Index: shared/scripts/configuration/strings.py =================================================================== diff -u -ra309546f47434a0a2a22de97e24947d252b59106 -rd5d976dfec8c5324cd779fb192b1a3e36032547d --- shared/scripts/configuration/strings.py (.../strings.py) (revision a309546f47434a0a2a22de97e24947d252b59106) +++ shared/scripts/configuration/strings.py (.../strings.py) (revision d5d976dfec8c5324cd779fb192b1a3e36032547d) @@ -8,7 +8,7 @@ # # @file strings.py # -# @author (last) LTTS +# @author (last) LTTS # @date (last) 18-Jan-2022 # ############################################################################ @@ -20,27 +20,6 @@ BLOOD_PRIMING_DEFAULT_VALUE = "0 mL" -# pretreatment_patient_connection -DIASTOLIC_TEXT = "diastolic" -SYSTOLIC_TEXT = "systolic" -OUT_OF_RANGE_COLOR = "#c53b33" -IN_RANGE_COLOR = "#fcfcfc" -HEART_RATE_TITLE = "Heart Rate" -BLOOD_PRESSURE_TITLE = "Blood Pressure" -BLOOD_PRESSURE_UNIT = "mmHg" -HEART_RATE_UNIT = "BPM" -PATIENT_CONNECTION_TEXT = "Patient Connection" -UF_VOLUME_TEXT = "Ultrafiltration Volume (L)" -UF_TITLE_TEXT = "Ultrafiltration Setup" -BP_HR_TEXT = "BP/HR" -SKIP_TEXT = "SKIP" -TUTORIAL_TEXT = { - 0 : "Wash your hands and establish vascular access per your clinic's instructions.", - 1 : "Pinch arterial clamp and venous clamp on located on the cartridge patient lines.", - 2 : "Remove arterial and venous shunt.", - 3 : "Connect arterial and venous cartridge lines to your patient access lines." -} - PRE_TREATMENT_SCREENS = { 1 : "Create" , 2 : "Sample" , @@ -53,55 +32,106 @@ 9 : "Start" } - # dictionary of rejection reason from application source code. # message location -> denali-> Headers-> common-> MsgDefs.h REJECTION_REASON = { - 0: "No Active Alarm List", - 1: "REQUEST_REJECT_REASON_NOT_ALLOWED_IN_CURRENT_MODE", # Request is not allowed in the current operating mode - 2: "REQUEST_REJECT_REASON_TIMEOUT_WAITING_FOR_USER_CONFIRM", # Validated request was not confirmed by user in reasonable time - 3: "REQUEST_REJECT_REASON_NOT_IN_TREATMENT_MODE", # Request is not allowed if not in treatment mode - 4: "REQUEST_REJECT_REASON_INVALID_TREATMENT_STATE", # Request is not allowed in current treatment state - 5: "REQUEST_REJECT_REASON_TREATMENT_TOO_CLOSE_TO_FINISHED", # Request is not allowed so near end of treatment - 6: "REQUEST_REJECT_REASON_TREATMENT_TIME_OUT_OF_RANGE", # Treatment duration is out of range - 7: "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_CURRENT", # Treatment time change is less than currently elapsed treatment time - 8: "REQUEST_REJECT_REASON_BLOOD_FLOW_OUT_OF_RANGE", # Blood flow is out of range - 9: "REQUEST_REJECT_REASON_DIAL_FLOW_OUT_OF_RANGE", # Dialysate flow is out of range - 10: "REQUEST_REJECT_REASON_DIAL_VOLUME_OUT_OF_RANGE", # Dialysate flow rate or treatment duration causes dialysate volume to exceed limit - 11: "REQUEST_REJECT_REASON_UF_VOLUME_OUT_OF_RANGE", # Ultrafiltration volume is out of range - 12: "REQUEST_REJECT_REASON_UF_RATE_OUT_OF_RANGE", # Ultrafiltration rate is out of range - 13: "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_MINIMUM", # Treatment time change is less than minimum treatment time - 14: "REQUEST_REJECT_REASON_UF_NOT_IN_PROGESS", # Ultrafiltration is not currently in progress - 15: "REQUEST_REJECT_REASON_UF_NOT_PAUSED", # Ultrafiltration is not currently paused - 16: "REQUEST_REJECT_REASON_SALINE_BOLUS_IN_PROGRESS", # A saline bolus is in progress - 17: "REQUEST_REJECT_REASON_PARAM_OUT_OF_RANGE", # A treatment parameter is out of range - 18: "REQUEST_REJECT_REASON_HEPARIN_PRESTOP_EXCEEDS_DURATION", # The Heparin pre-stop setting is greater than the treatment duration - 19: "REQUEST_REJECT_REASON_ARTERIAL_PRESSURE_LOW_VS_HIGH", # Arterial pressure low and high alarm limits are not inconsistent - 20: "REQUEST_REJECT_REASON_VENOUS_PRESSURE_LOW_VS_HIGH", # Venous pressure low and high alarm limits are inconsistent - 21: "REQUEST_REJECT_REASON_SALINE_MAX_VOLUME_REACHED", # Saline bolus volume maximum has been reached - no more saline allowed - 22: "REQUEST_REJECT_REASON_SALINE_BOLUS_NOT_IN_PROGRESS", # A saline bolus is not in progress - 23: "REQUEST_REJECT_REASON_ACTION_DISABLED_IN_CURRENT_STATE", # Requested user action is disabled in current state - 24: "REQUEST_REJECT_REASON_ALARM_IS_ACTIVE", # Requested user action not allowed while alarm is active - 25: "REQUEST_REJECT_REASON_INVALID_COMMAND", # Requested user action invalid - 26: "REQUEST_REJECT_REASON_TREATMENT_IS_COMPLETED", # The treatment has been completed - 27: "REQUEST_REJECT_REASON_ADDL_RINSEBACK_MAX_VOLUME_REACHED", # Rinseback additional volume maximum has been reached - no more additional rinsebacks allowed - 28: "REQUEST_REJECT_REASON_UF_VOLUME_NOT_SET", # Ultrafiltration volume is not set yet - 29: "REQUEST_REJECT_REASON_NO_PATIENT_CONNECTION_CONFIRM", # The user has not confirmed patient connection - 30: "REQUEST_REJECT_REASON_HEPARIN_PAUSE_INVALID_IN_THIS_STATE", # Heparin cannot be paused if not currently deliverying Heparin - 31: "REQUEST_REJECT_REASON_HEPARIN_NOT_PAUSED", # Heparin cannot be resumed if not paused - 32: "REQUEST_REJECT_REASON_DG_COMM_LOST", # Treatment cannot initiate if DG comm is lost - 33: "REQUEST_REJECT_REASON_DRAIN_NOT_COMPLETE", # Post-treatment reservoirs drain not complete - 34: "REQUEST_REJECT_REASON_DG_NOT_IN_STANDBY_IDLE_STATE", # Treatment cannot initiate if DG is not in standby idle state - 35: "REQUEST_REJECT_REASON_INVALID_REQUEST_FORMAT", # Request message not formatted properly - 36: "REQUEST_REJECT_REASON_INVALID_DATE_OR_TIME", # Given date/time is invalid - 37: "REQUEST_REJECT_REASON____AVAILABLE_1", # Not used - available for use - 38: "REQUEST_REJECT_REASON_BATTERY_IS_NOT_CHARGED", # Battery does not have enough charge to start treatment - 39: "REQUEST_REJECT_REASON_RINSEBACK_NOT_COMPLETED", # Cannot move on to recirculate without completing full rinseback. - 40: "REQUEST_REJECT_REASON_RESERVOIR_ONE_IS_NOT_READY", # Reservoir one fill is not complete - 41: "REQUEST_REJECT_REASON_PUMP_TRACK_NOT_CLOSED", # Pump track is not ready / closed - 42: "REQUEST_REJECT_REASON_DOOR_NOT_CLOSED", # Door is not closed - 43: "REQUEST_REJECT_REASON_SYRINGE_NOT_PRESENT", # Syringe is not present - } + 0 : "REQUEST_REJECT_REASON_NONE" , # Used when there is no rejection + 1 : "REQUEST_REJECT_REASON_NOT_ALLOWED_IN_CURRENT_MODE" , # "REQuest is not allowed in the current operating mode + 2 : "REQUEST_REJECT_REASON_TIMEOUT_WAITING_FOR_USER_CONFIRM" , # Validated "REQuest was not confirmed by user in reasonable time + 3 : "REQUEST_REJECT_REASON_NOT_IN_TREATMENT_MODE" , # "REQuest is not allowed if not in treatment mode + 4 : "REQUEST_REJECT_REASON_INVALID_TREATMENT_STATE" , # "REQuest is not allowed in current treatment state + 5 : "REQUEST_REJECT_REASON_TREATMENT_TOO_CLOSE_TO_FINISHED" , # "REQuest is not allowed so near end of treatment + 6 : "REQUEST_REJECT_REASON_TREATMENT_TIME_OUT_OF_RANGE" , # Treatment duration is out of range + 7 : "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_CURRENT" , # Treatment time change is less than currently elapsed treatment time + 8 : "REQUEST_REJECT_REASON_BLOOD_FLOW_OUT_OF_RANGE" , # Blood flow is out of range + 9 : "REQUEST_REJECT_REASON_DIAL_FLOW_OUT_OF_RANGE" , # Dialysate flow is out of range + 10 : "REQUEST_REJECT_REASON_DIAL_VOLUME_OUT_OF_RANGE" , # Dialysate flow rate or treatment duration causes dialysate volume to exceed limit + 11 : "REQUEST_REJECT_REASON_UF_VOLUME_OUT_OF_RANGE" , # Ultrafiltration volume is out of range + 12 : "REQUEST_REJECT_REASON_UF_RATE_OUT_OF_RANGE" , # Ultrafiltration rate is out of range + 13 : "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_MINIMUM" , # Treatment time change is less than minimum treatment time + 14 : "REQUEST_REJECT_REASON_UF_NOT_IN_PROGESS" , # Ultrafiltration is not currently in progress + 15 : "REQUEST_REJECT_REASON_UF_NOT_PAUSED" , # Ultrafiltration is not currently paused + 16 : "REQUEST_REJECT_REASON_SALINE_BOLUS_IN_PROGRESS" , # A saline bolus is in progress + 17 : "REQUEST_REJECT_REASON_PARAM_OUT_OF_RANGE" , # A treatment parameter is out of range + 18 : "REQUEST_REJECT_REASON_HEPARIN_PRESTOP_EXCEEDS_DURATION" , # The Heparin pre-stop setting is greater than the treatment duration + 19 : "REQUEST_REJECT_REASON_ARTERIAL_PRESSURE_LOW_VS_HIGH" , # Arterial pressure low and high alarm limits are not inconsistent + 20 : "REQUEST_REJECT_REASON_VENOUS_PRESSURE_LOW_VS_HIGH" , # Venous pressure low and high alarm limits are inconsistent + 21 : "REQUEST_REJECT_REASON_SALINE_MAX_VOLUME_REACHED" , # Saline bolus volume maximum has been reached - no more saline allowed + 22 : "REQUEST_REJECT_REASON_SALINE_BOLUS_NOT_IN_PROGRESS" , # A saline bolus is not in progress + 23 : "REQUEST_REJECT_REASON_ACTION_DISABLED_IN_CURRENT_STATE" , # "REQuested user action is disabled in current state + 24 : "REQUEST_REJECT_REASON_ALARM_IS_ACTIVE" , # "REQuested user action not allowed while alarm is active + 25 : "REQUEST_REJECT_REASON_INVALID_COMMAND" , # "REQuested user action invalid + 26 : "REQUEST_REJECT_REASON_TREATMENT_IS_COMPLETED" , # The treatment has been completed + 27 : "REQUEST_REJECT_REASON_ADDL_RINSEBACK_MAX_VOLUME_REACHED" , # Rinseback additional volume maximum has been reached - no more additional rinsebacks allowed + 28 : "REQUEST_REJECT_REASON_UF_VOLUME_NOT_SET" , # Ultrafiltration volume is not set yet + 29 : "REQUEST_REJECT_REASON_NO_PATIENT_CONNECTION_CONFIRM" , # The user has not confirmed patient connection + 30 : "REQUEST_REJECT_REASON_HEPARIN_PAUSE_INVALID_IN_THIS_STATE" , # Heparin cannot be paused if not currently deliverying Heparin + 31 : "REQUEST_REJECT_REASON_HEPARIN_NOT_PAUSED" , # Heparin cannot be resumed if not paused + 32 : "REQUEST_REJECT_REASON_DG_COMM_LOST" , # Treatment cannot initiate if DG comm is lost + 33 : "REQUEST_REJECT_REASON_DRAIN_NOT_COMPLETE" , # Post-treatment reservoirs drain not complete + 34 : "REQUEST_REJECT_REASON_DG_NOT_IN_STANDBY_IDLE_STATE" , # Treatment cannot initiate if DG is not in standby idle state + 35 : "REQUEST_REJECT_REASON_INVALID_REQUEST_FORMAT" , # "REQuest message not formatted properly + 36 : "REQUEST_REJECT_REASON_INVALID_DATE_OR_TIME" , # Given date/time is invalid + 37 : "REQUEST_REJECT_REASON_NO_NEW_TREATMENT_ALARM_TRIGGERED" , # Treatment cannot initiate if an alarm with no new treatment property has triggered before + 38 : "REQUEST_REJECT_REASON_BATTERY_IS_NOT_CHARGED" , # Battery does not have enough charge to start treatment + 39 : "REQUEST_REJECT_REASON_RINSEBACK_NOT_COMPLETED" , # Cannot move on to recirculate without completing full rinseback +} +#create custom treatment +PATIENT_ID = "demopatientid" +TREATMENT_TITLE = "Create a Custom Treatment" +HEPARIN_TYPE = "UFH 1,000 IU/mL" +ACID_CONCENTRATE = ["Fres. Naturalyte", "08-1251-1", "08-2251-0", "08-3251-9"] +BICARBONATE_CONCENTRATE = "Fres. Centrisol" +DIALYZER_TYPE = ["BB Diacap Pro 13H", "BB Diacap Pro 16H", "BB Diacap Pro 19H", "F Optiflux F160NRe", "F Optiflux F180NRe"] +CONFIRM_TREATMENT_TITLE = "Confirm Treatment" +PRESCRIPTION_TITLE = "PRESCRIPTION" +OPERATING_PARAMETERS_TITLE = "OPERATING PARAMETERS" +COLOR_CODES = {"Aqua": "#81ffff", "Blue": "#017dea", "Blue 2": "#1090d5", "Green": "#29fd2d", "Grey": "#d3d3d3", + "Lavender": "#db98f5", "Light Blue": "#acd7f1", "Light Teal": "#29f1da","Lime": "#b7fc36", + "Magenta":"#fd28fd", "Orange": "#f2721c", "Peach":"#f1979a", "Red": "#c53b33", "Rose":"#fc178d", + "Slate blue":"#7f7ffa", "Violet": "#6435c9", "White": "#ffffff", "Yellow": "#fcfc4d"} +CURRENT_COLOR = '#000000' +COMPLETE_COLOR= '#4290ec' +ENABLED_COLOR = '#fcfcfc' +INCOMPLETE_COLOR = '#607a91' +BLOOD_FLOW_RATE = "Blood Flow Rate" +DIALYSATE_FLOW_RATE = "Dialysate Flow Rate" +DURATION = "Duration" +HEPARIN_DISPENSING_RATE = "Heparin Dispensing Rate" +HEPARIN_BOLUS_VOLUME = "Heparin Bolus Volume" +HEPARIN_STOP_TIME = "Heparin Stop Time" +SALINE_BOLUS = "Saline Bolus Volume" +HEPARIN_TYPE_TITLE = "Heparin Type" +SALINE_BOLUS_TITLE = "Saline Bolus" +ACID_CONCENTRATE_TITLE = "Acid Concentrate" +BICARBONATE_CONCENTRATE_TITLE = "Bicarbonate Concentrate" +DIALYZER_TYPE_TITLE = "Dialyzer Type" +DIALYSATE_TEMPERATURE = "Dialysate Temperature" +BLOOD_PRESSURE_MEASUREMENT_INTERVAL = "Blood Pressure Measurement Interval" +RINSEBACK_FLOW_RATE = "Rinseback Flow Rate" +CREATE_TREATMENT_PARAMETERS = ["Blood Flow Rate", "Dialysate Flow Rate", "Duration","Heparin Dispensing Rate", + "Heparin Bolus Volume","Heparin Stop Time", "Saline Bolus", "Dialysate Temperature", + "Blood Pressure Measurement Interval", "Rinseback Flow Rate"] +TREATMENT_UNHIGHLIGHTED_COLOR = "#000000" +TREATMENT_HIGHLIGHTED_COLOR = "#135088" +OFF_TEXT = "OFF" +BACK_TEXT = "BACK" +CONTINUE_TEXT = "CONTINUE" + +PRESCRIPTION_DETAILS = { + "Blood Flow Rate": "mL/min", "Dialysate Flow Rate": "mL/min", + "Duration": "min", "Heparin Dispensing Rate": "mL/hr", + "Heparin Bolus Volume": "mL", "Heparin Stop Time": "min", + "Saline Bolus Volume": "mL", + "Dialysate Temperature": "°C", "Arterial Pressure Limit Low": "mmHg", + "Arterial Pressure Limit High": "mmHg","Blood Pressure Measure Interval":"min", + "Rinseback Rate" : "min", "Venous Pressure Limit High": "mmHg", + "Venous Pressure Limit Low": "mmHg" +} + +OPERATIONAL_PARAMETERS = {"Heparin Type": HEPARIN_TYPE, "Acid Concentrate": "Fres. Naturalyte", + "Bicarbonate Concentrate": BICARBONATE_CONCENTRATE, "Dialyzer Type": "BB Diacap Pro 16H"} +