Index: shared/scripts/configuration/config.py =================================================================== diff -u -r9e8d0a1f125fa5b8fa103adc30489bd55893ad47 -r11b2970e98eb80e8bd299d25b607b8ff00a2043b --- shared/scripts/configuration/config.py (.../config.py) (revision 9e8d0a1f125fa5b8fa103adc30489bd55893ad47) +++ shared/scripts/configuration/config.py (.../config.py) (revision 11b2970e98eb80e8bd299d25b607b8ff00a2043b) @@ -6,9 +6,9 @@ # THIS CODE MAY NOT BE COPIED OR REPRODUCED IN ANY FORM, IN PART OR IN # WHOLE, WITHOUT THE EXPLICIT PERMISSION OF THE COPYRIGHT OWNER. # -# @file utils.py +# @file config.py # -# @author (last) Joseph varghese +# @author (last) LTTS # @date (last) 18-Jan-2022 # ############################################################################ @@ -19,29 +19,292 @@ AUT_NAME = "denaliSquish" -COMMON_PATH = os.environ['HOME']+"/Projects" - COLOR_CODES = {"Aqua": "#81ffff", "Blue": "#017dea", "Blue 2": "#1090d5", "Green": "#29fd2d", "Grey": "#d3d3d3", "Lavender": "#db98f5", "Light Blue": "#acd7f1", "Light Teal": "#29f1da","Lime": "#b7fc36", "Magenta":"#fd28fd", "Orange": "#f2721c", "Peach":"#f1979a", "Red": "#c53b33", "Rose":"#fc178d", "Slate blue":"#7f7ffa", "Violet": "#6435c9", "White": "#ffffff", "Yellow": "#fcfc4d"} + CURRENT_COLOR = '#000000' COMPLETE_COLOR= '#4290ec' ENABLED_COLOR = '#fcfcfc' INCOMPLETE_COLOR = '#607a91' +TREATMENT_UNHIGHLIGHTED_COLOR = "#000000" +TREATMENT_HIGHLIGHTED_COLOR = "#135088" + +COMMON_PATH = os.environ['HOME']+"/Projects" + +#StandBy Mode +BLOOD_PRIMING_DEFAULT_VALUE = "0 mL" + +#instructions_imagelocation +INSTRUCTION_CONF_LOCATION = "/home/denali/Projects/application/resources/settings/Instructions/Instructions.conf" +IMAGE_LOCATION = "file:///home/denali/Projects/application/resources/settings/Instructions/" +EXPECTED_IMAGE_LOCATION = "/home/denali/Projects/application/resources/settings/Instructions/" +SERVICE_CONF_LOCATION = os.environ['HOME']+"/Projects/application/resources/settings/Service.conf" +TREATMENT_LOG_LOCATION = '/home/denali/Desktop/sd-card/treatment/*.log' + +ACCEPTED = True +REJECTED = False +ENABLED = True +DISABLED = False +CURRENT_COLOR = '#000000' +COMPLETE_COLOR = '#4290ec' +ENABLED_COLOR = '#fcfcfc' +INCOMPLETE_COLOR = '#607a91' OUT_OF_RANGE_COLOR = "#c53b33" +#main treatment screen +IN_RANGE_COLOR = "#fcfcfc" +SYSTOLIC_LOWER_LIMIT = 60 +SYSTOLIC_UPPER_LIMIT = 250 +DIASTOLIC_LOWER_LIMIT = 40 +DIASTOLIC_UPPER_LIMIT = 200 +HEART_RATE_LOWER_LIMIT = 40 +HEART_RATE_UPPER_LIMIT = 180 +KEYBOARD_SWITCH = ["ABC", "&123"] + +HEPARIN_TYPE = "UFH 1,000 IU/mL" +ACID_CONCENTRATE = ["08-1251-1", "08-2251-0", "08-3251-9"] +BICARBONATE_CONCENTRATE = "Fres. Centrisol" +DIALYZER_TYPE = ["BB Diacap Pro 13H", "BB Diacap Pro 16H", "BB Diacap Pro 19H", "F Optiflux F160NRe", "F Optiflux F180NRe"] + +COLOR_CODES = {"Aqua": "#81ffff", "Blue": "#017dea", "Blue 2": "#1090d5", "Green": "#29fd2d", "Grey": "#d3d3d3", + "Lavender": "#db98f5", "Light Blue": "#acd7f1", "Light Teal": "#29f1da","Lime": "#b7fc36", + "Magenta":"#fd28fd", "Orange": "#f2721c", "Peach":"#f1979a", "Red": "#c53b33", "Rose":"#fc178d", + "Slate blue":"#7f7ffa", "Violet": "#6435c9", "White": "#ffffff", "Yellow": "#fcfc4d"} + +TREATMENT_UNHIGHLIGHTED_COLOR = "#000000" +TREATMENT_HIGHLIGHTED_COLOR = "#135088" + +#create custom treatment +HIGHER_VALUE_OF_BLOOD_FLOW_RATE = 500 +LOWER_VALUE_OF_BLOOD_FLOW_RATE = 100 +STEP_VALUE_OF_BLOOD_FLOW_RATE = 25 +BUFFER_LOW_AND_HIGH_LIMITS = 30 +ARTERIAL_VALUE_0 = 0 +ARTERIAL_VALUE_NEGATIVE_300 = -300 +ARTERIAL_VALUE_NEGATIVE_20 = -20 +ARTERIAL_VALUE_NEGATIVE_270 = -270 +VENOUS_VALUE_600 = 600 +VENOUS_VALUE_20 = 20 +VENOUS_VALUE_50 = 50 +VENOUS_VALUE_570 = 570 +POSITIVE_BUFFER = 10 +NEGATIVE_BUFFER = -10 + + +NUM_OF_ALARM_PRIORITIES = 4 # Total number of alarm priorities + + + + +NUM_OF_MSG_ID = 289 + + +ALARM_ID_NO_ALARM = 0 +ALARM_ID_OUT_OF_RANGE = 290 + +# alarm colors +ALARMS_COLORS_HEADER = { + "ALARM_PRIORITY_NONE" : "#438feb", + "ALARM_PRIORITY_LOW" : "#db8f00", + "ALARM_PRIORITY_MEDIUM" : "#db8f00", + "ALARM_PRIORITY_HIGH" : "#831913" +} + +ALARMS_COLORS_BODY = { + "ALARM_PRIORITY_NONE" : "#254670", + "ALARM_PRIORITY_LOW" : "#f5a623", + "ALARM_PRIORITY_MEDIUM" : "#f5a623", + "ALARM_PRIORITY_HIGH" : "#c53b33" +} + +ALARM_MUTE_FLAG = 0B0000001000000000 +ALARM_UNMUTE_FLAG = 0B0000000000000000 + +ALARM_BUTTONS_OK = 0B0000000010111000 + +ALARM_BUTTONS_RESUME = 0B0000000000110000 +ALARM_BUTTONS_RESUME_RINSEBACK = 0B0000000000100000 +ALARM_BUTTONS_RESUME_END = 0B0000000000010000 + +ALARM_BUTTONS_RINSEBACK = 0B0000000000101000 +ALARM_BUTTONS_RINSEBACK_RESUME = ALARM_BUTTONS_RESUME_RINSEBACK +ALARM_BUTTONS_RINSEBACK_END = 0B0000000000001000 + +ALARM_BUTTONS_END = 0B0000000000011000 +ALARM_BUTTONS_END_RESUME = ALARM_BUTTONS_RESUME_END +ALARM_BUTTONS_END_RINSEBACK = ALARM_BUTTONS_RINSEBACK_END + +ALARM_BUTTONS_RESUME_RINSEBACK_END = 0B0000000000000000 +ALARM_BUTTONS_RINSEBACK_RESUME_END = ALARM_BUTTONS_RESUME_RINSEBACK_END +ALARM_BUTTONS_END_RESUME_RINSEBACK = ALARM_BUTTONS_RESUME_RINSEBACK_END + +#standby mode & ultrafiltration +SALINE_BOLUS_CUMULATIVE = 300 +UF_MINIMUM_VALUE = 0 +UF_MAXIMUM_VALUE = 600 + + #standby mode GOODMORNING_START_TIME_SEC = 0 GOODEVENING_START_TIME_SEC = 43200 -BLOOD_PRIMING_TEXT = "Blood Priming" -SALINE_UNIT = "mL" -BLOOD_PRIMING_DEFAULT_VALUE = "0 mL" +#pressure +PRESSURE_STEPS = 10 +ARTERIAL_PRESSURE_MINIMUM = -400 +ARTERIAL_PRESSURE_MAXIMUM = +600 +ARTERIAL_PRESSURE_LOW_MIN = -300 +ARTERIAL_PRESSURE_LOW_DEF = -300 +ARTERIAL_PRESSURE_LOW_MAX = +200 +ARTERIAL_PRESSURE_HIGH_MIN = -300 +ARTERIAL_PRESSURE_HIGH_DEF = +100 +ARTERIAL_PRESSURE_HIGH_MAX = +200 + +VENOUS_PRESSURE_MINIMUM = -100 +VENOUS_PRESSURE_MAXIMUM = +700 +VENOUS_PRESSURE_LOW_MIN = -100 +VENOUS_PRESSURE_LOW_DEF = -100 +VENOUS_PRESSURE_LOW_MAX = +600 +VENOUS_PRESSURE_HIGH_MIN = +100 +VENOUS_PRESSURE_HIGH_DEF = +400 +VENOUS_PRESSURE_HIGH_MAX = +600 + +#main_treatment_flows +BLOOD_FLOW_MINIMUM_VALUE = 100 +BLOOD_FLOW_BUFFER = 25 +FLOW_SLIDER_WIDTH_BUFFER = 37 +BLOOD_FLOW_MAXIMUM_VALUE = 500 +DIALYSATE_FLOW_MINIMUM_VALUE = 0 +DIALYSATE_FLOW_MAXIMUM_VALUE = 0 # Seems to be bug. need change +DIALYSATE_FLOW_BUFFER = 50 +DIALYSATE_FLOW_SLIDER_WIDTH_BUFFER = 60 + +#main treatment screen +OUT_OF_RANGE_COLOR = "#c53b33" +IN_RANGE_COLOR = "#fcfcfc" +SYSTOLIC_LOWER_LIMIT = 60 +SYSTOLIC_UPPER_LIMIT = 250 +DIASTOLIC_LOWER_LIMIT = 40 +DIASTOLIC_UPPER_LIMIT = 200 +HEART_RATE_LOWER_LIMIT = 40 +HEART_RATE_UPPER_LIMIT = 180 +BLOOD_PRIMING_RANGE = 300 +BLOOD_PRIMING_TARGET_MAXIMUM = 300 + +#tst_pretreatment_screens +NUM_OF_PRETREATMENT_BULLETS = len(PRE_TREATMENT_SCREENS) +SALINE_BOLUS_CUMULATIVE = 300 + +#patient id +KEYBOARD_SWITCH = ["ABC", "&123"] +PATIENT_ID_COMBINATION = { + "qwerty" : "qwerty", + "sampleid" : "sampleid", + "abcdefghijklmnop" : "abcdefghijklmnop", + "patientid" : "patientid", + "username" : "username", + "sA@MpLE#123" : "sAMpLE123", + "A@BH&321" : "ABH321", + "5432@qwerty" : "5432qwerty" +} + +#Random selection for operational parameter for custom dta +OPERATIONAL_PARAMETERS = {"Heparin Type": HEPARIN_TYPE, "Acid Concentrate": "08-1251-1", + "Bicarbonate Concentrate": BICARBONATE_CONCENTRATE, "Dialyzer Type": "BB Diacap Pro 16H"} + +#dictionary consist of custom treatment values +CREATE_CUSTOM_TREATMENT = { + "Blood Flow Rate": 250, + "Dialysate Flow Rate": 400, + "Duration": 270, + "Heparin Dispensing Rate": 0.5, + "Heparin Bolus Volume": 1, + "Heparin Stop Time": 100, + "Saline Bolus Volume": 200, + "Dialysate Temperature": 37, + "Blood Pressure Measurement Interval": 40, + "Rinseback Flow Rate": 100, + "Arterial Pressure Limit Low" : -30, + "Arterial Pressure Limit High" : 0, + "Blood Pressure Measure Interval" : 40, + "Rinseback Rate" : 100, + "Venous Pressure Limit High" : 590, + "Venous Pressure Limit Low": 560 +} + +#dictionary consist of slider values of treatment parameters +CREATE_TREATMENT_PARAMETER_RANGE = { + "Blood Flow Rate": [100, 125, 150, 175, 200, 225, 250, 275, 300, 325, 350, 375, 400, 425, 450, 475, 500], + "Dialysate Flow Rate": [100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600], + "Duration": [60, 75, 90, 105, 120, 135, 150, 165, 180, 195, 240, 255, 270, 285, 300, 315, 330, 345, 360, 375, 390, 405, 420, 435, 450, 465, 480], + "Heparin Dispensing Rate": [0, 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1, 0], + "Heparin Bolus Volume": [0, 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0, 1.1, 1.2, 1.3, 1.4, 1.5, 1.6, 1.7, 1.8, 1.9, 2, 0], + "Heparin Stop Time": [0, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100, 110, 120, 130, 140, 150, 160, 170, 180, 190, 200, 210, 220, 230, 240, 250, 260, 270, 280, 290, 300, 310, 320, 330, 340, 350, 360, 370, 380, 390, 400, 410, 420, 430, 440, 450, 460, 470, 0], + "Saline Bolus Volume": [100, 200, 300], + "Dialysate Temperature": [35.0, 35.5, 36.0, 36.5, 37.0], + "Blood Pressure Measurement Interval": [0, 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 0], + "Rinseback Flow Rate": [50, 75, 100, 125, 150], +} + +#dictionary consist of slider minimum value, slider buffer value, width buffer of slider +CREATE_TREATMENT_SLIDER_VALUES = { + + "blood_flow_rate" : [100, 25, 46], + "dialysate_flow_rate" : [100, 50, 75], + "duration" : [60, 15, 26.6], + "heparin_dispensing_rate" : [0, 0.1, 75], + "heparin_bolus_volume" : [0, 0.1, 37], + "heparin_stop_time" : [0, 10, 15.9], + "saline_bolus" : [100, 100, 375], + "dialysate_temperature" : [35, 0.5, 187.5], + "arterial_pressure_limit_high" : [20, 10, 11.931], + "blood_pressure_measurement_interval" : [0, 5, 62], + "rinseback_flow_rate" : [50, 25, 187], +} + + +#ultrafilteration volume based on flow parameters. Python list contains Rotational speed, Motor speed, +# MC speed, MC current and PWM. +TREATMENT_ULTRAFILTRATION_FLOW_PARAMETERS = { + 0 : [100, 0, 0, 0, 0, 0, 0], + 1 : [220, 1.45, 1.45, 1.45, 1.45, 1.45, 1.45], + } + +#dictionary contains uf maximum and minimum value's to set. +TREATMENT_ULTRAFILTRATION_TESTING_OPTION = { + 0 : {"uf_maximum" : 600, "uf_minimum" : 0}, + 1 : {"uf_maximum" : 480, "uf_minimum" : 250}, + } + +#tst_pretreatment_screens +NUM_OF_PRETREATMENT_BULLETS = len(PRE_TREATMENT_SCREENS) + +#dictionary contains saline cumulative and saline delivered value +#key : saline cumulative value. +#value: saline delivered value +SALINE_BOLUS_VALUES = { + 0 : 0, + 1.0 : 1.0, + 125.56 : 100.56, + 165.87 : 145.87, + 220.65 : 220.65, + 325.25 : 300.25, + 400.86 : 380.86, + 500.00 : 500.25, + 634.76 : 634.76, + 823.65 : 800.65, + 999.99 : 999.99, + 1000 : 1000 +} + +#testing options for main treatment saline +SALINE_BOLUS_TARGET = [0, 1, 150, 155, 299, 300] #Boundary Value Analysis + # pretreatment_patient_connection SYSTOLIC_PRESSSURE_120 = 120 SYSTOLIC_PRESSSURE_113 = 113 @@ -70,17 +333,11 @@ HEART_RATE_VAL_110 = 110 HEART_RATE_VAL_181 = 181 HEART_RATE_VAL_200 = 200 -SYSTOLIC_LOWER_LIMIT = 60 -SYSTOLIC_UPPER_LIMIT = 250 -DIASTOLIC_LOWER_LIMIT = 40 -DIASTOLIC_UPPER_LIMIT = 200 -HEART_RATE_LOWER_LIMIT = 40 -HEART_RATE_UPPER_LIMIT = 180 UF_MINIMUM_SLIDER_WIDTH = -2 UF_MAXIMUM_SLIDER_WIDTH = 638.00 UF_VALID_RANGE = 700 TRAINING_INDICATOR_SCREEN = 4 -ULTRAFILTRATION_VOLUME_COMBINATION_FROM_ULTRAFILTERATION_SETUP_SCREEN = { +ULTRAFILTRATION_VOLUME_COMBINATION_FROM_ULTRAFILTRATION_SETUP_SCREEN = { "OPTION_1" : {"uf_maximum" : 800, "uf_minimum" : 0}, "OPTION_2" : {"uf_maximum" : 500, "uf_minimum" : 0}, "OPTION_3" : {"uf_maximum" : 550, "uf_minimum" : 0}, @@ -95,6 +352,99 @@ "OPTION_12" : {"uf_maximum" : 1250, "uf_minimum" : 0}, } +#tst_pretreatment_screens color palettes +CURRENT_COLOR = '#000000' +COMPLETE_COLOR= '#4290ec' +ENABLED_COLOR = '#fcfcfc' +INCOMPLETE_COLOR = '#607a91' + + +#pre-treatment_priming +NOT_VISIBLE = False +VISIBLE = True +FOCUS = True +NOT_IN_FOCUS = False +TIME_OUT_DURATION_300 = 300 +TIME_OUT_DURATION_200 = 200 +TIME_OUT_DURATION_100 = 100 +COUNT_DOWN_TIME_100 = 100 +MINIMUM_COUNTDOWN_TIME = 0 +ENABLED = True +DISABLED = False +CONSUMABLE_SELF_TEST_BICARB_PUMP_CHECK_STATE = 3 + + +#pre-treatment_priming +NOT_VISIBLE = False +VISIBLE = True +FOCUS = True +NOT_IN_FOCUS = False + +#Filter Flush + +MAXIMUM_COUNTDOWN_TIME = 300 +MINIMUM_COUNTDOWN_TIME = 0 +TIME_OUT_DURATION_300 = 300 +TIME_OUT_DURATION_200 = 200 +TIME_OUT_DURATION_100 = 100 +COUNT_DOWN_TIME_100 = 100 +MINIMUM_COUNTDOWN_TIME = 0 +CONSUMABLE_SELF_TEST_BICARB_PUMP_CHECK_STATE = 3 + +VALID = True +INVALID = False + +#post treatment review +ACID_CONCENTRATE_POST = ["Fres. Naturalyte", "08-1251-1", "08-2251-0", "08-3251-9", "08-3251-9"] +BRIGHTNESS_MIN_VAL = 20 +BRIGHTNESS_MAX_VAL = 100 +VOLUME_MIN_VAL = 20 +VOLUME_MAX_VAL = 100 + +#dictionary consist of review parameters values of post treatment +POST_TREATMENT_REVIEW_PARAMETER_RANGE = { + "Patient ID": ["abcd", "xyz"], + "Heparin Stop": [0, 101], + "Device ID": [1234, 1234], + "Heparin Delivered Volume": [10.1, 10.5], + "Blood Flow Rate": [100, 125], + "Treatment Start DateTime": [1654519251, 1623382321], + "Dialysate Flow Rate": [100, 150], + "Treatment End DateTime": [1654519251, 1623382321], + "Treatment Duration": [70, 75], + "Water Sample Test Result": [0, 1], + "Actual Treatment Duration": [62, 126], + "Dialysate Volume Used": [4.0, 6.0], + "Acid ConcentrateType": [0, 1], + "Prescribed UF Volume": [0.3, 0.5], + "Bicarbonate Concentrate Type": [0, 0], + "Target UF Volume": [10.1, 10.5], + "Potassium Concentration": [60, 75], + "Actual UF Volume": [0.3, 0.5], + "Calcium Concentration": [3, 56], + "Prescribed UF Rate": [0.1, 0.55], + "Bicarbonate Concentration": [14, 50], + "Target UF Rate": [0.2, 0.56], + "Sodium Concentration": [4, 6], + "Actual UF Rate": [0.5, 0.6], + "Dialysate Temperature": [35.0, 35.5], + "Saline Bolus Volume": [300, 250], + "Dialyzer Type": [0, 1], + "Average Blood Flow": [54.3, 67.3], + "Heparin Type": [0, 0], + "Average Dialysate Flow": [0.6, 0.5], + "Average Dialysate Temp": [35.0, 35.5], + "Heparin Bolus Volume": [0.0, 0.1], + "Average Arterial Pressure": [0.0, 11.56], + "Heparin Dispense Rate": [0.0, 0.1], + "Average Venous Pressure": [20.0, 101.45], +} + + + +#standby mode +GOODMORNING_START_TIME_SEC = 0 +GOODEVENING_START_TIME_SEC = 43200 NUM_OF_REQUEST_REJECT_REASONS = 46 #Number of settings change reject codes