Index: shared/scripts/configuration/config.py =================================================================== diff -u -r83caf575cae31050f77bd25d2bb86f380c2338c8 -r2961accdbc24fa832a3c6fa3f12fa52ce7938124 --- shared/scripts/configuration/config.py (.../config.py) (revision 83caf575cae31050f77bd25d2bb86f380c2338c8) +++ shared/scripts/configuration/config.py (.../config.py) (revision 2961accdbc24fa832a3c6fa3f12fa52ce7938124) @@ -20,98 +20,11 @@ COMMON_PATH = os.environ['HOME']+"/Projects" - -COLOR_CODES = {"Aqua": "#81ffff", "Blue": "#017dea", "Blue 2": "#1090d5", "Green": "#29fd2d", "Grey": "#d3d3d3", - "Lavender": "#db98f5", "Light Blue": "#acd7f1", "Light Teal": "#29f1da","Lime": "#b7fc36", - "Magenta":"#fd28fd", "Orange": "#f2721c", "Peach":"#f1979a", "Red": "#c53b33", "Rose":"#fc178d", - "Slate blue":"#7f7ffa", "Violet": "#6435c9", "White": "#ffffff", "Yellow": "#fcfc4d"} - -#standby mode -GOODMORNING_START_TIME_SEC = 0 -GOODEVENING_START_TIME_SEC = 43200 - -BLOOD_PRIMING_TEXT = "Blood Priming" -RINSEBACK_UNIT = " mL" -RINSEBACK_UNIT_MIN = " mL/min" -BLOOD_PRIMING_DEFAULT_VALUE = "0 mL" - -#end-treatment screens +#rinseback setup state CURRENT_COLOR = '#000000' COMPLETE_COLOR= '#4290ec' ENABLED_COLOR = '#fcfcfc' INCOMPLETE_COLOR = '#607a91' -END_TREATMENT_SCREEN = ["Rinseback Setup", "Recirculate", "Treatment Complete", "Treatment Paused State"] +NUM_OF_REQUEST_REJECT_REASONS = 43 -#rinseback-setup -RINSE_BACK_SETUP_TEXT = "Rinseback Setup" -RINSEBACK_BUTTON_TEXT = "START RINSEBACK" -END_IMAGE_BUTTON_TEXT = "End" -DECELERATE_BUTTON_TEXT = "Decelerate" -ACCELERATE_BUTTON_TEXT = "Accelerate" -PAUSE_BUTTON_TEXT = "Pause" -RESUME_BUTTON_TEXT = "Resume" -RINSEBACK_TEXT = "Rinseback" -RINSEBACK_COMPLETE_TEXT = "Rinseback Complete" -END_TREATMENT_BUTTON_TEXT = "END TREATMENT" -ADDITIONAL_BUTTON_TEXT = "ADDITIONAL" -ADDITIONAL_RINSEBACK_TEXT = "Additional Rinseback" -TIME_OUT_DURATION_300 = 300 -TIME_OUT_DURATION_200 = 200 -TIME_OUT_DURATION_100 = 100 -COUNT_DOWN_TIME_100 = 100 -MINIMUM_COUNTDOWN_TIME = 0 -BEGIN_PRIME_TITLE = "Begin Prime" -PRIMING_TITLE = "Priming" -SYSTEM_SELF_TEST_TITLE = "System Self Test" -FILTER_FLUSH_TITLE = "Filter Flush" - -# dictionary of rejection reason from application source code. -# message location -> denali-> Headers-> common-> MsgDefs.h -REJECTION_REASON = { - 0: "No Active Alarm List", - 1: "REQUEST_REJECT_REASON_NOT_ALLOWED_IN_CURRENT_MODE", # Request is not allowed in the current operating mode - 2: "REQUEST_REJECT_REASON_TIMEOUT_WAITING_FOR_USER_CONFIRM", # Validated request was not confirmed by user in reasonable time - 3: "REQUEST_REJECT_REASON_NOT_IN_TREATMENT_MODE", # Request is not allowed if not in treatment mode - 4: "REQUEST_REJECT_REASON_INVALID_TREATMENT_STATE", # Request is not allowed in current treatment state - 5: "REQUEST_REJECT_REASON_TREATMENT_TOO_CLOSE_TO_FINISHED", # Request is not allowed so near end of treatment - 6: "REQUEST_REJECT_REASON_TREATMENT_TIME_OUT_OF_RANGE", # Treatment duration is out of range - 7: "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_CURRENT", # Treatment time change is less than currently elapsed treatment time - 8: "REQUEST_REJECT_REASON_BLOOD_FLOW_OUT_OF_RANGE", # Blood flow is out of range - 9: "REQUEST_REJECT_REASON_DIAL_FLOW_OUT_OF_RANGE", # Dialysate flow is out of range - 10: "REQUEST_REJECT_REASON_DIAL_VOLUME_OUT_OF_RANGE", # Dialysate flow rate or treatment duration causes dialysate volume to exceed limit - 11: "REQUEST_REJECT_REASON_UF_VOLUME_OUT_OF_RANGE", # Ultrafiltration volume is out of range - 12: "REQUEST_REJECT_REASON_UF_RATE_OUT_OF_RANGE", # Ultrafiltration rate is out of range - 13: "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_MINIMUM", # Treatment time change is less than minimum treatment time - 14: "REQUEST_REJECT_REASON_UF_NOT_IN_PROGESS", # Ultrafiltration is not currently in progress - 15: "REQUEST_REJECT_REASON_UF_NOT_PAUSED", # Ultrafiltration is not currently paused - 16: "REQUEST_REJECT_REASON_SALINE_BOLUS_IN_PROGRESS", # A saline bolus is in progress - 17: "REQUEST_REJECT_REASON_PARAM_OUT_OF_RANGE", # A treatment parameter is out of range - 18: "REQUEST_REJECT_REASON_HEPARIN_PRESTOP_EXCEEDS_DURATION", # The Heparin pre-stop setting is greater than the treatment duration - 19: "REQUEST_REJECT_REASON_ARTERIAL_PRESSURE_LOW_VS_HIGH", # Arterial pressure low and high alarm limits are not inconsistent - 20: "REQUEST_REJECT_REASON_VENOUS_PRESSURE_LOW_VS_HIGH", # Venous pressure low and high alarm limits are inconsistent - 21: "REQUEST_REJECT_REASON_SALINE_MAX_VOLUME_REACHED", # Saline bolus volume maximum has been reached - no more saline allowed - 22: "REQUEST_REJECT_REASON_SALINE_BOLUS_NOT_IN_PROGRESS", # A saline bolus is not in progress - 23: "REQUEST_REJECT_REASON_ACTION_DISABLED_IN_CURRENT_STATE", # Requested user action is disabled in current state - 24: "REQUEST_REJECT_REASON_ALARM_IS_ACTIVE", # Requested user action not allowed while alarm is active - 25: "REQUEST_REJECT_REASON_INVALID_COMMAND", # Requested user action invalid - 26: "REQUEST_REJECT_REASON_TREATMENT_IS_COMPLETED", # The treatment has been completed - 27: "REQUEST_REJECT_REASON_ADDL_RINSEBACK_MAX_VOLUME_REACHED", # Rinseback additional volume maximum has been reached - no more additional rinsebacks allowed - 28: "REQUEST_REJECT_REASON_UF_VOLUME_NOT_SET", # Ultrafiltration volume is not set yet - 29: "REQUEST_REJECT_REASON_NO_PATIENT_CONNECTION_CONFIRM", # The user has not confirmed patient connection - 30: "REQUEST_REJECT_REASON_HEPARIN_PAUSE_INVALID_IN_THIS_STATE", # Heparin cannot be paused if not currently deliverying Heparin - 31: "REQUEST_REJECT_REASON_HEPARIN_NOT_PAUSED", # Heparin cannot be resumed if not paused - 32: "REQUEST_REJECT_REASON_DG_COMM_LOST", # Treatment cannot initiate if DG comm is lost - 33: "REQUEST_REJECT_REASON_DRAIN_NOT_COMPLETE", # Post-treatment reservoirs drain not complete - 34: "REQUEST_REJECT_REASON_DG_NOT_IN_STANDBY_IDLE_STATE", # Treatment cannot initiate if DG is not in standby idle state - 35: "REQUEST_REJECT_REASON_INVALID_REQUEST_FORMAT", # Request message not formatted properly - 36: "REQUEST_REJECT_REASON_INVALID_DATE_OR_TIME", # Given date/time is invalid - 37: "REQUEST_REJECT_REASON____AVAILABLE_1", # Not used - available for use - 38: "REQUEST_REJECT_REASON_BATTERY_IS_NOT_CHARGED", # Battery does not have enough charge to start treatment - 39: "REQUEST_REJECT_REASON_RINSEBACK_NOT_COMPLETED", # Cannot move on to recirculate without completing full rinseback. - 40: "REQUEST_REJECT_REASON_RESERVOIR_ONE_IS_NOT_READY", # Reservoir one fill is not complete - 41: "REQUEST_REJECT_REASON_PUMP_TRACK_NOT_CLOSED", # Pump track is not ready / closed - 42: "REQUEST_REJECT_REASON_DOOR_NOT_CLOSED", # Door is not closed - 43: "REQUEST_REJECT_REASON_SYRINGE_NOT_PRESENT", # Syringe is not present - } -NUM_OF_REQUEST_REJECT_REASONS = 43 \ No newline at end of file