Index: shared/scripts/configuration/strings.py =================================================================== diff -u -rb7f4fef664182ef9b8be312166923cf6d040bd76 -r2961accdbc24fa832a3c6fa3f12fa52ce7938124 --- shared/scripts/configuration/strings.py (.../strings.py) (revision b7f4fef664182ef9b8be312166923cf6d040bd76) +++ shared/scripts/configuration/strings.py (.../strings.py) (revision 2961accdbc24fa832a3c6fa3f12fa52ce7938124) @@ -1,35 +1,66 @@ # -*- coding: utf-8 -*- -BLOOD_PRIMING_TEXT = "Blood Priming" -SALINE_UNIT = "mL" -BLOOD_PRIMING_DEFAULT_VALUE = "0 mL" -RESET_BINARY = "0" -SET_BINARY = "1" #Message binaries appending with for easy identification -ACK_REQ_STATUS = 'Ack Req' -ACK_BAK_STATUS = 'Ack Bak' +#rinseback-setup +RINSE_BACK_SETUP_TEXT = "Rinseback Setup" +RINSEBACK_BUTTON_TEXT = "START RINSEBACK" +END_IMAGE_BUTTON_TEXT = "End" +DECELERATE_BUTTON_TEXT = "Decelerate" +ACCELERATE_BUTTON_TEXT = "Accelerate" +PAUSE_BUTTON_TEXT = "Pause" +RESUME_BUTTON_TEXT = "Resume" +RINSEBACK_TEXT = "Rinseback" +RINSEBACK_COMPLETE_TEXT = "Rinseback Complete" +END_TREATMENT_BUTTON_TEXT = "END TREATMENT" +ADDITIONAL_BUTTON_TEXT = "ADDITIONAL" +ADDITIONAL_RINSEBACK_TEXT = "Additional Rinseback" +RINSEBACK_UNIT = " mL" +RINSEBACK_UNIT_MIN = " mL/min" - -#Setting -CLEAR_ALARM_CONDITION_TEXT = "Clear Alarm Condition" -EXPORT_TEXT ="Export" -DEVICE_SETTINGS_TEXT = "Device Settings" -DEVICE_SETTINGS_SCREEN_PARAMETER = ["Information", "Volume And Brightness", "Wi-Fi", "Bluetooth Cuff", "Dialysate Generator Settings", "Services"] -SettingsHome_Treatment_Text = "Treatment" -SettingsHome_Manager_Text = "Manager" -SettingsHome_Settings_Text = "Settings" - -#Information - -INFORMATION_TITLES = ["Information", "Versions"] -INFORMATION_PARAMETERS = ["Information", "UI Version", "HD Version", "HD FPGA Version", "HD Serial Number", "DG Version", "DG FPGA Version", "DG Serial Number"] -SERIVCES_TITLE = "Services" -SERVICES_PARAMETERS = ["HD Last Service Date", "HD Next Service Date", "DG Last Service Date", "DG Next Service Date"] - -#volume and brightness -VOLUME_AND_BRIGHTNESS_TEXT = "Volume And Brightness" -BRIGHTNESS_TEXT = "Brightness" -ALARM_VOLUME_TEXT = "Alarm Volume" -BACK_TEXT = "BACK" -UNIT_OF_VOLUME_AND_BRIGHTNESS = "%" - - +# dictionary of rejection reason from application source code. +# message location -> denali-> Headers-> common-> MsgDefs.h +REJECTION_REASON = { + 0: "No Active Alarm List", + 1: "REQUEST_REJECT_REASON_NOT_ALLOWED_IN_CURRENT_MODE", # Request is not allowed in the current operating mode + 2: "REQUEST_REJECT_REASON_TIMEOUT_WAITING_FOR_USER_CONFIRM", # Validated request was not confirmed by user in reasonable time + 3: "REQUEST_REJECT_REASON_NOT_IN_TREATMENT_MODE", # Request is not allowed if not in treatment mode + 4: "REQUEST_REJECT_REASON_INVALID_TREATMENT_STATE", # Request is not allowed in current treatment state + 5: "REQUEST_REJECT_REASON_TREATMENT_TOO_CLOSE_TO_FINISHED", # Request is not allowed so near end of treatment + 6: "REQUEST_REJECT_REASON_TREATMENT_TIME_OUT_OF_RANGE", # Treatment duration is out of range + 7: "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_CURRENT", # Treatment time change is less than currently elapsed treatment time + 8: "REQUEST_REJECT_REASON_BLOOD_FLOW_OUT_OF_RANGE", # Blood flow is out of range + 9: "REQUEST_REJECT_REASON_DIAL_FLOW_OUT_OF_RANGE", # Dialysate flow is out of range + 10: "REQUEST_REJECT_REASON_DIAL_VOLUME_OUT_OF_RANGE", # Dialysate flow rate or treatment duration causes dialysate volume to exceed limit + 11: "REQUEST_REJECT_REASON_UF_VOLUME_OUT_OF_RANGE", # Ultrafiltration volume is out of range + 12: "REQUEST_REJECT_REASON_UF_RATE_OUT_OF_RANGE", # Ultrafiltration rate is out of range + 13: "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_MINIMUM", # Treatment time change is less than minimum treatment time + 14: "REQUEST_REJECT_REASON_UF_NOT_IN_PROGESS", # Ultrafiltration is not currently in progress + 15: "REQUEST_REJECT_REASON_UF_NOT_PAUSED", # Ultrafiltration is not currently paused + 16: "REQUEST_REJECT_REASON_SALINE_BOLUS_IN_PROGRESS", # A saline bolus is in progress + 17: "REQUEST_REJECT_REASON_PARAM_OUT_OF_RANGE", # A treatment parameter is out of range + 18: "REQUEST_REJECT_REASON_HEPARIN_PRESTOP_EXCEEDS_DURATION", # The Heparin pre-stop setting is greater than the treatment duration + 19: "REQUEST_REJECT_REASON_ARTERIAL_PRESSURE_LOW_VS_HIGH", # Arterial pressure low and high alarm limits are not inconsistent + 20: "REQUEST_REJECT_REASON_VENOUS_PRESSURE_LOW_VS_HIGH", # Venous pressure low and high alarm limits are inconsistent + 21: "REQUEST_REJECT_REASON_SALINE_MAX_VOLUME_REACHED", # Saline bolus volume maximum has been reached - no more saline allowed + 22: "REQUEST_REJECT_REASON_SALINE_BOLUS_NOT_IN_PROGRESS", # A saline bolus is not in progress + 23: "REQUEST_REJECT_REASON_ACTION_DISABLED_IN_CURRENT_STATE", # Requested user action is disabled in current state + 24: "REQUEST_REJECT_REASON_ALARM_IS_ACTIVE", # Requested user action not allowed while alarm is active + 25: "REQUEST_REJECT_REASON_INVALID_COMMAND", # Requested user action invalid + 26: "REQUEST_REJECT_REASON_TREATMENT_IS_COMPLETED", # The treatment has been completed + 27: "REQUEST_REJECT_REASON_ADDL_RINSEBACK_MAX_VOLUME_REACHED", # Rinseback additional volume maximum has been reached - no more additional rinsebacks allowed + 28: "REQUEST_REJECT_REASON_UF_VOLUME_NOT_SET", # Ultrafiltration volume is not set yet + 29: "REQUEST_REJECT_REASON_NO_PATIENT_CONNECTION_CONFIRM", # The user has not confirmed patient connection + 30: "REQUEST_REJECT_REASON_HEPARIN_PAUSE_INVALID_IN_THIS_STATE", # Heparin cannot be paused if not currently deliverying Heparin + 31: "REQUEST_REJECT_REASON_HEPARIN_NOT_PAUSED", # Heparin cannot be resumed if not paused + 32: "REQUEST_REJECT_REASON_DG_COMM_LOST", # Treatment cannot initiate if DG comm is lost + 33: "REQUEST_REJECT_REASON_DRAIN_NOT_COMPLETE", # Post-treatment reservoirs drain not complete + 34: "REQUEST_REJECT_REASON_DG_NOT_IN_STANDBY_IDLE_STATE", # Treatment cannot initiate if DG is not in standby idle state + 35: "REQUEST_REJECT_REASON_INVALID_REQUEST_FORMAT", # Request message not formatted properly + 36: "REQUEST_REJECT_REASON_INVALID_DATE_OR_TIME", # Given date/time is invalid + 37: "REQUEST_REJECT_REASON____AVAILABLE_1", # Not used - available for use + 38: "REQUEST_REJECT_REASON_BATTERY_IS_NOT_CHARGED", # Battery does not have enough charge to start treatment + 39: "REQUEST_REJECT_REASON_RINSEBACK_NOT_COMPLETED", # Cannot move on to recirculate without completing full rinseback. + 40: "REQUEST_REJECT_REASON_RESERVOIR_ONE_IS_NOT_READY", # Reservoir one fill is not complete + 41: "REQUEST_REJECT_REASON_PUMP_TRACK_NOT_CLOSED", # Pump track is not ready / closed + 42: "REQUEST_REJECT_REASON_DOOR_NOT_CLOSED", # Door is not closed + 43: "REQUEST_REJECT_REASON_SYRINGE_NOT_PRESENT", # Syringe is not present + }