TO_OPEN_STATE ); } else if ( tmpCtr >= ( 20 * 20 ) ) { setAirPumpMotorPower( 0 ); - set3WayValveState( H20_VALV, STATE_CLOSED ); + set3WayValveState( H20_VALV, VALVE_3WAY_COMMON_TO_CLOSED_STATE ); tmpCtr = 0; } } @@ -169,23 +169,23 @@ } // Get level sensor data - readLevelSensors(); + readAirTrapLevelSensors(); // Control blood pump execBloodFlowController(); execAirPumpController(); switch ( sta ) { case 0: - set3WayValveState( H13_VALV, STATE_CLOSED ); - set3WayValveState( H20_VALV, STATE_CLOSED ); + set3WayValveState( H13_VALV, VALVE_3WAY_COMMON_TO_CLOSED_STATE ); + set3WayValveState( H20_VALV, VALVE_3WAY_COMMON_TO_CLOSED_STATE ); setAirPumpState( AIR_PUMP_STATE_ON, AIR_PUMP_MOTOR_OFF ); if ( TRUE == start ) { sta = 1; // lower the level - set3WayValveState( H13_VALV, STATE_OPEN ); + set3WayValveState( H13_VALV, VALVE_3WAY_COMMON_TO_OPEN_STATE ); setAirPumpState( AIR_PUMP_STATE_ON, 255 ); } break; @@ -194,7 +194,7 @@ if ( AIR_TRAP_LEVEL_AIR == getRawLevelSensorState( H16_LEVL ) ) { // stop lowering level - set3WayValveState( H13_VALV, STATE_CLOSED ); + set3WayValveState( H13_VALV, VALVE_3WAY_COMMON_TO_CLOSED_STATE ); setAirPumpState( AIR_PUMP_STATE_OFF, AIR_PUMP_MOTOR_OFF ); ctr = 0; sta = 2; @@ -205,7 +205,7 @@ if ( ++ctr > ( 5 * 20 ) ) { // raise the level - set3WayValveState( H20_VALV, STATE_OPEN ); + set3WayValveState( H20_VALV, VALVE_3WAY_COMMON_TO_OPEN_STATE ); setAirPumpState( AIR_PUMP_STATE_ON, 255 ); sta = 3; } @@ -215,7 +215,7 @@ if ( AIR_TRAP_LEVEL_FLUID == getRawLevelSensorState( H16_LEVL ) ) { // stop raising level - set3WayValveState( H20_VALV, STATE_CLOSED ); + set3WayValveState( H20_VALV, VALVE_3WAY_COMMON_TO_CLOSED_STATE ); setAirPumpState( AIR_PUMP_STATE_OFF, AIR_PUMP_MOTOR_OFF ); ctr = 0; sta = 4; @@ -226,7 +226,7 @@ if ( ++ctr > ( 5 * 20 ) ) { // lower the level - set3WayValveState( H13_VALV, STATE_OPEN ); + set3WayValveState( H13_VALV, VALVE_3WAY_COMMON_TO_OPEN_STATE ); setAirPumpState( AIR_PUMP_STATE_ON, 255 ); sta = 1; }