Index: shared/scripts/configuration/config.py =================================================================== diff -u -r854dd010b942b6f214379923f140b93cde3998c9 -r6052b7abfc1d50f6c952a4e12a9bc86c2c5f6e04 --- shared/scripts/configuration/config.py (.../config.py) (revision 854dd010b942b6f214379923f140b93cde3998c9) +++ shared/scripts/configuration/config.py (.../config.py) (revision 6052b7abfc1d50f6c952a4e12a9bc86c2c5f6e04) @@ -20,6 +20,49 @@ COMMON_PATH = os.environ['HOME']+"/Projects" +#instructions_imagelocation +INSTRUCTION_CONF_LOCATION = "/home/denali/Projects/application/resources/settings/Instructions/Instructions.conf" +IMAGE_LOCATION = "file:///home/denali/Projects/application/resources/settings/Instructions/" +EXPECTED_IMAGE_LOCATION = "/home/denali/Projects/application/resources/settings/Instructions/" +SERVICE_CONF_LOCATION = os.environ['HOME']+"/Projects/application/resources/settings/Service.conf" +TREATMENT_LOG_LOCATION = '/home/denali/Desktop/sd-card/treatment/*.log' + +ACCEPTED = True +REJECTED = False +ENABLED = True +DISABLED = False +CURRENT_COLOR = '#000000' +COMPLETE_COLOR = '#4290ec' +ENABLED_COLOR = '#fcfcfc' +INCOMPLETE_COLOR = '#607a91' +OUT_OF_RANGE_COLOR = "#c53b33" + +#main treatment screen +IN_RANGE_COLOR = "#fcfcfc" +SYSTOLIC_LOWER_LIMIT = 60 +SYSTOLIC_UPPER_LIMIT = 250 +DIASTOLIC_LOWER_LIMIT = 40 +DIASTOLIC_UPPER_LIMIT = 200 +HEART_RATE_LOWER_LIMIT = 40 +HEART_RATE_UPPER_LIMIT = 180 + +KEYBOARD_SWITCH = ["ABC", "&123"] + +HEPARIN_TYPE = "UFH 1,000 IU/mL" +ACID_CONCENTRATE = ["Fres. Naturalyte", "08-1251-1", "08-2251-0", "08-3251-9"] +BICARBONATE_CONCENTRATE = "Fres. Centrisol" +DIALYZER_TYPE = ["BB Diacap Pro 13H", "BB Diacap Pro 16H", "BB Diacap Pro 19H", "F Optiflux F160NRe", "F Optiflux F180NRe"] + +COLOR_CODES = {"Aqua": "#81ffff", "Blue": "#017dea", "Blue 2": "#1090d5", "Green": "#29fd2d", "Grey": "#d3d3d3", + "Lavender": "#db98f5", "Light Blue": "#acd7f1", "Light Teal": "#29f1da","Lime": "#b7fc36", + "Magenta":"#fd28fd", "Orange": "#f2721c", "Peach":"#f1979a", "Red": "#c53b33", "Rose":"#fc178d", + "Slate blue":"#7f7ffa", "Violet": "#6435c9", "White": "#ffffff", "Yellow": "#fcfc4d"} + +TREATMENT_UNHIGHLIGHTED_COLOR = "#000000" +TREATMENT_HIGHLIGHTED_COLOR = "#135088" +OPERATIONAL_PARAMETERS = {"Heparin Type": HEPARIN_TYPE, "Acid Concentrate": "Fres. Naturalyte", + "Bicarbonate Concentrate": BICARBONATE_CONCENTRATE, "Dialyzer Type": "BB Diacap Pro 16H"} + #create custom treatment HIGHER_VALUE_OF_BLOOD_FLOW_RATE = 500 LOWER_VALUE_OF_BLOOD_FLOW_RATE = 100 @@ -35,24 +78,125 @@ VENOUS_VALUE_570 = 570 POSITIVE_BUFFER = 10 NEGATIVE_BUFFER = -10 - + +NUM_OF_ALARM_PRIORITIES = 4 # Total number of alarm priorities ACCEPTED = True REJECTED = False + + + NUM_OF_REQUEST_REJECT_REASONS = 43 +NUM_OF_MSG_ID = 289 -CURRENT_COLOR = '#000000' -COMPLETE_COLOR= '#4290ec' -ENABLED_COLOR = '#fcfcfc' -INCOMPLETE_COLOR = '#607a91' -OUT_OF_RANGE_COLOR = "#c53b33" +ALARM_ID_NO_ALARM = 0 +ALARM_ID_OUT_OF_RANGE = 290 + + +# alarm colors +ALARMS_COLORS_HEADER = { + "ALARM_PRIORITY_NONE" : "#438feb", + "ALARM_PRIORITY_LOW" : "#db8f00", + "ALARM_PRIORITY_MEDIUM" : "#db8f00", + "ALARM_PRIORITY_HIGH" : "#831913" +} + +ALARMS_COLORS_BODY = { + "ALARM_PRIORITY_NONE" : "#254670", + "ALARM_PRIORITY_LOW" : "#f5a623", + "ALARM_PRIORITY_MEDIUM" : "#f5a623", + "ALARM_PRIORITY_HIGH" : "#c53b33" +} + +ALARM_MUTE_FLAG = 0B0000001000000000 +ALARM_UNMUTE_FLAG = 0B0000000000000000 + +ALARM_BUTTONS_OK = 0B0000000010111000 + +ALARM_BUTTONS_RESUME = 0B0000000000110000 +ALARM_BUTTONS_RESUME_RINSEBACK = 0B0000000000100000 +ALARM_BUTTONS_RESUME_END = 0B0000000000010000 + +ALARM_BUTTONS_RINSEBACK = 0B0000000000101000 +ALARM_BUTTONS_RINSEBACK_RESUME = ALARM_BUTTONS_RESUME_RINSEBACK +ALARM_BUTTONS_RINSEBACK_END = 0B0000000000001000 + +ALARM_BUTTONS_END = 0B0000000000011000 +ALARM_BUTTONS_END_RESUME = ALARM_BUTTONS_RESUME_END +ALARM_BUTTONS_END_RINSEBACK = ALARM_BUTTONS_RINSEBACK_END + +ALARM_BUTTONS_RESUME_RINSEBACK_END = 0B0000000000000000 +ALARM_BUTTONS_RINSEBACK_RESUME_END = ALARM_BUTTONS_RESUME_RINSEBACK_END +ALARM_BUTTONS_END_RESUME_RINSEBACK = ALARM_BUTTONS_RESUME_RINSEBACK_END + +#standby mode & ultrafiltration +SALINE_BOLUS_CUMULATIVE = 300 +UF_MINIMUM_VALUE = 0 +UF_MAXIMUM_VALUE = 600 + #standby mode GOODMORNING_START_TIME_SEC = 0 GOODEVENING_START_TIME_SEC = 43200 + +UF_MINIMUM_VALUE = 0 +UF_MAXIMUM_VALUE = 600 + +#main treatment pressure +ACCEPTED = True +REJECTED = False +NUM_OF_REQUEST_REJECT_REASONS = 43 + +#pressure +PRESSURE_STEPS = 10 +ARTERIAL_PRESSURE_MINIMUM = -400 +ARTERIAL_PRESSURE_MAXIMUM = +600 +ARTERIAL_PRESSURE_LOW_MIN = -300 +ARTERIAL_PRESSURE_LOW_DEF = -300 +ARTERIAL_PRESSURE_LOW_MAX = +200 +ARTERIAL_PRESSURE_HIGH_MIN = -300 +ARTERIAL_PRESSURE_HIGH_DEF = +100 +ARTERIAL_PRESSURE_HIGH_MAX = +200 + +VENOUS_PRESSURE_MINIMUM = -100 +VENOUS_PRESSURE_MAXIMUM = +700 +VENOUS_PRESSURE_LOW_MIN = -100 +VENOUS_PRESSURE_LOW_DEF = -100 +VENOUS_PRESSURE_LOW_MAX = +600 +VENOUS_PRESSURE_HIGH_MIN = +100 +VENOUS_PRESSURE_HIGH_DEF = +400 +VENOUS_PRESSURE_HIGH_MAX = +600 + +#main_treatment_flows +BLOOD_FLOW_MINIMUM_VALUE = 100 +BLOOD_FLOW_BUFFER = 25 +FLOW_SLIDER_WIDTH_BUFFER = 37 +BLOOD_FLOW_MAXIMUM_VALUE = 500 +DIALYSATE_FLOW_MINIMUM_VALUE = 0 +DIALYSATE_FLOW_MAXIMUM_VALUE = 0 # Seems to be bug. need change +DIALYSATE_FLOW_BUFFER = 50 +DIALYSATE_FLOW_SLIDER_WIDTH_BUFFER = 60 + + + +#main treatment screen +OUT_OF_RANGE_COLOR = "#c53b33" +IN_RANGE_COLOR = "#fcfcfc" +SYSTOLIC_LOWER_LIMIT = 60 +SYSTOLIC_UPPER_LIMIT = 250 +DIASTOLIC_LOWER_LIMIT = 40 +DIASTOLIC_UPPER_LIMIT = 200 +HEART_RATE_LOWER_LIMIT = 40 +HEART_RATE_UPPER_LIMIT = 180 +BLOOD_PRIMING_RANGE = 300 +BLOOD_PRIMING_TARGET_MAXIMUM = 300 + +#tst_pretreatment_screens +NUM_OF_PRETREATMENT_BULLETS = len(PRE_TREATMENT_SCREENS) SALINE_BOLUS_CUMULATIVE = 300 #patient id -PATIENT_ID = { +KEYBOARD_SWITCH = ["ABC", "&123"] +PATIENT_ID_COMBINATION = { "qwerty" : "qwerty", "sampleid" : "sampleid", "abcdefghijklmnop" : "abcdefghijklmnop", @@ -63,9 +207,6 @@ "5432@qwerty" : "5432qwerty" } -KEYBOARD_SWITCH = ["ABC", "&123"] - - #dictionary consist of custom treatment values CREATE_CUSTOM_TREATMENT = { "Blood Flow Rate": 250, @@ -84,7 +225,6 @@ "Rinseback Rate" : 100, "Venous Pressure Limit High" : 590, "Venous Pressure Limit Low": 560 - } #dictionary consist of slider values of treatment parameters @@ -117,6 +257,7 @@ "rinseback_flow_rate" : [50, 25, 187], } + #ultrafilteration volume based on flow parameters. Python list contains Rotational speed, Motor speed, # MC speed, MC current and PWM. TREATMENT_ULTRAFILTRATION_FLOW_PARAMETERS = { @@ -131,20 +272,15 @@ TREATMENT_ULTRAFILTRATION_TESTING_OPTION = { 0 : {"uf_maximum" : 600, "uf_minimum" : 0}, 1 : {"uf_maximum" : 500, "uf_minimum" : 0}, - 2 : {"uf_maximum" : 550, "uf_minimum" : 0}, - 3 : {"uf_maximum" : 300, "uf_minimum" : 0}, - 4 : {"uf_maximum" : 280, "uf_minimum" : 0}, - 5 : {"uf_maximum" : 765, "uf_minimum" : 500}, - 6 : {"uf_maximum" : 680, "uf_minimum" : 450}, - 7 : {"uf_maximum" : 480, "uf_minimum" : 380}, - 8 : {"uf_maximum" : 390, "uf_minimum" : 675}, - 9 : {"uf_maximum" : 290, "uf_minimum" : 125}, + 2 : {"uf_maximum" : 280, "uf_minimum" : 0}, + 3 : {"uf_maximum" : 765, "uf_minimum" : 500}, + 4 : {"uf_maximum" : 680, "uf_minimum" : 450}, + 5 : {"uf_maximum" : 480, "uf_minimum" : 380}, } #tst_pretreatment_screens NUM_OF_PRETREATMENT_BULLETS = len(PRE_TREATMENT_SCREENS) - #dictionary contains saline cumulative and saline delivered value #key : saline cumulative value. #value: saline delivered value @@ -163,6 +299,38 @@ 1000 : 1000 } +# pretreatment_patient_connection +SYSTOLIC_PRESSSURE_120 = 120 +SYSTOLIC_PRESSSURE_113 = 113 +SYSTOLIC_PRESSSURE_150 = 150 +SYSTOLIC_PRESSSURE_175 = 175 +SYSTOLIC_PRESSSURE_200 = 200 +SYSTOLIC_PRESSSURE_200 = 200 +SYSTOLIC_PRESSSURE_251 = 251 +SYSTOLIC_PRESSSURE_59 = 59 +SYSTOLIC_PRESSSURE_15 = 15 +DIASTOLIC_PRESSSURE_25 = 25 +DIASTOLIC_PRESSSURE_39 = 39 +DIASTOLIC_PRESSSURE_74 = 74 +DIASTOLIC_PRESSSURE_80 = 80 +DIASTOLIC_PRESSSURE_85 = 85 +DIASTOLIC_PRESSSURE_60 = 60 +DIASTOLIC_PRESSSURE_150 = 150 +DIASTOLIC_PRESSSURE_200 = 200 +DIASTOLIC_PRESSSURE_201 = 201 +HEART_RATE_VAL_39 = 39 +HEART_RATE_VAL_60 = 60 +HEART_RATE_VAL_70 = 70 +HEART_RATE_VAL_85 = 85 +HEART_RATE_VAL_100 = 100 +HEART_RATE_VAL_101 = 101 +HEART_RATE_VAL_110 = 110 +HEART_RATE_VAL_181 = 181 +HEART_RATE_VAL_200 = 200 +UF_MINIMUM_SLIDER_WIDTH = -2 +UF_MAXIMUM_SLIDER_WIDTH = 638.00 +UF_VALID_RANGE = 700 +TRAINING_INDICATOR_SCREEN = 4 #tst_pretreatment_screens color palettes CURRENT_COLOR = '#000000' @@ -200,3 +368,74 @@ "OPTION_11" : {"uf_maximum" : 1000, "uf_minimum" : 0}, "OPTION_12" : {"uf_maximum" : 1250, "uf_minimum" : 0}, } + + +#pre-treatment_priming +NOT_VISIBLE = False +VISIBLE = True +FOCUS = True +NOT_IN_FOCUS = False + +#Filter Flush + +MAXIMUM_COUNTDOWN_TIME = 300 +MINIMUM_COUNTDOWN_TIME = 0 +TIME_OUT_DURATION_300 = 300 +TIME_OUT_DURATION_200 = 200 +TIME_OUT_DURATION_100 = 100 +COUNT_DOWN_TIME_100 = 100 +MINIMUM_COUNTDOWN_TIME = 0 +CONSUMABLE_SELF_TEST_BICARB_PUMP_CHECK_STATE = 3 + +VALID = True +INVALID = False + +#post treatment review +ACID_CONCENTRATE_POST = ["Fres. Naturalyte", "08-1251-1", "08-2251-0", "08-3251-9", "08-3251-9"] +BRIGHTNESS_MIN_VAL = 20 +BRIGHTNESS_MAX_VAL = 100 +VOLUME_MIN_VAL = 20 +VOLUME_MAX_VAL = 100 + +#dictionary consist of review parameters values of post treatment +POST_TREATMENT_REVIEW_PARAMETER_RANGE = { + "Patient ID": ["abcd", "xyz"], + "Heparin Stop": [0, 101], + "Device ID": [1234, 1234], + "Heparin Delivered Volume": [10.1, 10.5], + "Blood Flow Rate": [100, 125], + "Treatment Start DateTime": [1654519251, 1623382321], + "Dialysate Flow Rate": [100, 150], + "Treatment End DateTime": [1654519251, 1623382321], + "Treatment Duration": [70, 75], + "Water Sample Test Result": [0, 1], + "Actual Treatment Duration": [62, 126], + "Dialysate Volume Used": [4.0, 6.0], + "Acid ConcentrateType": [0, 1], + "Prescribed UF Volume": [0.3, 0.5], + "Bicarbonate Concentrate Type": [0, 0], + "Target UF Volume": [10.1, 10.5], + "Potassium Concentration": [60, 75], + "Actual UF Volume": [0.3, 0.5], + "Calcium Concentration": [3, 56], + "Prescribed UF Rate": [0.1, 0.55], + "Bicarbonate Concentration": [14, 50], + "Target UF Rate": [0.2, 0.56], + "Sodium Concentration": [4, 6], + "Actual UF Rate": [0.5, 0.6], + "Dialysate Temperature": [35.0, 35.5], + "Saline Bolus Volume": [300, 250], + "Dialyzer Type": [0, 1], + "Average Blood Flow": [54.3, 67.3], + "Heparin Type": [0, 0], + "Average Dialysate Flow": [0.6, 0.5], + "Average Dialysate Temp": [35.0, 35.5], + "Heparin Bolus Volume": [0.0, 0.1], + "Average Arterial Pressure": [0.0, 11.56], + "Heparin Dispense Rate": [0.0, 0.1], + "Average Venous Pressure": [20.0, 101.45], +} + +#end-treatment states +NUM_OF_REQUEST_REJECT_REASONS = 43 + Index: shared/scripts/configuration/strings.py =================================================================== diff -u -r854dd010b942b6f214379923f140b93cde3998c9 -r6052b7abfc1d50f6c952a4e12a9bc86c2c5f6e04 --- shared/scripts/configuration/strings.py (.../strings.py) (revision 854dd010b942b6f214379923f140b93cde3998c9) +++ shared/scripts/configuration/strings.py (.../strings.py) (revision 6052b7abfc1d50f6c952a4e12a9bc86c2c5f6e04) @@ -1,3 +1,4 @@ +# -*- coding: utf-8 -*- ########################################################################### # @@ -8,45 +9,67 @@ # # @file strings.py # -# @author (last) LTTS -# @date (last) 18-Jan-2022 -# +# @author (last) LTTS +# @date (last) 14-June-2022 ############################################################################ +#pretreatment_screen_bullets +PRE_TREATMENT_SCREENS = ["Create" , "Sample" , "Consumables" , "Disposables" , "Prime" , "Ultrafiltration" , "BP/HR" , "Connection" , "Start"] +POST_TREATMENT_SCREENS = ["Disconnection", "Review", "Disposables", "Disinfection"] -#standby mode BLOOD_PRIMING_TEXT = "Blood Priming" SALINE_UNIT = "mL" BLOOD_PRIMING_UNIT = "mL" BLOOD_PRIMING_VALUE_0 = "0" -BLOOD_PRIMING_DEFAULT_VALUE = BLOOD_PRIMING_VALUE_0 + BLOOD_PRIMING_UNIT +BLOOD_PRIMING_DEFAULT_VALUE = BLOOD_PRIMING_VALUE_0 + " " + BLOOD_PRIMING_UNIT -PRE_TREATMENT_SCREENS = ["Create" , "Sample" , "Consumables" , "Disposables" , "Prime" , "Ultrafiltration" , "BP/HR" , "Connection" , "Start"] +#UF treatment +ULTRAFILTRATION_PAUSED_TEXT = "Ultrafiltration Paused" +RESUME_TEXT = "RESUME ULTRAFILTRATION" +EDIT_TEXT = "EDIT ULTRAFILTRATION VOLUME" +TITLE_TEXT = "ULTRAFILTRATION VOLUME (L)" -# dictionary of rejection reason from application source code. -# message location -> denali-> Headers-> common-> MsgDefs.h -# pretreatment_patient_connection -DIASTOLIC_TEXT = "diastolic" -SYSTOLIC_TEXT = "systolic" -OUT_OF_RANGE_COLOR = "#c53b33" -IN_RANGE_COLOR = "#fcfcfc" -HEART_RATE_TITLE = "Heart Rate" -BLOOD_PRESSURE_TITLE = "Blood Pressure" -BLOOD_PRESSURE_UNIT = "mmHg" -HEART_RATE_UNIT = "BPM" -PATIENT_CONNECTION_TEXT = "Patient Connection" -UF_VOLUME_TEXT = "Ultrafiltration Volume (L)" -UF_TITLE_TEXT = "Ultrafiltration Setup" -BP_HR_TEXT = "BP/HR" -SKIP_TEXT = "SKIP" -TUTORIAL_TEXT = { - 0 : "Wash your hands and establish vascular access per your clinic's instructions.", - 1 : "Pinch arterial clamp and venous clamp on located on the cartridge patient lines.", - 2 : "Remove arterial and venous shunt.", - 3 : "Connect arterial and venous cartridge lines to your patient access lines." -} +#recirculate screens +RECIRCULATE_TEXT = "Recirculate" +RECONNECT_BUTTON_TEXT = "RECONNECT" +RECONNECT_TEXT = "Reconnect" -PRE_TREATMENT_SCREENS = ["Create" , "Sample" , "Consumables" , "Disposables" , "Prime" , "Ultrafiltration" , "BP/HR" , "Connection" , "Start"] +#Blood Priming +BLOOD_PRIMING_TEXT = "Blood Priming" +SALINE_UNIT = "mL" +ACK_REQ_STATUS = 'Ack Req' +ACK_BAK_STATUS = 'Ack Bak' + +#standby mode +LIQUID_UNIT = "mL" + + +#main treatment pressure +PRESSURE_TITLE = "PRESSURES" +ARTERIAL_TITLE = "Arterial" +VENOUS_TITLE = "Venous" +VENOUS_UOM = "mmHg" +ARTERIAL_UOM = "mmHg" +LOW_TEXT = "LOW" +HIGH_TEXT = "HIGH" + +#main-treatment heparin +HEPARIN_TEXT = "HEPARIN" +HEPARIN_UNIT = "mL" +HEPARIN_DELIVERY_TEXT = "HEPARIN DELIVERY" +HEPARIN_DELIVERY_OFF_TEXT = "OFF" +HEPARIN_STOP_TEXT = "Delivery Stopped" +HEPARIN_RESUME_DELIVERY_TEXT = "RESUME DELIVERY" +HEPARIN_BOLUS_ACTIVE_TEXT = "Bolus Active" +HEPARIN_BOLUS_DISPENSING_TEXT = "Dispensing Active" +HEPARIN_PAUSE_DELIVERY_TEXT = "PAUSE DELIVERY" +HEPARIN_MAXIMUM_VOLUME_DELIVERED_TEXT = "Maximum Cumulative Heparin Volume Delivered" +HEPARIN_SYRINGE_EMPTY_TEXT = "Syringe Empty" +HEPARIN_DISPENSING_RATE = "Heparin Dispensing Rate" +HEPARIN_BOLUS_VOLUME = "Heparin Bolus Volume" +HEPARIN_STOP_TIME = "Heparin Stop Time" +HEPARIN_TYPE_TITLE = "Heparin Type" + # dictionary of rejection reason from application source code. # message location -> denali-> Headers-> common-> MsgDefs.h REJECTION_REASON = { @@ -96,52 +119,353 @@ 43: "REQUEST_REJECT_REASON_SYRINGE_NOT_PRESENT", # Syringe is not present } +ALARM_ID_AND_MESSAGES = { + 1: "Stuck button POST failure.\nStop or Off button detected to be pressed for at least 1 second during test shortly after power up.", + 2: "HD FPGA POST failure.", + 3: "DG FPGA POST failure.", + 4: "HD Watchdog POST failure.", + 5: "DG Watchdog POST failure.", + 6: "UI communication POST failure.\nUI failed to communicate within a reasonable time after power up.", + 7: "Real-time clock configuration error.", + 8: "HD accelerometer failed POST.", + 9: "DG accelerometer failed POST." , + 10: "RTC or MCU timer inaccurate.", + 11: "DG heaters failed POST.", + 12: "HD firmware image integrity POST test failed.", + 13: "DG firmware image integrity POST test failed.", + 14: "HD blood flow invalid calibration.", + 15: "HD dialysate flow invalid calibration.", + 16: "HD alarm audio failed POST.", + 17: "HD UI POST failed.", + 18: "DG load cells invalid calibration record.", + 19: "DG flow sensors invalid calibration record.", + 20: "DG conductivity sensors invalid calibration record.", + 21: "DG drain line volume invalid calibration record.", + 22: "DG reservoirs invalid calibration record.", + 23: "DG acid concentrate calibration record.", + 24: "DG bicarb concentrate calibration record.", + 25: "DG accelerometer invalid calibration record.", + 26: "HD accelerometer invalid calibration record.", + 27: "HD blood flow invalid calibration record.", + 28: "HD dialyzer flow invalid calibration record.", + 29: "HD heparin force sensor invalid calibration record.", + 30: "HD Software fault.\nSoftware found itself in an unexpected state.", + 31: "Blood pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running.", + 32: "Blood pump failed motor off check.\nMeasured speed while commanded off.", + 33: "Blood pump failed motor direction check.\nMeasured vs commanded.", + 34: "Blood pump failed rotor speed check.\nMismatch with rotor and motor speeds.", + 35: "Dialysis inlet pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running.", + 36: "Dialysis inlet pump failed motor off check.\nMeasured speed while commanded off.", + 37: "Dialysis inlet pump failed motor direction check.\nMeasured vs commanded.", + 38: "Dialysis inlet pump failed rotor speed check.\nMismatch with rotor and motor speeds.", + 39: "Dialysis outlet pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running.", + 40: "Dialysis outlet pump failed motor off check.\nMeasured speed while commanded off.", + 41: "Dialysis outlet pump failed motor direction check.\nMeasured vs commanded.", + 42: "Dialysis outlet pump failed rotor speed check.\nMismatch with rotor and motor speeds.", + 43: "Watchdog expired error.\nWatchdog was not \"pet\" within the appropriate time.", + 44: "User interface communication timeout.", + 45: "Too many bad CRCs detected on received system messages.", + 46: "System message that required acknowledgment was not acknowledged.", + 47: "Ultrafiltration rate is too high error during treatment.", + 48: "Ultrafiltration volume accuracy error during treatment.", + 49: "HD FPGA communication down for too long.", + 50: "FPGA not accepting commanded valve states.", + 51: "Blood pump failed motor speed check.\nMeasured vs commanded.", + 52: "Dialysate inlet pump failed motor speed check.\nMeasured vs commanded.", + 53: "Dialysate outlet pump failed motor speed check.\nMeasured vs commanded.", + 54: "HD critical data integrity check failed.", + 55: "DG critical data integrity check failed.", + 56: "HD accelerometer error (no readings or FPGA reports error).", + 57: "DG accelerometer error (no readings or FPGA reports error).", + 58: "HD valve homing failed.", + 59: "HD valve transition time out.", + 60: "HD valve not functional.", + 61: "HD valve current out of range.", + 62: "HD valve position out of target.", + 63: "FPGA reports failure reading arterial pressure sensor.", + 64: "FPGA reports failure reading venous pressure sensor.", + 65: "HD requests DG command with invalid parameter fault.", + 66: "HD blood leak sensor set point set failure.", + 67: "HD blood pump occlusion self-test failure alarm.", + 68: "HD active reservoir recirculation out of range.", + 69: "HD blood leak sensor invalid calibration record.", + 70: "HD arterial pressure self-test failure alarm." , + 71: "HD venous pressure self-test failure alarm.", + 72: "HD blood flow meter status check self-test failure alarm.", + 73: "HD dialysate flow meter status check self-test failure alarm.", + 74: "HD blood leak detector self-test failure alarm.", + 75: "HD syringe pump self-test failure alarm.", + 76: "HD monitored voltage is out of range.", + 77: "DG monitored voltage is out of range.", + 78: "HD syringe pump direction (from encoder) error.", + 79: "HD syringe pump direction (from controller) error.", + 80: "HD syringe pump fault reported by FPGA.", + 81: "HD syringe pump over travel error.", + 82: "HD syringe pump DAC write failure.", + 83: "HD syringe pump is running while the BP is off.", + 84: "HD venous pressure sensor not being read.", + 85: "HD pump track latch opened alarm.", + 86: "HD BP occlusion sensor not being read.", + 87: "DG heating invalid calibration record.", + 88: "DG concentrate pumps hall sensor out of range.", + 89: "HD BP occlusion sensor error.", + 90: "This alarm ID is available for use.", + 91: "HD No dialysate flow data receive in the last 3 seconds.", + 92: "DG conductivity sensor bad status.", + 93: "This alarm ID is available for use.", + 94: "This alarm ID is available for use.", + 95: "This alarm ID is available for use.", + 96: "Inlet water temperature in high range.", + 97: "Fill conductivity out of range.", + 98: "HD battery communication fault.", + 99: "HD syringe pump stall alarm.", + 100: "HD no cartridge self-test timeout.", + 101: "HD dry self-test timeout.", + 102: "Real-time clock communication error.", + 103: "HD non-volatile calibration group invalid record CRC.", + 104: "Air trap level sensors reporting illegal combination of air/fluid.", + 105: "DG non-volatile system group invalid record CRC.", + 106: "DG inlet water conductivity is greater than threshold.", + 107: "HD reports DG restarted fault.", + 108: "HD syringe pump ADC error.", + 109: "HD syringe pump volume check error.", + 110: "HD syringe pump speed check error.", + 111: "HD syringe pump not stopped in off state error.", + 112: "HD blood leak detector fault.", + 113: "HD arterial air bubble detector self-test failure.", + 114: "HD venous air bubble detector self-test failure.", + 115: "DG temperature sensor out of range.", + 116: "DG temperature sensor ADC out of range.", + 117: "DG primary heater internal temperature out of range.", + 118: "DG primary heater cold junction temperature out of range.", + 119: "DG trimmer heater internal temperature out of range.", + 120: "DG trimmer heater cold junction temperature out of range.", + 121: "DG main primary heater voltage out of range.", + 122: "DG small primary heater voltage out of range.", + 123: "DG trimmer heater voltage out of range.", + 124: "HD end of treatment alarm (high priority).", + 125: "Blood sitting too long after treatment stopped by user alarm (>5 min).", + 126: "HD blood leak detected alarm.", + 127: "Venous pressure too low during treatment." , + 128: "HD venous air bubble detected alarm.", + 129: "HD venous air bubble detected rinseback alarm.", + 130: "Venous pressure too high during treatment.", + 131: "Arterial pressure too low during treatment.", + 132: "Arterial pressure too high during treatment.", + 133: "DG fluid leak detected alarm.", + 134: "HD fluid leak detected alarm." , + 135: "HD experienced large acceleration.", + 136: "DG experienced large acceleration.", + 137: "HD tilt exceeds maximum.", + 138: "DG tilt exceeds maximum.", + 139: "HD AC power lost alarm.", + 140: "Dialysate generator communication timeout.", + 141: "Air trap fill timeout during treatment.", + 142: "Blood pump occlusion detected.", + 143: "DG dialysate temperature sensors drift timeout.", + 144: "DG software configuration record invalid CRC.", + 145: "Concentrate conductivity after adding acid out of range alarm.", + 146: "Dialysate conductivity out of range.", + 147: "Wait for the DG to produce dialysate.", + 148: "Inlet water temperature too high.", + 149: "Alarm ID available for use.", + 150: "Inlet water conductivity in high range.", + 151: "Inlet water conductivity in low range.", + 152: "Inlet water pressure in low range.", + 153: "HD prime completed high priority alarm.", + 154: "EEPROM operations (read, write, erase) failure.", + 155: "DG software configuration record invalid CRC.", + 156: "HW usage data (treatment time in HD and total consumed water in DG) failure.", + 157: "DG chemical disinfect prime acid line timeout.", + 158: "Inlet water temperature is in the low range.", + 159: "Dialysate inlet pump failed flow vs motor speed check.", + 160: "Blood pump rotor speed too high.", + 161: "This alarm ID is available for use.", + 162: "This alarm ID is available for use.", + 163: "HD sees primary load cell for reservoir 1 change too much too fast.", + 164: "HD sees primary load cell for reservoir 2 change too much too fast.", + 165: "HD in treatment rinseback operation timeout.", + 166: "HD in treatment re-circ sub-mode for too long.", + 167: "HD cartridge door opened alarm.", + 168: "HD active reservoir depletion timeout.", + 169: "Dialysate flow rate out of range.", + 170: "HD syringe empty alarm.", + 171: "HD syringe pump occlusion alarm.", + 172: "HD syringe pump not enough Heparin alarm.", + 173: "HD arterial air bubble detected alarm.", + 174: "HD arterial air bubble detected rinseback alarm.", + 175: "HD pump direction status error.", + 176: "HD active reservoir is full during treatment and DG not ready to switch reservoirs.", + 177: "DG software fault.\nSoftware found itself in an unexpected state.", + 178: "HD communication timeout.", + 179: "DG FPGA communication down for too long.", + 180: "DG load cell ADC error.", + 181: "DG load cells weight out of range for tare.", + 182: "DG load cells invalid calibration.", + 183: "DG invalid load cell value.", + 184: "Inlet or Outlet UV reactor not healthy.", + 185: "DG fan RPM out of range.", + 186: "DG concentrate pump fault.", + 187: "DG concentrate pump CP1 speed control error.", + 188: "DG concentrate pump CP2 speed control error.", + 189: "DG drain pump RPM out of range.", + 190: "DG drain pump off fault.", + 191: "DG flow rate out of upper range.", + 192: "DG flow rate out of lower range.", + 193: "RO pump flow rate out of range.", + 194: "DG RO pump duty cycle out of range.", + 195: "DG RO pump pressure out of range.", + 196: "DG temperature sensor error flag fault.", + 197: "DG temperature sensors ADC fault.", + 198: "DG heaters cold junction temperature out of range.", + 199: "DG heaters fault.", + 200: "DG thermistors/sensors temperature out of range.", + 201: "Inlet water quality is bad (temperature, conductivity, pressure).", + 202: "Inlet water pressure fault.", + 203: "Pressure sensor fault.", + 204: "RO rejection ratio out of range.", + 205: "Conductivity sensor fault.", + 206: "DG dialysate fill runs out of time.", + 207: "DG flow meter check failure alarm.", + 208: "DG primary heater on with no flow time out.", + 209: "DG drain circulation line timeout.", + 210: "HD battery pack detected an error.", + 211: "Blood sitting too long warning (>4 min).", + 212: "HD end of treatment alarm (user not acting to end treatment).", + 213: "HD prime completed medium priority alarm.", + 214: "HD Saline bolus volume check failure.", + 215: "HD rinseback volume check failure.", + 216: "HD end treatment sub-mode timeout alarm.", + 217: "HD blood prime volume check failure.", + 218: "HD syringe detected alarm.", + 219: "HD syringe pump syringe removed alarm.", + 220: "HD battery pack SOC is too low.", + 221: "HD Saline bag is empty.", + 222: "HD dialysate temperature too high alarm.", + 223: "HD dialysate temperature too low alarm.", + 224: "Treatment stopped by user action.", + 225: "HD end of treatment warning.", + 226: "HD prime completed low priority alarm.", + 227: "HD prime out of time alarm.", + 228: "HD time out on prime sub-mode purge air state.", + 229: "HD prime dialysate dialyzer time out alarm.", + 230: "HD prime dialysate bypass time out alarm.", + 231: "HD pre-treatment mode dry self-tests failure.", + 232: "HD pre-treatment mode wet self-tests failure.", + 233: "RTC battery low.", + 234: "RTC (i.e read time) or RAM operations failure (read or write).", + 235: "HD in treatment stopped sub-mode after rinseback completed (no escalation).", + 236: "HD needs new cartridge to be installed.", + 237: "HD prime saline dialyzer time out alarm.", + 238: "HD no cartridge loaded or installed improperly alarm.", + 239: "HD fail to remove cartridge alarm.", + 240: "Bicarb conductivity out of range during bicarb pump check alarm.", + 241: "DG reservoir drain time out.", + 242: "DG reservoir fill time out.", + 243: "DG reservoir leak time out.", + 244: "DG temperature sensors difference out of range.", + 245: "DG heat disinfect target temperature time out (could not reach to temperature).", + 246: "DG heat disinfect inlet pressure and temperature sensors out of range.", + 247: "DG heat disinfect inlet conductivity and temperature out of range.", + 248: "DG chemical disinfect could not reach to target temperature.", + 249: "DG chemical disinfect inlet pressure and temperature sensors out of range.", + 250: "DG chemical disinfect inlet conductivity and temperature out of range.", + 251: "HD invalid system record.", + 252: "HD invalid service record.", + 253: "DG invalid system record.", + 254: "DG invalid service record.", + 255: "HD and UI software builds are not compatible.", + 256: "HD and DG software builds are not compatible.", + 257: "DG FPGA power out timeout.", + 258: "HD FPGA power out timeout.", + 259: "HD temperatures out of range.", + 260: "UI POST Application Integrity (Sha256Sum) failure.", + 261: "UI POST CANBus failure.", + 262: "UI POST Display failure.", + 263: "UI POST Touch failure.", + 264: "UI POST SD-Card failure.", + 265: "UI POST RTC failure.", + 266: "UI POST WiFi failure.", + 267: "UI POST Bluetooth failure.", + 268: "UI POST Ethernet failure.", + 269: "UI POST Sound failure.", + 270: "HD POST Safety Shutdown failure.", + 271: "DG POST Safety Shutdown failure.", + 272: "HD Fan RPM out of range.", + 273: "HD measured blood pump flow rate is out of range.", + 274: "HD measured dialysate inlet pump flow rate is out of range.", + 275: "HD arterial pressure sensor is reading out of range.", + 276: "HD venous pressure sensor is reading out of range.", + 277: "HD BP occlusion sensor is reading out of range.", + 278: "HD active reservoir weight out of range.", + 279: "DG dialysate drain time out.", + 280: "HD arterial pressure sensor read timeout error.", + 281: "Acid concentration bottle low volume alarm.", + 282: "Bicarbonate concentration bottle low volume alarm.", + 283: "DG load cells weight out of range.", + 284: "DG load cells primary/back up drift out of range.", + 285: "HD treatment recirculate timeout warning.", + 286: "HD treatment rinseback complete timeout warning.", + 287: "HD processor clock speed checks against FPGA clock failure.", + 288: "DG trimmer heater on with flow timeout.", + 289: "DG dialysate or concentrate caps not closed." + } + +#Alarm List +UNDEFINED_ALARM_ID_MSG = "ALARM_ID_UNDEFINED" +ALARM_TITLE = "Alarm" +ALARM_LIST_TITLE = "Alarm list" +ALARM_PRIORITIES = {1: "LOW", 2: "MEDIUM", 3: "HIGH"} + +ALARM_PRIORITY_OPTIONS = { + 0 : 'ALARM_PRIORITY_NONE' , + 1 : 'ALARM_PRIORITY_LOW' , + 2 : 'ALARM_PRIORITY_MEDIUM', + 3 : 'ALARM_PRIORITY_HIGH', +} + +#Setting +EXPORT_TEXT ="Export" +DEVICE_SETTINGS_TEXT = "Device Settings" +DEVICE_SETTINGS_SCREEN_PARAMETER = ["Information", "Volume And Brightness", "Wi-Fi", "Bluetooth Cuff", "Dialysate Generator Settings", "Services"] + +#UF treatment +LIQUID_UNIT = "mL" + #create custom treatment -PATIENT_ID = "demopatientid" TREATMENT_TITLE = "Create a Custom Treatment" -HEPARIN_TYPE = "UFH 1,000 IU/mL" -ACID_CONCENTRATE = ["Fres. Naturalyte", "08-1251-1", "08-2251-0", "08-3251-9"] -BICARBONATE_CONCENTRATE = "Fres. Centrisol" -DIALYZER_TYPE = ["BB Diacap Pro 13H", "BB Diacap Pro 16H", "BB Diacap Pro 19H", "F Optiflux F160NRe", "F Optiflux F180NRe"] CONFIRM_TREATMENT_TITLE = "Confirm Treatment" PRESCRIPTION_TITLE = "PRESCRIPTION" OPERATING_PARAMETERS_TITLE = "OPERATING PARAMETERS" -COLOR_CODES = {"Aqua": "#81ffff", "Blue": "#017dea", "Blue 2": "#1090d5", "Green": "#29fd2d", "Grey": "#d3d3d3", - "Lavender": "#db98f5", "Light Blue": "#acd7f1", "Light Teal": "#29f1da","Lime": "#b7fc36", - "Magenta":"#fd28fd", "Orange": "#f2721c", "Peach":"#f1979a", "Red": "#c53b33", "Rose":"#fc178d", - "Slate blue":"#7f7ffa", "Violet": "#6435c9", "White": "#ffffff", "Yellow": "#fcfc4d"} - -CURRENT_COLOR = '#000000' -COMPLETE_COLOR= '#4290ec' -ENABLED_COLOR = '#fcfcfc' -INCOMPLETE_COLOR = '#607a91' -PATIENT_ID_TEXT = "Patient ID" -PATIENT_ID = "demopatientid" +PATIENT_ID_TEXT = "Patient ID" BLOOD_FLOW_RATE = "Blood Flow Rate" DIALYSATE_FLOW_RATE = "Dialysate Flow Rate" DURATION = "Duration" -HEPARIN_DISPENSING_RATE = "Heparin Dispensing Rate" -HEPARIN_BOLUS_VOLUME = "Heparin Bolus Volume" -HEPARIN_STOP_TIME = "Heparin Stop Time" SALINE_BOLUS_VOLUME = "Saline Bolus Volume" -HEPARIN_TYPE_TITLE = "Heparin Type" + +#main treatment screen +VITALS_TITLE = "VITALS" +HEART_RATE_TITLE = "Heart Rate" +BLOOD_PRESSURE_TITLE = "Blood Pressure" +BLOOD_PRESSURE_UNIT = "mmHg" +HEART_RATE_UNIT = "BPM" + +PATIENT_ID = "demopatientid" SALINE_BOLUS_TITLE = "Saline Bolus" ACID_CONCENTRATE_TITLE = "Acid Concentrate" BICARBONATE_CONCENTRATE_TITLE = "Bicarbonate Concentrate" DIALYZER_TYPE_TITLE = "Dialyzer Type" DIALYSATE_TEMPERATURE = "Dialysate Temperature" BLOOD_PRESSURE_MEASUREMENT_INTERVAL = "Blood Pressure Measurement Interval" RINSEBACK_FLOW_RATE = "Rinseback Flow Rate" - -CREATE_TREATMENT_PARAMETERS = ["Blood Flow Rate", "Dialysate Flow Rate", "Duration","Heparin Dispensing Rate", - "Heparin Bolus Volume","Heparin Stop Time", "Saline Bolus", "Dialysate Temperature", - "Blood Pressure Measurement Interval", "Rinseback Flow Rate"] -TREATMENT_UNHIGHLIGHTED_COLOR = "#000000" -TREATMENT_HIGHLIGHTED_COLOR = "#135088" OFF_TEXT = "OFF" BACK_TEXT = "BACK" CONTINUE_TEXT = "CONTINUE" +CREATE_TREATMENT_PARAMETERS = ["Blood Flow Rate", "Dialysate Flow Rate", "Duration","Heparin Dispensing Rate", + "Heparin Bolus Volume","Heparin Stop Time", "Saline Bolus", "Dialysate Temperature", + "Blood Pressure Measurement Interval", "Rinseback Flow Rate"] + PRESCRIPTION_DETAILS = { "Blood Flow Rate": "mL/min", "Dialysate Flow Rate": "mL/min", "Duration": "min", "Heparin Dispensing Rate": "mL/hr", @@ -152,13 +476,52 @@ "Rinseback Rate" : "mL/min", "Venous Pressure Limit High": "mmHg", "Venous Pressure Limit Low": "mmHg" } - -OPERATIONAL_PARAMETERS = {"Heparin Type": HEPARIN_TYPE, "Acid Concentrate": "Fres. Naturalyte", - "Bicarbonate Concentrate": BICARBONATE_CONCENTRATE, "Dialyzer Type": "BB Diacap Pro 16H"} - -LIQUID_UNIT = "mL" +#Time_Duration +TREATMENT_PAUSED_TEXT = "Treatment Paused" +#pre-treatment +CONSUMABLE_SELF_TEST_TEXT = "Consumables Self Test" +BICARB_PUMP_CHECK_TEXT = "BiCarb Pump Check" +ACID_PUMP_CHECK_TEXT = "Acid Pump Check" +SELF_TEST_COMPLETE_TEXT = "Self Test Complete!" +BUSY = "Busy" +CHECK = "Check" +BEGIN_PRIME_TITLE = "Begin Prime" +PRIMING_TITLE = "Priming" +SYSTEM_SELF_TEST_TITLE = "System Self Test" +FILTER_FLUSH_TITLE = "Filter Flush" + +#Pre-Treatment Disposables +NEXT_BUTTON_TEXT = "NEXT" +BACK_BUTTON_TEXT = "BACK" +CONFIRM_BUTTON_TEXT = "CONFIRM" + +#Pre_treatment_water_sample +SAMPLE_TEXT = "Sample" +CREATE_TEXT = "Create" +WATER_SAMPLE_BUTTON_TEXT = "WATER SAMPLE" +PASS_TEXT = "PASS" +FAIL_TEXT = "FAIL" +OK_TEXT = "OK" + +#Vitals & pretreatment_patient_connection +SYSTOLIC_TEXT = "systolic" +DIASTOLIC_TEXT = "diastolic" + +#priming +TEST_DRY_STEPS = ["Used Cartridge Check", "Occlusion Sensors Check", "Pressure Sensors Check", "Syringe Pump Check"] +PRIMING_STEPS = ["Blood Circuit Priming", "Dialysate Circuit Priming", "Wet Self Tests"] +SELF_TEST_COMPLETION_MSG = "Self Test Complete!" +PRIMING_COMPLETE_MSG = "Priming Complete!" + +#main_treatment_flows +FLOW_UNIT = "mL/min" +BLOOD_FLOW_TEXT = "blood" +DIALYSATE_FLOW_TEXT = "dialysate" + +LIQUID_UNIT = "mL" + #tst_treatment_monitoring FLOWS_TEXT = "FLOWS" BLOOD_UNIT = "mL/min" @@ -175,6 +538,439 @@ SALINE_BOLUS = "SALINE BOLUS" VOLUME_DELIVERED = "Volume Delivered" CUMULATIVE_DELIVERED = "Cumulative Delivered" + +#post-treatment +PATIENT_DISCONNECTION_TEXT = "Patient Disconnection" +REVIEW_TEXT = "Review" +PATIENT_DISCONNECTION_CONFIRM_BUTTON_TEXT = "CONFIRM" +DISPOSABLE_TEXT = "Disposables" +NEXT_TEXT = "NEXT" +BACK_TEXT = "BACK" +CONFIRM_TEXT = "CONFIRM" +DISPOSABLES_REMOVAL_TEXT = "Disposables Removal" + +#post treatment review +TREATMENT_REVIEW_TITLE_TEXT = "Treatment Review" +POST_TREATMENT_REVIEW_SCREEN_UNITS = { + "Patient ID" : "", + "Heparin Stop" : "min", + "Device ID" : "", + "Heparin Delivered Volume": "mL", + "Blood Flow Rate" : "mL/min", + "Treatment Start DateTime" : "", + "Dialysate Flow Rate" : "mL/min", + "Treatment End DateTime" : "", + "Treatment Duration" : "min", + "Water Sample Test Result": "", + "Actual Treatment Duration":"min", + "Dialysate Volume Used" : "L", + "Acid ConcentrateType" : "", + "Prescribed UF Volume" : "L", + "Bicarbonate Concentrate Type" : "", + "Target UF Volume" : "L", + "Potassium Concentration" : "mEg/L", + "Actual UF Volume" : "L", + "Calcium Concentration" :"mEg/L", + "Prescribed UF Rate" : "mL/min", + "Bicarbonate Concentration" : "mEg/L", + "Target UF Rate": "mL/min", + "Sodium Concentration" : "mEg/L", + "Actual UF Rate": "mL/min", + "Dialysate Temperature" :"°C", + "Saline Bolus Volume" : "mL", + "Dialyzer Type" : "", + "Average Blood Flow" : "mL/min", + "Heparin Type" : "IU/mL", + "Average Dialysate Flow" : "mL/min", + "Heparin Concentration" : "IU/mL", + "Average Dialysate Temp" : "°C", + "Heparin Bolus Volume": "mL", + "Average Arterial Pressure" : "mmHg", + "Heparin Dispense Rate" : "mL/hr", + "Average Venous Pressure" : "mmHg", + } + +#Information +INFORMATION_TITLES = ["Information", "Versions"] +INFORMATION_PARAMETERS = ["Information", "UI Version", "HD Version", "HD FPGA Version", "HD Serial Number", "DG Version", "DG FPGA Version", "DG Serial Number"] +SERIVCES_TITLE = "Services" +SERVICES_PARAMETERS = ["HD Last Service Date", "HD Next Service Date", "DG Last Service Date", "DG Next Service Date"] + + +#volume and brightness +VOLUME_AND_BRIGHTNESS_TEXT = "Volume And Brightness" +BRIGHTNESS_TEXT = "Brightness" +ALARM_VOLUME_TEXT = "Alarm Volume" +UNIT_OF_VOLUME_AND_BRIGHTNESS = "%" + +#services +SHUTDOWN_TEXT = "SHUTDOWN" + +# pretreatment_patient_connection & ui logs +ACK_REQ_STATUS = 'Ack Req' +ACK_BAK_STATUS = 'Ack Bak' +PATIENT_CONNECTION_TEXT = "Patient Connection" +UF_VOLUME_TEXT = "Ultrafiltration Volume (L)" +UF_TITLE_TEXT = "Ultrafiltration Setup" +BP_HR_TEXT = "BP/HR" +SKIP_TEXT = "SKIP" +TUTORIAL_TEXT = { + 0 : "Wash your hands and establish vascular access per your clinic's instructions.", + 1 : "Pinch arterial clamp and venous clamp on located on the cartridge patient lines.", + 2 : "Remove arterial and venous shunt.", + 3 : "Connect arterial and venous cartridge lines to your patient access lines." +} + +#End treatment +RINSEBACK_BUTTON_TEXT = "START RINSEBACK" +END_TREATMENT_COMPLETE_STATE_TEXT = "Treatment Complete" +END_TREATMENT_COMPLETE_PAUSED_STATE_TEXT = "Treatment Complete Paused" + +#rinseback-setup +RINSE_BACK_SETUP_TEXT = "Rinseback Setup" +RINSEBACK_BUTTON_TEXT = "START RINSEBACK" +END_IMAGE_BUTTON_TEXT = "End" +DECELERATE_BUTTON_TEXT = "Decelerate" +ACCELERATE_BUTTON_TEXT = "Accelerate" +PAUSE_BUTTON_TEXT = "Pause" +RESUME_BUTTON_TEXT = "Resume" +RINSEBACK_TEXT = "Rinseback" +RINSEBACK_COMPLETE_TEXT = "Rinseback Complete" +END_TREATMENT_BUTTON_TEXT = "END TREATMENT" +ADDITIONAL_BUTTON_TEXT = "ADDITIONAL" +ADDITIONAL_RINSEBACK_TEXT = "Additional Rinseback" +RINSEBACK_UNIT = " mL" +RINSEBACK_UNIT_MIN = " mL/min" + + + +ALARM_ID_AND_MESSAGES = { + 1: "Stuck button POST failure.\nStop or Off button detected to be pressed for at least 1 second during test shortly after power up.", + 2: "HD FPGA POST failure.", + 3: "DG FPGA POST failure.", + 4: "HD Watchdog POST failure.", + 5: "DG Watchdog POST failure.", + 6: "UI communication POST failure.\nUI failed to communicate within a reasonable time after power up.", + 7: "Real-time clock configuration error.", + 8: "HD accelerometer failed POST.", + 9: "DG accelerometer failed POST." , + 10: "RTC or MCU timer inaccurate.", + 11: "DG heaters failed POST.", + 12: "HD firmware image integrity POST test failed.", + 13: "DG firmware image integrity POST test failed.", + 14: "HD blood flow invalid calibration.", + 15: "HD dialysate flow invalid calibration.", + 16: "HD alarm audio failed POST.", + 17: "HD UI POST failed.", + 18: "DG load cells invalid calibration record.", + 19: "DG flow sensors invalid calibration record.", + 20: "DG conductivity sensors invalid calibration record.", + 21: "DG drain line volume invalid calibration record.", + 22: "DG reservoirs invalid calibration record.", + 23: "DG acid concentrate calibration record.", + 24: "DG bicarb concentrate calibration record.", + 25: "DG accelerometer invalid calibration record.", + 26: "HD accelerometer invalid calibration record.", + 27: "HD blood flow invalid calibration record.", + 28: "HD dialyzer flow invalid calibration record.", + 29: "HD heparin force sensor invalid calibration record.", + 30: "HD Software fault.\nSoftware found itself in an unexpected state.", + 31: "Blood pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running.", + 32: "Blood pump failed motor off check.\nMeasured speed while commanded off.", + 33: "Blood pump failed motor direction check.\nMeasured vs commanded.", + 34: "Blood pump failed rotor speed check.\nMismatch with rotor and motor speeds.", + 35: "Dialysis inlet pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running.", + 36: "Dialysis inlet pump failed motor off check.\nMeasured speed while commanded off.", + 37: "Dialysis inlet pump failed motor direction check.\nMeasured vs commanded.", + 38: "Dialysis inlet pump failed rotor speed check.\nMismatch with rotor and motor speeds.", + 39: "Dialysis outlet pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running.", + 40: "Dialysis outlet pump failed motor off check.\nMeasured speed while commanded off.", + 41: "Dialysis outlet pump failed motor direction check.\nMeasured vs commanded.", + 42: "Dialysis outlet pump failed rotor speed check.\nMismatch with rotor and motor speeds.", + 43: "Watchdog expired error.\nWatchdog was not \"pet\" within the appropriate time.", + 44: "User interface communication timeout.", + 45: "Too many bad CRCs detected on received system messages.", + 46: "System message that required acknowledgment was not acknowledged.", + 47: "Ultrafiltration rate is too high error during treatment.", + 48: "Ultrafiltration volume accuracy error during treatment.", + 49: "HD FPGA communication down for too long.", + 50: "FPGA not accepting commanded valve states.", + 51: "Blood pump failed motor speed check.\nMeasured vs commanded.", + 52: "Dialysate inlet pump failed motor speed check.\nMeasured vs commanded.", + 53: "Dialysate outlet pump failed motor speed check.\nMeasured vs commanded.", + 54: "HD critical data integrity check failed.", + 55: "DG critical data integrity check failed.", + 56: "HD accelerometer error (no readings or FPGA reports error).", + 57: "DG accelerometer error (no readings or FPGA reports error).", + 58: "HD valve homing failed.", + 59: "HD valve transition time out.", + 60: "HD valve not functional.", + 61: "HD valve current out of range.", + 62: "HD valve position out of target.", + 63: "FPGA reports failure reading arterial pressure sensor.", + 64: "FPGA reports failure reading venous pressure sensor.", + 65: "HD requests DG command with invalid parameter fault.", + 66: "HD blood leak sensor set point set failure.", + 67: "HD blood pump occlusion self-test failure alarm.", + 68: "HD active reservoir recirculation out of range.", + 69: "HD blood leak sensor invalid calibration record.", + 70: "HD arterial pressure self-test failure alarm." , + 71: "HD venous pressure self-test failure alarm.", + 72: "HD blood flow meter status check self-test failure alarm.", + 73: "HD dialysate flow meter status check self-test failure alarm.", + 74: "HD blood leak detector self-test failure alarm.", + 75: "HD syringe pump self-test failure alarm.", + 76: "HD monitored voltage is out of range.", + 77: "DG monitored voltage is out of range.", + 78: "HD syringe pump direction (from encoder) error.", + 79: "HD syringe pump direction (from controller) error.", + 80: "HD syringe pump fault reported by FPGA.", + 81: "HD syringe pump over travel error.", + 82: "HD syringe pump DAC write failure.", + 83: "HD syringe pump is running while the BP is off.", + 84: "HD venous pressure sensor not being read.", + 85: "HD pump track latch opened alarm.", + 86: "HD BP occlusion sensor not being read.", + 87: "DG heating invalid calibration record.", + 88: "DG concentrate pumps hall sensor out of range.", + 89: "HD BP occlusion sensor error.", + 90: "This alarm ID is available for use.", + 91: "HD No dialysate flow data receive in the last 3 seconds.", + 92: "DG conductivity sensor bad status.", + 93: "This alarm ID is available for use.", + 94: "This alarm ID is available for use.", + 95: "This alarm ID is available for use.", + 96: "Inlet water temperature in high range.", + 97: "Fill conductivity out of range.", + 98: "HD battery communication fault.", + 99: "HD syringe pump stall alarm.", + 100: "HD no cartridge self-test timeout.", + 101: "HD dry self-test timeout.", + 102: "Real-time clock communication error.", + 103: "HD non-volatile calibration group invalid record CRC.", + 104: "Air trap level sensors reporting illegal combination of air/fluid.", + 105: "DG non-volatile system group invalid record CRC.", + 106: "DG inlet water conductivity is greater than threshold.", + 107: "HD reports DG restarted fault.", + 108: "HD syringe pump ADC error.", + 109: "HD syringe pump volume check error.", + 110: "HD syringe pump speed check error.", + 111: "HD syringe pump not stopped in off state error.", + 112: "HD blood leak detector fault.", + 113: "HD arterial air bubble detector self-test failure.", + 114: "HD venous air bubble detector self-test failure.", + 115: "DG temperature sensor out of range.", + 116: "DG temperature sensor ADC out of range.", + 117: "DG primary heater internal temperature out of range.", + 118: "DG primary heater cold junction temperature out of range.", + 119: "DG trimmer heater internal temperature out of range.", + 120: "DG trimmer heater cold junction temperature out of range.", + 121: "DG main primary heater voltage out of range.", + 122: "DG small primary heater voltage out of range.", + 123: "DG trimmer heater voltage out of range.", + 124: "HD end of treatment alarm (high priority).", + 125: "Blood sitting too long after treatment stopped by user alarm (>5 min).", + 126: "HD blood leak detected alarm.", + 127: "Venous pressure too low during treatment." , + 128: "HD venous air bubble detected alarm.", + 129: "HD venous air bubble detected rinseback alarm.", + 130: "Venous pressure too high during treatment.", + 131: "Arterial pressure too low during treatment.", + 132: "Arterial pressure too high during treatment.", + 133: "DG fluid leak detected alarm.", + 134: "HD fluid leak detected alarm." , + 135: "HD experienced large acceleration.", + 136: "DG experienced large acceleration.", + 137: "HD tilt exceeds maximum.", + 138: "DG tilt exceeds maximum.", + 139: "HD AC power lost alarm.", + 140: "Dialysate generator communication timeout.", + 141: "Air trap fill timeout during treatment.", + 142: "Blood pump occlusion detected.", + 143: "DG dialysate temperature sensors drift timeout.", + 144: "DG software configuration record invalid CRC.", + 145: "Concentrate conductivity after adding acid out of range alarm.", + 146: "Dialysate conductivity out of range.", + 147: "Wait for the DG to produce dialysate.", + 148: "Inlet water temperature too high.", + 149: "Alarm ID available for use.", + 150: "Inlet water conductivity in high range.", + 151: "Inlet water conductivity in low range.", + 152: "Inlet water pressure in low range.", + 153: "HD prime completed high priority alarm.", + 154: "EEPROM operations (read, write, erase) failure.", + 155: "DG software configuration record invalid CRC.", + 156: "HW usage data (treatment time in HD and total consumed water in DG) failure.", + 157: "DG chemical disinfect prime acid line timeout.", + 158: "Inlet water temperature is in the low range.", + 159: "Dialysate inlet pump failed flow vs motor speed check.", + 160: "Blood pump rotor speed too high.", + 161: "This alarm ID is available for use.", + 162: "This alarm ID is available for use.", + 163: "HD sees primary load cell for reservoir 1 change too much too fast.", + 164: "HD sees primary load cell for reservoir 2 change too much too fast.", + 165: "HD in treatment rinseback operation timeout.", + 166: "HD in treatment re-circ sub-mode for too long.", + 167: "HD cartridge door opened alarm.", + 168: "HD active reservoir depletion timeout.", + 169: "Dialysate flow rate out of range.", + 170: "HD syringe empty alarm.", + 171: "HD syringe pump occlusion alarm.", + 172: "HD syringe pump not enough Heparin alarm.", + 173: "HD arterial air bubble detected alarm.", + 174: "HD arterial air bubble detected rinseback alarm.", + 175: "HD pump direction status error.", + 176: "HD active reservoir is full during treatment and DG not ready to switch reservoirs.", + 177: "DG software fault.\nSoftware found itself in an unexpected state.", + 178: "HD communication timeout.", + 179: "DG FPGA communication down for too long.", + 180: "DG load cell ADC error.", + 181: "DG load cells weight out of range for tare.", + 182: "DG load cells invalid calibration.", + 183: "DG invalid load cell value.", + 184: "Inlet or Outlet UV reactor not healthy.", + 185: "DG fan RPM out of range.", + 186: "DG concentrate pump fault.", + 187: "DG concentrate pump CP1 speed control error.", + 188: "DG concentrate pump CP2 speed control error.", + 189: "DG drain pump RPM out of range.", + 190: "DG drain pump off fault.", + 191: "DG flow rate out of upper range.", + 192: "DG flow rate out of lower range.", + 193: "RO pump flow rate out of range.", + 194: "DG RO pump duty cycle out of range.", + 195: "DG RO pump pressure out of range.", + 196: "DG temperature sensor error flag fault.", + 197: "DG temperature sensors ADC fault.", + 198: "DG heaters cold junction temperature out of range.", + 199: "DG heaters fault.", + 200: "DG thermistors/sensors temperature out of range.", + 201: "Inlet water quality is bad (temperature, conductivity, pressure).", + 202: "Inlet water pressure fault.", + 203: "Pressure sensor fault.", + 204: "RO rejection ratio out of range.", + 205: "Conductivity sensor fault.", + 206: "DG dialysate fill runs out of time.", + 207: "DG flow meter check failure alarm.", + 208: "DG primary heater on with no flow time out.", + 209: "DG drain circulation line timeout.", + 210: "HD battery pack detected an error.", + 211: "Blood sitting too long warning (>4 min).", + 212: "HD end of treatment alarm (user not acting to end treatment).", + 213: "HD prime completed medium priority alarm.", + 214: "HD Saline bolus volume check failure.", + 215: "HD rinseback volume check failure.", + 216: "HD end treatment sub-mode timeout alarm.", + 217: "HD blood prime volume check failure.", + 218: "HD syringe detected alarm.", + 219: "HD syringe pump syringe removed alarm.", + 220: "HD battery pack SOC is too low.", + 221: "HD Saline bag is empty.", + 222: "HD dialysate temperature too high alarm.", + 223: "HD dialysate temperature too low alarm.", + 224: "Treatment stopped by user action.", + 225: "HD end of treatment warning.", + 226: "HD prime completed low priority alarm.", + 227: "HD prime out of time alarm.", + 228: "HD time out on prime sub-mode purge air state.", + 229: "HD prime dialysate dialyzer time out alarm.", + 230: "HD prime dialysate bypass time out alarm.", + 231: "HD pre-treatment mode dry self-tests failure.", + 232: "HD pre-treatment mode wet self-tests failure.", + 233: "RTC battery low.", + 234: "RTC (i.e read time) or RAM operations failure (read or write).", + 235: "HD in treatment stopped sub-mode after rinseback completed (no escalation).", + 236: "HD needs new cartridge to be installed.", + 237: "HD prime saline dialyzer time out alarm.", + 238: "HD no cartridge loaded or installed improperly alarm.", + 239: "HD fail to remove cartridge alarm.", + 240: "Bicarb conductivity out of range during bicarb pump check alarm.", + 241: "DG reservoir drain time out.", + 242: "DG reservoir fill time out.", + 243: "DG reservoir leak time out.", + 244: "DG temperature sensors difference out of range.", + 245: "DG heat disinfect target temperature time out (could not reach to temperature).", + 246: "DG heat disinfect inlet pressure and temperature sensors out of range.", + 247: "DG heat disinfect inlet conductivity and temperature out of range.", + 248: "DG chemical disinfect could not reach to target temperature.", + 249: "DG chemical disinfect inlet pressure and temperature sensors out of range.", + 250: "DG chemical disinfect inlet conductivity and temperature out of range.", + 251: "HD invalid system record.", + 252: "HD invalid service record.", + 253: "DG invalid system record.", + 254: "DG invalid service record.", + 255: "HD and UI software builds are not compatible.", + 256: "HD and DG software builds are not compatible.", + 257: "DG FPGA power out timeout.", + 258: "HD FPGA power out timeout.", + 259: "HD temperatures out of range.", + 260: "UI POST Application Integrity (Sha256Sum) failure.", + 261: "UI POST CANBus failure.", + 262: "UI POST Display failure.", + 263: "UI POST Touch failure.", + 264: "UI POST SD-Card failure.", + 265: "UI POST RTC failure.", + 266: "UI POST WiFi failure.", + 267: "UI POST Bluetooth failure.", + 268: "UI POST Ethernet failure.", + 269: "UI POST Sound failure.", + 270: "HD POST Safety Shutdown failure.", + 271: "DG POST Safety Shutdown failure.", + 272: "HD Fan RPM out of range.", + 273: "HD measured blood pump flow rate is out of range.", + 274: "HD measured dialysate inlet pump flow rate is out of range.", + 275: "HD arterial pressure sensor is reading out of range.", + 276: "HD venous pressure sensor is reading out of range.", + 277: "HD BP occlusion sensor is reading out of range.", + 278: "HD active reservoir weight out of range.", + 279: "DG dialysate drain time out.", + 280: "HD arterial pressure sensor read timeout error.", + 281: "Acid concentration bottle low volume alarm.", + 282: "Bicarbonate concentration bottle low volume alarm.", + 283: "DG load cells weight out of range.", + 284: "DG load cells primary/back up drift out of range.", + 285: "HD treatment recirculate timeout warning.", + 286: "HD treatment rinseback complete timeout warning.", + 287: "HD processor clock speed checks against FPGA clock failure.", + 288: "DG trimmer heater on with flow timeout.", + 289: "DG dialysate or concentrate caps not closed." + } + +ALARM_PRIORITIES = {1: "LOW", 2: "MEDIUM", 3: "HIGH"} +ALARM_LIST_TITLE = "Alarm list" +UNDEFINED_ALARM_ID_MSG = "ALARM_ID_UNDEFINED" +ALARM_TITLE = "Alarm" + +ALARM_PRIORITY_OPTIONS = { + 0 : 'ALARM_PRIORITY_NONE' , + 1 : 'ALARM_PRIORITY_LOW' , + 2 : 'ALARM_PRIORITY_MEDIUM', + 3 : 'ALARM_PRIORITY_HIGH', +} + +ULTRAFILTRATION_PAUSED_TEXT = "Ultrafiltration Paused" +RESUME_TEXT = "RESUME ULTRAFILTRATION" +EDIT_TEXT = "EDIT ULTRAFILTRATION VOLUME" +TITLE_TEXT = "ULTRAFILTRATION VOLUME (L)" + +PRESSURE_TITLE = "PRESSURES" +ARTERIAL_TITLE = "Arterial" +VENOUS_TITLE = "Venous" +VENOUS_UOM = "mmHg" +ARTERIAL_UOM = "mmHg" +LOW_TEXT = "LOW" +HIGH_TEXT = "HIGH" + +FLOW_UNIT = "mL/min" +BLOOD_FLOW_TEXT = "blood" +DIALYSATE_FLOW_TEXT = "dialysate" + +VITALS_TITLE = "VITALS" +HEART_RATE_TITLE = "Heart Rate" +BLOOD_PRESSURE_TITLE = "Blood Pressure" +BLOOD_PRESSURE_UNIT = "mmHg" +HEART_RATE_UNIT = "BPM" + HEPARIN_TEXT = "HEPARIN" VOLUME_DELIVERED = "Volume Delivered" @@ -225,5 +1021,3 @@ PASS_TEXT = "PASS" FAIL_TEXT = "FAIL" OK_TEXT = "OK" - - \ No newline at end of file Index: shared/scripts/configuration/utility.py =================================================================== diff -u -rdd182e384d5248240f343cc4855ff292ba5e4ee3 -r6052b7abfc1d50f6c952a4e12a9bc86c2c5f6e04 --- shared/scripts/configuration/utility.py (.../utility.py) (revision dd182e384d5248240f343cc4855ff292ba5e4ee3) +++ shared/scripts/configuration/utility.py (.../utility.py) (revision 6052b7abfc1d50f6c952a4e12a9bc86c2c5f6e04) @@ -101,7 +101,6 @@ return False - def pressure_pop_up_text_obj(text): names.o_pop_up_pressure_text_obj["text"] = text return names.o_pop_up_pressure_text_obj @@ -156,12 +155,14 @@ test.passes("object is not present as expected") squish.testSettings.objectNotFoundDebugging = True +def pressure_pop_up_text_obj(text): + names.o_pop_up_pressure_text_obj["text"] = text + return names.o_pop_up_pressure_text_obj def pressure_text_obj(text): names.o_pressure_text_obj["text"] = text return names.o_pressure_text_obj - def get_current_date_and_time(date_format='%Y/%b/%d - %H:%M'): date = datetime.now() return str(date.strftime(date_format)) @@ -200,7 +201,6 @@ raise LookupError("zone object is not in view to the user after trying 100 times") - def get_current_date_and_time(date_format='%Y/%b/%d - %H:%M'): date = datetime.now() @@ -232,6 +232,43 @@ test.compare(str(input_field.text), "", "Input field should be empty") test.endSection() +def vitals_reading_obj(reading): + names.o_vitals_reading["text"] = reading + return names.o_vitals_reading + +def keypad_input(key_value): + names.o_keypad_input["text"] = key_value + return names.o_keypad_input + + +def scroll_to_zone(zone=None, screen_object=None, direction = None): + """ + scroll to the to the value if object is hidden + @param value - (obj) value object + @param container - (obj) Container of the value + @return boolean true and false + """ + counter = 0 + while counter <= 100: + try: + counter += 1 + squish.findObject(zone) + squish.snooze(0.5) + if check_if_object_is_within_the_container(obj=zone, container=screen_object): + return True + else: + raise RuntimeError + except RuntimeError: + ScreenObj = squish.findObject(screen_object) + screenHeight = pyInt(ScreenObj.height) + screenWidth = pyInt(ScreenObj.width) + if direction is None: + squish.mouseWheel(ScreenObj, (screenWidth-100), 107, 0, -(screenHeight-460), squish.Qt.NoModifier) + else: + squish.mouseWheel(ScreenObj, (screenWidth-100), -(screenHeight-700), 0, 200, squish.Qt.NoModifier) + + raise LookupError("zone object is not in view to the user after trying 100 times") + def get_alarm_id_obj(id): names.o_alarm_id["text"] = id return names.o_alarm_id @@ -369,7 +406,7 @@ continue # arterial blood pressure low limit should be lower than the high limit by at least 30mmHg if arterial_max == arterial_min + config.BUFFER_LOW_AND_HIGH_LIMITS: - test.compare(high_handler_parent.maxValue, arterial_max, "Arterial range maximum value cannot be moved beyond {}".format(arterial_max)) + test.compare(high_handler_parent.maxValue, arterial_max, "Arterial range maximum value cannot be moved beyond {}".format(arterial_max)) else: test.compare(arterial_max, art_high, "Actual Arterial range maximum value: {} is equal to Expected value: {}".format(arterial_max, art_high)) test.endSection() @@ -466,30 +503,6 @@ test.compare(ven_min, ven_low, "Actual Venous range minimum value: {} is equal to Expected value: {}".format(ven_min, ven_low)) test.endSection() -def scroll_to_value_on_pop_up(value=None, container=None): - """ - scroll to the to the value if object is hidden - @param value - (obj) value object - @param container - (obj) Container of the value - @return boolean true and false - """ - counter = 0 - while counter <= 100: - try: - counter += 1 - squish.findObject(value) - squish.snooze(0.5) - if check_if_object_is_within_the_container(obj=value, container=container): - return True - else: - raise RuntimeError - except RuntimeError: - ScreenObj = squish.waitForObject(container) - screenHeight = pyInt(ScreenObj.height) - screenWidth = pyInt(ScreenObj.width) - squish.mouseWheel(ScreenObj, screenWidth//2, screenHeight//2, 0, -50, squish.Qt.NoModifier) - raise LookupError("value object is not in view to the user after trying 100 times") - def expected_heparin_value(val): names.o_heparin_value["text"] = val return names.o_heparin_value @@ -583,8 +596,159 @@ expected_progress = time_out - count_down test.compare(current_progress, expected_progress, "{} should be the current progress".format(expected_progress)) test.endSection() - +def verify_page_step_indicator(screen_obj, treatment_step, treatment_screens): + """ + Method to verify the Page Step indicators [the object on top of the screen which indicates the steps passed, current, remained] + @param treatment_step : (int) indicates the Current treatment step + """ + test.startSection("verification of page step indicators") + for page in range(len(treatment_screens)): + bullet_children = object.children(squish.waitForObjectExists(get_bullet_object(screen_obj, page))) + bullet_circle_color = bullet_children[0].color.name + bullet_border_color = bullet_children[0].border.color.name + step_title = squish.waitForObjectExists(get_text_object(screen_obj, treatment_screens[page])) + #To verify the step indicators of the completed treatment screens + if page < treatment_step: + test.verify(squish.waitForObjectExists(get_bullet_object(screen_obj, page)).complete) + test.verify(not squish.waitForObjectExists(get_bullet_object(screen_obj, page)).current) + test.compare(bullet_circle_color, config.COMPLETE_COLOR) + test.compare(bullet_border_color, config.COMPLETE_COLOR) + test.compare(step_title.color.name, config.ENABLED_COLOR) + #To verify the step indicators of the current treatment screen + elif page == treatment_step: + test.verify(squish.waitForObjectExists(get_bullet_object(screen_obj, page)).current,) + test.verify(not squish.waitForObjectExists(get_bullet_object(screen_obj, page)).complete) + test.compare(bullet_circle_color, config.CURRENT_COLOR) + test.compare(bullet_border_color, config.COMPLETE_COLOR) + test.compare(step_title.color.name, config.ENABLED_COLOR) + test.verify(step_title.font.bold) + #To verify the step indicators of the remaining treatment screens + else: + test.verify(not squish.waitForObjectExists(get_bullet_object(screen_obj, page)).current,) + test.verify(not squish.waitForObjectExists(get_bullet_object(screen_obj, page)).complete,) + test.compare(step_title.color.name, config.INCOMPLETE_COLOR) + test.compare(bullet_circle_color, config.CURRENT_COLOR) + test.compare(bullet_border_color, config.INCOMPLETE_COLOR) + test.endSection() + +def verify_missing_object(object_to_check): + """ + Method to verify the given object is invisible or is not present on the screen + @param object_to_check: the object whose invisibility must be verified + """ + try: + squish.testSettings.objectNotFoundDebugging = False + squish.waitForObject(object_to_check,3000) + test.fail("Given object should not be present initially") + except LookupError as _: + test.passes("object is not present as expected") + + squish.testSettings.objectNotFoundDebugging = True + +def set_arterial_ranges_min_val(art_low): + """ + Method to set the Arterial range maximum value to user expected value + @param art_low - (int) user expected value + """ + test.startSection("Set Arterial range minimum value to {}".format(art_low)) + arterial_min = squish.waitForObjectExists(names.o_PreTreatmentCreate_rangeRect_RangeRect_Artery) + arterial_min = pyInt(arterial_min.minimum) + arterial_max = squish.waitForObjectExists(names.o_PreTreatmentCreate_rangeRect_RangeRect_Artery) + arterial_max = pyInt(arterial_max.maximum) + low_handler_parent = object.parent(squish.waitForObjectExists(names.o_PreTreatmentCreate_rangeRect_RangeRect_Artery)) + low_handler_children = object.children(low_handler_parent) + low_handler = low_handler_children[-2] + width = pyInt(low_handler.width) - 8 + height = pyInt(low_handler.height)- 10 + if arterial_min == art_low: + test.passes("Arterial range minimum is already set to {}".format(art_low)) + elif arterial_min < art_low: + while arterial_min != art_low: + squish.mouseDrag(low_handler, width, height, 1, 0, squish.Qt.NoModifier, squish.Qt.LeftButton) + arterial_min += 10 + # arterial blood pressure low limit should be lower than the high limit by at least 30mmHg + if arterial_min == arterial_max - config.BUFFER_LOW_AND_HIGH_LIMITS: + squish.mouseDrag(low_handler, width, height, 1, 0, squish.Qt.NoModifier, squish.Qt.LeftButton) + test.log("Arterial range minimum value cannot be moved beyond {}".format(arterial_min)) + break + else: + continue + elif arterial_min > art_low: + while arterial_min != art_low: + squish.mouseDrag(low_handler, width, height, -1, 0, squish.Qt.NoModifier, squish.Qt.LeftButton) + arterial_min -= 10 + # arterial blood pressure low limit should be lower than the high limit by at least 30mmHg + if arterial_min == arterial_max - config.BUFFER_LOW_AND_HIGH_LIMITS: + squish.mouseDrag(low_handler, width, height, -1, 0, squish.Qt.NoModifier, squish.Qt.LeftButton) + test.log("Arterial range minimum value cannot be moved beyond {}".format(arterial_min)) + break + else: + continue + # arterial blood pressure low limit should be lower than the high limit by atleast 30mmHg + if arterial_min == arterial_max - config.BUFFER_LOW_AND_HIGH_LIMITS: + test.compare(low_handler_parent.minValue, arterial_min, "Arterial range minimum value cannot be moved beyond {}".format(arterial_min)) + else: + test.compare(arterial_min, art_low, "Actual Arterial range minimum value: {} is equal to Expected value: {}".format(arterial_min, art_low)) + test.endSection() + + +def set_arterial_ranges_max_val(art_high): + """ + Method to set the Arterial range maximum value to user expected value + @param art_high - (int) user expected value + """ + test.startSection("Set Arterial range maximum value to {}".format(art_high)) + arterial_max = squish.waitForObjectExists(names.o_PreTreatmentCreate_rangeRect_RangeRect_Artery) + arterial_max = pyInt(arterial_max.maximum) + arterial_min = squish.waitForObjectExists(names.o_PreTreatmentCreate_rangeRect_RangeRect_Artery) + arterial_min = pyInt(arterial_min.minimum) + high_handler_parent = object.parent(squish.waitForObjectExists(names.o_PreTreatmentCreate_rangeRect_RangeRect_Artery)) + high_handler_children = object.children(high_handler_parent) + high_handler = high_handler_children[-1] + width = pyInt(high_handler.width) - 20 + height = pyInt(high_handler.height) - 25 + if arterial_max == art_high: + test.passes("Arterial range maximum is already set to {}".format(art_high)) + elif arterial_max < art_high: + while arterial_max != art_high: + squish.mouseDrag(high_handler, -1, height, width, 0, squish.Qt.NoModifier, squish.Qt.LeftButton) + arterial_max += 10 + # arterial blood pressure low limit should be lower than the high limit by at least 30mmHg + if arterial_max == arterial_min + config.BUFFER_LOW_AND_HIGH_LIMITS: + squish.mouseDrag(high_handler, width, height, 1, 0, squish.Qt.NoModifier, squish.Qt.LeftButton) + test.log("Arterial range maximum value cannot be moved beyond {}".format(arterial_max)) + break + else: + continue + elif arterial_max > art_high: + while arterial_max != art_high: + squish.mouseDrag(high_handler, width, height, -1, 0, squish.Qt.NoModifier, squish.Qt.LeftButton) + arterial_max -= 10 + # arterial blood pressure low limit should be lower than the high limit by at least 30mmHg + if arterial_max == arterial_min + config.BUFFER_LOW_AND_HIGH_LIMITS: + squish.mouseDrag(high_handler, width, height, -1, 0, squish.Qt.NoModifier, squish.Qt.LeftButton) + test.log("Arterial range maximum value cannot be moved beyond {}".format(arterial_max)) + break + else: + continue + # arterial blood pressure low limit should be lower than the high limit by at least 30mmHg + if arterial_max == arterial_min + config.BUFFER_LOW_AND_HIGH_LIMITS: + test.compare(high_handler_parent.maxValue, arterial_max, "Arterial range maximum value cannot be moved beyond {}".format(arterial_max)) + else: + test.compare(arterial_max, art_high, "Actual Arterial range maximum value: {} is equal to Expected value: {}".format(arterial_max, art_high)) + test.endSection() + +def get_text_object(screen_obj, txt): + """ + To obtain a text object based on text provided + @param screen_obj: provides the container on which the txt must be present + @returns a real name object + """ + names.o_text_object["container"] = screen_obj + names.o_text_object["text"] = txt + return names.o_text_object + def verify_color_of_entry(entry, vital_parameter, input_field): """ Method to verify the color of entry