Index: shared/scripts/configuration/strings.py =================================================================== diff -u -ra5a341f1226fbcc861df406c18c240fbe73b7de5 -r71574ed67e513579e7f0ba2916a6b922a9887e56 --- shared/scripts/configuration/strings.py (.../strings.py) (revision a5a341f1226fbcc861df406c18c240fbe73b7de5) +++ shared/scripts/configuration/strings.py (.../strings.py) (revision 71574ed67e513579e7f0ba2916a6b922a9887e56) @@ -1,20 +1,372 @@ - +# -*- coding: utf-8 -*- ########################################################################### # # Copyright (c) 2019-2021 Diality Inc. - All Rights Reserved. # # THIS CODE MAY NOT BE COPIED OR REPRODUCED IN ANY FORM, IN PART OR IN # WHOLE, WITHOUT THE EXPLICIT PERMISSION OF THE COPYRIGHT OWNER. # -# @file strings.py +# @file utils.py # -# @author (last) LTTS +# @author (last) Joseph varghese # @date (last) 18-Jan-2022 # ############################################################################ -#ui_logs -ACK_REQ_STATUS = 'Ack Req' -ACK_BAK_STATUS = 'Ack Bak' +ALARM_ID_AND_MESSAGES = { + 1: "Stuck button POST failure.\nStop or Off button detected to be pressed for at least 1 second during test shortly after power up.", + 2: "HD FPGA POST failure.", + 3: "DG FPGA POST failure.", + 4: "HD Watchdog POST failure.", + 5: "DG Watchdog POST failure.", + 6: "UI communication POST failure.\nUI failed to communicate within a reasonable time after power up.", + 7: "Real-time clock configuration error.", + 8: "HD accelerometer failed POST.", + 9: "DG accelerometer failed POST." , + 10: "RTC or MCU timer inaccurate.", + 11: "DG heaters failed POST.", + 12: "HD firmware image integrity POST test failed.", + 13: "DG firmware image integrity POST test failed.", + 14: "HD blood flow invalid calibration.", + 15: "HD dialysate flow invalid calibration.", + 16: "HD alarm audio failed POST.", + 17: "HD UI POST failed.", + 18: "DG load cells invalid calibration record.", + 19: "DG flow sensors invalid calibration record.", + 20: "DG conductivity sensors invalid calibration record.", + 21: "DG drain line volume invalid calibration record.", + 22: "DG reservoirs invalid calibration record.", + 23: "DG acid concentrate calibration record.", + 24: "DG bicarb concentrate calibration record.", + 25: "DG accelerometer invalid calibration record.", + 26: "HD accelerometer invalid calibration record.", + 27: "HD blood flow invalid calibration record.", + 28: "HD dialyzer flow invalid calibration record.", + 29: "HD heparin force sensor invalid calibration record.", + 30: "HD Software fault.\nSoftware found itself in an unexpected state.", + 31: "Blood pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running.", + 32: "Blood pump failed motor off check.\nMeasured speed while commanded off.", + 33: "Blood pump failed motor direction check.\nMeasured vs commanded.", + 34: "Blood pump failed rotor speed check.\nMismatch with rotor and motor speeds.", + 35: "Dialysis inlet pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running.", + 36: "Dialysis inlet pump failed motor off check.\nMeasured speed while commanded off.", + 37: "Dialysis inlet pump failed motor direction check.\nMeasured vs commanded.", + 38: "Dialysis inlet pump failed rotor speed check.\nMismatch with rotor and motor speeds.", + 39: "Dialysis outlet pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running.", + 40: "Dialysis outlet pump failed motor off check.\nMeasured speed while commanded off.", + 41: "Dialysis outlet pump failed motor direction check.\nMeasured vs commanded.", + 42: "Dialysis outlet pump failed rotor speed check.\nMismatch with rotor and motor speeds.", + 43: "Watchdog expired error.\nWatchdog was not \"pet\" within the appropriate time.", + 44: "User interface communication timeout.", + 45: "Too many bad CRCs detected on received system messages.", + 46: "System message that required acknowledgment was not acknowledged.", + 47: "Ultrafiltration rate is too high error during treatment.", + 48: "Ultrafiltration volume accuracy error during treatment.", + 49: "HD FPGA communication down for too long.", + 50: "FPGA not accepting commanded valve states.", + 51: "Blood pump failed motor speed check.\nMeasured vs commanded.", + 52: "Dialysate inlet pump failed motor speed check.\nMeasured vs commanded.", + 53: "Dialysate outlet pump failed motor speed check.\nMeasured vs commanded.", + 54: "HD critical data integrity check failed.", + 55: "DG critical data integrity check failed.", + 56: "HD accelerometer error (no readings or FPGA reports error).", + 57: "DG accelerometer error (no readings or FPGA reports error).", + 58: "HD valve homing failed.", + 59: "HD valve transition time out.", + 60: "HD valve not functional.", + 61: "HD valve current out of range.", + 62: "HD valve position out of target.", + 63: "FPGA reports failure reading arterial pressure sensor.", + 64: "FPGA reports failure reading venous pressure sensor.", + 65: "HD requests DG command with invalid parameter fault.", + 66: "HD blood leak sensor set point set failure.", + 67: "HD blood pump occlusion self-test failure alarm.", + 68: "HD active reservoir recirculation out of range.", + 69: "HD blood leak sensor invalid calibration record.", + 70: "HD arterial pressure self-test failure alarm." , + 71: "HD venous pressure self-test failure alarm.", + 72: "HD blood flow meter status check self-test failure alarm.", + 73: "HD dialysate flow meter status check self-test failure alarm.", + 74: "HD blood leak detector self-test failure alarm.", + 75: "HD syringe pump self-test failure alarm.", + 76: "HD monitored voltage is out of range.", + 77: "DG monitored voltage is out of range.", + 78: "HD syringe pump direction (from encoder) error.", + 79: "HD syringe pump direction (from controller) error.", + 80: "HD syringe pump fault reported by FPGA.", + 81: "HD syringe pump over travel error.", + 82: "HD syringe pump DAC write failure.", + 83: "HD syringe pump is running while the BP is off.", + 84: "HD venous pressure sensor not being read.", + 85: "HD pump track latch opened alarm.", + 86: "HD BP occlusion sensor not being read.", + 87: "DG heating invalid calibration record.", + 88: "DG concentrate pumps hall sensor out of range.", + 89: "HD BP occlusion sensor error.", + 90: "This alarm ID is available for use.", + 91: "HD No dialysate flow data receive in the last 3 seconds.", + 92: "DG conductivity sensor bad status.", + 93: "This alarm ID is available for use.", + 94: "This alarm ID is available for use.", + 95: "This alarm ID is available for use.", + 96: "Inlet water temperature in high range.", + 97: "Fill conductivity out of range.", + 98: "HD battery communication fault.", + 99: "HD syringe pump stall alarm.", + 100: "HD no cartridge self-test timeout.", + 101: "HD dry self-test timeout.", + 102: "Real-time clock communication error.", + 103: "HD non-volatile calibration group invalid record CRC.", + 104: "Air trap level sensors reporting illegal combination of air/fluid.", + 105: "DG non-volatile system group invalid record CRC.", + 106: "DG inlet water conductivity is greater than threshold.", + 107: "HD reports DG restarted fault.", + 108: "HD syringe pump ADC error.", + 109: "HD syringe pump volume check error.", + 110: "HD syringe pump speed check error.", + 111: "HD syringe pump not stopped in off state error.", + 112: "HD blood leak detector fault.", + 113: "HD arterial air bubble detector self-test failure.", + 114: "HD venous air bubble detector self-test failure.", + 115: "DG temperature sensor out of range.", + 116: "DG temperature sensor ADC out of range.", + 117: "DG primary heater internal temperature out of range.", + 118: "DG primary heater cold junction temperature out of range.", + 119: "DG trimmer heater internal temperature out of range.", + 120: "DG trimmer heater cold junction temperature out of range.", + 121: "DG main primary heater voltage out of range.", + 122: "DG small primary heater voltage out of range.", + 123: "DG trimmer heater voltage out of range.", + 124: "HD end of treatment alarm (high priority).", + 125: "Blood sitting too long after treatment stopped by user alarm (>5 min).", + 126: "HD blood leak detected alarm.", + 127: "Venous pressure too low during treatment." , + 128: "HD venous air bubble detected alarm.", + 129: "HD venous air bubble detected rinseback alarm.", + 130: "Venous pressure too high during treatment.", + 131: "Arterial pressure too low during treatment.", + 132: "Arterial pressure too high during treatment.", + 133: "DG fluid leak detected alarm.", + 134: "HD fluid leak detected alarm." , + 135: "HD experienced large acceleration.", + 136: "DG experienced large acceleration.", + 137: "HD tilt exceeds maximum.", + 138: "DG tilt exceeds maximum.", + 139: "HD AC power lost alarm.", + 140: "Dialysate generator communication timeout.", + 141: "Air trap fill timeout during treatment.", + 142: "Blood pump occlusion detected.", + 143: "DG dialysate temperature sensors drift timeout.", + 144: "DG software configuration record invalid CRC.", + 145: "Concentrate conductivity after adding acid out of range alarm.", + 146: "Dialysate conductivity out of range.", + 147: "Wait for the DG to produce dialysate.", + 148: "Inlet water temperature too high.", + 149: "Alarm ID available for use.", + 150: "Inlet water conductivity in high range.", + 151: "Inlet water conductivity in low range.", + 152: "Inlet water pressure in low range.", + 153: "HD prime completed high priority alarm.", + 154: "EEPROM operations (read, write, erase) failure.", + 155: "DG software configuration record invalid CRC.", + 156: "HW usage data (treatment time in HD and total consumed water in DG) failure.", + 157: "DG chemical disinfect prime acid line timeout.", + 158: "Inlet water temperature is in the low range.", + 159: "Dialysate inlet pump failed flow vs motor speed check.", + 160: "Blood pump rotor speed too high.", + 161: "This alarm ID is available for use.", + 162: "This alarm ID is available for use.", + 163: "HD sees primary load cell for reservoir 1 change too much too fast.", + 164: "HD sees primary load cell for reservoir 2 change too much too fast.", + 165: "HD in treatment rinseback operation timeout.", + 166: "HD in treatment re-circ sub-mode for too long.", + 167: "HD cartridge door opened alarm.", + 168: "HD active reservoir depletion timeout.", + 169: "Dialysate flow rate out of range.", + 170: "HD syringe empty alarm.", + 171: "HD syringe pump occlusion alarm.", + 172: "HD syringe pump not enough Heparin alarm.", + 173: "HD arterial air bubble detected alarm.", + 174: "HD arterial air bubble detected rinseback alarm.", + 175: "HD pump direction status error.", + 176: "HD active reservoir is full during treatment and DG not ready to switch reservoirs.", + 177: "DG software fault.\nSoftware found itself in an unexpected state.", + 178: "HD communication timeout.", + 179: "DG FPGA communication down for too long.", + 180: "DG load cell ADC error.", + 181: "DG load cells weight out of range for tare.", + 182: "DG load cells invalid calibration.", + 183: "DG invalid load cell value.", + 184: "Inlet or Outlet UV reactor not healthy.", + 185: "DG fan RPM out of range.", + 186: "DG concentrate pump fault.", + 187: "DG concentrate pump CP1 speed control error.", + 188: "DG concentrate pump CP2 speed control error.", + 189: "DG drain pump RPM out of range.", + 190: "DG drain pump off fault.", + 191: "DG flow rate out of upper range.", + 192: "DG flow rate out of lower range.", + 193: "RO pump flow rate out of range.", + 194: "DG RO pump duty cycle out of range.", + 195: "DG RO pump pressure out of range.", + 196: "DG temperature sensor error flag fault.", + 197: "DG temperature sensors ADC fault.", + 198: "DG heaters cold junction temperature out of range.", + 199: "DG heaters fault.", + 200: "DG thermistors/sensors temperature out of range.", + 201: "Inlet water quality is bad (temperature, conductivity, pressure).", + 202: "Inlet water pressure fault.", + 203: "Pressure sensor fault.", + 204: "RO rejection ratio out of range.", + 205: "Conductivity sensor fault.", + 206: "DG dialysate fill runs out of time.", + 207: "DG flow meter check failure alarm.", + 208: "DG primary heater on with no flow time out.", + 209: "DG drain circulation line timeout.", + 210: "HD battery pack detected an error.", + 211: "Blood sitting too long warning (>4 min).", + 212: "HD end of treatment alarm (user not acting to end treatment).", + 213: "HD prime completed medium priority alarm.", + 214: "HD Saline bolus volume check failure.", + 215: "HD rinseback volume check failure.", + 216: "HD end treatment sub-mode timeout alarm.", + 217: "HD blood prime volume check failure.", + 218: "HD syringe detected alarm.", + 219: "HD syringe pump syringe removed alarm.", + 220: "HD battery pack SOC is too low.", + 221: "HD Saline bag is empty.", + 222: "HD dialysate temperature too high alarm.", + 223: "HD dialysate temperature too low alarm.", + 224: "Treatment stopped by user action.", + 225: "HD end of treatment warning.", + 226: "HD prime completed low priority alarm.", + 227: "HD prime out of time alarm.", + 228: "HD time out on prime sub-mode purge air state.", + 229: "HD prime dialysate dialyzer time out alarm.", + 230: "HD prime dialysate bypass time out alarm.", + 231: "HD pre-treatment mode dry self-tests failure.", + 232: "HD pre-treatment mode wet self-tests failure.", + 233: "RTC battery low.", + 234: "RTC (i.e read time) or RAM operations failure (read or write).", + 235: "HD in treatment stopped sub-mode after rinseback completed (no escalation).", + 236: "HD needs new cartridge to be installed.", + 237: "HD prime saline dialyzer time out alarm.", + 238: "HD no cartridge loaded or installed improperly alarm.", + 239: "HD fail to remove cartridge alarm.", + 240: "Bicarb conductivity out of range during bicarb pump check alarm.", + 241: "DG reservoir drain time out.", + 242: "DG reservoir fill time out.", + 243: "DG reservoir leak time out.", + 244: "DG temperature sensors difference out of range.", + 245: "DG heat disinfect target temperature time out (could not reach to temperature).", + 246: "DG heat disinfect inlet pressure and temperature sensors out of range.", + 247: "DG heat disinfect inlet conductivity and temperature out of range.", + 248: "DG chemical disinfect could not reach to target temperature.", + 249: "DG chemical disinfect inlet pressure and temperature sensors out of range.", + 250: "DG chemical disinfect inlet conductivity and temperature out of range.", + 251: "HD invalid system record.", + 252: "HD invalid service record.", + 253: "DG invalid system record.", + 254: "DG invalid service record.", + 255: "HD and UI software builds are not compatible.", + 256: "HD and DG software builds are not compatible.", + 257: "DG FPGA power out timeout.", + 258: "HD FPGA power out timeout.", + 259: "HD temperatures out of range.", + 260: "UI POST Application Integrity (Sha256Sum) failure.", + 261: "UI POST CANBus failure.", + 262: "UI POST Display failure.", + 263: "UI POST Touch failure.", + 264: "UI POST SD-Card failure.", + 265: "UI POST RTC failure.", + 266: "UI POST WiFi failure.", + 267: "UI POST Bluetooth failure.", + 268: "UI POST Ethernet failure.", + 269: "UI POST Sound failure.", + 270: "HD POST Safety Shutdown failure.", + 271: "DG POST Safety Shutdown failure.", + 272: "HD Fan RPM out of range.", + 273: "HD measured blood pump flow rate is out of range.", + 274: "HD measured dialysate inlet pump flow rate is out of range.", + 275: "HD arterial pressure sensor is reading out of range.", + 276: "HD venous pressure sensor is reading out of range.", + 277: "HD BP occlusion sensor is reading out of range.", + 278: "HD active reservoir weight out of range.", + 279: "DG dialysate drain time out.", + 280: "HD arterial pressure sensor read timeout error.", + 281: "Acid concentration bottle low volume alarm.", + 282: "Bicarbonate concentration bottle low volume alarm.", + 283: "DG load cells weight out of range.", + 284: "DG load cells primary/back up drift out of range.", + 285: "HD treatment recirculate timeout warning.", + 286: "HD treatment rinseback complete timeout warning.", + 287: "HD processor clock speed checks against FPGA clock failure.", + 288: "DG trimmer heater on with flow timeout.", + 289: "DG dialysate or concentrate caps not closed." + } - \ No newline at end of file +ALARM_PRIORITIES = {1: "LOW", 2: "MEDIUM", 3: "HIGH"} + +ALARM_LIST_TITLE = "Alarm list" + +REJECTION_REASON = { + 0: "No Active Alarm List", + 1: "REQUEST_REJECT_REASON_NOT_ALLOWED_IN_CURRENT_MODE", # Request is not allowed in the current operating mode + 2: "REQUEST_REJECT_REASON_TIMEOUT_WAITING_FOR_USER_CONFIRM", # Validated request was not confirmed by user in reasonable time + 3: "REQUEST_REJECT_REASON_NOT_IN_TREATMENT_MODE", # Request is not allowed if not in treatment mode + 4: "REQUEST_REJECT_REASON_INVALID_TREATMENT_STATE", # Request is not allowed in current treatment state + 5: "REQUEST_REJECT_REASON_TREATMENT_TOO_CLOSE_TO_FINISHED", # Request is not allowed so near end of treatment + 6: "REQUEST_REJECT_REASON_TREATMENT_TIME_OUT_OF_RANGE", # Treatment duration is out of range + 7: "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_CURRENT", # Treatment time change is less than currently elapsed treatment time + 8: "REQUEST_REJECT_REASON_BLOOD_FLOW_OUT_OF_RANGE", # Blood flow is out of range + 9: "REQUEST_REJECT_REASON_DIAL_FLOW_OUT_OF_RANGE", # Dialysate flow is out of range + 10: "REQUEST_REJECT_REASON_DIAL_VOLUME_OUT_OF_RANGE", # Dialysate flow rate or treatment duration causes dialysate volume to exceed limit + 11: "REQUEST_REJECT_REASON_UF_VOLUME_OUT_OF_RANGE", # Ultrafiltration volume is out of range + 12: "REQUEST_REJECT_REASON_UF_RATE_OUT_OF_RANGE", # Ultrafiltration rate is out of range + 13: "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_MINIMUM", # Treatment time change is less than minimum treatment time + 14: "REQUEST_REJECT_REASON_UF_NOT_IN_PROGESS", # Ultrafiltration is not currently in progress + 15: "REQUEST_REJECT_REASON_UF_NOT_PAUSED", # Ultrafiltration is not currently paused + 16: "REQUEST_REJECT_REASON_SALINE_BOLUS_IN_PROGRESS", # A saline bolus is in progress + 17: "REQUEST_REJECT_REASON_PARAM_OUT_OF_RANGE", # A treatment parameter is out of range + 18: "REQUEST_REJECT_REASON_HEPARIN_PRESTOP_EXCEEDS_DURATION", # The Heparin pre-stop setting is greater than the treatment duration + 19: "REQUEST_REJECT_REASON_ARTERIAL_PRESSURE_LOW_VS_HIGH", # Arterial pressure low and high alarm limits are not inconsistent + 20: "REQUEST_REJECT_REASON_VENOUS_PRESSURE_LOW_VS_HIGH", # Venous pressure low and high alarm limits are inconsistent + 21: "REQUEST_REJECT_REASON_SALINE_MAX_VOLUME_REACHED", # Saline bolus volume maximum has been reached - no more saline allowed + 22: "REQUEST_REJECT_REASON_SALINE_BOLUS_NOT_IN_PROGRESS", # A saline bolus is not in progress + 23: "REQUEST_REJECT_REASON_ACTION_DISABLED_IN_CURRENT_STATE", # Requested user action is disabled in current state + 24: "REQUEST_REJECT_REASON_ALARM_IS_ACTIVE", # Requested user action not allowed while alarm is active + 25: "REQUEST_REJECT_REASON_INVALID_COMMAND", # Requested user action invalid + 26: "REQUEST_REJECT_REASON_TREATMENT_IS_COMPLETED", # The treatment has been completed + 27: "REQUEST_REJECT_REASON_ADDL_RINSEBACK_MAX_VOLUME_REACHED", # Rinseback additional volume maximum has been reached - no more additional rinsebacks allowed + 28: "REQUEST_REJECT_REASON_UF_VOLUME_NOT_SET", # Ultrafiltration volume is not set yet + 29: "REQUEST_REJECT_REASON_NO_PATIENT_CONNECTION_CONFIRM", # The user has not confirmed patient connection + 30: "REQUEST_REJECT_REASON_HEPARIN_PAUSE_INVALID_IN_THIS_STATE", # Heparin cannot be paused if not currently deliverying Heparin + 31: "REQUEST_REJECT_REASON_HEPARIN_NOT_PAUSED", # Heparin cannot be resumed if not paused + 32: "REQUEST_REJECT_REASON_DG_COMM_LOST", # Treatment cannot initiate if DG comm is lost + 33: "REQUEST_REJECT_REASON_DRAIN_NOT_COMPLETE", # Post-treatment reservoirs drain not complete + 34: "REQUEST_REJECT_REASON_DG_NOT_IN_STANDBY_IDLE_STATE", # Treatment cannot initiate if DG is not in standby idle state + 35: "REQUEST_REJECT_REASON_INVALID_REQUEST_FORMAT", # Request message not formatted properly + 36: "REQUEST_REJECT_REASON_INVALID_DATE_OR_TIME", # Given date/time is invalid + 37: "REQUEST_REJECT_REASON____AVAILABLE_1", # Not used - available for use + 38: "REQUEST_REJECT_REASON_BATTERY_IS_NOT_CHARGED", # Battery does not have enough charge to start treatment + 39: "REQUEST_REJECT_REASON_RINSEBACK_NOT_COMPLETED", # Cannot move on to recirculate without completing full rinseback. + 40: "REQUEST_REJECT_REASON_RESERVOIR_ONE_IS_NOT_READY", # Reservoir one fill is not complete + 41: "REQUEST_REJECT_REASON_PUMP_TRACK_NOT_CLOSED", # Pump track is not ready / closed + 42: "REQUEST_REJECT_REASON_DOOR_NOT_CLOSED", # Door is not closed + 43: "REQUEST_REJECT_REASON_SYRINGE_NOT_PRESENT", # Syringe is not present + } + +UNDEFINED_ALARM_ID_MSG = "ALARM_ID_UNDEFINED" +ALARM_TITLE = "Alarm" + +ALARM_PRIORITY_OPTIONS = { + 0 : 'ALARM_PRIORITY_NONE' , + 1 : 'ALARM_PRIORITY_LOW' , + 2 : 'ALARM_PRIORITY_MEDIUM', + 3 : 'ALARM_PRIORITY_HIGH', +} + +BLOOD_PRIMING_TEXT = "Blood Priming" +SALINE_UNIT = "mL" +BLOOD_PRIMING_DEFAULT_VALUE = "0 mL" +