Index: Alarms/Alarms.conf =================================================================== diff -u -r0b7f812ec4f375dc260836133d786386a866d4cc -r0567f0d0212467a2b1060f85dfcdea3fe88b323d --- Alarms/Alarms.conf (.../Alarms.conf) (revision 0b7f812ec4f375dc260836133d786386a866d4cc) +++ Alarms/Alarms.conf (.../Alarms.conf) (revision 0567f0d0212467a2b1060f85dfcdea3fe88b323d) @@ -518,7 +518,7 @@ [97] Title = Conductivity Out of Range ListTitle = Dial. Gen: Dialysate Cond. -Message = Treatment is currently paused.\n- Confirm that acid and bicarbonate concentrates\nare securely connected.\n- If empty, replace. \n- Treatment will need to be resumed when conductivity\nis within target range. +Message = Treatment is currently paused.\n- Confirm that acid and bicarbonate concentrates are securely\nconnected.\n- If bubbles are observed in either of the concentrate lines\nreplace it with a new concentrate container.\n- Treatment will need to be resumed when conductivity\nis within target range. SRSDG 397 = [98] @@ -1170,14 +1170,14 @@ Message = The priming process completed 90 minutes ago. \n- Treatment must begin within 30 minutes or the\npre- treatment process will be terminated.\n- Press Resume/OK to continue. [214] -Title = -ListTitle = -Message = +Title = Service Required: Dialysate Device +ListTitle = DG POST: Conc Pump Cal +Message = A problem was detected with the dialysate device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. [215] -Title = -ListTitle = -Message = +Title = Air Trap Overfill +ListTitle = Air Trap: Air Trap Overfill +Message = Air trap level high for too long. \n- Assess venous access and resolve access issues, if applicable.\n- Ensure venous chamber line is securely clamped.\n- Check air trap for foam and that transducers are secured.\n- Inspect transducer for moisture and change, if applicable.\n- Inspect blood lines for clots, address as clinically indicated\n per facility policy. \n- Press Resume/OK to continue treatment. [216] Title = Treatment Complete @@ -1577,15 +1577,15 @@ SRSDG 888 = [281] -Title = Acid Concentrate Low -ListTitle = Dial. Gen: Acid Conc. Low -Message = The acid concentrate is low.\n- Replace acid concentrate container. +Title = +ListTitle = +Message = SRSDG 836 = [282] -Title = Bicarb Concentrate Low -ListTitle = Dial. Gen: Bicarb Conc. Low -Message = Bicarbonate concentrate is low.\n- Replace the bicarbonate concentrate container. +Title = +ListTitle = +Message = SRSDG 837 = [283]