Index: Alarms/Alarms.conf =================================================================== diff -u -r0b7f812ec4f375dc260836133d786386a866d4cc -r223ddd5b4dc234e30c7c91194eb6b281535a3a92 --- Alarms/Alarms.conf (.../Alarms.conf) (revision 0b7f812ec4f375dc260836133d786386a866d4cc) +++ Alarms/Alarms.conf (.../Alarms.conf) (revision 223ddd5b4dc234e30c7c91194eb6b281535a3a92) @@ -518,7 +518,7 @@ [97] Title = Conductivity Out of Range ListTitle = Dial. Gen: Dialysate Cond. -Message = Treatment is currently paused.\n- Confirm that acid and bicarbonate concentrates\nare securely connected.\n- If empty, replace. \n- Treatment will need to be resumed when conductivity\nis within target range. +Message = Treatment is currently paused.\n- Confirm that acid and bicarbonate concentrates are securely\nconnected.\n- If bubbles are observed in either of the concentrate lines\nreplace it with a new concentrate container.\n- Treatment will need to be resumed when conductivity\nis within target range. SRSDG 397 = [98] @@ -684,7 +684,7 @@ [127] Title = Low Venous Pressure ListTitle = Blood Stop: Venous Pres. Low -Message = Venous pressure is low.\n- Ensure venous access connections are properly secured.\n- Check needle placement and resolve access issues, \nif applicable.\n- Check air trap for foam and that transducers are secured.\n- Inspect transducer for moisture and change, if applicable.\n- Inspect dialyzer for clots. If clots are present, follow\n facility policy to end treatment.\n- Press Resume/OK to continue treatment. +Message = Venous pressure is low.\n- Assess venous access and blood lines, correct issues if needed.\n- Check air trap and venous pressure lines for foam and that\ntransducers are secured.\n- Inspect venous transducer for moisture; change if needed.\n- Inspect dialyzer for clots. If clots are present, follow facility\npolicy to end treatment.\n- Press Resume/OK to continue treatment. [128] Title = Venous Air Detected @@ -699,7 +699,7 @@ [130] Title = High Venous Pressure ListTitle = Blood Stop: Venous Pres. High -Message = Venous pressure is high. \n- Check venous bloodlines for kinks or clamps.\n- Check needle placement and/or access position.\n- Resolve access issues, if applicable.\n- Check air trap for foam and that transducers are secured.\n- Inspect transducer for moisture and change, if applicable.\n- If clots are present, end treatment without rinseback.\n- Press Resume/OK to continue treatment. +Message = Venous pressure is high. \n- Check venous bloodlines for kinks or clamps.\n- Check needle placement and/or access position.\n- Resolve access issues, if applicable.\n- Check air trap and venous pressure line for foam and that\ntransducers are secured.\n- Inspect venous transducer for moisture; change if applicable.\n- If clots are present, end treatment without rinseback.\n- Press Resume/OK to continue treatment. [131] Title = Low Arterial Pressure @@ -1140,8 +1140,8 @@ [208] Title = High Venous Pressure -ListTitle = Blood Stop: Venous Pres. High -Message = Venous pressure is high. \n- Check venous bloodlines for kinks or clamps.\n- Check needle placement and/or access position.\n- Resolve access issues, if applicable.\n- If clots are present, end treatment without rinseback. +ListTitle = HD venous line occlusion fault +Message = Venous pressure is high. \n- Check venous bloodlines for kinks or clamps.\n- Check needle placement and/or access position.\n- Resolve access issues, if applicable.\n- Check air trap and venous pressure line for foam and that\ntransducers are secured.\n- Inspect venous transducer for moisture; change if applicable.\n- If clots are present, end treatment without rinseback.\n- Press Resume/OK to continue treatment. [209] Title = Disinfection Interrupted @@ -1170,24 +1170,24 @@ Message = The priming process completed 90 minutes ago. \n- Treatment must begin within 30 minutes or the\npre- treatment process will be terminated.\n- Press Resume/OK to continue. [214] -Title = -ListTitle = -Message = +Title = Service Required: Dialysate Device +ListTitle = DG POST: Conc Pump Cal +Message = A problem was detected with the dialysate device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. [215] -Title = -ListTitle = -Message = +Title = Air Trap Overfill +ListTitle = Air Trap: Air Trap Overfill +Message = Air trap level high for too long. \n- Assess venous access and resolve access issues, if applicable.\n- Ensure venous chamber line is securely clamped.\n- Check air trap and venous pressure line for foam and that\ntransducers are secured.\n- Inspect venous transducer for moisture; change if applicable.\n- Inspect blood lines for clots, address as clinically indicated\n per facility policy. \n- Press Resume/OK to continue treatment. [216] Title = Treatment Complete ListTitle = Process: End of Dialysis Tx Message = Dialysis treatment is complete.\n- Press RINSEBACK to end treatment and rinseback. [217] -Title = -ListTitle = -Message = +Title = Multiple Air Trap Events +ListTitle = Air Trap: Multiple Air Trap Events +Message = Multiple air trap events have been detected. \n- Assess venous access and resolve access issues, if applicable.\n- Ensure venous chamber line is securely clamped.\n- Check air trap and venous pressure line for foam and that\ntransducers are secured.\n- Inspect venous transducer for moisture; change if applicable.\n- Inspect blood lines for clots, address as clinically indicated\n per facility policy. \n- Press Resume/OK to continue treatment. [218] Title = Syringe Detected @@ -1577,15 +1577,15 @@ SRSDG 888 = [281] -Title = Acid Concentrate Low -ListTitle = Dial. Gen: Acid Conc. Low -Message = The acid concentrate is low.\n- Replace acid concentrate container. +Title = +ListTitle = +Message = SRSDG 836 = [282] -Title = Bicarb Concentrate Low -ListTitle = Dial. Gen: Bicarb Conc. Low -Message = Bicarbonate concentrate is low.\n- Replace the bicarbonate concentrate container. +Title = +ListTitle = +Message = SRSDG 837 = [283]