Index: shared/scripts/configuration/config.py =================================================================== diff -u -r8b2acf92efde9ddbeb292e0fb420b595dbd8c618 -rf2563fd426c2ecf1ac993414584b937e5bf27256 --- shared/scripts/configuration/config.py (.../config.py) (revision 8b2acf92efde9ddbeb292e0fb420b595dbd8c618) +++ shared/scripts/configuration/config.py (.../config.py) (revision f2563fd426c2ecf1ac993414584b937e5bf27256) @@ -15,6 +15,8 @@ import os +from configuration.strings import * + AUT_NAME = "denaliSquish" COMMON_PATH = os.environ['HOME']+"/Projects" @@ -29,67 +31,9 @@ GOODMORNING_START_TIME_SEC = 0 GOODEVENING_START_TIME_SEC = 43200 -BLOOD_PRIMING_TEXT = "Blood Priming" -SALINE_UNIT = "mL" -BLOOD_PRIMING_DEFAULT_VALUE = "0 mL" - - -#main treatment pressure -PRESSURE_TITLE = "PRESSURES" -ARTERIAL_TITLE = "Arterial" -VENOUS_TITLE = "Venous" -VENOUS_UOM = "mmHg" -ARTERIAL_UOM = "mmHg" -LOW_TEXT = "LOW" -HIGH_TEXT = "HIGH" ACCEPTED = True REJECTED = False -# dictionary of rejection reason from application source code. -# rejection message location -> denali-> Headers-> common-> MsgDefs.h -REJECTION_REASON = { -0 : "REQUEST_REJECT_REASON_NONE" , # Used when there is no rejection -1 : "REQUEST_REJECT_REASON_NOT_ALLOWED_IN_CURRENT_MODE" , # "REQuest is not allowed in the current operating mode -2 : "REQUEST_REJECT_REASON_TIMEOUT_WAITING_FOR_USER_CONFIRM" , # Validated "REQuest was not confirmed by user in reasonable time -3 : "REQUEST_REJECT_REASON_NOT_IN_TREATMENT_MODE" , # "REQuest is not allowed if not in treatment mode -4 : "REQUEST_REJECT_REASON_INVALID_TREATMENT_STATE" , # "REQuest is not allowed in current treatment state -5 : "REQUEST_REJECT_REASON_TREATMENT_TOO_CLOSE_TO_FINISHED" , # "REQuest is not allowed so near end of treatment -6 : "REQUEST_REJECT_REASON_TREATMENT_TIME_OUT_OF_RANGE" , # Treatment duration is out of range -7 : "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_CURRENT" , # Treatment time change is less than currently elapsed treatment time -8 : "REQUEST_REJECT_REASON_BLOOD_FLOW_OUT_OF_RANGE" , # Blood flow is out of range -9 : "REQUEST_REJECT_REASON_DIAL_FLOW_OUT_OF_RANGE" , # Dialysate flow is out of range -10 : "REQUEST_REJECT_REASON_DIAL_VOLUME_OUT_OF_RANGE" , # Dialysate flow rate or treatment duration causes dialysate volume to exceed limit -11 : "REQUEST_REJECT_REASON_UF_VOLUME_OUT_OF_RANGE" , # Ultrafiltration volume is out of range -12 : "REQUEST_REJECT_REASON_UF_RATE_OUT_OF_RANGE" , # Ultrafiltration rate is out of range -13 : "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_MINIMUM" , # Treatment time change is less than minimum treatment time -14 : "REQUEST_REJECT_REASON_UF_NOT_IN_PROGESS" , # Ultrafiltration is not currently in progress -15 : "REQUEST_REJECT_REASON_UF_NOT_PAUSED" , # Ultrafiltration is not currently paused -16 : "REQUEST_REJECT_REASON_SALINE_BOLUS_IN_PROGRESS" , # A saline bolus is in progress -17 : "REQUEST_REJECT_REASON_PARAM_OUT_OF_RANGE" , # A treatment parameter is out of range -18 : "REQUEST_REJECT_REASON_HEPARIN_PRESTOP_EXCEEDS_DURATION" , # The Heparin pre-stop setting is greater than the treatment duration -19 : "REQUEST_REJECT_REASON_ARTERIAL_PRESSURE_LOW_VS_HIGH" , # Arterial pressure low and high alarm limits are not inconsistent -20 : "REQUEST_REJECT_REASON_VENOUS_PRESSURE_LOW_VS_HIGH" , # Venous pressure low and high alarm limits are inconsistent -21 : "REQUEST_REJECT_REASON_SALINE_MAX_VOLUME_REACHED" , # Saline bolus volume maximum has been reached - no more saline allowed -22 : "REQUEST_REJECT_REASON_SALINE_BOLUS_NOT_IN_PROGRESS" , # A saline bolus is not in progress -23 : "REQUEST_REJECT_REASON_ACTION_DISABLED_IN_CURRENT_STATE" , # "REQuested user action is disabled in current state -24 : "REQUEST_REJECT_REASON_ALARM_IS_ACTIVE" , # "REQuested user action not allowed while alarm is active -25 : "REQUEST_REJECT_REASON_INVALID_COMMAND" , # "REQuested user action invalid -26 : "REQUEST_REJECT_REASON_TREATMENT_IS_COMPLETED" , # The treatment has been completed -27 : "REQUEST_REJECT_REASON_ADDL_RINSEBACK_MAX_VOLUME_REACHED" , # Rinseback additional volume maximum has been reached - no more additional rinsebacks allowed -28 : "REQUEST_REJECT_REASON_UF_VOLUME_NOT_SET" , # Ultrafiltration volume is not set yet -29 : "REQUEST_REJECT_REASON_NO_PATIENT_CONNECTION_CONFIRM" , # The user has not confirmed patient connection -30 : "REQUEST_REJECT_REASON_HEPARIN_PAUSE_INVALID_IN_THIS_STATE" , # Heparin cannot be paused if not currently deliverying Heparin -31 : "REQUEST_REJECT_REASON_HEPARIN_NOT_PAUSED" , # Heparin cannot be resumed if not paused -32 : "REQUEST_REJECT_REASON_DG_COMM_LOST" , # Treatment cannot initiate if DG comm is lost -33 : "REQUEST_REJECT_REASON_DRAIN_NOT_COMPLETE" , # Post-treatment reservoirs drain not complete -34 : "REQUEST_REJECT_REASON_DG_NOT_IN_STANDBY_IDLE_STATE" , # Treatment cannot initiate if DG is not in standby idle state -35 : "REQUEST_REJECT_REASON_INVALID_REQUEST_FORMAT" , # "REQuest message not formatted properly -36 : "REQUEST_REJECT_REASON_INVALID_DATE_OR_TIME" , # Given date/time is invalid -37 : "REQUEST_REJECT_REASON_NO_NEW_TREATMENT_ALARM_TRIGGERED" , # Treatment cannot initiate if an alarm with no new treatment property has triggered before -38 : "REQUEST_REJECT_REASON_BATTERY_IS_NOT_CHARGED" , # Battery does not have enough charge to start treatment -39 : "REQUEST_REJECT_REASON_RINSEBACK_NOT_COMPLETED" , # Cannot move on to recirculate without completing full rinseback. -} - #pressure PRESSURE_STEPS = 10 ARTERIAL_PRESSURE_MINIMUM = -400