Index: Instructions/Instructions.conf =================================================================== diff -u -rdb84bcccb056d9f1c922a9c8e03cc352fa3ad811 -r2d98cfee7be7197041e0e33b006e3ff6258dffe2 --- Instructions/Instructions.conf (.../Instructions.conf) (revision db84bcccb056d9f1c922a9c8e03cc352fa3ad811) +++ Instructions/Instructions.conf (.../Instructions.conf) (revision 2d98cfee7be7197041e0e33b006e3ff6258dffe2) @@ -1,66 +1,73 @@ [Sample^Water Sample] -Place cup in the water sampling pocket. Press and hold the "Water Sample" button. = 07 water_sampling_v2.png +Place cup in the water sampling pocket. Press and hold the "Water Sample" button. = 8_water sampling_v4.png [Sample^Water Sample Result] -Test the water sample per your clinic's instructions and enter the result. = 29 water test_v2.png +Test the water sample per your clinic's instructions and enter the result. = 44_water test pass fail-01.png [Sample^Water Sample Result Failed] -Water sample result failed. = 30 water test failed_v2.png +Water sample result failed. = 44_water test fail B-01.png [Consumables^Consumables Installation] -Remove the concentrate and dialysate caps. = 09 remove right cap_v2.png -Connect the acid concentrate to the acid port. = 12 install acid line_v2.png -Connect the bicarbonate concentrate to the bicarbonate port. = 14 install bicarb line_v2.png +Remove the concentrate and dialysate caps. = 48_remove caps alternative-01.png +Connect the acid concentrate to the acid port. = 13_install acid line_v4.png +Connect the bicarbonate concentrate to the bicarbonate port. = 14_install bicarb line_v4.png [Disposables^Cartridge Installation] -Open the front panel door. = 01 door open_v2.png -Unlock the pump track by moving the lever to its upward position. = 06 pump track open_v2.png -Install the cartridge using the alignment pins.\nInsert tubing into blood and dialsyate pumps = 03 insert cassette_v2.png -Lock the pump track by moving the lever to its downward position. = 05 pump track lock_v2.png +Open the front panel door. = 1_HD door open-01.png +Unlock the pump track by moving the lever to its upward position. = 7_pump track open-01.png +Install the cartridge using the alignment pins. = 3_insert casette-01.png +Insert tubing into blood and dialsyate pumps. = 4_loop casette tubes-01.png +Lock the pump track by moving the lever to its downward position. = 6_Pump track lock-01.png [Disposables^Cartridge Connection] -Connect the cartridge blood lines to the dialyzer. = 18 filter connections_v2.png -Connect the cartridge dialysis fluid lines to the dialyzer. = 18 filter connections_v2.png -Insert dialyzer into the clamps. = 17 load filter unit_v2.png -Connect the cartridge tubing line to the air vent port. = 19 PBo connection_v2.png -Connect the cartridge dialysis fluid lines to the DG fluid ports. = 15 install dialysate to DG_v2.png +Connect the cartridge blood lines to the dialyzer. = 25_filter connection 1A+1B-01.png +Connect the cartridge dialysis fluid lines to the dialyzer. = 26_fiilter connection 2A + 2B-01.png +Insert dialyzer into the clamps. = 24_load filter-01.png +Connect the arterial pressure line to the arterial pressure transducer port. = 27_PBo connection Arterial-01.png +Connect the venous pressure line to the venous pressure transducer port. = 28_PBo connection venous-01.png +Connect the cartridge dialysis fluid lines to the DG fluid ports. = 20_dialysate lines to DG_v4.png [Disposables^Heparin Syringe] -Fill a syringe with heparin and connect the cartridge heparin tubing line. \nInsert syringe into infusion pump housing. = 21 load syringe_v2.png +Fill a syringe with heparin and connect the cartridge heparin tubing line. = 30_fill syringe with heparin_v4.png +Insert heparin filled syringe into the infusion pump housing. = 31_load syringe-01.png [Disposables^Saline Bag] -Hang the saline bag on the left side hook. Spike a saline bag and connect it to the cartridge saline line. = 23 saline connect_v2.png -Close the front panel door. = 02 door closed_v2.png +Hang the saline bag on the left side hook. Spike a saline bag and connect it to the cartridge saline line. = 34_saline connect-01.png +Pinch saline y-connector to the closed position. = 35_clamping Y connecter-01.png +Close the front panel door. = 2_HD door closed-01.png [Connection^Patient Connection] -Wash your hands and establish vascular access per your clinic's instructions. = 31 wash hand_v2.png -Pinch arterial clamp and venous clamp on located on the cartridge patient lines. = 16 pinch tubing_v2.png -Remove arterial and venous line connector. = 25 remove stunt_v2.png -Connect arterial and venous cartridge lines to your patient access lines. = 24 connect fistula_v2.png +Draw a dialysate sample from the needless valve port. = 21_take sample with syringe_v4.png +Wash your hands and establish vascular access per your clinic's instructions. = 45_wash hands-01.png +Pinch arterial clamp and venous clamp on located on the cartridge patient lines. = 23_pinch Arteriaal and Venous tubes-01.png +Remove arterial and venous line connector. = 39_remove shunt_v4.png +Connect arterial and venous cartridge lines to your patient access lines. = 36_connect Arterial Venous to cartridge-01.png [Connection^Start Treatment] -Unpinch arterial clamp and venous clamp located on the cartridge patient lines. = 16 pinch tubing_v2.png +Unpinch arterial clamp and venous clamp located on the cartridge patient lines. = 37_unpinch Arterial Venous to patient-01.png [^Rinseback Setup] -Pinch arterial line and saline bag line. = 27 clamp arterial and saline_v2.png -Connect arterial line to the saline bag. = 26 connect arterial line_v2.png -Unpinch clamps at the arterial line, saline bag line, and Y-connector. = 28 unclamp arterial and saline_v2.png +Pinch arterial line and disconnect patient access line. = 38_disconnect Arterial patient access-01.png +Connect arterial line to the saline Y-connector and unpinch clamp. = 40_connect Arterial line-01.png +Unpinch clamps at the arterial line and saline bag line. = 42_unclamp Arterial saline Line-01.png [^Rinseback Complete] -Pinch arterial and venous line after rinseback is complete. = 27 clamp arterial and saline_v2.png +Pinch arterial and venous line after rinseback is complete. = 41_clamp Arterial saline Line-01.png [Disconnection^Patient Disconnection] -Pinch arterial clamp and venous clamp on located on the cartridge patient lines and access lines. = 16 pinch tubing_v2.png -Disconnect arterial and venous cartridge lines from your patient access lines. = 24 connect fistula_v2.png +Pinch arterial clamp and venous clamp on located on the cartridge patient lines and access lines. = 37_unpinch Arterial Venous to patient-01.png +Disconnect arterial and venous cartridge lines from your patient access lines. = 38_disconnect Arterial patient access-01.png [Disposables^Disposables Removal] -Disconnect the cartridge tubing line connected to the air vent port. = 20 PBo connection remove_v2.png -Remove heparin syringe from the infusion pump housing. = 22 remove syringe_v2.png -Disconnect acid and bicarbonate concentrates. Install concentrate fluid cap. = 11 install right cap_v2.png -Disconnect cartridge dialysate lines and connect ends together.\nInstall top dialysis fluid cap. = 10 install left cap_v2.png -Unlock the pump track by moving the lever to its upward position. = 06 pump track open_v2.png +Disconnect the arterial and venous pressure lines. = 29_PBo connection remove-01.png +Remove heparin syringe from the infusion pump housing. = 33_remove syringe-01.png +Pinch dialysate lines and disconnect tubing lines from the system. = 22_disconnect dialysate from cassette_v4.png +Install dialysis dialysis fluid cap. = 15_replace dialysate line cap_v4.png +Disconnect acid and bicarbonate concentrates tubing lines from the system. 16_remove acid and bicarb connect_v4.png +Install concentrate fluid cap. = 19_replace concentrate cap-01.png +Unlock the pump track by moving the lever to its upward position. = 7_pump track open-01.png Remove cartridge and dialyzer from the HD device. = 04 remove cassette_v2.png @@ -75,4 +82,6 @@ Disinfection3=logo.png [Chemical Disinfect^Chemical Disinfect] -Disinfection1=logo.png +Remove the concentrate fluid cap and connect the chemical disinfectant = 17_connect PAA_v4.png +Disconnect the chemical disinfecatn and replace concentrate cap. = 19_replace concentrate cap-01.png +Test the system for residual chemicals using a test strip. = 43_test residual sample-01.png \ No newline at end of file