Index: Instructions/01 door open_v2.png =================================================================== diff -u Binary files differ Index: Instructions/02 door closed_v2.png =================================================================== diff -u Binary files differ Index: Instructions/03 insert cassette_v2.png =================================================================== diff -u Binary files differ Index: Instructions/04 remove cassette_v2.png =================================================================== diff -u Binary files differ Index: Instructions/05 pump track lock_v2.png =================================================================== diff -u Binary files differ Index: Instructions/06 pump track open_v2.png =================================================================== diff -u Binary files differ Index: Instructions/07 water_sampling_v2.png =================================================================== diff -u Binary files differ Index: Instructions/08 remove left cap_v2.png =================================================================== diff -u Binary files differ Index: Instructions/09 remove right cap_v2.png =================================================================== diff -u Binary files differ Index: Instructions/10 install left cap_v2.png =================================================================== diff -u Binary files differ Index: Instructions/11 install right cap_v2.png =================================================================== diff -u Binary files differ Index: Instructions/12 install acid line_v2.png =================================================================== diff -u Binary files differ Index: Instructions/14 install bicarb line_v2.png =================================================================== diff -u Binary files differ Index: Instructions/15 install dialysate to DG_v2.png =================================================================== diff -u Binary files differ Index: Instructions/16 pinch tubing_v2.png =================================================================== diff -u Binary files differ Index: Instructions/17 load filter unit_v2.png =================================================================== diff -u Binary files differ Index: Instructions/18 filter connections_v2.png =================================================================== diff -u Binary files differ Index: Instructions/19 PBo connection_v2.png =================================================================== diff -u Binary files differ Index: Instructions/20 PBo connection remove_v2.png =================================================================== diff -u Binary files differ Index: Instructions/21 load syringe_v2.png =================================================================== diff -u Binary files differ Index: Instructions/22 remove syringe_v2.png =================================================================== diff -u Binary files differ Index: Instructions/23 saline connect_v2.png =================================================================== diff -u Binary files differ Index: Instructions/24 connect fistula_v2.png =================================================================== diff -u Binary files differ Index: Instructions/25 remove stunt_v2.png =================================================================== diff -u Binary files differ Index: Instructions/26 connect arterial line_v2.png =================================================================== diff -u Binary files differ Index: Instructions/27 clamp arterial and saline_v2.png =================================================================== diff -u Binary files differ Index: Instructions/28 unclamp arterial and saline_v2.png =================================================================== diff -u Binary files differ Index: Instructions/29 water test_v2.png =================================================================== diff -u Binary files differ Index: Instructions/30 water test failed_v2.png =================================================================== diff -u Binary files differ Index: Instructions/31 wash hand_v2.png =================================================================== diff -u Binary files differ Index: Instructions/32 treatment to web portal_v2.png =================================================================== diff -u Binary files differ Index: Instructions/Dialysate lines to DG Y v4-01.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/HD door open_v1.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/Instructions.conf =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a --- Instructions/Instructions.conf (.../Instructions.conf) (revision 4a647f3849cb1f8c4877cc194f21f143f529b0c6) +++ Instructions/Instructions.conf (.../Instructions.conf) (revision 4121334904b09960dd7edb4a7c6658be95a4dc5a) @@ -1,69 +1,67 @@ [Sample^Water Sample] -Place cup in the water sampling pocket. Press and hold the "Water Sample" button. = water sampling_v2.png +Place cup in the water sampling pocket. Press and hold the "Water Sample" button. = 07 water_sampling_v2.png [Sample^Water Sample Result] -Test the water sample per your clinic's instructions and enter the result. = temp_water_test.png +Test the water sample per your clinic's instructions and enter the result. = 29 water test_v2.png [Sample^Water Sample Result Failed] -Water sample result failed. = logo.png +Water sample result failed. = 30 water test failed_v2.png [Consumables^Consumables Installation] -Open the DG concentrate door. = concentrate door open-v1.png -Remove the bottom acid/bicarbonate cap. = remove Acid_Bicab cap-v2.png -Connect the acid concentrate to the acid port. = connect acid line v2-01.png -Connect the bicarbonate concentrate to the bicarbonate port. = connect bicarb ine-v2-01 +Remove the concentrate and dialysate caps. = 09 remove right cap_v2.png +Connect the acid concentrate to the acid port. = 12 install acid line_v2.png +Connect the bicarbonate concentrate to the bicarbonate port. = 14 install bicarb line_v2.png [Disposables^Cartridge Installation] -Open the front panel door.\nAnd check the cartridge. = door up v2.png -Unlock the pump track by moving the lever to its upward position. = cassette clamp release v1.png -Install the cartridge using the alignment pins. = insert cassette v2-01-01.png -Lock the pump track by moving the lever to its downward position. = cassette clamp lock v2-01.png +Open the front panel door. = 01 door open_v2.png +Unlock the pump track by moving the lever to its upward position. = 06 pump track open_v2.png +Install the cartridge using the alignment pins.\nInsert tubing into blood and dialsyate pumps = insert cassette v2-01-01.png +Lock the pump track by moving the lever to its downward position. = 05 pump track lock_v2.png [Disposables^Cartridge Connection] -Connect the cartridge blood and dialysis fluid lines to the dialyzer. = filter connect_72.png -Insert dialyzer into the clamps. = filter load_72.png -Connect the cartridge tubing line to the air vent port. = PBo connect_72.png -Remove the top dialysis fluid cap DG system. = remove top cap v2-01.png -Connect the cartridge dialysis fluid lines to the DG fluid ports. = Dialysate lines to DG Y v4-01.png +Connect the cartridge blood lines to the dialyzer. = 18 filter connections_v2.png +Connect the cartridge dialysis fluid lines to the dialyzer. = 18 filter connections_v2.png +Insert dialyzer into the clamps. = 17 load filter unit_v2.png +Connect the cartridge tubing line to the air vent port. = 19 PBo connection_v2.png +Connect the cartridge dialysis fluid lines to the DG fluid ports. = 15 install dialysate to DG_v2.png [Disposables^Heparin Syringe] -Fill a syringe with heparin and connect the cartridge heparin tubing line. = syringe connect_72.png -Insert syringe into infusion pump housing. = syringe connected insert v2.png +Fill a syringe with heparin and connect the cartridge heparin tubing line. \nInsert syringe into infusion pump housing. = 21 load syringe_v2.png [Disposables^Saline Bag] -Hang the saline bag on the left side hook. Spike a saline bag and connect it to the cartridge saline line. = saline connect_72.png +Hang the saline bag on the left side hook. Spike a saline bag and connect it to the cartridge saline line. = 23 saline connect_v2.png +Close the front panel door. = 02 door closed_v2.png [Connection^Patient Connection] -Wash your hands and establish vascular access per your clinic's instructions. = logo.png -Pinch arterial clamp and venous clamp on located on the cartridge patient lines. = pinch paient lines v2.png -Remove arterial and venous shunt. = untwist stunt_72.png -Connect arterial and venous cartridge lines to your patient access lines. = alt connect fistula_72.png +Wash your hands and establish vascular access per your clinic's instructions. = 31 wash hand_v2.png +Pinch arterial clamp and venous clamp on located on the cartridge patient lines. = 16 pinch tubing_v2.png +Remove arterial and venous line connector. = 25 remove stunt_v2.png +Connect arterial and venous cartridge lines to your patient access lines. = 24 connect fistula_v2.png [Connection^Start Treatment] -Unpinch arterial clamp and venous clamp located on the cartridge patient lines. = unclamp_patient_lines_temp +Unpinch arterial clamp and venous clamp located on the cartridge patient lines. = 16 pinch tubing_v2.png [^Rinseback Setup] -Pinch arterial line and saline bag line. = logo.png -Connect arterial line to the saline bag. = arterial to saline_v1.png -Unpinch arterial line and saline back line. = logo.png +Pinch arterial line and saline bag line. = 27 clamp arterial and saline_v2.png +Connect arterial line to the saline bag. = 26 connect arterial line_v2.png +Unpinch clamps at the arterial line, saline bag line, and Y-connector. = 28 unclamp arterial and saline_v2.png [^Rinseback Complete] -Pinch arterial and venous line after rinseback is complete. = pinch paient lines v2.png +Pinch arterial and venous line after rinseback is complete. = 27 clamp arterial and saline_v2.png [Disconnection^Patient Disconnection] Pinch arterial clamp and venous clamp on located on the cartridge patient lines and access lines. = pinch paient lines v2.png -Disconnect arterial and venous cartridge lines from your patient access lines. = Remove_patient connection temp.png +Disconnect arterial and venous cartridge lines from your patient access lines. = 24 connect fistula_v2.png [Disposables^Disposables Removal] -Shunt the arterial and venous lines on the cartridge. = Twist shunt_temp.png -Disconnect the cartridge tubing line connected to the air vent port. = pbo release v1.png -Remove heparin syringe from the infusion pump housing. = syringe removal v1.png -Disconnect cartridge dialysate lines and connect ends together.\nInstall top dialysis fluid cap. = install top cap v1-01.png -Disconnect acid and bicarbonate concentrates. Install bottom concentrate fluid cap. = install lower cap v1-01.png -Unlock the pump track by moving the lever to its upward position. = cassette clamp release v1.png -Remove cartridge and dialyzer from the HD device. = logo.png +Disconnect the cartridge tubing line connected to the air vent port. = 20 PBo connection remove_v2.png +Remove heparin syringe from the infusion pump housing. = 22 remove syringe_v2.png +Disconnect acid and bicarbonate concentrates. Install concentrate fluid cap. = 11 install right cap_v2.png +Disconnect cartridge dialysate lines and connect ends together.\nInstall top dialysis fluid cap. = 10 install left cap_v2.png +Unlock the pump track by moving the lever to its upward position. = 06 pump track open_v2.png +Remove cartridge and dialyzer from the HD device. = 04 remove cassette_v2.png [^Recirculate] Index: Instructions/PBo connect_72.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/Remove_patient connection temp.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/Twist shunt_temp.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/alt connect fistula_72.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/arterial to saline_v1.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/cassette clamp lock v2-01.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/cassette clamp release v1.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/concentrate door open-v1.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/connect acid line v2-01.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/connect bicarb ine-v2-01.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/door down v2.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/door up v2.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/filter connect_72.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/filter load_72.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/insert cassette v2-01-01.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/install lower cap v1-01.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/install top cap v1-01.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/pbo release v1.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/pinch paient lines v2.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/remove Acid_Bicab cap-v2.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/remove top cap v2-01.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/saline connect_72.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/syringe connect_72.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/syringe connected insert v2.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/syringe removal v1.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/temp_water_test.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/unclamp_patient_lines_temp.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/untwist stunt_72.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ Index: Instructions/water sampling_v2.png =================================================================== diff -u -r4a647f3849cb1f8c4877cc194f21f143f529b0c6 -r4121334904b09960dd7edb4a7c6658be95a4dc5a Binary files differ