Index: shared/scripts/configuration/strings.py =================================================================== diff -u -r2961accdbc24fa832a3c6fa3f12fa52ce7938124 -r99a045c3d2fb4c017fe9132d13406830b9469308 --- shared/scripts/configuration/strings.py (.../strings.py) (revision 2961accdbc24fa832a3c6fa3f12fa52ce7938124) +++ shared/scripts/configuration/strings.py (.../strings.py) (revision 99a045c3d2fb4c017fe9132d13406830b9469308) @@ -1,21 +1,58 @@ # -*- coding: utf-8 -*- -#rinseback-setup -RINSE_BACK_SETUP_TEXT = "Rinseback Setup" -RINSEBACK_BUTTON_TEXT = "START RINSEBACK" -END_IMAGE_BUTTON_TEXT = "End" -DECELERATE_BUTTON_TEXT = "Decelerate" -ACCELERATE_BUTTON_TEXT = "Accelerate" -PAUSE_BUTTON_TEXT = "Pause" -RESUME_BUTTON_TEXT = "Resume" -RINSEBACK_TEXT = "Rinseback" -RINSEBACK_COMPLETE_TEXT = "Rinseback Complete" -END_TREATMENT_BUTTON_TEXT = "END TREATMENT" -ADDITIONAL_BUTTON_TEXT = "ADDITIONAL" -ADDITIONAL_RINSEBACK_TEXT = "Additional Rinseback" -RINSEBACK_UNIT = " mL" -RINSEBACK_UNIT_MIN = " mL/min" +########################################################################### +# +# Copyright (c) 2019-2021 Diality Inc. - All Rights Reserved. +# +# THIS CODE MAY NOT BE COPIED OR REPRODUCED IN ANY FORM, IN PART OR IN +# WHOLE, WITHOUT THE EXPLICIT PERMISSION OF THE COPYRIGHT OWNER. +# @file strings.py +# +# @author (last) LTTS +# @date (last) 14-June-2022 +############################################################################ +#pretreatment_screen_bullets +PRE_TREATMENT_SCREENS = ["Create" , "Sample" , "Consumables" , "Disposables" , "Prime" , "Ultrafiltration" , "BP/HR" , "Connection" , "Start"] +POST_TREATMENT_SCREENS = ["Disconnection", "Review", "Disposables", "Disinfection"] + + +#UF treatment +ULTRAFILTRATION_PAUSED_TEXT = "Ultrafiltration Paused" +RESUME_TEXT = "RESUME ULTRAFILTRATION" +EDIT_TEXT = "EDIT ULTRAFILTRATION VOLUME" +TITLE_TEXT = "ULTRAFILTRATION VOLUME (L)" + +#Blood Priming +BLOOD_PRIMING_TEXT = "Blood Priming" +SALINE_UNIT = "mL" + +#main treatment pressure +PRESSURE_TITLE = "PRESSURES" +ARTERIAL_TITLE = "Arterial" +VENOUS_TITLE = "Venous" +VENOUS_UOM = "mmHg" +ARTERIAL_UOM = "mmHg" +LOW_TEXT = "LOW" +HIGH_TEXT = "HIGH" + +#main-treatment heparin +HEPARIN_TEXT = "HEPARIN" +HEPARIN_UNIT = "mL" +HEPARIN_DELIVERY_TEXT = "HEPARIN DELIVERY" +HEPARIN_DELIVERY_OFF_TEXT = "OFF" +HEPARIN_STOP_TEXT = "Delivery Stopped" +HEPARIN_RESUME_DELIVERY_TEXT = "RESUME DELIVERY" +HEPARIN_BOLUS_ACTIVE_TEXT = "Bolus Active" +HEPARIN_BOLUS_DISPENSING_TEXT = "Dispensing Active" +HEPARIN_PAUSE_DELIVERY_TEXT = "PAUSE DELIVERY" +HEPARIN_MAXIMUM_VOLUME_DELIVERED_TEXT = "Maximum Cumulative Heparin Volume Delivered" +HEPARIN_SYRINGE_EMPTY_TEXT = "Syringe Empty" +HEPARIN_DISPENSING_RATE = "Heparin Dispensing Rate" +HEPARIN_BOLUS_VOLUME = "Heparin Bolus Volume" +HEPARIN_STOP_TIME = "Heparin Stop Time" +HEPARIN_TYPE_TITLE = "Heparin Type" + # dictionary of rejection reason from application source code. # message location -> denali-> Headers-> common-> MsgDefs.h REJECTION_REASON = { @@ -64,3 +101,526 @@ 42: "REQUEST_REJECT_REASON_DOOR_NOT_CLOSED", # Door is not closed 43: "REQUEST_REJECT_REASON_SYRINGE_NOT_PRESENT", # Syringe is not present } + +ALARM_ID_AND_MESSAGES = { + 1: "Stuck button POST failure.\nStop or Off button detected to be pressed for at least 1 second during test shortly after power up.", + 2: "HD FPGA POST failure.", + 3: "DG FPGA POST failure.", + 4: "HD Watchdog POST failure.", + 5: "DG Watchdog POST failure.", + 6: "UI communication POST failure.\nUI failed to communicate within a reasonable time after power up.", + 7: "Real-time clock configuration error.", + 8: "HD accelerometer failed POST.", + 9: "DG accelerometer failed POST." , + 10: "RTC or MCU timer inaccurate.", + 11: "DG heaters failed POST.", + 12: "HD firmware image integrity POST test failed.", + 13: "DG firmware image integrity POST test failed.", + 14: "HD blood flow invalid calibration.", + 15: "HD dialysate flow invalid calibration.", + 16: "HD alarm audio failed POST.", + 17: "HD UI POST failed.", + 18: "DG load cells invalid calibration record.", + 19: "DG flow sensors invalid calibration record.", + 20: "DG conductivity sensors invalid calibration record.", + 21: "DG drain line volume invalid calibration record.", + 22: "DG reservoirs invalid calibration record.", + 23: "DG acid concentrate calibration record.", + 24: "DG bicarb concentrate calibration record.", + 25: "DG accelerometer invalid calibration record.", + 26: "HD accelerometer invalid calibration record.", + 27: "HD blood flow invalid calibration record.", + 28: "HD dialyzer flow invalid calibration record.", + 29: "HD heparin force sensor invalid calibration record.", + 30: "HD Software fault.\nSoftware found itself in an unexpected state.", + 31: "Blood pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running.", + 32: "Blood pump failed motor off check.\nMeasured speed while commanded off.", + 33: "Blood pump failed motor direction check.\nMeasured vs commanded.", + 34: "Blood pump failed rotor speed check.\nMismatch with rotor and motor speeds.", + 35: "Dialysis inlet pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running.", + 36: "Dialysis inlet pump failed motor off check.\nMeasured speed while commanded off.", + 37: "Dialysis inlet pump failed motor direction check.\nMeasured vs commanded.", + 38: "Dialysis inlet pump failed rotor speed check.\nMismatch with rotor and motor speeds.", + 39: "Dialysis outlet pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running.", + 40: "Dialysis outlet pump failed motor off check.\nMeasured speed while commanded off.", + 41: "Dialysis outlet pump failed motor direction check.\nMeasured vs commanded.", + 42: "Dialysis outlet pump failed rotor speed check.\nMismatch with rotor and motor speeds.", + 43: "Watchdog expired error.\nWatchdog was not \"pet\" within the appropriate time.", + 44: "User interface communication timeout.", + 45: "Too many bad CRCs detected on received system messages.", + 46: "System message that required acknowledgment was not acknowledged.", + 47: "Ultrafiltration rate is too high error during treatment.", + 48: "Ultrafiltration volume accuracy error during treatment.", + 49: "HD FPGA communication down for too long.", + 50: "FPGA not accepting commanded valve states.", + 51: "Blood pump failed motor speed check.\nMeasured vs commanded.", + 52: "Dialysate inlet pump failed motor speed check.\nMeasured vs commanded.", + 53: "Dialysate outlet pump failed motor speed check.\nMeasured vs commanded.", + 54: "HD critical data integrity check failed.", + 55: "DG critical data integrity check failed.", + 56: "HD accelerometer error (no readings or FPGA reports error).", + 57: "DG accelerometer error (no readings or FPGA reports error).", + 58: "HD valve homing failed.", + 59: "HD valve transition time out.", + 60: "HD valve not functional.", + 61: "HD valve current out of range.", + 62: "HD valve position out of target.", + 63: "FPGA reports failure reading arterial pressure sensor.", + 64: "FPGA reports failure reading venous pressure sensor.", + 65: "HD requests DG command with invalid parameter fault.", + 66: "HD blood leak sensor set point set failure.", + 67: "HD blood pump occlusion self-test failure alarm.", + 68: "HD active reservoir recirculation out of range.", + 69: "HD blood leak sensor invalid calibration record.", + 70: "HD arterial pressure self-test failure alarm." , + 71: "HD venous pressure self-test failure alarm.", + 72: "HD blood flow meter status check self-test failure alarm.", + 73: "HD dialysate flow meter status check self-test failure alarm.", + 74: "HD blood leak detector self-test failure alarm.", + 75: "HD syringe pump self-test failure alarm.", + 76: "HD monitored voltage is out of range.", + 77: "DG monitored voltage is out of range.", + 78: "HD syringe pump direction (from encoder) error.", + 79: "HD syringe pump direction (from controller) error.", + 80: "HD syringe pump fault reported by FPGA.", + 81: "HD syringe pump over travel error.", + 82: "HD syringe pump DAC write failure.", + 83: "HD syringe pump is running while the BP is off.", + 84: "HD venous pressure sensor not being read.", + 85: "HD pump track latch opened alarm.", + 86: "HD BP occlusion sensor not being read.", + 87: "DG heating invalid calibration record.", + 88: "DG concentrate pumps hall sensor out of range.", + 89: "HD BP occlusion sensor error.", + 90: "This alarm ID is available for use.", + 91: "HD No dialysate flow data receive in the last 3 seconds.", + 92: "DG conductivity sensor bad status.", + 93: "This alarm ID is available for use.", + 94: "This alarm ID is available for use.", + 95: "This alarm ID is available for use.", + 96: "Inlet water temperature in high range.", + 97: "Fill conductivity out of range.", + 98: "HD battery communication fault.", + 99: "HD syringe pump stall alarm.", + 100: "HD no cartridge self-test timeout.", + 101: "HD dry self-test timeout.", + 102: "Real-time clock communication error.", + 103: "HD non-volatile calibration group invalid record CRC.", + 104: "Air trap level sensors reporting illegal combination of air/fluid.", + 105: "DG non-volatile system group invalid record CRC.", + 106: "DG inlet water conductivity is greater than threshold.", + 107: "HD reports DG restarted fault.", + 108: "HD syringe pump ADC error.", + 109: "HD syringe pump volume check error.", + 110: "HD syringe pump speed check error.", + 111: "HD syringe pump not stopped in off state error.", + 112: "HD blood leak detector fault.", + 113: "HD arterial air bubble detector self-test failure.", + 114: "HD venous air bubble detector self-test failure.", + 115: "DG temperature sensor out of range.", + 116: "DG temperature sensor ADC out of range.", + 117: "DG primary heater internal temperature out of range.", + 118: "DG primary heater cold junction temperature out of range.", + 119: "DG trimmer heater internal temperature out of range.", + 120: "DG trimmer heater cold junction temperature out of range.", + 121: "DG main primary heater voltage out of range.", + 122: "DG small primary heater voltage out of range.", + 123: "DG trimmer heater voltage out of range.", + 124: "HD end of treatment alarm (high priority).", + 125: "Blood sitting too long after treatment stopped by user alarm (>5 min).", + 126: "HD blood leak detected alarm.", + 127: "Venous pressure too low during treatment." , + 128: "HD venous air bubble detected alarm.", + 129: "HD venous air bubble detected rinseback alarm.", + 130: "Venous pressure too high during treatment.", + 131: "Arterial pressure too low during treatment.", + 132: "Arterial pressure too high during treatment.", + 133: "DG fluid leak detected alarm.", + 134: "HD fluid leak detected alarm." , + 135: "HD experienced large acceleration.", + 136: "DG experienced large acceleration.", + 137: "HD tilt exceeds maximum.", + 138: "DG tilt exceeds maximum.", + 139: "HD AC power lost alarm.", + 140: "Dialysate generator communication timeout.", + 141: "Air trap fill timeout during treatment.", + 142: "Blood pump occlusion detected.", + 143: "DG dialysate temperature sensors drift timeout.", + 144: "DG software configuration record invalid CRC.", + 145: "Concentrate conductivity after adding acid out of range alarm.", + 146: "Dialysate conductivity out of range.", + 147: "Wait for the DG to produce dialysate.", + 148: "Inlet water temperature too high.", + 149: "Alarm ID available for use.", + 150: "Inlet water conductivity in high range.", + 151: "Inlet water conductivity in low range.", + 152: "Inlet water pressure in low range.", + 153: "HD prime completed high priority alarm.", + 154: "EEPROM operations (read, write, erase) failure.", + 155: "DG software configuration record invalid CRC.", + 156: "HW usage data (treatment time in HD and total consumed water in DG) failure.", + 157: "DG chemical disinfect prime acid line timeout.", + 158: "Inlet water temperature is in the low range.", + 159: "Dialysate inlet pump failed flow vs motor speed check.", + 160: "Blood pump rotor speed too high.", + 161: "This alarm ID is available for use.", + 162: "This alarm ID is available for use.", + 163: "HD sees primary load cell for reservoir 1 change too much too fast.", + 164: "HD sees primary load cell for reservoir 2 change too much too fast.", + 165: "HD in treatment rinseback operation timeout.", + 166: "HD in treatment re-circ sub-mode for too long.", + 167: "HD cartridge door opened alarm.", + 168: "HD active reservoir depletion timeout.", + 169: "Dialysate flow rate out of range.", + 170: "HD syringe empty alarm.", + 171: "HD syringe pump occlusion alarm.", + 172: "HD syringe pump not enough Heparin alarm.", + 173: "HD arterial air bubble detected alarm.", + 174: "HD arterial air bubble detected rinseback alarm.", + 175: "HD pump direction status error.", + 176: "HD active reservoir is full during treatment and DG not ready to switch reservoirs.", + 177: "DG software fault.\nSoftware found itself in an unexpected state.", + 178: "HD communication timeout.", + 179: "DG FPGA communication down for too long.", + 180: "DG load cell ADC error.", + 181: "DG load cells weight out of range for tare.", + 182: "DG load cells invalid calibration.", + 183: "DG invalid load cell value.", + 184: "Inlet or Outlet UV reactor not healthy.", + 185: "DG fan RPM out of range.", + 186: "DG concentrate pump fault.", + 187: "DG concentrate pump CP1 speed control error.", + 188: "DG concentrate pump CP2 speed control error.", + 189: "DG drain pump RPM out of range.", + 190: "DG drain pump off fault.", + 191: "DG flow rate out of upper range.", + 192: "DG flow rate out of lower range.", + 193: "RO pump flow rate out of range.", + 194: "DG RO pump duty cycle out of range.", + 195: "DG RO pump pressure out of range.", + 196: "DG temperature sensor error flag fault.", + 197: "DG temperature sensors ADC fault.", + 198: "DG heaters cold junction temperature out of range.", + 199: "DG heaters fault.", + 200: "DG thermistors/sensors temperature out of range.", + 201: "Inlet water quality is bad (temperature, conductivity, pressure).", + 202: "Inlet water pressure fault.", + 203: "Pressure sensor fault.", + 204: "RO rejection ratio out of range.", + 205: "Conductivity sensor fault.", + 206: "DG dialysate fill runs out of time.", + 207: "DG flow meter check failure alarm.", + 208: "DG primary heater on with no flow time out.", + 209: "DG drain circulation line timeout.", + 210: "HD battery pack detected an error.", + 211: "Blood sitting too long warning (>4 min).", + 212: "HD end of treatment alarm (user not acting to end treatment).", + 213: "HD prime completed medium priority alarm.", + 214: "HD Saline bolus volume check failure.", + 215: "HD rinseback volume check failure.", + 216: "HD end treatment sub-mode timeout alarm.", + 217: "HD blood prime volume check failure.", + 218: "HD syringe detected alarm.", + 219: "HD syringe pump syringe removed alarm.", + 220: "HD battery pack SOC is too low.", + 221: "HD Saline bag is empty.", + 222: "HD dialysate temperature too high alarm.", + 223: "HD dialysate temperature too low alarm.", + 224: "Treatment stopped by user action.", + 225: "HD end of treatment warning.", + 226: "HD prime completed low priority alarm.", + 227: "HD prime out of time alarm.", + 228: "HD time out on prime sub-mode purge air state.", + 229: "HD prime dialysate dialyzer time out alarm.", + 230: "HD prime dialysate bypass time out alarm.", + 231: "HD pre-treatment mode dry self-tests failure.", + 232: "HD pre-treatment mode wet self-tests failure.", + 233: "RTC battery low.", + 234: "RTC (i.e read time) or RAM operations failure (read or write).", + 235: "HD in treatment stopped sub-mode after rinseback completed (no escalation).", + 236: "HD needs new cartridge to be installed.", + 237: "HD prime saline dialyzer time out alarm.", + 238: "HD no cartridge loaded or installed improperly alarm.", + 239: "HD fail to remove cartridge alarm.", + 240: "Bicarb conductivity out of range during bicarb pump check alarm.", + 241: "DG reservoir drain time out.", + 242: "DG reservoir fill time out.", + 243: "DG reservoir leak time out.", + 244: "DG temperature sensors difference out of range.", + 245: "DG heat disinfect target temperature time out (could not reach to temperature).", + 246: "DG heat disinfect inlet pressure and temperature sensors out of range.", + 247: "DG heat disinfect inlet conductivity and temperature out of range.", + 248: "DG chemical disinfect could not reach to target temperature.", + 249: "DG chemical disinfect inlet pressure and temperature sensors out of range.", + 250: "DG chemical disinfect inlet conductivity and temperature out of range.", + 251: "HD invalid system record.", + 252: "HD invalid service record.", + 253: "DG invalid system record.", + 254: "DG invalid service record.", + 255: "HD and UI software builds are not compatible.", + 256: "HD and DG software builds are not compatible.", + 257: "DG FPGA power out timeout.", + 258: "HD FPGA power out timeout.", + 259: "HD temperatures out of range.", + 260: "UI POST Application Integrity (Sha256Sum) failure.", + 261: "UI POST CANBus failure.", + 262: "UI POST Display failure.", + 263: "UI POST Touch failure.", + 264: "UI POST SD-Card failure.", + 265: "UI POST RTC failure.", + 266: "UI POST WiFi failure.", + 267: "UI POST Bluetooth failure.", + 268: "UI POST Ethernet failure.", + 269: "UI POST Sound failure.", + 270: "HD POST Safety Shutdown failure.", + 271: "DG POST Safety Shutdown failure.", + 272: "HD Fan RPM out of range.", + 273: "HD measured blood pump flow rate is out of range.", + 274: "HD measured dialysate inlet pump flow rate is out of range.", + 275: "HD arterial pressure sensor is reading out of range.", + 276: "HD venous pressure sensor is reading out of range.", + 277: "HD BP occlusion sensor is reading out of range.", + 278: "HD active reservoir weight out of range.", + 279: "DG dialysate drain time out.", + 280: "HD arterial pressure sensor read timeout error.", + 281: "Acid concentration bottle low volume alarm.", + 282: "Bicarbonate concentration bottle low volume alarm.", + 283: "DG load cells weight out of range.", + 284: "DG load cells primary/back up drift out of range.", + 285: "HD treatment recirculate timeout warning.", + 286: "HD treatment rinseback complete timeout warning.", + 287: "HD processor clock speed checks against FPGA clock failure.", + 288: "DG trimmer heater on with flow timeout.", + 289: "DG dialysate or concentrate caps not closed." + } + +#Alarm List +UNDEFINED_ALARM_ID_MSG = "ALARM_ID_UNDEFINED" +ALARM_TITLE = "Alarm" +ALARM_LIST_TITLE = "Alarm list" +ALARM_PRIORITIES = {1: "LOW", 2: "MEDIUM", 3: "HIGH"} + +ALARM_PRIORITY_OPTIONS = { + 0 : 'ALARM_PRIORITY_NONE' , + 1 : 'ALARM_PRIORITY_LOW' , + 2 : 'ALARM_PRIORITY_MEDIUM', + 3 : 'ALARM_PRIORITY_HIGH', +} + +#Setting +EXPORT_TEXT ="Export" +DEVICE_SETTINGS_TEXT = "Device Settings" +DEVICE_SETTINGS_SCREEN_PARAMETER = ["Information", "Volume And Brightness", "Wi-Fi", "Bluetooth Cuff", "Dialysate Generator Settings", "Services"] + +#UF treatment +LIQUID_UNIT = "mL" + +#create custom treatment +TREATMENT_TITLE = "Create a Custom Treatment" +CONFIRM_TREATMENT_TITLE = "Confirm Treatment" +PRESCRIPTION_TITLE = "PRESCRIPTION" +OPERATING_PARAMETERS_TITLE = "OPERATING PARAMETERS" +PATIENT_ID_TEXT = "Patient ID" +BLOOD_FLOW_RATE = "Blood Flow Rate" +DIALYSATE_FLOW_RATE = "Dialysate Flow Rate" +DURATION = "Duration" +SALINE_BOLUS_VOLUME = "Saline Bolus Volume" + +#main treatment screen +VITALS_TITLE = "VITALS" +HEART_RATE_TITLE = "Heart Rate" +BLOOD_PRESSURE_TITLE = "Blood Pressure" +BLOOD_PRESSURE_UNIT = "mmHg" +HEART_RATE_UNIT = "BPM" + +PATIENT_ID = "demopatientid" +SALINE_BOLUS_TITLE = "Saline Bolus" +ACID_CONCENTRATE_TITLE = "Acid Concentrate" +BICARBONATE_CONCENTRATE_TITLE = "Bicarbonate Concentrate" +DIALYZER_TYPE_TITLE = "Dialyzer Type" +DIALYSATE_TEMPERATURE = "Dialysate Temperature" +BLOOD_PRESSURE_MEASUREMENT_INTERVAL = "Blood Pressure Measurement Interval" +RINSEBACK_FLOW_RATE = "Rinseback Flow Rate" +OFF_TEXT = "OFF" +BACK_TEXT = "BACK" +CONTINUE_TEXT = "CONTINUE" +CREATE_TREATMENT_PARAMETERS = ["Blood Flow Rate", "Dialysate Flow Rate", "Duration","Heparin Dispensing Rate", + "Heparin Bolus Volume","Heparin Stop Time", "Saline Bolus", "Dialysate Temperature", + "Blood Pressure Measurement Interval", "Rinseback Flow Rate"] + + +PRESCRIPTION_DETAILS = { + "Blood Flow Rate": "mL/min", "Dialysate Flow Rate": "mL/min", + "Duration": "min", "Heparin Dispensing Rate": "mL/hr", + "Heparin Bolus Volume": "mL", "Heparin Stop Time": "min", + "Saline Bolus Volume": "mL", + "Dialysate Temperature": "°C", "Arterial Pressure Limit Low": "mmHg", + "Arterial Pressure Limit High": "mmHg","Blood Pressure Measure Interval":"min", + "Rinseback Rate" : "mL/min", "Venous Pressure Limit High": "mmHg", + "Venous Pressure Limit Low": "mmHg" +} + +#Time_Duration +TREATMENT_PAUSED_TEXT = "Treatment Paused" + +#pre-treatment +CONSUMABLE_SELF_TEST_TEXT = "Consumables Self Test" +BICARB_PUMP_CHECK_TEXT = "BiCarb Pump Check" +ACID_PUMP_CHECK_TEXT = "Acid Pump Check" +SELF_TEST_COMPLETE_TEXT = "Self Test Complete!" +BUSY = "Busy" +CHECK = "Check" +BEGIN_PRIME_TITLE = "Begin Prime" +PRIMING_TITLE = "Priming" +SYSTEM_SELF_TEST_TITLE = "System Self Test" +FILTER_FLUSH_TITLE = "Filter Flush" + +#Pre-Treatment Disposables +NEXT_BUTTON_TEXT = "NEXT" +BACK_BUTTON_TEXT = "BACK" +CONFIRM_BUTTON_TEXT = "CONFIRM" + +#Pre_treatment_water_sample +SAMPLE_TEXT = "Sample" +CREATE_TEXT = "Create" +WATER_SAMPLE_BUTTON_TEXT = "WATER SAMPLE" +PASS_TEXT = "PASS" +FAIL_TEXT = "FAIL" +OK_TEXT = "OK" + +#Vitals & pretreatment_patient_connection +SYSTOLIC_TEXT = "systolic" +DIASTOLIC_TEXT = "diastolic" + +#priming +TEST_DRY_STEPS = ["Used Cartridge Check", "Occlusion Sensors Check", "Pressure Sensors Check", "Syringe Pump Check"] +PRIMING_STEPS = ["Blood Circuit Priming", "Dialysate Circuit Priming", "Wet Self Tests"] +SELF_TEST_COMPLETION_MSG = "Self Test Complete!" +PRIMING_COMPLETE_MSG = "Priming Complete!" + +#main_treatment_flows +FLOW_UNIT = "mL/min" +BLOOD_FLOW_TEXT = "blood" +DIALYSATE_FLOW_TEXT = "dialysate" + +#tst_treatment_monitoring +FLOWS_TEXT = "FLOWS" +BLOOD_UNIT = "mL/min" +DIALYSATE_TEXT = "Dialysate" +BLOOD_TEXT = "Blood" +VITALS_TEXT = "VITALS" +BLOOD_PRESSURE_TEXT = "mmHg" +HEARTRATE_UNIT = "BPM" +PRESSURE_TEXT = "PRESSURE (mmHg)" +ARTEREAL_TEXT = "Arterial" +VENOUS_TEXT = "Venous" +TIME_DURATION_TEXT = "Time Remaining" +ULTRAFILTERATION_TEXT = "ULTRAFILTRATION VOLUME (L)" +SALINE_BOLUS = "SALINE BOLUS" +VOLUME_DELIVERED = "Volume Delivered" +CUMULATIVE_DELIVERED = "Cumulative Delivered" + +#post-treatment +PATIENT_DISCONNECTION_TEXT = "Patient Disconnection" +REVIEW_TEXT = "Review" +PATIENT_DISCONNECTION_CONFIRM_BUTTON_TEXT = "CONFIRM" +DISPOSABLE_TEXT = "Disposables" +NEXT_TEXT = "NEXT" +BACK_TEXT = "BACK" +CONFIRM_TEXT = "CONFIRM" +DISPOSABLES_REMOVAL_TEXT = "Disposables Removal" + +#post treatment review +TREATMENT_REVIEW_TITLE_TEXT = "Treatment Review" +POST_TREATMENT_REVIEW_SCREEN_UNITS = { + "Patient ID" : "", + "Heparin Stop" : "min", + "Device ID" : "", + "Heparin Delivered Volume": "mL", + "Blood Flow Rate" : "mL/min", + "Treatment Start DateTime" : "", + "Dialysate Flow Rate" : "mL/min", + "Treatment End DateTime" : "", + "Treatment Duration" : "min", + "Water Sample Test Result": "", + "Actual Treatment Duration":"min", + "Dialysate Volume Used" : "L", + "Acid ConcentrateType" : "", + "Prescribed UF Volume" : "L", + "Bicarbonate Concentrate Type" : "", + "Target UF Volume" : "L", + "Potassium Concentration" : "mEg/L", + "Actual UF Volume" : "L", + "Calcium Concentration" :"mEg/L", + "Prescribed UF Rate" : "mL/min", + "Bicarbonate Concentration" : "mEg/L", + "Target UF Rate": "mL/min", + "Sodium Concentration" : "mEg/L", + "Actual UF Rate": "mL/min", + "Dialysate Temperature" :"°C", + "Saline Bolus Volume" : "mL", + "Dialyzer Type" : "", + "Average Blood Flow" : "mL/min", + "Heparin Type" : "IU/mL", + "Average Dialysate Flow" : "mL/min", + "Heparin Concentration" : "IU/mL", + "Average Dialysate Temp" : "°C", + "Heparin Bolus Volume": "mL", + "Average Arterial Pressure" : "mmHg", + "Heparin Dispense Rate" : "mL/hr", + "Average Venous Pressure" : "mmHg", + } + +#Information +INFORMATION_TITLES = ["Information", "Versions"] +INFORMATION_PARAMETERS = ["Information", "UI Version", "HD Version", "HD FPGA Version", "HD Serial Number", "DG Version", "DG FPGA Version", "DG Serial Number"] +SERIVCES_TITLE = "Services" +SERVICES_PARAMETERS = ["HD Last Service Date", "HD Next Service Date", "DG Last Service Date", "DG Next Service Date"] + + +#volume and brightness +VOLUME_AND_BRIGHTNESS_TEXT = "Volume And Brightness" +BRIGHTNESS_TEXT = "Brightness" +ALARM_VOLUME_TEXT = "Alarm Volume" +UNIT_OF_VOLUME_AND_BRIGHTNESS = "%" + +#services +SHUTDOWN_TEXT = "SHUTDOWN" + +# pretreatment_patient_connection & ui logs +ACK_REQ_STATUS = 'Ack Req' +ACK_BAK_STATUS = 'Ack Bak' +PATIENT_CONNECTION_TEXT = "Patient Connection" +UF_VOLUME_TEXT = "Ultrafiltration Volume (L)" +UF_TITLE_TEXT = "Ultrafiltration Setup" +BP_HR_TEXT = "BP/HR" +SKIP_TEXT = "SKIP" +TUTORIAL_TEXT = { + 0 : "Wash your hands and establish vascular access per your clinic's instructions.", + 1 : "Pinch arterial clamp and venous clamp on located on the cartridge patient lines.", + 2 : "Remove arterial and venous shunt.", + 3 : "Connect arterial and venous cartridge lines to your patient access lines." +} + +#End treatment +RINSEBACK_BUTTON_TEXT = "START RINSEBACK" +END_TREATMENT_COMPLETE_STATE_TEXT = "Treatment Complete" +END_TREATMENT_COMPLETE_PAUSED_STATE_TEXT = "Treatment Complete Paused" + +#rinseback-setup +RINSE_BACK_SETUP_TEXT = "Rinseback Setup" +RINSEBACK_BUTTON_TEXT = "START RINSEBACK" +END_IMAGE_BUTTON_TEXT = "End" +DECELERATE_BUTTON_TEXT = "Decelerate" +ACCELERATE_BUTTON_TEXT = "Accelerate" +PAUSE_BUTTON_TEXT = "Pause" +RESUME_BUTTON_TEXT = "Resume" +RINSEBACK_TEXT = "Rinseback" +RINSEBACK_COMPLETE_TEXT = "Rinseback Complete" +END_TREATMENT_BUTTON_TEXT = "END TREATMENT" +ADDITIONAL_BUTTON_TEXT = "ADDITIONAL" +ADDITIONAL_RINSEBACK_TEXT = "Additional Rinseback" +RINSEBACK_UNIT = " mL" +RINSEBACK_UNIT_MIN = " mL/min" + +