Index: shared/scripts/configuration/config.py =================================================================== diff -u -r126b027245c71daf414c0bbb43b3d7578a2626aa -rf2bdf1d869c027577633a17e1ce42992d3bd628f --- shared/scripts/configuration/config.py (.../config.py) (revision 126b027245c71daf414c0bbb43b3d7578a2626aa) +++ shared/scripts/configuration/config.py (.../config.py) (revision f2bdf1d869c027577633a17e1ce42992d3bd628f) @@ -120,8 +120,8 @@ 93: "This alarm ID is available for use.", 94: "This alarm ID is available for use.", 95: "This alarm ID is available for use.", - 96: "This alarm ID is available for use.", - 97: "This alarm ID is available for use.", + 96: "Inlet water temperature in high range.", + 97: "Fill conductivity out of range.", 98: "HD battery communication fault.", 99: "HD syringe pump stall alarm.", 100: "HD no cartridge self-test timeout.", @@ -130,7 +130,7 @@ 103: "HD non-volatile calibration group invalid record CRC.", 104: "Air trap level sensors reporting illegal combination of air/fluid.", 105: "DG non-volatile system group invalid record CRC.", - 106: "This alarm ID is available for use.", + 106: "DG inlet water conductivity is greater than threshold.", 107: "HD reports DG restarted fault.", 108: "HD syringe pump ADC error.", 109: "HD syringe pump volume check error.", @@ -141,14 +141,14 @@ 114: "HD venous air bubble detector self-test failure.", 115: "DG temperature sensor out of range.", 116: "DG temperature sensor ADC out of range.", - 117: "This alarm ID is available for use.", - 118: "This alarm ID is available for use.", - 119: "This alarm ID is available for use.", - 120: "This alarm ID is available for use.", + 117: "DG primary heater internal temperature out of range.", + 118: "DG primary heater cold junction temperature out of range.", + 119: "DG trimmer heater internal temperature out of range.", + 120: "DG trimmer heater cold junction temperature out of range.", 121: "DG main primary heater voltage out of range.", 122: "DG small primary heater voltage out of range.", 123: "DG trimmer heater voltage out of range.", - 124: "HD end of treatment alarm (high priority - user still not acting to end treatment).", + 124: "HD end of treatment alarm (high priority).", 125: "Blood sitting too long after treatment stopped by user alarm (>5 min).", 126: "HD blood leak detected alarm.", 127: "Venous pressure too low during treatment." , @@ -171,18 +171,18 @@ 144: "DG software configuration record invalid CRC.", 145: "Concentrate conductivity after adding acid out of range alarm.", 146: "Dialysate conductivity out of range.", - 147: "DG dialysate generation conductivity fault alarm.", + 147: "Wait for the DG to produce dialysate.", 148: "Inlet water temperature too high.", - 149: "Inlet water temperature too low.", - 150: "Inlet water conductivity too high.", - 151: "Inlet water conductivity too low.", - 152: "Inlet water pressure too low.", + 149: "Alarm ID available for use.", + 150: "Inlet water conductivity in high range.", + 151: "Inlet water conductivity in low range.", + 152: "Inlet water pressure in low range.", 153: "HD prime completed high priority alarm.", 154: "EEPROM operations (read, write, erase) failure.", 155: "DG software configuration record invalid CRC.", 156: "HW usage data (treatment time in HD and total consumed water in DG) failure.", 157: "DG chemical disinfect prime acid line timeout.", - 158: "This alarm ID is available for use.", + 158: "Inlet water temperature is in the low range.", 159: "Dialysate inlet pump failed flow vs motor speed check.", 160: "Blood pump rotor speed too high.", 161: "This alarm ID is available for use.", @@ -248,7 +248,7 @@ 221: "HD Saline bag is empty.", 222: "HD dialysate temperature too high alarm.", 223: "HD dialysate temperature too low alarm.", - 224: "Treatment stopped by user action - pressed stop button.", + 224: "Treatment stopped by user action.", 225: "HD end of treatment warning.", 226: "HD prime completed low priority alarm.", 227: "HD prime out of time alarm.",