Index: shared/scripts/configuration/config.py =================================================================== diff -u -rabbb06cfcc9001b2e1ceb0a9c964e0c219754d69 -reb47b728e03c07a2ecb47a858983bfbbc9ad657e --- shared/scripts/configuration/config.py (.../config.py) (revision abbb06cfcc9001b2e1ceb0a9c964e0c219754d69) +++ shared/scripts/configuration/config.py (.../config.py) (revision eb47b728e03c07a2ecb47a858983bfbbc9ad657e) @@ -17,8 +17,13 @@ from pathlib import Path from configuration.strings import * -AUT_NAME = "denaliSquish" +# -S, --disable-sd-card-fail-log-stop disable-sd-card-fail-log-stop +# -k, --enable-check-in-log Enables Check-In Log +# -K, --enable-acknow-log Enables Acknowledgment Log +AUT_NAME = "denaliSquish -k -K -S" + + COMMON_PATH = os.environ['HOME']+"/Projects" COLOR_CODES = {"Aqua": "#81ffff", "Blue": "#017dea", "Blue 2": "#1090d5", "Green": "#29fd2d", "Grey": "#d3d3d3", Index: shared/scripts/configuration/strings.py =================================================================== diff -u -rabbb06cfcc9001b2e1ceb0a9c964e0c219754d69 -reb47b728e03c07a2ecb47a858983bfbbc9ad657e --- shared/scripts/configuration/strings.py (.../strings.py) (revision abbb06cfcc9001b2e1ceb0a9c964e0c219754d69) +++ shared/scripts/configuration/strings.py (.../strings.py) (revision eb47b728e03c07a2ecb47a858983bfbbc9ad657e) @@ -14,6 +14,302 @@ ############################################################################ +ALARM_ID_AND_MESSAGES = { + 0: "Indication for when no alarms is a possible situation", + 1: "Stuck button POST failure.\nStop or Off button detected to be pressed for at least 1 second during test shortly after power up", + 2: "HD FPGA POST failure.", + 3: "DG FPGA POST failure.", + 4: "HD Watchdog POST failure.", + 5: "DG Watchdog POST failure.", + 6: "UI communication POST failure.\nUI failed to communicate within a reasonable time after power up.", + 7: "HD RTC battery low.", + 8: "HD accelerometer failed POST.", + 9: "DG accelerometer failed POST." , + 10: "Alarm ID available for use.", + 11: "Alarm ID available for use.", + 12: "HD firmware image integrity POST test failed.", + 13: "DG firmware image integrity POST test failed.", + 14: "HD blood flow invalid calibration.", + 15: "HD dialysate flow invalid calibration.", + 16: "HD alarm audio failed POST.", + 17: "HD UI POST failed.", + 18: "DG load cells invalid calibration record.", + 19: "DG flow sensors invalid calibration record.", + 20: "DG conductivity sensors invalid calibration record.", + 21: "DG drain line volume invalid calibration record.", + 22: "DG reservoirs invalid calibration record.", + 23: "DG acid concentrate calibration record.", + 24: "DG bicarb concentrate calibration record.", + 25: "DG accelerometer invalid calibration record.", + 26: "HD accelerometer invalid calibration record.", + 27: "HD blood flow invalid calibration record.", + 28: "HD dialyzer flow invalid calibration record.", + 29: "HD heparin force sensor invalid calibration record.", + 30: "HD Software fault.\nSoftware found itself in an unexpected state.", + 31: "Blood pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running.", + 32: "Blood pump failed motor off check.\nMeasured speed while commanded off.", + 33: "Blood pump failed motor direction check.\nMeasured vs commanded.", + 34: "Blood pump failed rotor speed check.\nMismatch with rotor and motor speeds.", + 35: "Dialysis inlet pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running.", + 36: "Dialysis inlet pump failed motor off check.\nMeasured speed while commanded off.", + 37: "Dialysis inlet pump failed motor direction check.\nMeasured vs commanded.", + 38: "Dialysis inlet pump failed rotor speed check.\nMismatch with rotor and motor speeds.", + 39: "Dialysis outlet pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running.", + 40: "Dialysis outlet pump failed motor off check.\nMeasured speed while commanded off.", + 41: "Dialysis outlet pump failed motor direction check.\nMeasured vs commanded.", + 42: "Dialysis outlet pump failed rotor speed check.\nMismatch with rotor and motor speeds.", + 43: "HD blood leak self test fault.", + 44: "User interface communication timeout.", + 45: "HD too many bad communications CRC.", + 46: "System message that required acknowledgment was not acknowledged.", + 47: "Ultrafiltration rate is too high error during treatment.", + 48: "Ultrafiltration volume accuracy error during treatment.", + 49: "HD FPGA communication down for too long.", + 50: "FPGA not accepting commanded valve states.", + 51: "Blood pump failed motor speed check.\nMeasured vs commanded.", + 52: "Dialysate inlet pump failed motor speed check.\nMeasured vs commanded.", + 53: "Dialysate outlet pump failed motor speed check.\nMeasured vs commanded.", + 54: "HD critical data integrity check failed.", + 55: "DG critical data integrity check failed.", + 56: "HD accelerometer error (no readings or FPGA reports error).", + 57: "DG accelerometer error (no readings or FPGA reports error).", + 58: "HD valve homing failed.", + 59: "HD valve transition time out.", + 60: "HD valve not functional.", + 61: "HD valve current out of range.", + 62: "HD valve position out of target.", + 63: "FPGA reports failure reading arterial pressure sensor.", + 64: "FPGA reports failure reading venous pressure sensor.", + 65: "HD requests DG command with invalid parameter fault.", + 66: "HD blood leak sensor set point set failure.", + 67: "HD blood pump occlusion self-test failure alarm.", + 68: "HD active reservoir recirculation out of range.", + 69: "HD blood leak sensor invalid calibration record.", + 70: "HD arterial pressure self-test failure alarm." , + 71: "HD venous pressure self-test failure alarm.", + 72: "HD blood flow meter status check self-test failure alarm.", + 73: "HD dialysate flow meter status check self-test failure alarm.", + 74: "HD blood leak detector self-test transmit timeout.", + 75: "HD syringe pump self-test failure alarm.", + 76: "HD monitored voltage is out of range.", + 77: "DG monitored voltage is out of range.", + 78: "HD syringe pump direction (from encoder) error.", + 79: "HD syringe pump direction (from controller) error.", + 80: "HD syringe pump fault reported by FPGA.", + 81: "HD syringe pump over travel error.", + 82: "HD syringe pump DAC write failure.", + 83: "HD syringe pump is running while the BP is off.", + 84: "HD venous pressure sensor not being read.", + 85: "HD pump track latch opened alarm.", + 86: "HD BP occlusion sensor not being read.", + 87: "DG heating invalid calibration record.", + 88: "DG concentrate pumps hall sensor out of range.", + 89: "HD BP occlusion sensor error.", + 90: "DG load cells FPGA read error.", + 91: "HD No dialysate flow data receive in the last 3 seconds.", + 92: "DG conductivity sensor bad status.", + 93: "DG outlet primary conductivity out of range.", + 94: "DG pressure out of range.", + 95: "DG watchdog expired.", + 96: "Inlet water temperature in high range.", + 97: "Fill conductivity out of range.", + 98: "HD battery communication fault.", + 99: "HD syringe pump stall alarm.", + 100: "HD no cartridge self-test timeout.", + 101: "HD dry self-test timeout.", + 102: "DG heat disinfect temperature gradient out of range.", + 103: "HD non-volatile calibration group invalid record CRC.", + 104: "Air trap level sensors reporting illegal combination of air/fluid.", + 105: "DG non-volatile system group invalid record CRC.", + 106: "Unused.", + 107: "HD reports DG restarted fault.", + 108: "HD syringe pump ADC error.", + 109: "HD syringe pump volume check error.", + 110: "HD syringe pump speed check error.", + 111: "HD syringe pump not stopped in off state error.", + 112: "HD blood leak zero command transmit timeout.", + 113: "HD blood leak zero command fault.", + 114: "HD venous air bubble detector self-test failure.", + 115: "DG temperature sensor out of range.", + 116: "DG temperature sensor ADC fault.", + 117: "DG CAN message not acked.", + 118: "DG RTC config error.", + 119: "DG RTC battery low error.", + 120: "HD pre-treatment mode wet self-test prime check failure.", + 121: "DG main primary heater voltage out of range.", + 122: "DG small primary heater voltage out of range.", + 123: "DG trimmer heater voltage out of range.", + 124: "HD end of treatment alarm (high priority).", + 125: "Blood sitting too long after treatment stopped by user alarm (>5 min).", + 126: "HD blood leak detected alarm.", + 127: "Venous pressure too low during treatment." , + 128: "HD venous air bubble detected alarm.", + 129: "HD venous air bubble detected rinseback alarm.", + 130: "Venous pressure too high during treatment.", + 131: "Arterial pressure too low during treatment.", + 132: "Arterial pressure too high during treatment.", + 133: "DG fluid leak detected alarm.", + 134: "HD fluid leak detected alarm." , + 135: "HD experienced large acceleration.", + 136: "DG experienced large acceleration.", + 137: "HD tilt exceeds maximum.", + 138: "DG tilt exceeds maximum.", + 139: "HD AC power lost alarm.", + 140: "Dialysate generator communication timeout.", + 141: "Air trap fill timeout during treatment.", + 142: "Blood pump occlusion detected.", + 143: "DG dialysate temperature sensors out of range.", + 144: "Alarm ID available for use.", + 145: "Concentrate conductivity after adding acid out of range alarm.", + 146: "DG RTC or timer accuracy failure.", + 147: "Wait for the DG to produce dialysate.", + 148: "Inlet water temperature too high.", + 149: "HD watchdog expired.", + 150: "Inlet water conductivity in high range.", + 151: "Inlet water conductivity in low range.", + 152: "Inlet water pressure in low range.", + 153: "HD prime completed high priority alarm.", + 154: "EEPROM operations (read, write, erase) failure.", + 155: "Alarm ID available for use.", + 156: "Alarm ID available for use.", + 157: "DG chemical disinfect prime acid line timeout.", + 158: "Inlet water temperature is in the low range.", + 159: "Dialysate inlet pump failed flow vs motor speed check.", + 160: "Blood pump rotor speed too high.", + 161: "DG comm too many bad CRCs.", + 162: "DG FPGA clock speed check failure.", + 163: "HD sees primary load cell for reservoir 1 change too much too fast.", + 164: "HD sees primary load cell for reservoir 2 change too much too fast.", + 165: "HD in treatment rinseback operation timeout.", + 166: "HD in treatment re-circ sub-mode for too long.", + 167: "HD cartridge door opened alarm.", + 168: "HD active reservoir depletion timeout.", + 169: "Dialysate flow rate out of range.", + 170: "HD syringe empty alarm.", + 171: "HD syringe pump occlusion alarm.", + 172: "HD syringe pump not enough Heparin alarm.", + 173: "HD RTC configuration error.", + 174: "HD RTC or timer accuracy failure.", + 175: "HD pump direction status error.", + 176: "HD active reservoir is full during treatment and DG not ready to switch reservoirs.", + 177: "DG software fault.\nSoftware found itself in an unexpected state.", + 178: "HD communication timeout.", + 179: "DG FPGA communication down for too long.", + 180: "DG load cell ADC error.", + 181: "DG load cells weight out of range for tare.", + 182: "DG load cells invalid calibration.", + 183: "DG invalid load cell value.", + 184: "Inlet or Outlet UV reactor not healthy.", + 185: "DG fan RPM out of range.", + 186: "DG concentrate pump fault.", + 187: "DG concentrate pump CP1 speed control error.", + 188: "DG concentrate pump CP2 speed control error.", + 189: "DG drain pump RPM out of range.", + 190: "DG drain pump off fault.", + 191: "DG flow rate out of upper range.", + 192: "DG flow rate out of lower range.", + 193: "Alarm available for use.", + 194: "DG RO pump duty cycle out of range.", + 195: "DG RO pump pressure out of range.", + 196: "DG temperature sensor error bit fault.", + 197: "DG temperature sensors FPGA fault.", + 198: "RO flow too low while primary heater is on.", + 199: "Dialysate flow too low while trimmer heater is on.", + 200: "DG thermistors/sensors temperature out of range.", + 201: "HD pre-treatment mode wet self-test lc vs FMD failure.", + 202: "HD pre-treatment mode dry pressure normal self-test failure.", + 203: "Pressure sensor fault.", + 204: "RO rejection ratio out of range.", + 205: "Conductivity sensor fault.", + 206: "DG dialysate fill runs out of time.", + 207: "DG flow meter check failure alarm.", + 208: "HD venous pressure occlusion alarm.", + 209: "DG drain circulation line timeout.", + 210: "HD battery pack detected an error.", + 211: "Blood sitting too long warning (>4 min).", + 212: "HD end of treatment alarm (user not acting to end treatment).", + 213: "HD prime completed medium priority alarm.", + 214: "HD Saline bolus volume check failure.", + 215: "HD rinseback volume check failure.", + 216: "HD end treatment sub-mode timeout alarm.", + 217: "HD blood prime volume check failure.", + 218: "HD syringe detected alarm.", + 219: "HD syringe pump syringe removed alarm.", + 220: "HD battery pack SOC is too low.", + 221: "HD Saline bag is empty.", + 222: "HD dialysate temperature too high alarm.", + 223: "HD dialysate temperature too low alarm.", + 224: "Treatment stopped by user action.", + 225: "HD end of treatment warning.", + 226: "HD prime completed low priority alarm.", + 227: "HD prime out of time alarm.", + 228: "HD time out on prime sub-mode purge air state.", + 229: "HD prime dialysate dialyzer time out alarm.", + 230: "HD prime dialysate bypass time out alarm.", + 231: "HD pre-treatment mode dry pressure self-test failure.", + 232: "HD pre-treatment mode wet self-test LC vs LC failure.", + 233: "Alarm ID available for use.", + 234: "RTC (i.e read time) or RAM operations failure (read or write).", + 235: "HD in treatment stopped sub-mode after rinseback completed (no escalation).", + 236: "HD needs new cartridge to be installed.", + 237: "HD prime saline dialyzer time out alarm.", + 238: "HD no cartridge loaded or installed improperly alarm.", + 239: "HD fail to remove cartridge alarm.", + 240: "Bicarb conductivity out of range during bicarb pump check alarm.", + 241: "DG reservoir drain time out.", + 242: "DG reservoir fill time out.", + 243: "DG reservoir leak time out.", + 244: "DG temperature sensors difference out of range.", + 245: "DG heat disinfect target temperature time out (could not reach to temperature).", + 246: "DG heat disinfect inlet pressure and temperature sensors out of range.", + 247: "DG heat disinfect inlet conductivity and temperature out of range.", + 248: "DG chemical disinfect could not reach to target temperature.", + 249: "DG chemical disinfect inlet pressure and temperature sensors out of range.", + 250: "DG chemical disinfect inlet conductivity and temperature out of range.", + 251: "HD invalid system record.", + 252: "HD invalid service record.", + 253: "DG invalid system record.", + 254: "DG invalid service record.", + 255: "HD and UI software builds are not compatible.", + 256: "HD and DG software builds are not compatible.", + 257: "DG FPGA power out timeout.", + 258: "HD FPGA power out timeout.", + 259: "HD temperatures out of range.", + 260: "UI POST Application Integrity (Sha256Sum) failure.", + 261: "UI POST CANBus failure.", + 262: "UI POST Display failure.", + 263: "UI POST Touch failure.", + 264: "UI POST SD-Card failure.", + 265: "UI POST RTC failure.", + 266: "UI POST WiFi failure.", + 267: "UI POST Bluetooth failure.", + 268: "UI POST Ethernet failure.", + 269: "UI POST Sound failure.", + 270: "HD POST Safety Shutdown failure.", + 271: "DG POST Safety Shutdown failure.", + 272: "HD Fan RPM out of range.", + 273: "HD measured blood pump flow rate is out of range.", + 274: "HD measured dialysate inlet pump flow rate is out of range.", + 275: "HD arterial pressure sensor is reading out of range.", + 276: "HD venous pressure sensor is reading out of range.", + 277: "HD BP occlusion sensor is reading out of range.", + 278: "HD active reservoir weight out of range.", + 279: "DG dialysate drain time out.", + 280: "HD arterial pressure sensor read timeout error.", + 281: "Acid concentration bottle low volume alarm.", + 282: "Bicarbonate concentration bottle low volume alarm.", + 283: "DG load cells weight out of range.", + 284: "DG load cells primary/back up drift out of range.", + 285: "HD treatment recirculate timeout warning.", + 286: "HD treatment rinseback complete timeout warning.", + 287: "HD processor clock speed checks against FPGA clock failure.", + 288: "HD load cells primary/back up drift out of range.", + 289: "DG dialysate or concentrate caps not closed.", + 290: "DG flow too low while heater is on.", + 291: "Total number of alarms." #Issue 77 - need to remove after issue fix + } + + ALARM_ID_AND_ALARM_MESSAGES = { 0: "Indication for when no alarms is a possible situation", 1: "Call service to schedule a repair.", @@ -25,12 +321,12 @@ 7: "Call service to schedule a repair.", 8: "Call service to schedule a repair.", 9: "Call service to schedule a repair." , - 10: "Call service to schedule a repair.", - 11: "Alarm ID available for use.", + 10: "Not used.", + 11: "HD dialysate temperature below target temperature.", 12: "Call service to schedule a repair.", 13: "Call service to schedule a repair.", - 14: "HD blood flow invalid calibration.", - 15: "HD dialysate flow invalid calibration.", + 14: "DG invalid usage record CRC.", + 15: "HD invalid usage record CRC.", 16: "Call service to schedule a repair.", 17: "Call service to schedule a repair.", 18: "Call service to schedule a repair.", @@ -42,8 +338,8 @@ 24: "Call service to schedule a repair.", 25: "Call service to schedule a repair.", 26: "Call service to schedule a repair.", - 27: "HD blood flow invalid calibration record.", - 28: "HD dialyzer flow invalid calibration record.", + 27: "Not used.", + 28: "Not used.", 29: "Call service to schedule a repair.", 30: "Call service to schedule a repair.", 31: "Call service to schedule a repair.", @@ -81,14 +377,14 @@ 63: "Call service to schedule a repair.", 64: "Call service to schedule a repair.", 65: "Call service to schedule a repair.", - 66: "HD blood leak sensor set point set failure.", + 66: "Call service to schedule a repair.", 67: "Call service to schedule a repair.", 68: "Dialysate has recirculated for too long.", - 69: "HD blood leak sensor invalid calibration record.", + 69: "Call service to schedule a repair.", 70: "Call service to schedule a repair." , 71: "Call service to schedule a repair.", - 72: "HD blood flow meter status check self-test failure alarm.", - 73: "HD dialysate flow meter status check self-test failure alarm.", + 72: "Not used.", + 73: "Not used.", 74: "Call service to schedule a repair.", 75: "Call service to schedule a repair.", 76: "Call service to schedule a repair.", @@ -100,7 +396,7 @@ 82: "Call service to schedule a repair.", 83: "Call service to schedule a repair.", 84: "Call service to schedule a repair.", - 85: "Call service to schedule a repair.", + 85: "Open front door and pull pump track lever all the way down.", 86: "Call service to schedule a repair.", 87: "DG heating invalid calibration record.", 88: "DG concentrate pumps hall sensor out of range.", @@ -117,7 +413,7 @@ 99: "Call service to schedule a repair.", 100: "Call service to schedule a repair.", 101: "Call service to schedule a repair.", - 102: "DG heat disinfect temperature gradient out of range.", + 102: "Call service to schedule a repair.", 103: "Call service to schedule a repair.", 104: "Call service to schedule a repair.", 105: "Call service to schedule a repair.", @@ -128,7 +424,7 @@ 110: "Call service to schedule a repair.", 111: "Call service to schedule a repair.", 112: "Call service to schedule a repair.", - 113: "HD blood leak zero command fault.", + 113: "Call service to schedule a repair.", 114: "Call service to schedule a repair.", 115: "Call service to schedule a repair.", 116: "Call service to schedule a repair.", @@ -161,22 +457,22 @@ 143: "Call service to schedule a repair.", 144: "DG RO flow sensor invalid calibration record.", 145: "Dialysate conductivity is out of range. Check the acid dialysate concentrates and make sure the correct concentrate is connected.", - 146: "DG RTC or timer accuracy failure.", + 146: "Call service to schedule a repair.", 147: "Call service to schedule a repair.", 148: "Inlet water temperature is high. Check the incoming water for issues with cold water supply.", 149: "Inlet water temperature is low. Check the incoming water for issues with hot water supply.", 150: "Inlet water conductivity is high. Check the incoming water for issues.", 151: "Inlet water conductivity is low. Check the incoming water for issues.", 152: "Inlet water pressure is low. Check the incoming water supply.", - 153: "HD prime completed high priority alarm.", + 153: "Prime of the bloodlines is complete.", 154: "Communication has been lost. Ensure all cords are securely connected.", - 155: "Alarm ID available for use.", - 156: "Alarm ID available for use.", + 155: "Not used.", + 156: "Not used.", 157: "DG chemical disinfect prime acid line timeout.", 158: "Inlet water temperature is in the low range.", 159: "Dialysate pump failure. Check there are no kinks in the dialysate tubing.", 160: "Blood pump failure. Check the pump rotor for secure connection.", - 161: "DG comm too many bad CRCs.", + 161: "Call service to schedule a repair.", 162: "DG FPGA clock speed check failure.", 163: "Ultrafiltration error.", 164: "Ultrafiltration error.", @@ -188,10 +484,10 @@ 170: "Heparin syringe empty. Option to resume treatment without heparin.", 171: "Heparin pump occlusion detected. Check heparin line is unclamped and there are no kinks in the heparin line.", 172: "Not enough heparin is available for treatment. Check if syringe pump is touching syringe plunger. If syringe pump is touching syringe plunger, end treatment. If syringe pump is not touching syringe plunger, reload syringe with enough heparin.", - 173: "HD RTC configuration error.", - 174: "HD RTC or timer accuracy failure.", + 173: "Call service to schedule a repair.", + 174: "Call service to schedule a repair.", 175: "Blood pump eailure. Check the pump rotor for secure connection.", - 176: "HD active reservoir is full during treatment and DG not ready to switch reservoirs.", + 176: "HD dialysate temperature out of high safety range.", 177: "Call service to schedule a repair.", 178: "HD communication timeout.", 179: "Call service to schedule a repair.", @@ -208,7 +504,7 @@ 190: "Call service to schedule a repair.", 191: "Call service to schedule a repair.", 192: "Call service to schedule a repair.", - 193: "Alarm available for use.", + 193: "HD dialysate temperature out of low safety range.", 194: "Call service to schedule a repair.", 195: "Call service to schedule a repair.", 196: "Call service to schedule a repair.", @@ -228,7 +524,7 @@ 210: "Battery pack error.", 211: "Maximum time for blood stoppage has been exceeded.", 212: "Maximum time for blood stoppage has been exceeded.", - 213: "HD prime completed medium priority alarm.", + 213: "Prime of the bloodlines is complete.", 214: "Inability to deliver saline bolus. Check for kinks or clamped lines in the saline line.", 215: "Unable to complete Rinseback. Check for kinks or clamped blood lines.", 216: "Treatment has ended", @@ -248,7 +544,7 @@ 230: "Priming failure. Check blood and dialysate lines for clamps and kinks.", 231: "Self Test Failure. Please ensure the disposable cartridge is completely installed and the handle moved to the down position.", 232: "Self Test Failure. Please ensure the disposable cartridge is completely installed and the handle moved to the down position. Check for closed clamps or kinks in the tubing.", - 233: "Battery pack error.", + 233: "DG barometric sensor coefficients bad CRC.", 234: "Communication failure. Ensure all cords are securely connected.", 235: "Rinseback has been completed.", 236: "New cartridge needs to be installed.", @@ -271,20 +567,20 @@ 253: "Call service to schedule a repair.", 254: "Call service to schedule a repair.", 255: "Call service to schedule a repair.", - 256: "HD and DG software builds are not compatible.", + 256: "Call service to schedule a repair.", 257: "Call service to schedule a repair.", 258: "HD FPGA power out timeout.", 259: "Call service to schedule a repair.", - 260: "UI POST Application Integrity (Sha256Sum) failure.", - 261: "UI POST CANBus failure.", - 262: "UI POST Display failure.", - 263: "UI POST Touch failure.", - 264: "UI POST SD-Card failure.", - 265: "UI POST RTC failure.", - 266: "UI POST WiFi failure.", - 267: "UI POST Bluetooth failure.", - 268: "UI POST Ethernet failure.", - 269: "UI POST Sound failure.", + 260: "Call service to schedule a repair.", + 261: "Call service to schedule a repair.", + 262: "Call service to schedule a repair.", + 263: "Call service to schedule a repair.", + 264: "Power cycle the system.\nCall service to schedule a repair if problem persist.", + 265: "Call service to schedule a repair.", + 266: "Call service to schedule a repair.", + 267: "Call service to schedule a repair.", + 268: "Call service to schedule a repair.", + 269: "Call service to schedule a repair.", 270: "Call service to schedule a repair.", 271: "Call service to schedule a repair.", 272: "Fan failure. Check that the fans inlets are not blocked or obstructed.", @@ -299,7 +595,7 @@ 281: "Acid concentrate low. Replace acid concentrate bottle.", 282: "Bicarbonate concentrate low. Replace bicarbonate concentrate bottle.", 283: "Call service to schedule a repair.", - 284: "DG load cells primary/back up drift out of range.", + 284: "Call service to schedule a repair.", 285: "Dialysate recirculation error.", 286: "Rinseback complete.", 287: "Call service to schedule a repair.", Index: tst_ui_alarms_dialog/test.py =================================================================== diff -u -rabbb06cfcc9001b2e1ceb0a9c964e0c219754d69 -reb47b728e03c07a2ecb47a858983bfbbc9ad657e --- tst_ui_alarms_dialog/test.py (.../test.py) (revision abbb06cfcc9001b2e1ceb0a9c964e0c219754d69) +++ tst_ui_alarms_dialog/test.py (.../test.py) (revision eb47b728e03c07a2ecb47a858983bfbbc9ad657e) @@ -288,6 +288,7 @@ minimize() test.compare(str(waitForObjectExists(names.o_alarm_bar_text ).text), config.UNDEFINED_ALARM_ID_MSG.format(alarm_id), "verified alarm message for exceeded alarm id's") else: + test.log(str(alarm_id)) test.compare(str(waitForObjectExists(names.o_alarm_text_description).text), config.ALARM_ID_AND_ALARM_MESSAGES[alarm_id], "Alarm message is verified from alarm dialog box") minimize() test.compare(str(waitForObjectExists(names.o_alarm_bar_text ).text), config.ALARM_ID_AND_ALARM_MESSAGES[alarm_id], "Alarm message is verified from alarm bar") Index: tst_ui_alarms_list/test.py =================================================================== diff -u -r642015a2dd0cf927bf5868ac2d16be8bb8dd997a -reb47b728e03c07a2ecb47a858983bfbbc9ad657e --- tst_ui_alarms_list/test.py (.../test.py) (revision 642015a2dd0cf927bf5868ac2d16be8bb8dd997a) +++ tst_ui_alarms_list/test.py (.../test.py) (revision eb47b728e03c07a2ecb47a858983bfbbc9ad657e) @@ -73,7 +73,7 @@ alarm_id_list = [] id_count = 0 while id_count < 10: - id = randint(1, config.NUM_OF_MSG_ID) + id = randint(1, config.NUM_OF_ALARM_ID+1) if id in alarm_id_list: pass else: