Index: shared/scripts/configuration/strings.py =================================================================== diff -u -r71574ed67e513579e7f0ba2916a6b922a9887e56 -rb59ddcfda38f2fc9a1d1af409a545b4e1db452b7 --- shared/scripts/configuration/strings.py (.../strings.py) (revision 71574ed67e513579e7f0ba2916a6b922a9887e56) +++ shared/scripts/configuration/strings.py (.../strings.py) (revision b59ddcfda38f2fc9a1d1af409a545b4e1db452b7) @@ -5,14 +5,101 @@ # # THIS CODE MAY NOT BE COPIED OR REPRODUCED IN ANY FORM, IN PART OR IN # WHOLE, WITHOUT THE EXPLICIT PERMISSION OF THE COPYRIGHT OWNER. +# @file strings.py # -# @file utils.py -# -# @author (last) Joseph varghese +# @author (last) LTTS # @date (last) 18-Jan-2022 -# ############################################################################ +PRE_TREATMENT_SCREENS = ["Create" , "Sample" , "Consumables" , "Disposables" , "Prime" , "Ultrafiltration" , "BP/HR" , "Connection" , "Start"] +POST_TREATMENT_SCREENS = ["Disconnection", "Review", "Disposables", "Disinfection"] + +BLOOD_PRIMING_TEXT = "Blood Priming" +SALINE_UNIT = "mL" +BLOOD_PRIMING_DEFAULT_VALUE = "0 mL" +ULTRAFILTRATION_PAUSED_TEXT = "Ultrafiltration Paused" +RESUME_TEXT = "RESUME ULTRAFILTRATION" +EDIT_TEXT = "EDIT ULTRAFILTRATION VOLUME" +TITLE_TEXT = "ULTRAFILTRATION VOLUME (L)" + +BLOOD_PRIMING_TEXT = "Blood Priming" +SALINE_UNIT = "mL" +BLOOD_PRIMING_DEFAULT_VALUE = "0 mL" + +#main treatment pressure +PRESSURE_TITLE = "PRESSURES" +ARTERIAL_TITLE = "Arterial" +VENOUS_TITLE = "Venous" +VENOUS_UOM = "mmHg" +ARTERIAL_UOM = "mmHg" +LOW_TEXT = "LOW" +HIGH_TEXT = "HIGH" + + +#main-treatment heparin +HEPARIN_UNIT = "mL" +HEPARIN_DELIVERY_TEXT = "HEPARIN DELIVERY" +HEPARIN_DELIVERY_OFF_TEXT = "OFF" +HEPARIN_STOP_TEXT = "Delivery Stopped" +HEPARIN_RESUME_DELIVERY_TEXT = "RESUME DELIVERY" +HEPARIN_BOLUS_ACTIVE_TEXT = "Bolus Active" +HEPARIN_BOLUS_DISPENSING_TEXT = "Dispensing Active" +HEPARIN_PAUSE_DELIVERY_TEXT = "PAUSE DELIVERY" +HEPARIN_MAXIMUM_VOLUME_DELIVERED_TEXT = "Maximum Cumulative Heparin Volume Delivered" +HEPARIN_SYRINGE_EMPTY_TEXT = "Syringe Empty" + +#tst_treatment_saline_data +SALINE_UNIT = "mL" + +# dictionary of rejection reason from application source code. +# message location -> denali-> Headers-> common-> MsgDefs.h +REJECTION_REASON = { + 0: "No Active Alarm List", + 1: "REQUEST_REJECT_REASON_NOT_ALLOWED_IN_CURRENT_MODE", # Request is not allowed in the current operating mode + 2: "REQUEST_REJECT_REASON_TIMEOUT_WAITING_FOR_USER_CONFIRM", # Validated request was not confirmed by user in reasonable time + 3: "REQUEST_REJECT_REASON_NOT_IN_TREATMENT_MODE", # Request is not allowed if not in treatment mode + 4: "REQUEST_REJECT_REASON_INVALID_TREATMENT_STATE", # Request is not allowed in current treatment state + 5: "REQUEST_REJECT_REASON_TREATMENT_TOO_CLOSE_TO_FINISHED", # Request is not allowed so near end of treatment + 6: "REQUEST_REJECT_REASON_TREATMENT_TIME_OUT_OF_RANGE", # Treatment duration is out of range + 7: "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_CURRENT", # Treatment time change is less than currently elapsed treatment time + 8: "REQUEST_REJECT_REASON_BLOOD_FLOW_OUT_OF_RANGE", # Blood flow is out of range + 9: "REQUEST_REJECT_REASON_DIAL_FLOW_OUT_OF_RANGE", # Dialysate flow is out of range + 10: "REQUEST_REJECT_REASON_DIAL_VOLUME_OUT_OF_RANGE", # Dialysate flow rate or treatment duration causes dialysate volume to exceed limit + 11: "REQUEST_REJECT_REASON_UF_VOLUME_OUT_OF_RANGE", # Ultrafiltration volume is out of range + 12: "REQUEST_REJECT_REASON_UF_RATE_OUT_OF_RANGE", # Ultrafiltration rate is out of range + 13: "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_MINIMUM", # Treatment time change is less than minimum treatment time + 14: "REQUEST_REJECT_REASON_UF_NOT_IN_PROGESS", # Ultrafiltration is not currently in progress + 15: "REQUEST_REJECT_REASON_UF_NOT_PAUSED", # Ultrafiltration is not currently paused + 16: "REQUEST_REJECT_REASON_SALINE_BOLUS_IN_PROGRESS", # A saline bolus is in progress + 17: "REQUEST_REJECT_REASON_PARAM_OUT_OF_RANGE", # A treatment parameter is out of range + 18: "REQUEST_REJECT_REASON_HEPARIN_PRESTOP_EXCEEDS_DURATION", # The Heparin pre-stop setting is greater than the treatment duration + 19: "REQUEST_REJECT_REASON_ARTERIAL_PRESSURE_LOW_VS_HIGH", # Arterial pressure low and high alarm limits are not inconsistent + 20: "REQUEST_REJECT_REASON_VENOUS_PRESSURE_LOW_VS_HIGH", # Venous pressure low and high alarm limits are inconsistent + 21: "REQUEST_REJECT_REASON_SALINE_MAX_VOLUME_REACHED", # Saline bolus volume maximum has been reached - no more saline allowed + 22: "REQUEST_REJECT_REASON_SALINE_BOLUS_NOT_IN_PROGRESS", # A saline bolus is not in progress + 23: "REQUEST_REJECT_REASON_ACTION_DISABLED_IN_CURRENT_STATE", # Requested user action is disabled in current state + 24: "REQUEST_REJECT_REASON_ALARM_IS_ACTIVE", # Requested user action not allowed while alarm is active + 25: "REQUEST_REJECT_REASON_INVALID_COMMAND", # Requested user action invalid + 26: "REQUEST_REJECT_REASON_TREATMENT_IS_COMPLETED", # The treatment has been completed + 27: "REQUEST_REJECT_REASON_ADDL_RINSEBACK_MAX_VOLUME_REACHED", # Rinseback additional volume maximum has been reached - no more additional rinsebacks allowed + 28: "REQUEST_REJECT_REASON_UF_VOLUME_NOT_SET", # Ultrafiltration volume is not set yet + 29: "REQUEST_REJECT_REASON_NO_PATIENT_CONNECTION_CONFIRM", # The user has not confirmed patient connection + 30: "REQUEST_REJECT_REASON_HEPARIN_PAUSE_INVALID_IN_THIS_STATE", # Heparin cannot be paused if not currently deliverying Heparin + 31: "REQUEST_REJECT_REASON_HEPARIN_NOT_PAUSED", # Heparin cannot be resumed if not paused + 32: "REQUEST_REJECT_REASON_DG_COMM_LOST", # Treatment cannot initiate if DG comm is lost + 33: "REQUEST_REJECT_REASON_DRAIN_NOT_COMPLETE", # Post-treatment reservoirs drain not complete + 34: "REQUEST_REJECT_REASON_DG_NOT_IN_STANDBY_IDLE_STATE", # Treatment cannot initiate if DG is not in standby idle state + 35: "REQUEST_REJECT_REASON_INVALID_REQUEST_FORMAT", # Request message not formatted properly + 36: "REQUEST_REJECT_REASON_INVALID_DATE_OR_TIME", # Given date/time is invalid + 37: "REQUEST_REJECT_REASON____AVAILABLE_1", # Not used - available for use + 38: "REQUEST_REJECT_REASON_BATTERY_IS_NOT_CHARGED", # Battery does not have enough charge to start treatment + 39: "REQUEST_REJECT_REASON_RINSEBACK_NOT_COMPLETED", # Cannot move on to recirculate without completing full rinseback. + 40: "REQUEST_REJECT_REASON_RESERVOIR_ONE_IS_NOT_READY", # Reservoir one fill is not complete + 41: "REQUEST_REJECT_REASON_PUMP_TRACK_NOT_CLOSED", # Pump track is not ready / closed + 42: "REQUEST_REJECT_REASON_DOOR_NOT_CLOSED", # Door is not closed + 43: "REQUEST_REJECT_REASON_SYRINGE_NOT_PRESENT", # Syringe is not present + } + ALARM_ID_AND_MESSAGES = { 1: "Stuck button POST failure.\nStop or Off button detected to be pressed for at least 1 second during test shortly after power up.", 2: "HD FPGA POST failure.", @@ -305,68 +392,311 @@ 289: "DG dialysate or concentrate caps not closed." } -ALARM_PRIORITIES = {1: "LOW", 2: "MEDIUM", 3: "HIGH"} - +#Alarm List +UNDEFINED_ALARM_ID_MSG = "ALARM_ID_UNDEFINED" +ALARM_TITLE = "Alarm" ALARM_LIST_TITLE = "Alarm list" +ALARM_PRIORITIES = {1: "LOW", 2: "MEDIUM", 3: "HIGH"} -REJECTION_REASON = { - 0: "No Active Alarm List", - 1: "REQUEST_REJECT_REASON_NOT_ALLOWED_IN_CURRENT_MODE", # Request is not allowed in the current operating mode - 2: "REQUEST_REJECT_REASON_TIMEOUT_WAITING_FOR_USER_CONFIRM", # Validated request was not confirmed by user in reasonable time - 3: "REQUEST_REJECT_REASON_NOT_IN_TREATMENT_MODE", # Request is not allowed if not in treatment mode - 4: "REQUEST_REJECT_REASON_INVALID_TREATMENT_STATE", # Request is not allowed in current treatment state - 5: "REQUEST_REJECT_REASON_TREATMENT_TOO_CLOSE_TO_FINISHED", # Request is not allowed so near end of treatment - 6: "REQUEST_REJECT_REASON_TREATMENT_TIME_OUT_OF_RANGE", # Treatment duration is out of range - 7: "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_CURRENT", # Treatment time change is less than currently elapsed treatment time - 8: "REQUEST_REJECT_REASON_BLOOD_FLOW_OUT_OF_RANGE", # Blood flow is out of range - 9: "REQUEST_REJECT_REASON_DIAL_FLOW_OUT_OF_RANGE", # Dialysate flow is out of range - 10: "REQUEST_REJECT_REASON_DIAL_VOLUME_OUT_OF_RANGE", # Dialysate flow rate or treatment duration causes dialysate volume to exceed limit - 11: "REQUEST_REJECT_REASON_UF_VOLUME_OUT_OF_RANGE", # Ultrafiltration volume is out of range - 12: "REQUEST_REJECT_REASON_UF_RATE_OUT_OF_RANGE", # Ultrafiltration rate is out of range - 13: "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_MINIMUM", # Treatment time change is less than minimum treatment time - 14: "REQUEST_REJECT_REASON_UF_NOT_IN_PROGESS", # Ultrafiltration is not currently in progress - 15: "REQUEST_REJECT_REASON_UF_NOT_PAUSED", # Ultrafiltration is not currently paused - 16: "REQUEST_REJECT_REASON_SALINE_BOLUS_IN_PROGRESS", # A saline bolus is in progress - 17: "REQUEST_REJECT_REASON_PARAM_OUT_OF_RANGE", # A treatment parameter is out of range - 18: "REQUEST_REJECT_REASON_HEPARIN_PRESTOP_EXCEEDS_DURATION", # The Heparin pre-stop setting is greater than the treatment duration - 19: "REQUEST_REJECT_REASON_ARTERIAL_PRESSURE_LOW_VS_HIGH", # Arterial pressure low and high alarm limits are not inconsistent - 20: "REQUEST_REJECT_REASON_VENOUS_PRESSURE_LOW_VS_HIGH", # Venous pressure low and high alarm limits are inconsistent - 21: "REQUEST_REJECT_REASON_SALINE_MAX_VOLUME_REACHED", # Saline bolus volume maximum has been reached - no more saline allowed - 22: "REQUEST_REJECT_REASON_SALINE_BOLUS_NOT_IN_PROGRESS", # A saline bolus is not in progress - 23: "REQUEST_REJECT_REASON_ACTION_DISABLED_IN_CURRENT_STATE", # Requested user action is disabled in current state - 24: "REQUEST_REJECT_REASON_ALARM_IS_ACTIVE", # Requested user action not allowed while alarm is active - 25: "REQUEST_REJECT_REASON_INVALID_COMMAND", # Requested user action invalid - 26: "REQUEST_REJECT_REASON_TREATMENT_IS_COMPLETED", # The treatment has been completed - 27: "REQUEST_REJECT_REASON_ADDL_RINSEBACK_MAX_VOLUME_REACHED", # Rinseback additional volume maximum has been reached - no more additional rinsebacks allowed - 28: "REQUEST_REJECT_REASON_UF_VOLUME_NOT_SET", # Ultrafiltration volume is not set yet - 29: "REQUEST_REJECT_REASON_NO_PATIENT_CONNECTION_CONFIRM", # The user has not confirmed patient connection - 30: "REQUEST_REJECT_REASON_HEPARIN_PAUSE_INVALID_IN_THIS_STATE", # Heparin cannot be paused if not currently deliverying Heparin - 31: "REQUEST_REJECT_REASON_HEPARIN_NOT_PAUSED", # Heparin cannot be resumed if not paused - 32: "REQUEST_REJECT_REASON_DG_COMM_LOST", # Treatment cannot initiate if DG comm is lost - 33: "REQUEST_REJECT_REASON_DRAIN_NOT_COMPLETE", # Post-treatment reservoirs drain not complete - 34: "REQUEST_REJECT_REASON_DG_NOT_IN_STANDBY_IDLE_STATE", # Treatment cannot initiate if DG is not in standby idle state - 35: "REQUEST_REJECT_REASON_INVALID_REQUEST_FORMAT", # Request message not formatted properly - 36: "REQUEST_REJECT_REASON_INVALID_DATE_OR_TIME", # Given date/time is invalid - 37: "REQUEST_REJECT_REASON____AVAILABLE_1", # Not used - available for use - 38: "REQUEST_REJECT_REASON_BATTERY_IS_NOT_CHARGED", # Battery does not have enough charge to start treatment - 39: "REQUEST_REJECT_REASON_RINSEBACK_NOT_COMPLETED", # Cannot move on to recirculate without completing full rinseback. - 40: "REQUEST_REJECT_REASON_RESERVOIR_ONE_IS_NOT_READY", # Reservoir one fill is not complete - 41: "REQUEST_REJECT_REASON_PUMP_TRACK_NOT_CLOSED", # Pump track is not ready / closed - 42: "REQUEST_REJECT_REASON_DOOR_NOT_CLOSED", # Door is not closed - 43: "REQUEST_REJECT_REASON_SYRINGE_NOT_PRESENT", # Syringe is not present - } - -UNDEFINED_ALARM_ID_MSG = "ALARM_ID_UNDEFINED" -ALARM_TITLE = "Alarm" - ALARM_PRIORITY_OPTIONS = { 0 : 'ALARM_PRIORITY_NONE' , 1 : 'ALARM_PRIORITY_LOW' , 2 : 'ALARM_PRIORITY_MEDIUM', 3 : 'ALARM_PRIORITY_HIGH', } +#main-treatment heparin +HEPARIN_TEXT = "HEPARIN" +HEPARIN_UNIT = "mL" +HEPARIN_DELIVERY_TEXT = "HEPARIN DELIVERY" +HEPARIN_DELIVERY_OFF_TEXT = "OFF" +HEPARIN_STOP_TEXT = "Delivery Stopped" +HEPARIN_RESUME_DELIVERY_TEXT = "RESUME DELIVERY" +HEPARIN_BOLUS_ACTIVE_TEXT = "Bolus Active" +HEPARIN_BOLUS_DISPENSING_TEXT = "Dispensing Active" +HEPARIN_PAUSE_DELIVERY_TEXT = "PAUSE DELIVERY" +HEPARIN_MAXIMUM_VOLUME_DELIVERED_TEXT = "Maximum Cumulative Heparin Volume Delivered" +HEPARIN_SYRINGE_EMPTY_TEXT = "Syringe Empty" +HEPARIN_DISPENSING_RATE = "Heparin Dispensing Rate" +HEPARIN_BOLUS_VOLUME = "Heparin Bolus Volume" +HEPARIN_STOP_TIME = "Heparin Stop Time" +HEPARIN_TYPE_TITLE = "Heparin Type" + +#Setting +EXPORT_TEXT ="Export" +DEVICE_SETTINGS_TEXT = "Device Settings" +DEVICE_SETTINGS_SCREEN_PARAMETER = ["Information", "Volume And Brightness", "Wi-Fi", "Bluetooth Cuff", "Dialysate Generator Settings", "Services"] +SettingsHome_Treatment_Text = "Treatment" +SettingsHome_Manager_Text = "Manager" +SettingsHome_Settings_Text = "Settings" + +#UF treatment +LIQUID_UNIT = "mL" +ULTRAFILTRATION_PAUSED_TEXT = "Ultrafiltration Paused" +RESUME_TEXT = "RESUME ULTRAFILTRATION" +EDIT_TEXT = "EDIT ULTRAFILTRATION VOLUME" +TITLE_TEXT = "ULTRAFILTRATION VOLUME (L)" + +#create custom treatment +TREATMENT_TITLE = "Create a Custom Treatment" +CONFIRM_TREATMENT_TITLE = "Confirm Treatment" +PRESCRIPTION_TITLE = "PRESCRIPTION" +OPERATING_PARAMETERS_TITLE = "OPERATING PARAMETERS" +PATIENT_ID_TEXT = "Patient ID" +BLOOD_FLOW_RATE = "Blood Flow Rate" +DIALYSATE_FLOW_RATE = "Dialysate Flow Rate" +DURATION = "Duration" +SALINE_BOLUS_VOLUME = "Saline Bolus Volume" + +#main treatment screen +VITALS_TITLE = "VITALS" +HEART_RATE_TITLE = "Heart Rate" +BLOOD_PRESSURE_TITLE = "Blood Pressure" +BLOOD_PRESSURE_UNIT = "mmHg" +HEART_RATE_UNIT = "BPM" + +#create custom treatment +TREATMENT_TITLE = "Create a Custom Treatment" +CONFIRM_TREATMENT_TITLE = "Confirm Treatment" +PRESCRIPTION_TITLE = "PRESCRIPTION" +OPERATING_PARAMETERS_TITLE = "OPERATING PARAMETERS" +PATIENT_ID_TEXT = "Patient ID" +PATIENT_ID = "demopatientid" +BLOOD_FLOW_RATE = "Blood Flow Rate" +DIALYSATE_FLOW_RATE = "Dialysate Flow Rate" +DURATION = "Duration" +HEPARIN_DISPENSING_RATE = "Heparin Dispensing Rate" +HEPARIN_BOLUS_VOLUME = "Heparin Bolus Volume" +HEPARIN_STOP_TIME = "Heparin Stop Time" +SALINE_BOLUS_VOLUME = "Saline Bolus Volume" +HEPARIN_TYPE_TITLE = "Heparin Type" +SALINE_BOLUS_TITLE = "Saline Bolus" +ACID_CONCENTRATE_TITLE = "Acid Concentrate" +BICARBONATE_CONCENTRATE_TITLE = "Bicarbonate Concentrate" +DIALYZER_TYPE_TITLE = "Dialyzer Type" +DIALYSATE_TEMPERATURE = "Dialysate Temperature" +BLOOD_PRESSURE_MEASUREMENT_INTERVAL = "Blood Pressure Measurement Interval" +RINSEBACK_FLOW_RATE = "Rinseback Flow Rate" +OFF_TEXT = "OFF" +CONTINUE_TEXT = "CONTINUE" +CREATE_TREATMENT_PARAMETERS = ["Blood Flow Rate", "Dialysate Flow Rate", "Duration","Heparin Dispensing Rate", + "Heparin Bolus Volume","Heparin Stop Time", "Saline Bolus", "Dialysate Temperature", + "Blood Pressure Measurement Interval", "Rinseback Flow Rate"] + +OFF_TEXT = "OFF" +BACK_TEXT = "BACK" +CONTINUE_TEXT = "CONTINUE" + +PRESCRIPTION_DETAILS = { + "Blood Flow Rate": "mL/min", "Dialysate Flow Rate": "mL/min", + "Duration": "min", "Heparin Dispensing Rate": "mL/hr", + "Heparin Bolus Volume": "mL", "Heparin Stop Time": "min", + "Saline Bolus Volume": "mL", + "Dialysate Temperature": "°C", "Arterial Pressure Limit Low": "mmHg", + "Arterial Pressure Limit High": "mmHg","Blood Pressure Measure Interval":"min", + "Rinseback Rate" : "mL/min", "Venous Pressure Limit High": "mmHg", + "Venous Pressure Limit Low": "mmHg" +} + +#Time_Duration +TREATMENT_PAUSED_TEXT = "Treatment Paused" + +#pre-treatment +CONSUMABLE_SELF_TEST_TEXT = "Consumables Self Test" +BICARB_PUMP_CHECK_TEXT = "BiCarb Pump Check" +ACID_PUMP_CHECK_TEXT = "Acid Pump Check" +SELF_TEST_COMPLETE_TEXT = "Self Test Complete!" +BUSY = "Busy" +CHECK = "Check" +BEGIN_PRIME_TITLE = "Begin Prime" +PRIMING_TITLE = "Priming" +SYSTEM_SELF_TEST_TITLE = "System Self Test" +FILTER_FLUSH_TITLE = "Filter Flush" +SALINE_UNIT = "mL" +BLOOD_PRIMING_DEFAULT_VALUE = "0 mL" BLOOD_PRIMING_TEXT = "Blood Priming" + +#Pre-Treatment Disposables +NEXT_BUTTON_TEXT = "NEXT" +BACK_BUTTON_TEXT = "BACK" +CONFIRM_BUTTON_TEXT = "CONFIRM" + +#Filter Flush +BEGIN_PRIME_TITLE = "Begin Prime" +PRIMING_TITLE = "Priming" +FILTER_FLUSH_TITLE = "Filter Flush" +SYSTEM_SELF_TEST_TITLE = "System Self Test" + + +#Pre_treatment_water_sample +SAMPLE_TEXT = "Sample" +CREATE_TEXT = "Create" +WATER_SAMPLE_BUTTON_TEXT = "WATER SAMPLE" +NEXT_BUTTON_TEXT = "NEXT" +WATER_SAMPLE_BUTTON_TEXT = "WATER SAMPLE" +BACK_BUTTON_TEXT = "BACK" +PASS_TEXT = "PASS" +FAIL_TEXT = "FAIL" +OK_TEXT = "OK" + +#Vitals +SYSTOLIC_TEXT = "systolic" +DIASTOLIC_TEXT = "diastolic" + +#priming +TEST_DRY_STEPS = ["Used Cartridge Check", "Occlusion Sensors Check", "Pressure Sensors Check", "Syringe Pump Check"] +PRIMING_STEPS = ["Blood Circuit Priming", "Dialysate Circuit Priming", "Wet Self Tests"] +SELF_TEST_COMPLETION_MSG = "Self Test Complete!" +PRIMING_COMPLETE_MSG = "Priming Complete!" + +#main treatment pressure +PRESSURE_TITLE = "PRESSURES" +ARTERIAL_TITLE = "Arterial" +VENOUS_TITLE = "Venous" +VENOUS_UOM = "mmHg" +ARTERIAL_UOM = "mmHg" +LOW_TEXT = "LOW" +HIGH_TEXT = "HIGH" + +#main_treatment_flows +FLOW_UNIT = "mL/min" +BLOOD_FLOW_TEXT = "blood" +DIALYSATE_FLOW_TEXT = "dialysate" + +#main treatment screen +VITALS_TITLE = "VITALS" +IN_RANGE_COLOR = "#fcfcfc" + +PRESCRIPTION_DETAILS = { + "Blood Flow Rate": "mL/min", "Dialysate Flow Rate": "mL/min", + "Duration": "min", "Heparin Dispensing Rate": "mL/hr", + "Heparin Bolus Volume": "mL", "Heparin Stop Time": "min", + "Saline Bolus Volume": "mL", + "Dialysate Temperature": "°C", "Arterial Pressure Limit Low": "mmHg", + "Arterial Pressure Limit High": "mmHg","Blood Pressure Measure Interval":"min", + "Rinseback Rate" : "mL/min", "Venous Pressure Limit High": "mmHg", + "Venous Pressure Limit Low": "mmHg" +} + + +# pretreatment_patient_connection +DIASTOLIC_TEXT = "diastolic" +SYSTOLIC_TEXT = "systolic" +HEART_RATE_TITLE = "Heart Rate" +BLOOD_PRESSURE_TITLE = "Blood Pressure" +BLOOD_PRESSURE_UNIT = "mmHg" +HEART_RATE_UNIT = "BPM" + +#tst_treatment_monitoring +FLOWS_TEXT = "FLOWS" +BLOOD_UNIT = "mL/min" +DIALYSATE_TEXT = "Dialysate" +BLOOD_TEXT = "Blood" +VITALS_TEXT = "VITALS" +BLOOD_PRESSURE_TEXT = "mmHg" +HEARTRATE_UNIT = "BPM" +PRESSURE_TEXT = "PRESSURE (mmHg)" +ARTEREAL_TEXT = "Arterial" +VENOUS_TEXT = "Venous" +TIME_DURATION_TEXT = "Time Remaining" +ULTRAFILTERATION_TEXT = "ULTRAFILTRATION VOLUME (L)" +SALINE_BOLUS = "SALINE BOLUS" +VOLUME_DELIVERED = "Volume Delivered" +CUMULATIVE_DELIVERED = "Cumulative Delivered" +VOLUME_DELIVERED = "Volume Delivered" + +#post-treatment +PATIENT_DISCONNECTION_TEXT = "Patient Disconnection" +REVIEW_TEXT = "Review" +EXPORT_TEXT = "Export" +PATIENT_DISCONNECTION_CONFIRM_BUTTON_TEXT = "CONFIRM" +DISPOSABLE_TEXT = "Disposables" +NEXT_TEXT = "NEXT" +BACK_TEXT = "BACK" +CONFIRM_TEXT = "CONFIRM" +DISPOSABLES_REMOVAL_TEXT = "Disposables Removal" + +#post treatment review +TREATMENT_REVIEW_TITLE_TEXT = "Treatment Review" +POST_TREATMENT_REVIEW_SCREEN_UNITS = { + "Patient ID" : "", + "Heparin Stop" : "min", + "Device ID" : "", + "Heparin Delivered Volume": "mL", + "Blood Flow Rate" : "mL/min", + "Treatment Start DateTime" : "", + "Dialysate Flow Rate" : "mL/min", + "Treatment End DateTime" : "", + "Treatment Duration" : "min", + "Water Sample Test Result": "", + "Actual Treatment Duration":"min", + "Dialysate Volume Used" : "L", + "Acid ConcentrateType" : "", + "Prescribed UF Volume" : "L", + "Bicarbonate Concentrate Type" : "", + "Target UF Volume" : "L", + "Potassium Concentration" : "mEg/L", + "Actual UF Volume" : "L", + "Calcium Concentration" :"mEg/L", + "Prescribed UF Rate" : "mL/min", + "Bicarbonate Concentration" : "mEg/L", + "Target UF Rate": "mL/min", + "Sodium Concentration" : "mEg/L", + "Actual UF Rate": "mL/min", + "Dialysate Temperature" :"°C", + "Saline Bolus Volume" : "mL", + "Dialyzer Type" : "", + "Average Blood Flow" : "mL/min", + "Heparin Type" : "IU/mL", + "Average Dialysate Flow" : "mL/min", + "Heparin Concentration" : "IU/mL", + "Average Dialysate Temp" : "°C", + "Heparin Bolus Volume": "mL", + "Average Arterial Pressure" : "mmHg", + "Heparin Dispense Rate" : "mL/hr", + "Average Venous Pressure" : "mmHg", + } + +#Information +INFORMATION_TITLES = ["Information", "Versions"] +INFORMATION_PARAMETERS = ["Information", "UI Version", "HD Version", "HD FPGA Version", "HD Serial Number", "DG Version", "DG FPGA Version", "DG Serial Number"] +SERIVCES_TITLE = "Services" +SERVICES_PARAMETERS = ["HD Last Service Date", "HD Next Service Date", "DG Last Service Date", "DG Next Service Date"] + +#volume and brightness +VOLUME_AND_BRIGHTNESS_TEXT = "Volume And Brightness" +BRIGHTNESS_TEXT = "Brightness" +ALARM_VOLUME_TEXT = "Alarm Volume" +UNIT_OF_VOLUME_AND_BRIGHTNESS = "%" + +#services +SHUTDOWN_TEXT = "SHUTDOWN" + +# pretreatment_patient_connection +ACK_REQ_STATUS = 'Ack Req' +ACK_BAK_STATUS = 'Ack Bak' +PATIENT_CONNECTION_TEXT = "Patient Connection" +UF_VOLUME_TEXT = "Ultrafiltration Volume (L)" +UF_TITLE_TEXT = "Ultrafiltration Setup" +BP_HR_TEXT = "BP/HR" +SKIP_TEXT = "SKIP" +TUTORIAL_TEXT = { + 0 : "Wash your hands and establish vascular access per your clinic's instructions.", + 1 : "Pinch arterial clamp and venous clamp on located on the cartridge patient lines.", + 2 : "Remove arterial and venous shunt.", + 3 : "Connect arterial and venous cartridge lines to your patient access lines." +} + +ACCEPTED = True +REJECTED = False + +#pretreatment_screen_bullets +PRE_TREATMENT_SCREENS = ["Create" , "Sample" , "Consumables" , "Disposables" , "Prime" , "Ultrafiltration" , "BP/HR" , "Connection" , "Start"] + +#ui_logs +ACK_REQ_STATUS = 'Ack Req' +ACK_BAK_STATUS = 'Ack Bak' +BLOOD_PRIMING_TEXT = "Blood Priming" SALINE_UNIT = "mL" BLOOD_PRIMING_DEFAULT_VALUE = "0 mL"