Index: shared/scripts/configuration/config.py =================================================================== diff -u -re7b85b1c641f4222746e931b56b04e94a126598a -r15ce38c0762c4c75e1687bdd3262f2da0a7869a0 --- shared/scripts/configuration/config.py (.../config.py) (revision e7b85b1c641f4222746e931b56b04e94a126598a) +++ shared/scripts/configuration/config.py (.../config.py) (revision 15ce38c0762c4c75e1687bdd3262f2da0a7869a0) @@ -90,10 +90,10 @@ 63: "FPGA reports failure reading arterial pressure sensor.", 64: "FPGA reports failure reading venous pressure sensor.", 65: "HD requests DG command with invalid parameter fault.", - 66: "This alarm ID is available for use.", + 66: "HD blood leak sensor set point set failure.", 67: "HD blood pump occlusion self-test failure alarm.", 68: "HD active reservoir recirculation out of range.", - 69: "This alarm ID is available for use.", + 69: "HD blood leak sensor invalid calibration record.", 70: "HD arterial pressure self-test failure alarm.", 71: "HD venous pressure self-test failure alarm.", 72: "HD blood flow meter status check self-test failure alarm.", @@ -109,10 +109,10 @@ 82: "HD syringe pump DAC write failure.", 83: "HD syringe pump is running while the BP is off.", 84: "HD venous pressure sensor not being read." , - 85: "HD venous pressure sensor temperature out of range error.", + 85: "HD pump track latch opened alarm.", 86: "HD BP occlusion sensor not being read.", - 87: "This alarm ID is available for use.", - 88: "This alarm ID is available for use." , + 87: "DG heating invalid calibration record.", + 88: "DG concentrate pumps hall sensor out of range." , 89: "HD BP occlusion sensor error.", 90: "This alarm ID is available for use.", 91: "HD No dialysate flow data receive in the last 3 seconds.", @@ -141,10 +141,10 @@ 114: "HD venous air bubble detector self-test failure.", 115: "DG temperature sensor out of range.", 116: "DG temperature sensor ADC out of range.", - 117: "DG primary heater internal temperature out of range." , - 118: "DG primary heater cold junction temperature out of range." , - 119: "DG trimmer heater internal temperature out of range." , - 120: "DG trimmer heater cold junction temperature out of range." , + 117: "This alarm ID is available for use." , + 118: "This alarm ID is available for use." , + 119: "This alarm ID is available for use." , + 120: "This alarm ID is available for use." , 121: "DG main primary heater voltage out of range.", 122: "DG small primary heater voltage out of range.", 123: "DG trimmer heater voltage out of range.", @@ -167,8 +167,8 @@ 140: "Dialysate generator communication timeout." , 141: "Air trap fill timeout during treatment.", 142: "Blood pump occlusion detected.", - 143: "This alarm ID is available for use.", - 144: "This alarm ID is available for use.", + 143: "DG dialysate temperature sensors drift timeout.", + 144: "DG software configuration record invalid CRC.", 145: "Concentrate conductivity after adding acid out of range alarm." , 146: "Dialysate conductivity out of range." , 147: "DG dialysate generation conductivity fault alarm.", @@ -179,14 +179,14 @@ 152: "Inlet water pressure too low." , 153: "HD prime completed high priority alarm.", 154: "EEPROM operations (read, write, erase) failure.", - 155: "This alarm ID is available for use.", + 155: "DG software configuration record invalid CRC.", 156: "HW usage data (treatment time in HD and total consumed water in DG) failure.", 157: "This alarm ID is available for use." , - 158: "Blood pump failed flow vs motor speed check.", + 158: "This alarm ID is available for use.", 159: "Dialysate inlet pump failed flow vs motor speed check.", 160: "Blood pump rotor speed too high.", - 161: "Blood flow sensor signal strength too low.", - 162: "Dialysate flow sensor signal strength too low.", + 161: "This alarm ID is available for use.", + 162: "This alarm ID is available for use.", 163: "HD sees primary load cell for reservoir 1 change too much too fast.", 164: "HD sees primary load cell for reservoir 2 change too much too fast.", 165: "HD in treatment rinseback operation timeout.",